Search NASA⌕ Search

SEARCH · Search NASA

Results for “Position Sensitive Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Evaluation of a ''CMOS'' Imager for Shadow Mask Hard X-ray Telescope

We have developed a hard x-ray coder that provides high angular resolution imaging capability using a coarse position sensitive image plane detector. The coder consists of two Fresnel zone plates. (FZP) Two such 'FZP's generate Moire fringe patterns whose frequency and orientation define the arrival direction of a beam with respect to telescope axis. The image plane detector needs to resolve the Moire fringe pattern. Pixilated detectors can be used as an image plane detector. The recently available 'CMOS' imager could provide a very low power large area image plane detector for hard x-rays. We have looked into a unit made by Rad-Icon Imaging Corp. The Shadow-Box 1024 x-ray camera is a high resolution 1024xl024 pixel detector of 50x50 mm area. It is a very low power, stand alone camera. We present some preliminary results of our investigation of evaluation of such camera.

Desai, Upendra D.↗

The HEROES Balloon-Borne Hard X-Ray Telescope

The High Energy Replicated Optics to Explore the Sun (HEROES) payload flew on a balloon from Ft. Sumner, NM, September 21-22, 2013. HEROES is sensitive from about 20-75 keV and comprises 8 optics modules (HPD approximately 33" as flown), each consisting of 13-14 nickel replicated optics shells and 8 matching Xenon-filled position-sensitive proportional counter detectors (dE/E=0.05 @ 60 keV). Our targets included the Sun, the Crab Nebula and pulsar and the black hole binary GRS 1915+105. HEROES was pointed using a day/night star camera system for astrophysical observations and a newly developed Solar Aspect System for solar observations (with a shutter protecting the star camera.) We have successfully detected the Crab Nebula. Analyses for GRS 1915+105 and the Sun are ongoing. In this presentation, I will describe the HEROES mission, the data analysis pipeline and calibrations, preliminary results, and plans for follow-on missions.

Wilson-Hodge, C.↗

Recent Developments in Transition-Edge Strip Detectors for Solar X-Rays

LMSAL and NIST are developing position-sensitive x-ray strip detectors based on Transition Edge Sensor (TES) microcalorimeters optimized for solar physics. By combining high spectral (E/ delta E approximately equals 1600) and temporal (single photon delta t approximately equals 10 micro s) resolutions with imaging capabilities, these devices will be able to study high-temperature (>l0 MK) x-ray lines as never before. Diagnostics from these lines should provide significant new insight into the physics of both microflares and the early stages of flares. Previously, the large size of traditional TESs, along with the heat loads associated with wiring large arrays, presented obstacles to using these cryogenic detectors for solar missions. Implementing strip detector technology at small scales, however, addresses both issues: here, a line of substantially smaller effective pixels requires only two TESs, decreasing both the total array size and the wiring requirements for the same spatial resolution. Early results show energy resolutions of delta E(sub fwhm) approximately equals 30 eV and spatial resolutions of approximately 10-15 micron, suggesting the strip-detector concept is viable.

Rausch, Adam J.↗

Position-Sensitive Magnetic Calorimeters for Lynx

We describe the performance of position-sensitive metallic magnetic calorimeter X-ray detectors for potential future astrophysics missions, such as Lynx. The motivation behind this is to achieve a large focal plane area by increasing the number of pixels compared to the number of readout channels (called hydra). The detector consists of a 5×5 array of gold absorbers thermally coupled to a paramagnetic sensor. Since each absorber has a different thermal link to the sensor, it generates a different pulse shape and enables discrimination of pixel position. Recently, we have been successfully able to discriminate 25 averaged pulse shapes by means of rise-time and pulse height. The measured pulse shapes and distribution agree well with the modeling results. The estimated energy resolutions based on the pulse height and noise data we measured are 2.8–3.7 eV for MnKα X-ray photons at 50 mK.

Magnetic calorimeters↗

Remote sensing using solid-state array technology

The paper describes the design features and capabilities of a remote sensor that uses solid-state linear arrays and operates in a 'pushbroom' scan mode to provide the required performance. Pushbroom scanning is a term describing the technique of using the forward motion of a satellite platform to sweep a linear array of detectors oriented perpendicular to the ground track across a scene being imaged. One array is typically used for each spectral channel. Satellite motion provides one direction of scan and electronic sampling of the detectors in the crosstrack dimension provides the orthogonal scan component to form an image. The detector array is sampled at the appropriate rate so that contiguous lines are produced. The performance of a pushbroom system is discussed relative to radiometric sensitivity, detector array geometric fidelity, and radiometric correction. System advantages are precision geometric positioning of the detectors, very high sensitivity and favorable SNR, low power consumption, and no moving optics.

