Search NASA⌕ Search

SEARCH · Search NASA

Results for “Position-sensitive detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

106 records · Page 6

Thermal links and position resolution in multi-absorber hydra microcalorimeters

The “hydra” style of position-sensitive, multi-absorber microcalorimeter is used in some imaging x-ray spectroscopy detector arrays to thermally multiplex multiple pixels to one sensor, thereby enabling readout of larger arrays for a given number of sensor readout channels. We describe the benefit of choosing a set of thermal conductance values for the links between absorbers and sensor such that the probability of misidentifying the absorber hit location is minimized while still achieving a specified x-ray energy resolution for all pixels. We illustrate the benefit of this approach as applied in our current prototype 25-pixel hydra magnetic microcalorimeter arrays for the Lynx x-ray astrophysics mission concept.

microcalorimeter↗

A Call to Arms Control: Synergies between Nonproliferation Applications of Neutrino Detectors and Large-Scale Fundamental Neutrino Physics Experiments (A Snowmass White Paper)

The High Energy Physics community can benefit from a natural synergy in research activities into next-generation large-scale water and scintillator neutrino detectors, now being studied for remote reactor monitoring, discovery and exclusion applications in cooperative nonproliferation contexts. Since approximately 2010, US nonproliferation researchers, supported by the National Nuclear Security Administration (NNSA), have been studying a range of possible applications of relatively large (100 ton) to very large (hundreds of kiloton) water and scintillator neutrino detectors. In parallel, the fundamental physics community has been developing detectors at similar scales and with similar design features for a range of high-priority physics topics, primarily in fundamental neutrino physics. These topics include neutrino oscillation studies at beams and reactors, solar, and geological neutrino measurements, supernova studies, and others. Examples of ongoing synergistic work at U.S. national laboratories and universities include prototype gadolinium-doped water and water-based and opaque scintillator test-beds and demonstrators, extensive testing and industry partnerships related to large area fast position-sensitive photomultiplier tubes, and the development of concepts for a possible underground kiloton-scale water-based detector for reactor monitoring and technology demonstrations. Some opportunities for engagement between the two communities include bi-annual Applied Antineutrino Physics conferences, collaboration with U.S. National Laboratories engaging in this research, and occasional NNSA funding opportunities supporting a blend of nonproliferation and basic science R&D, directed at the U.S. academic community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A High-Pressure Gas-Scintillation-Proportional Counter for the Focus of a Hard-X-Ray Telescope

We are developing a high-pressure Gas Scintillation Proportional Counter (GSPC) for the focus of a balloon-borne hard-x-ray telescope. The device has a total active diameter of 50 mm, of which the central 20 mm only is used, and is filled with xenon + 4% helium at a total pressure of 10 6 Pa giving a quantum efficiency of greater than 85% up to 60 keV. The detector entrance is sealed with a beryllium window, 3-mm thick, which provides useful transmission down to 6 keV, way below the atmospheric cut-off at balloon float altitudes. Scintillation light exits the detector via a UV transmitting window in its base and is registered by a Hamamatsu position-sensitive crossed-grid-readout photomultiplier tube. Initial testing is underway, quantifying light yield and energy resolution. Following that, the spatial resolution and absolute efficiency will be calibrated. Simulations show that a spatial resolution of better than 0.5 mm FWHM should be achievable up to 60 keV, and this is well matched to the angular resolution and plate scale of the mirror system. The energy resolution will be around 5% at 22 keV. Full details of the instrument design and its performance will be presented. A first flight is scheduled for the Fall of 99, on a stratospheric balloon to be launched from Fort Sumner, New Mexico.

Austin, R. A.↗

Upgrades to the TRIUMF Fast Ion Counter, TRIFIC

TRIFIC, the TRIUMF Fast Ion Counter, is a downstream ionization chamber which provides beam composition monitoring and recoil tagging for in-beam reaction experiments. TRIFIC has been commissioned and deployed for use with radioactive isotope beams at the TRIUMF-ISAC facility. Recently, the detector has been upgraded to include an improved gas window that can accommodate higher beam rates and position-sensitive electrode grids for better position reconstruction.

