Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pool Fire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Development of a MELCOR Sodium Chemistry (NAC) Package - FY17 Progress.

This report describes the status of the development of MELCOR Sodium Chemistry (NAC) package. This development is based on the CONTAIN-LMR sodium physics and chemistry models to be implemented in MELCOR. In the past three years, the sodium equation of state as a working fluid from the nuclear fusion safety research and from the SIMMER code has been implemented into MELCOR. The chemistry models from the CONTAIN-LMR code, such as the spray and pool fire mode ls, have also been implemented into MELCOR. This report describes the implemented models and the issues encountered. Model descriptions and input descriptions are provided. Development testing of the spray and pool fire models is described, including the code-to-code comparison with CONTAIN-LMR. The report ends with an expected timeline for the remaining models to be implemented, such as the atmosphere chemistry, sodium-concrete interactions, and experimental validation tests .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Carbon fiber plume sampling for large scale fire tests at Dugway Proving Ground

Carbon fiber sampling instruments were developed: passive collectors made of sticky bridal veil mesh, and active instruments using a light emitting diode (LED) source. These instruments measured the number or number rate of carbon fibers released from carbon/graphite composite material when the material was burned in a 10.7 m (35 ft) dia JP-4 pool fire for approximately 20 minutes. The instruments were placed in an array suspended from a 305 m by 305 m (1000 ft by 1000 ft) Jacob's Ladder net held vertically aloft by balloons and oriented crosswind approximately 140 meters downwind of the pool fire. Three tests were conducted during which released carbon fiber data were acquired. These data were reduced and analyzed to obtain the characteristics of the released fibers including their spatial and size distributions and estimates of the number and total mass of fibers released. The results of the data analyses showed that 2.5 to 3.5 x 10 to the 8th power single carbon fibers were released during the 20 minute burn of 30 to 50 kg mass of initial, unburned carbon fiber material. The mass released as single carbon fibers was estimated to be between 0.1 and 0.2% of the initial, unburned fiber mass.

Chovit, A. R.↗

Regulatory fire test requirements for plutonium air transport packages : JP-4 or JP-5 vs. JP-8 aviation fuel.

For certification, packages used for the transportation of plutonium by air must survive the hypothetical thermal environment specified in 10CFR71.74(a)(5). This regulation specifies that 'the package must be exposed to luminous flames from a pool fire of JP-4 or JP-5 aviation fuel for a period of at least 60 minutes.' This regulation was developed when jet propellant (JP) 4 and 5 were the standard jet fuels. However, JP-4 and JP-5 currently are of limited availability in the United States of America. JP-4 is very hard to obtain as it is not used much anymore. JP-5 may be easier to get than JP-4, but only through a military supplier. The purpose of this paper is to illustrate that readily-available JP-8 fuel is a possible substitute for the aforementioned certification test. Comparisons between the properties of the three fuels are given. Results from computer simulations that compared large JP-4 to JP-8 pool fires using Sandia's VULCAN fire model are shown and discussed. Additionally, the Container Analysis Fire (CAFE) code was used to compare the thermal response of a large calorimeter exposed to engulfing fires fueled by these three jet propellants. The paper then recommends JP-8 as an alternate fuel that complies with the thermal environment implied in 10CFR71.74.

33 ADVANCED PROPULSION SYSTEMS↗

Comparison of the safety-related physical and combustion properties of liquid hydrogen and liquid natural gas in the context of the SF-BREEZE high-speed fuel-cell ferry