Thompson, L. L.↗

The nuclear and ionic charge distribution particle experiments on the ISEE-1 and ISEE-C spacecraft

The ISEE-1 and ISEE-C instruments are designed to measure the elemental abundances, charge state composition, energy spectra, and angular distributions of energetic ions in the energy range 2 keV/charge to 80 MeV/nucleon and electrons between 75 and 1300 keV. The instrument consists of three sensor systems: (1) ULECA which is an electrostatic deflection system with rectangular solid-state detectors for the 3-560 keV/charge range; (2) ULEWATT which is a double dE/dX vs E thin-window flowthrough proportional counter/solid-state detector telescope for the 0.2-80 MeV/nucleon (Fe) range; and (3) ULEZEQ which is a combination of an electrostatic deflection analyzer and a thin-window dE/dX vs E system with thin-window proportional counter and position-sensitive solid-state detector. The applications of the instruments to solar and interplanetary phenomena and to magnetospheric acceleration and trapped particles are discussed.

Hovestadt, D.↗

Hot shocked gas along the jets of NGC 4258 (M106)

The ROSAT High Resolution Interferometer (HRI) and Position Sensitive Proportional Counter (PSPC) detectors have been used to study the soft X-ray emission of the nearby SABbc galaxy NGC 4258 (M106). The helically twisted, nuclear jets, previously detected in radio continuum and visual emission-line studies, are found to dominate the X-ray images. After correcting pointing errors of up to +/- 7 sec in our HRI observation, we find that the southeast jet is spatially unresolved transversely along much of its 2.5 min (5 kpc) length. The northwest jet is more diffuse, and the extensive radio 'plateaus' also emit X-rays. The energy spectrum of the jets from the PSPC exposure is noisy but is best fitted as a Raymond-Smith plasma with kT = 0.3 keV, log N(sub H) approximately = 20.0/sq cm, and luminosity 1.6 x 10(exp 40) ergs/s between 0.1 and 2.4 keV. Gas at this temperature can arise from planar shocks of 500 km/s and may have been entrained as the jets scrape along the molecular clous that are known to be adjacent to the jets. The range of radial velocities from our published visual emission-line spectra of the jet are consistent with such a shock speed. We estimate that the mass of hot gas in the jets is 6 x 10(exp 4) (1/cc/n(sub e)) solar mass, with n(sub e) the average electron density. The inferred pressure of hot gas in the southeast jet may be similar to the radio equipartition pressure and to the ambient pressure of the interstellar medium (ISM). The X-ray spectral fit is poor above 0.7 keV and requires an additional hard component that peaks near the nucleus.

Cecil, G.↗

Prospects for Observing and Localizing Gravitational-Wave Transients with Advanced LIGO and Advanced Virgo

We present a possible observing scenario for the Advanced LIGO and Advanced Virgo gravitational-wave detectors over the next decade, with the intention of providing information to the astronomy community to facilitate planning for multi-messenger astronomy with gravitational waves. We determine the expected sensitivity of the network to transient gravitational-wave signals, and study the capability of the network to determine the sky location of the source. We report our findings for gravitational-wave transients, with particular focus on gravitational-wave signals from the inspiral of binary neutron-star systems, which are considered the most promising for multi-messenger astronomy. The ability to localize the sources of the detected signals depends on the geographical distribution of the detectors and their relative sensitivity, and 90% credible regions can be as large as thousands of square degrees when only two sensitive detectors are operational. Determining the sky position of a significant fraction of detected signals to areas of 5 sq. deg to 20 sq. deg will require at least three detectors of sensitivity within a factor of approximately 2 of each other and with a broad frequency bandwidth. Should the third LIGO detector be relocated to India as expected, a significant fraction of gravitational-wave signals will be localized to a few square degrees by gravitational-wave observations alone.