Gaseous detectors↗

Half-life measurement of the 199-keV isomeric state in Ga 76

Background: Isomeric states in atomic nuclei are a sensitive probe of their underlying microscopic structure and can be used to study the evolution of shell structure far from stability. Recent studies have identified and provided detailed spectroscopy of isomers in neutron-rich nuclei with Z = 28-50. Isomeric states in the odd-odd gallium isotopes have been reported for all gallium isotopes from A = 72 to A = 80 with the exception of 76 Ga. Purpose: The purpose of this experiment was to observe short-lived isomeric states in the vicinity of 78 Ni. Methods: In-beam fragmentation of a 86 Kr primary beam at the National Superconducting Cyclotron Laboratory produced radioactive ions which were delivered to and deposited in a Ce Br 3 scintillator coupled to a position-sensitive photomultiplier tube. Beta-delayed γ rays were measured by ancillary HPGe clover and LaBr 3 detectors which surrounded the implantation detector. Results: The previously observed J π = 1 + , 199-keV level in 76 Ga, populated following the β decay of 76 Zn, was identified as isomeric with a half-life of 34(1) stat. (8) sys. ns. Shell-model calculations suggest this state is formed by the coupling of protons in negative-parity configurations to 1/2 - neutron configurations. Transition strengths assuming a ground-state spin of J = 2 and J = 3 were determined from the experimental data.

59 ≤ A ≤ 89↗

Theory and Development of Position-Sensitive Quantum Calorimeters

Quantum calorimeters are being developed as imaging spectrometers for future X-ray astrophysics observatories. Much of the science to be done by these instruments could benefit greatly from larger focal-plane coverage of the detector (without increasing pixel size). An order of magnitude more area will greatly increase the science throughput of these future instruments. One of the main deterrents to achieving this goal is the complexity of the readout schemes involved. We have devised a way to increase the number of pixels from the current baseline designs by an order of magnitude without increasing the number of channels required for readout. The instrument is a high energy resolution, distributed-readout imaging spectrometer called a Position-Sensitive Transition-Edge Sensor (POST). A POST is a quantum calorimeter consisting of two Transition-Edge Sensors (TESS) on the ends of a long absorber capable of one-dimensional imaging spectroscopy. Comparing rise time and energy information from the two TESS, the position of the event in the POST is determined. The energy of the event is inferred from the sum of the two pulses. We have developed a generalized theoretical formalism for distributed-readout calorimeters and apply it to our devices. We derive the noise theory and calculate the theoretical energy resolution of a POST. Our calculations show that a 7-pixel POST with 6 keV saturation energy can achieve 2.3 eV resolution, making this a competitive design for future quantum calorimeter instruments. For this thesis we fabricated 7- and 15-pixel POSTS using Mo/Au TESs and gold absorbers, and moved from concept drawings on scraps of napkins to a 32 eV energy resolution at 1.5 keV, 7-pixel POST calorimeter.

Figueroa-Feliciano, Enectali↗

Improving Chirped Fiber Bragg Grating Resolution for Position-Sensitive Sensors in Shock- and Detonation-Driven Experiments

Chirped fiber Bragg gratings (CFBGs) are robust diagnostic sensors that are widely used to track detonation-driven and shock wave propagation. CFBGs are inscribed with a linearly chirped periodic index of refraction changes that alter the Bragg wavelength along the length of the probe. The light return of each individual Bragg element is captured by a detector at a unique time to map the full reflected spectrum. The CFBG spectrum is measured with a dispersive Fourier transform of the reflected light that temporally stretches the spectrum to increase spatial resolution and make a one-to-one map of the wavelength on a time axis. Here, we propose an improvement of CFBG temporal resolution by incorporating two co-linear laser pulses with orthogonal polarization states and a 5 ns time offset. The two separate signals were split and tracked by two separate detectors. An oscilloscope captured good separation in the signals, and two separate spectrograms were generated and interleaved in the post-processing of the data. This novel technique doubled the CFBG temporal resolution and led to a doubled location resolution. As a proof-of-concept of this technique, the resolution improvement was compared between standard CFBG measurements and the two polarization states method on a position-sensitive CFBG sensor. CFBG resolution doubling will advance sensor capabilities and will have a direct impact on improving capture and analysis in dynamic, high-explosive experiments.

42 ENGINEERING↗

Gas Scintillation Proportional Counters for High-Energy X-ray Astronomy

A focal plane array of high-pressure gas scintillation proportional counters (GSPC) for a balloon-borne hard-x-ray telescope is under development at the Marshall Space Flight Center. These detectors have an active area of approx. 20 sq cm, and are filled with a high pressure (10(exp 6) Pa) xenon-helium mixture. Imaging is via crossed-grid position-sensitive phototubes sensitive in the UV region. The performance of the GSPC is well matched to that of the telescopes x-ray optics which have response to 75 keV and a focal spot size of approx. 500 microns. The detector s energy resolution, 4% FWHM at 60 keV, is adequate for resolving the broad spectral lines of astrophysical importance and for accurate continuum measurements. Full details of the instrument and its performance will be provided.