Here, we review liquid hydrogen (LH 2 ) as a maritime vessel fuel, from descriptions of its fundamental properties to its practical application and safety aspects, in the context of the San Francisco Bay Renewable Energy Electric Vessel with Zero Emissions (SF-BREEZE) high-speed fuel-cell ferry. Since marine regulations have been formulated to cover liquid natural gas (LNG) as a primary propulsion fuel, we frame our examination of LH 2 as a comparison to LNG, for both maritime use in general, and the SF-BREEZE in particular. Due to weaker attractions between molecules, LH 2 is colder than LNG, and evaporates more easily. We describe the consequences of these physical differences for the size and duration of spills of the two cryogenic fuels. The classical flammability ranges are reviewed, with a focus on how fuel buoyancy modifies these combustion limits. We examine the conditions for direct fuel explosion (detonation) and contrast them with initiation of normal (laminar) combustion. Direct fuel detonation is not a credible accident scenario for the SF-BREEZE. For both fuels, we review experiments and theory elucidating the deflagration to detonation transition (DDT). LH 2 fires have a shorter duration than energy-equivalent LNG fires, and produce significantly less thermal radiation. The thermal (infrared) radiation from hydrogen fires is also strongly absorbed by humidity in the air. Hydrogen permeability is not a leak issue for practical hydrogen plumbing. We describe the chemistry of hydrogen and methane at iron surfaces, clarifying their impact on steel-based hydrogen storage and transport materials. These physical, chemical and combustion properties are pulled together in a comparison of how a LH 2 or LNG pool fire on the Top Deck of the SF-BREEZE might influence the structural integrity of the aluminum deck. Neither pool fire scenario leads to net heating of the aluminum decking. Overall, LH 2 and LNG are very similar in their physical and combustion properties, thereby posing similar safety risks. For ships utilizing LH 2 or LNG, precautions are needed to avoid fuel leaks, minimize ignition sources, minimize confined spaces, provide ample ventilation for required confined spaces, and to monitor the enclosed spaces to ensure any fuel accumulation is detected far below the fuel/air mix threshold for any type of combustion.

08 HYDROGEN↗

Mitigation technologies for hydrogen storage systems based on reactive solids.

This paper describes mitigation technologies that are intended to enable the deployment of advanced hydrogen storage technologies for early market and automotive fuel cell applications. Solid State hydrogen storage materials provide an opportunity for a dramatic increase in gravimetric and volumetric energy storage density. Systems and technologies based on the advanced materials have been developed and demonstrated within the laboratory [1,2], and in some cases, integrated with fuel cell systems. The R&D community will continue to develop these technologies for an ever increasing market of fuel cell technologies, including, forklift, light-cart, APU, and automotive systems. Solid state hydrogen storage materials are designed and developed to readily release, and in some cases, react with diatomic hydrogen. This favorable behavior is often accomplished with morphology design (high surface area), catalytic additives (titanium for example), and high purity metals (such as aluminum, Lanthanum, or alkali metals). These favorable hydrogen reaction characteristics often have a related, yet less-desirable effect: sensitivity and reactivity during exposure to ambient contamination and out-of-design environmental conditions. Accident scenarios resulting in this less-favorable reaction behavior must also be managed by the system developer to enable technology deployment and market acceptance. Two important accident scenarios are identified through hazards and risk analysis methods. The first involves a breach in plumbing or tank resulting from a collision. The possible consequence of this scenario is analyzed though experimentally based chemical kinetic and transport modeling of metal hydride beds. An advancing reaction front between the metal hydride and ambient air is observed to proceed throughout the bed. This exothermic reaction front can result in loss of structural integrity of the containing vessel and lead to un-favorable overheating events. The second important accident scenario considered is a pool fire or impinging fire resulting from a collision between a hydrocarbon or hydrogen fueled vehicle. The possible consequence of this scenario is analyzed with experimentally-based numerical simulation of a metal hydride system. During a fire scenario, the hydrogen storage material will rapidly decompose and release hydrogen at high pressure. Accident scenarios initiated by a vehicular collision leading a pipe break or catastrophic failure of the hydride vessel and by external pool fire with flame engulfing the storage vessel are developed using probabilistic modeling. The chronology of events occurring subsequent to each accident initiator is detailed in the probabilistic models. Technology developed to manage these scenarios includes: (1) the use of polymer supports to reduce the extent and rate of reaction with air and water, (2) thermal radiation shielding. The polymer supported materials are demonstrated to provide mitigation of unwanted reaction while not impacting the hydrogen storage performance of the material. To mitigate the consequence of fire engulfment or impingement, thermal radiation shielding is considered to slow the rate of decomposition and delay the potential for loss-of-containment. In this paper we explore the use of these important mitigation technologies for a variety of accident scenarios.