counterparts↗

Development of a fast ion mass spectrometer for space research

An ion mass spectrometer having a cylindrical E bar x B bar analyzer and either a cylindrical or spherical electrostatic analyzer is described. The instrument has two nested channels and a postacceleration between the electrostatic and E bar x B bar analyzers for wide ranges of energy and mass responses. It is noted that the dual-channel construction not only doubles the data acquisition rate but also permits a reversal of the electrostatic field orientation in the inner channel for lighter ions. The outer channel is then optimized for ions of medium to high mass numbers, resulting in increased mass resolution for such heavy ions. When combined with a cylindrical E bar x B bar analyzer, a 90-deg-deflection angle spherical electrostatic analyzer provides an extremely wide viewing angle. The angular distribution of ions can be derived from such geometry if a position-sensitive resistive anode or a detector array is used at the exit aperture. Details on the principles of operation, the instrument design, and calibration are presented.

Hahn, S. F.↗

Studies with the Pinhole/Occulter Facility

The scientific justifications for high-resolution hard X-ray astronomy are reviewed, and a scheme for making such observations from the Space Shuttle payload bay is presented. High-resolution X-ray observations at photon energies above 10 keV are important for the understanding of the physics of solar flares, coronal disturbances related to flares, and corona fine structure, as well as nonsolar X-ray sources. In order to study these phenomena, concepts have been developed for the Shuttle Pinhole/Occulter Facility (P/OF), an instrument based on the principles of the pinhole camera which will have an angular resolution of 0.2 arc sec. The proposed P/OF configuration consists of four separate telescopes or position-sensitive counters mounted on a detector plane and looking toward the target through separate portions of an aperture mask (occulter plane). The two planes are separated by a self-deployable 50-m boom, which is to be made essentially rigid by direct control of its lowest normal modes.

Tandberg-Hanssen, E.↗

High throughput non-dispersive hard X-ray spectrograph with angular resolution for cosmic bursts, transients, and sources

An instrument concept which offers high throughput nondispersive spectroscopy in the 35-150 keV band for measuring line intensities and widths of faint supernovae is described. The design is based on existing xenon filled, two-dimensional, position sensitive, multiwired proportional counters. Effective detector areas of 1000 sq cm are readily achievable, and expansion to 10,000 sq cm per unit is feasible. Either single-unit or array operation to provide all-sky coverage with one arcmin resolution is possible. The instrument could be used to record gamma ray bursts and would have the capability of distinguishing particle events. Observations could also be made of X ray cyclotron lines and the Ti-44 lines expected to issue from a supernova explosion.

Gorenstein, P.↗

Future progress in the development of the Lixiscope

Some of the potential of the lixiscope in astrophysics as well as in space medicine are reported. The positioning of the lixiscope as a sensitive detector placed at the focal plane of a focusing or collimating X-ray telescope, and studies of the inter-coastal spacing during weightlessness are described.

Trombka, J. I.↗

Construction and evaluation of an imaging focussed-mesh electron multiplier for space instrumentation

A focused-mesh electron multiplier (FMEM) has been combined with a wedge and strip position-sensitive anode to create a novel detector that is considered likely to have a number of applications in space astronomy and laboratory image sensing. Results from the first application of a wedge and strip anode to an FMEM are presented including spatial resolution, spatial linearity, background rate, and pulse risetime. The converted multiplier retains the attributes of an FMEM that made it attractive in the first place, such as low background, high speed, and high dynamic range.

Vallerga, J.↗

In Situ Mineralogical Analysis of Planetary Materials Using X-Ray Diffraction and X-Ray Fluorescence