Gubarev, Mikhail↗

Performance of Gas Scintillation Proportional Counter Array for High-Energy X-Ray Observatory

A focal plane array of high-pressure gas scintillation proportional counters (GSPC) for a High Energy X-Ray Observatory (HERO) is developed at the Marshall Space Flight Center. The array is consisted from eight GSPCs and is a part of balloon born payload scheduled to flight in May 2004. These detectors have an active area of approximately 20 square centimeters, and are filled with a high pressure (10(exp 6) Pa) xenon-helium mixture. Imaging is via crossed-grid position-sensitive phototubes sensitive in the UV region. The performance of the GSPC is well matched to that of the telescopes x-ray optics which have response to 75 keV and a focal spot size of approximately 500 microns. The detector's energy resolution, 4% FWHM at 60 keV, is adequate for resolving the broad spectral lines of astrophysical importance and for accurate continuum measurements. Results of the on-earth detector calibration will be presented and in-flight detector performance will be provided, as available.

Gubarev, Mikhail↗

A position sensitive microchannel photomultiplier for ultraviolet space astronomy

The 25-mm microchannel-plate, position-sensitive UV astronomy photomultiplier tube presented is intended for the EOM-1 Spacelab Mission's FAUST payload and conducts wide-field imaging surveys in the VUV over the 1400-1800-A range. The sealed detector encompasses a CsI photocathode deposited on the inner surface of a MgF2 window, a stack of microchannel plates, and a wedge-and-strip two-dimensional position-sensing anode. Since the wedge-and-strip principle requires only three anode signals, flight electronics can be reduced to three charge amplifiers and three analog-to-digital converters.

Lampton, M.↗

An imaging proportional counter for a 0.1 to 10 keV X-ray telescope

A xenon multiwire position-sensitive proportional counter (PSPC) with a high degree of long-term stability has been constructed and tested in detail. It is suitable for a 0.1 to 10 keV X-ray telescope such as AXAF, which it would share with detectors having better spatial and spectral resolution. Compared to other detectors, the larger format, higher quantum efficiency, and lower background of the PSPC makes it generally the most useful instrument for observations of diffuse cosmic X-ray sources and associations of sources more extended than a few tenths of a degree in diameter. Given the good spatial linearity, the systematic uncertainty for source locations is finer than an arcsecond. The spatial resolution varies as 0.3 mm/exp 0.5 (keV) over the range 0.2-4 keV, in accordance with theoretical limits determined by the size and the number of electrons in the primary charge cloud.

Gorenstein, P.↗

Theoretical Noise Analysis on a Position-sensitive Metallic Magnetic Calorimeter

We report on the theoretical noise analysis for a position-sensitive Metallic Magnetic Calorimeter (MMC), consisting of MMC read-out at both ends of a large X-ray absorber. Such devices are under consideration as alternatives to other cryogenic technologies for future X-ray astronomy missions. We use a finite-element model (FEM) to numerically calculate the signal and noise response at the detector outputs and investigate the correlations between the noise measured at each MMC coupled by the absorber. We then calculate, using the optimal filter concept, the theoretical energy and position resolution across the detector and discuss the trade-offs involved in optimizing the detector design for energy resolution, position resolution and count rate. The results show, theoretically, the position-sensitive MMC concept offers impressive spectral and spatial resolving capabilities compared to pixel arrays and similar position-sensitive cryogenic technologies using Transition Edge Sensor (TES) read-out.