08 HYDROGEN↗

On the reverse flow ceiling jet in pool fire-ventilation crossflow interactions in a simulated aircraft cabin interior

The behavior of the reverse flow ceiling jet against the ventilation flow from 0.58 to 0.87 m/s was investigated in a 1/3 scale model of a wide body aircraft interior. For all tests, strong reverse-flow ceiling jets of hot gases were detected well upstream of the fire. Both thicknesses of the reverse-flow ceiling jet and the smoke layer increased with the fire-crossflow parameter. The thickness of the smoke layer where the smoke flows along the main flow below the reverse-flow ceiling jet was almost twice that of the reverse-flow ceiling jet. Detailed spatial and time-varying temperatures of the gas in the test section were measured, and velocity profiles were also measured using a temperature compensated hot film.

Kwack, E. Y.↗

Model Validation Database for Fires Involving Fuels at Liquefied Natural Gas Facilities

This document provides a description of the model evaluation protocol (MEP) database for fires involving liquefied natural gas (LNG) and processing fuels at LNG facilities. The purpose of the MEP is to provide procedures regarding the assessment of a model's suitability to predict thermal exclusion zones resulting from a fire. The database includes measurements from pool fire, jet fire, and fireball experiments which are provided in a spreadsheet. Users are to enter model results into the spreadsheet which automatically generates statistical performance measures and graphical comparisons with the experimental data. The intent of this document is to provide a description of the experiments and of the procedure required to carry out the validation portion of the MEP. In addition, the statistical performance measures, measurements for comparisons, and parameter variation are provided.

03 NATURAL GAS↗

Model Validation Database for Fires Involving Fuels at Liquefied Natural Gas Facilities (Version 2)

This document provides a description of the model evaluation protocol (MEP) database for fires involving liquefied natural gas (LNG) and processing fuels at LNG facilities. The purpose of the MEP is to provide procedures regarding the assessment of a model’s suitability to predict thermal exclusion zones resulting from a fire. The database includes measurements from pool fire, jet fire, and fireball experiments which are provided in a spreadsheet. Users are to enter model results into the spreadsheet which automatically generates statistical performance measures and graphical comparisons with the experimental data. The intent of this document is to provide a description of the experiments and of the procedure required to carry out the validation portion of the MEP. In addition, the statistical performance measures, measurements for comparisons, and parameter variation are provided.

03 NATURAL GAS↗

Fire tests and analyses of a rail cask-sized calorimeter.

Three large open pool fire experiments involving a calorimeter the size of a spent fuel rail cask were conducted at Sandia National Laboratories Lurance Canyon Burn Site. These experiments were performed to study the heat transfer between a very large fire and a large cask-like object. In all of the tests, the calorimeter was located at the center of a 7.93-meter diameter fuel pan, elevated 1 meter above the fuel pool. The relative pool size and positioning of the calorimeter conformed to the required positioning of a package undergoing certification fire testing. Approximately 2000 gallons of JP-8 aviation fuel were used in each test. The first two tests had relatively light winds and lasted 40 minutes, while the third had stronger winds and consumed the fuel in 25 minutes. Wind speed and direction, calorimeter temperature, fire envelop temperature, vertical gas plume speed, and radiant heat flux near the calorimeter were measured at several locations in all tests. Fuel regression rate data was also acquired. The experimental setup and certain fire characteristics that were observed during the test are described in this paper. Results from three-dimensional fire simulations performed with the Cask Analysis Fire Environment (CAFE) fire code are also presented. Comparisons of the thermal response of the calorimeter as measured in each test to the results obtained from the CAFE simulations are presented and discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal Damage Potential of Electric Vehicles

The main objective is to assess the risk that electric vehicle (EV) battery fires pose regarding thermal damage to other vehicles involved in a crash and to compare EV and internal combustion engine vehicle (ICEV) fires. A literature review of experimental data and statistics are used to perform the assessment. The findings indicate: (1) the heat flux emitted from an EV and ICEV fire are similar due to cabin materials being the main contributor to heat flux, (2) for ICEVs involved in a crash with fuel tank leakage, the thermal damage is significantly more than from an EV fire for equivalent fire durations, (3) the thermal damage potential from ICEV pool fires is at least 5 times higher than EV fires, and (4) EV and ICEV crashes resulting in a fire is about 0.002% and 0.2%, respectively. Thus, EV battery fires have a lower risk than ICEV fires.