Remote observations of Mars have led scientists to believe that its early climate was similar to that of the early Earth, having had abundant liquid water and a dense atmosphere. One of the most fascinating questions of recent times is whether simple bacterial life developed on Mars (as it did on the Earth) during this early element period. Analyses of SNC meteorites have broadened considerably our knowledge of the chemistry of certain types of Martian rocks, underscoring the tantalizing possibility of early hydrothermal systems and even of ancient bacterial life. Detailed analyses of SNC meteorites in Terrestrial laboratories utilize the most sophisticated organic, isotopic and microscopic techniques in existence. Indeed; it is unlikely that the key biogenic indicators used in McKay et al (ibid) could be identified by a remote instrument on the surface of Mars. As a result, it is probable that any robotic search for evidence of an ancient Martian biosphere will have as its focus the identification of key minerals in likely host rocks rather than the direct detection of organic or isotopic biomarkers. Even on a sample return mission, mineralogical screening will be utilized to choose the most likely candidate rocks. X-ray diffraction (XRD) is the only technique that can provide a direct determination of the crystal structures of the phases present within a sample. When many different crystalline phases are present, quantitative analysis is better constrained if used in conjunction with a determination of elemental composition, obtainable by X-ray fluorescence (XRF) using the same X-ray source as for XRD. For planetary surface analysis, a remote instrument combining XRD and XRF could be used for mineralogical characterization of both soils and rocks. We are designing a remote XRD/XRF instrument with this objective in mind. The instrument concept pays specific attention to constraints in sample preparation, weight, volume, power, etc. Based on the geometry of a pinhole camera (transmission geometry, flat two-dimensional detector perpendicular to the direct beam), the instrument (which we call CHEMIN, for Chemistry and Mineralogy) uses an X-ray sensitive CCD detector which will allow concurrent positional and energy-dispersive analysis of collected photons. Thus XRF (energy) and XRD (geometry) analysis of transmitted X-rays will be performed at the same time. Tests performed with single minerals and simple mixtures give promising results. Refinements of the prototype promise interpretable results on complex samples.

Sarrazin, P.↗

Implementation of Complex Signal Processing Algorithms for Position-Sensitive Microcalorimeters

We have recently reported on a theoretical digital signal-processing algorithm for improved energy and position resolution in position-sensitive, transition-edge sensor (POST) X-ray detectors [Smith et al., Nucl, lnstr and Meth. A 556 (2006) 2371. PoST's consists of one or more transition-edge sensors (TES's) on a large continuous or pixellated X-ray absorber and are under development as an alternative to arrays of single pixel TES's. PoST's provide a means to increase the field-of-view for the fewest number of read-out channels. In this contribution we extend the theoretical correlated energy position optimal filter (CEPOF) algorithm (originally developed for 2-TES continuous absorber PoST's) to investigate the practical implementation on multi-pixel single TES PoST's or Hydras. We use numerically simulated data for a nine absorber device, which includes realistic detector noise, to demonstrate an iterative scheme that enables convergence on the correct photon absorption position and energy without any a priori assumptions. The position sensitivity of the CEPOF implemented on simulated data agrees very well with the theoretically predicted resolution. We discuss practical issues such as the impact of random arrival phase of the measured data on the performance of the CEPOF. The CEPOF algorithm demonstrates that full-width-at- half-maximum energy resolution of < 8 eV coupled with position-sensitivity down to a few 100 eV should be achievable for a fully optimized device.

Smith, Stephen J.↗

The Hard X ray Telescope Mission

The Hard X Ray Telescope (HXT) was selected for study as a possible new intermediate size mission for the early 21st century. Its principal attributes are: (1) multiwavelength observing with a system of focussing telescopes that collectively observe from the UV to over 1 MeV, (2) much higher sensitivity and much better angular resolution in the 10100 keV band, and (3) higher sensitivity for detecting gamma ray lines of known energy in the 100 keV to 1 MeV band. The institutions collaborating in the study are: Smithsonian Astrophysical Observatory, Marshall Space Flight Center, Naval Research Laboratory, Goddard Space Flight Center, Argonne National Laboratory, Danish Space Research Institute, Osservatorio Astronomica di Brera (Merate), and Centre d'Etudes Spatiale des Rayonnements (Toulouse). The instrumentation includes several grazing incidence double conical telescopes with multilayer coatings that focus up to 100 keV and a single Laue crystal telescope that functions to 1 MeV. The detectors are CCDs, and germanium, and/or CdZnTe position sensitive arrays.

Gorenstein, Paul↗

Sensors for Precise Tracking

Sun-sensor optical system uses four pairs of pentaprisms to simplify alinement and reduce mechanical-stability requirements. Cross-shaped windows in field stop enhance sensitivity of signal detectors to changes in angular position. Two virtual images viewed by telescopes mark position and orientation of occulter panel. Reflector vertex, point source and corresponding virtual image are all equally spaced along a straight line.

Zehnpfenning, T. F.↗

Electron tunnel sensor technology

The recent development of Scanning Tunneling Microscopy technology allows the application of electron tunneling to position detectors for the first time. The vacuum tunnel junction is one of the most sensitive position detection mechanisms available. It is also compact, simple, and requires little power. A prototype accelerometer based on electron tunneling, and other sensor applications of this promising new technology are described.

Waltman, S. B.↗