Smith, Stephen J.↗

NASA Tech Briefs, July 2011

Topics covered include: 1) Collaborative Clustering for Sensor Networks; 2) Teleoperated Marsupial Mobile Sensor Platform Pair for Telepresence Insertion Into Challenging Structures; 3) Automated Verification of Spatial Resolution in Remotely Sensed Imagery; 4) Electrical Connector Mechanical Seating Sensor; 5) In Situ Aerosol Detector; 6) Multi-Parameter Aerosol Scattering Sensor; 7) MOSFET Switching Circuit Protects Shape Memory Alloy Actuators; 8) Optimized FPGA Implementation of Multi-Rate FIR Filters Through Thread Decomposition; 9) Circuit for Communication Over Power Lines; 10) High-Efficiency Ka-Band Waveguide Two-Way Asymmetric Power Combiner; 11) 10-100 Gbps Offload NIC for WAN, NLR, and Grid Computing; 12) Pulsed Laser System to Simulate Effects of Cosmic Rays in Semiconductor Devices; 13) Flight Planning in the Cloud; 14) MPS Editor; 15) Object-Oriented Multi Disciplinary Design, Analysis, and Optimization Tool; 16) Cryogenic-Compatible Winchester Connector Mount and Retaining System for Composite Tubes; 17) Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy; 18) Planar Rotary Piezoelectric Motor Using Ultrasonic Horns; 19) Self-Rupturing Hermetic Valve; 20) Explosive Bolt Dual-Initiated from One Side; 21) Dampers for Stationary Labyrinth Seals; 22) Two-Arm Flexible Thermal Strap; 23) Carbon Dioxide Removal via Passive Thermal Approaches; 24) Polymer Electrolyte-Based Ambient Temperature Oxygen Microsensors for Environmental Monitoring; 25) Pressure Shell Approach to Integrated Environmental Protection; 26) Image Quality Indicator for Infrared Inspections; 27) Micro-Slit Collimators for X-Ray/Gamma-Ray Imaging; 28) Scatterometer-Calibrated Stability Verification Method; 29) Test Port for Fiber-Optic-Coupled Laser Altimeter; 30) Phase Retrieval System for Assessing Diamond Turning and Optical Surface Defects; 31) Laser Oscillator Incorporating a Wedged Polarization Rotator and a Porro Prism as Cavity Mirror; 32) Generic, Extensible, Configurable Push-Pull Framework for Large-Scale Science Missions; 33) Dynamic Loads Generation for Multi-Point Vibration Excitation Problems; 34) Optimal Control via Self-Generated Stochasticity; 35) Space-Time Localization of Plasma Turbulence Using Multiple Spacecraft Radio Links; 36) Surface Contact Model for Comets and Asteroids; 37) Dust Mitigation Vehicle; 38) Optical Coating Performance for Heat Reflectors of the JWST-ISIM Electronic Component; 39) SpaceCube Demonstration Platform; 40) Aperture Mask for Unambiguous Parity Determination in Long Wavelength Imagers; 41) Spaceflight Ka-Band High-Rate Radiation-Hard Modulator; 42) Enabling Disabled Persons to Gain Access to Digital Media; 43) Cytometer on a Chip; 44) Principles, Techniques, and Applications of Tissue Microfluidics; and 45) Two-Stage Winch for Kites and Tethered Balloons or Blimps.

Source record↗

CHICOX, a heavy-ion detection system for GRETA

The CHICOX detection system is an array of position sensitive parallel plate avalanche counters used for heavy ion detection in in-beam particle-gamma coincidence experiments. CHICOX, an upgrade of the CHICO2 array, is geometrically compatible with the GRETINA and GRETA gamma-ray arrays and provides an angular resolution sufficient to utilize the excellent position resolution of GRETINA/GRETA. CHICOX was successfully commissioned and fielded as an auxiliary detector to GRETINA in a campaign of stable-beam Coulomb excitation experiments at the ATLAS facility of Argonne National Laboratory. We report here on the design and in-beam performance of the CHICOX array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser beam pointing stabilization using analog position-sensitive diodes

Laser wire scanners have been used for ion beam profile and emittance measurements at the Spallation Neutron Source linear accelerator. Due to propagation distances exceeding 100 m, reliable measurements require laser beam stabilization, previously accomplished with a feedback control loop using a digital camera as a position sensor [Hardin et al., Opt. Express 19, 2874 (2011)]. Here, this paper presents an upgraded pointing stabilization system utilizing analog position-sensitive diodes (PSDs) as the position detector, optimized with an optical diffuser. The new system significantly surpasses the previous system by offering an order-of-magnitude improvement in radiation tolerance and a bandwidth limited only by the burst repetition rate of the laser beam. Operating with a 60-Hz burst mode laser, the new system effectively suppresses laser beam drifts up to 30 Hz, compared to the previous system’s 4 Hz limit. In addition, the amplitude of spectral components below 0.1 Hz was reduced by a factor of more than 100, which is over seven times greater than was achieved by the previous system.

Data acquisition↗

Multi-Absorber Transition-Edge Sensors for X-Ray Astronomy Applications

We are developing multi-absorber Transition-Edge Sensors (TESs) for applications in x-ray astronomy. These position-sensitive devices consist of multiple x-ray absorbers each with a different thermal coupling to a single readout TES. Heat diffusion between the absorbers and the TES gives rise to a characteristic pulse shape corresponding to each absorber element and enables position discrimination. The development of these detectors is motivated by a desire to maximize focal plane arrays with the fewest number of readout channels. In this contribution we report on the first results from devices consisting of nine) 65 X 65 sq. microns Au x-ray absorbers) 5 microns thick. These are coupled to a single 35 X 35 sq. microns Mo/Au bilayer TES. These devices have demonstrated full-width-half-maximum (FWHM) energy resolution of 2.1 eV at 1.5 keV) 2.5 eV at 5.9 keV and 3.3 eV at 8 keV. This is coupled with position discrimination from pulse shape over the same energy range. We use a finite-element model to reproduce the measured pulse shapes and investigate the detector non-linearity with energy) which impacts on the devices position sensitivity and energy resolution.

Smith, S. J.↗