33 ADVANCED PROPULSION SYSTEMS↗

Radiant Heating Cookoff Experiments and Predictive Simulations for Fast Cookoff

Thermal initiation (cookoff) of energetic material-laden devices (rocket motors and munitions) during accidental fires is an important safety concern. An article within a pool fire is an example of potential fast cookoff scenerio that has significant potential for a catastrophic result. Beginning in 2007, a collaborative experimental and model development research program under the Joint Munitions Program (JMP) was initiated at SNL/NM to address energetic material response to fast cookoff. The efforts expanded our ongoing research program studying slow cookoff phenomena and sought to answer the key question of "Can our kinetics models derived under slow cookoff conditions be applied to accurately represent energetic material behavior at fast cookoff conditions?" The simplest categorization of slow cookoff is material centered within the energetic material whereas a fast cookoff event is material ignition that occurs at a heated boundary. The external heating rate related to the heat conduction within the energetic material determines the ignition location and thus, the cookoff charaterization of slow or fast. We have developed a benchtop experiment that confines an energetic material sample and exposes it to constant incident heat fluxes common in fire in a controlled and reproducible fashion. Temperatures within the sample near the heated surface are measured using thermocouples and the time-to-event is determined as a function of incident heat flux. Insight and guidance into the experimental development has been provided by one- and three-dimensional simulations of the heat flow paths through the device. Coupling a chemical kinetics model with the heat transfer calculations enable computational predictions of time-to-ignition for comparison to the experimental data. Experimental and predicted data for PBXN-109, PBX-9501, PBX-9502, and Composition B are presented. The final section of this report presents an initial approach aimed at studing the effect of confinement on ignition and sustained reaction.

36 MATERIALS SCIENCE↗

A mathematical model of a large open fire

A mathematical model capable of predicting the detailed characteristics of large, liquid fuel, axisymmetric, pool fires is described. The predicted characteristics include spatial distributions of flame gas velocity, soot concentration and chemical specie concentrations including carbon monoxide, carbon dioxide, water, unreacted oxygen, unreacted fuel and nitrogen. Comparisons of the predictions with experimental values are also given.

Harsha, P. T.↗

The use of computer models to predict temperature and smoke movement in high bay spaces

The Building and Fire Research Laboratory (BFRL) was given the opportunity to make measurements during fire calibration tests of the heat detection system in an aircraft hangar with a nominal 30.4 (100 ft) ceiling height near Dallas, TX. Fire gas temperatures resulting from an approximately 8250 kW isopropyl alcohol pool fire were measured above the fire and along the ceiling. The results of the experiments were then compared to predictions from the computer fire models DETACT-QS, FPETOOL, and LAVENT. In section A of the analysis conducted, DETACT-QS AND FPETOOL significantly underpredicted the gas temperature. LAVENT at the position below the ceiling corresponding to maximum temperature and velocity provided better agreement with the data. For large spaces, hot gas transport time and an improved fire plume dynamics model should be incorporated into the computer fire model activation routines. A computational fluid dynamics (CFD) model, HARWELL FLOW3D, was then used to model the hot gas movement in the space. Reasonable agreement was found between the temperatures predicted from the CFD calculations and the temperatures measured in the aircraft hangar. In section B, an existing NASA high bay space was modeled using the CFD model. The NASA space was a clean room, 27.4 m (90 ft) high with forced horizontal laminar flow. The purpose of this analysis is to determine how the existing fire detection devices would respond to various size fires in the space. The analysis was conducted for 32 MW, 400 kW, and 40 kW fires.

Notarianni, Kathy A.↗

SIERRA Low Mach Module: Fuego Theory Manual (V.4.44)

The SIERRA Low Mach Module: Fuego along with the SIERRA Participating Media Radiation Module: Syrinx, henceforth referred to as Fuego and Syrinx, respectively, are the key elements of the ASCI fire environment simulation project. The fire environment simulation project is directed at characterizing both open large-scale pool fires and building enclosure fires. Fuego represents the turbulent, buoyantly-driven incompressible flow, heat transfer, mass transfer, combustion, soot, and absorption coefficient model portion of the simulation software. Syrinx represents the participating-media thermal radiation mechanics. This project is an integral part of the SIERRA multi-mechanics software development project. Fuego depends heavily upon the core architecture developments provided by SIERRA for massively parallel computing, solution adaptivity, and mechanics coupling on unstructured grids.

97 MATHEMATICS AND COMPUTING↗

SIERRA Low Mach Module: Fuego User Manual (V.4.44)

The SIERRA Low Mach Module: Fuego along with the SIERRA Participating Media Radiation Module: Syrinx, henceforth referred to as Fuego and Syrinx, respectively, are the key elements of the ASCI fire environment simulation project. The fire environment simulation project is directed at characterizing both open large-scale pool fires and building enclosure fires. Fuego represents the turbulent, buoyantly-driven incompressible flow, heat transfer, mass transfer, combustion, soot, and absorption coefficient model portion of the simulation software. Syrinx represents the participating-media thermal radiation mechanics. This project is an integral part of the SIERRA multi-mechanics software development project. Fuego depends heavily upon the core architecture developments provided by SIERRA for massively parallel computing, solution adaptivity, and mechanics coupling on unstructured grids.

97 MATHEMATICS AND COMPUTING↗

SIERRA Low Mach Module: Fuego Theory Manual Version 4.46.

The SIERRA Low Mach Module: Fuego along with the SIERRA Participating Media Radiation Module: Syrinx, henceforth referred to as Fuego and Syrinx, respectively, are the key elements of the ASCI fire environment simulation project. The fire environment simulation project is directed at characterizing both open large-scale pool fires and building enclosure fires. Fuego represents the turbulent, buoyantly-driven incompressible flow, heat transfer, mass transfer, combustion, soot, and absorption coefficient model portion of the simulation software. Syrinx represents the participating-media thermal radiation mechanics. This project is an integral part of the SIERRA multi-mechanics software development project. Fuego depends heavily upon the core architecture developments provided by SIERRA for massively parallel computing, solution adaptivity, and mechanics coupling on unstructured grids.

97 MATHEMATICS AND COMPUTING↗

SIERRA Low Mach Module: Fuego User Manual Version 4.46.

The SIERRA Low Mach Module: Fuego along with the SIERRA Participating Media Radiation Module: Syrinx, henceforth referred to as Fuego and Syrinx, respectively, are the key elements of the ASCI fire environment simulation project. The fire environment simulation project is directed at characterizing both open large-scale pool fires and building enclosure fires. Fuego represents the turbulent, buoyantly-driven incompressible flow, heat transfer, mass transfer, combustion, soot, and absorption coefficient model portion of the simulation software. Syrinx represents the participating-media thermal radiation mechanics. This project is an integral part of the SIERRA multi-mechanics software development project. Fuego depends heavily upon the core architecture developments provided by SIERRA for massively parallel computing, solution adaptivity, and mechanics coupling on unstructured grids.

97 MATHEMATICS AND COMPUTING↗

SIERRA Low Mach Module: Fuego User Manual - Version 4.50

The SIERRA Low Mach Module: Fuego along with the SIERRA Participating Media Radiation Module: Syrinx, henceforth referred to as Fuego and Syrinx, respectively, are the key elements of the ASCI fire environment simulation project. The fire environment simulation project is directed at characterizing both open large-scale pool fires and building enclosure fires. Fuego represents the turbulent, buoyantly-driven incompressible flow, heat transfer, mass transfer, combustion, soot, and absorption coefficient model portion of the simulation software. Syrinx represents the participating-media thermal radiation mechanics. This project is an integral part of the SIERRA multi-mechanics software development project. Fuego depends heavily upon the core architecture developments provided by SIERRA for massively parallel computing, solution adaptivity, and mechanics coupling on unstructured grids.

97 MATHEMATICS AND COMPUTING↗