Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positrons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Positron annihilation lifetime spectroscopy study of polyvinylpyrrolidone‐added polyvinylidene fluoride membranes: Investigation of free volume and permeation relationships

ABSTRACT Polyvinylidene fluoride (PVDF) membranes were prepared via the phase inversion method from casting solutions containing PVDF, dimethylformamide (DMF), and polyvinylpyrrolidone (PVP) as pore former. PVP was used in the casting solution in a range of 0–5 wt % and extracted. The effect on membranes of using PVP in the casting process was analyzed by X‐ray diffraction, differential scanning calorimetry, scanning electron microscopy, viscosity, and water permeability techniques. With an increase of PVP from 0 to 5 wt %, the PVDF casting solution viscosities increased from 858 to 1148 cP; the resulting PVDF membrane thickness increased; and the crystallinity of PVDF membranes decreased from 40.0 to 33.3%, which indicates that the addition of PVP inhibits the degree of crystallization in the PVDF membranes. SEM results revealed the shape and size of macropores in the membranes; these macropores changed after PVP addition to the casting solutions. The impact of structural changes on free‐volume properties was evaluated using positron annihilation lifetime spectroscopy (PALS) studies. PALS analysis indicated no effect on the average radius (~3.4 Å) of membrane free‐volume holes from the addition of PVP to the casting solution. However, the percentage of o ‐Ps pick‐off annihilation intensity, I 3 , increased from 1.7 to 5.1% with increased PVP content. Further, increasing the PVP content from 0.5 to 5% resulted in an increased final pure water permeability flux. For instance, the 210 min flux for a 14% PVDF + 0.5% PVP membrane was found to be 3.3 times greater than a control membrane having the same PVDF concentration. © 2020 Wiley Periodicals, Inc. J. Polym. Sci. 2020 , 58 , 589–598

Eren, Bilge↗

Scale-fixed predictions for γ + η c production in electron-positron collisions at NNLO in perturbative QCD

In the paper, we present QCD predictions for γ + η c production at an electron-positron collider up to next-to-next-to-leading order (NNLO) accuracy without renormalization scale ambiguities. The NNLO total cross-section for e + + e – → γ + η c using the conventional scale-setting approach has large renormalization scale ambiguities, usually estimated by choosing the renormalization scale to be the e + e – center-of-mass collision energy $\sqrt{s}$. The Principle of Maximum Conformality (PMC) provides a systematic way to eliminate such renormalization scale ambiguities by summing the nonconformal β contributions into the QCD coupling α s ( Q 2 ). The renormalization group equation then sets the value of α s for the process. The PMC renormalization scale reflects the virtuality of the underlying process, and the resulting predictions satisfy all of the requirements of renormalization group invariance, including renormalization scheme invariance. After applying the PMC, we obtain a renormalization scale-and-scheme independent prediction, σ | NNLO,PMC ≃ 41.18 fb for $\sqrt{s}$=10.6 GeV. The resulting pQCD series matches the series for conformal theory and thus has no divergent renormalon contributions. The large K factor which contributes to this process reinforces the importance of uncalculated NNNLO and higher-order terms. Using the PMC scale-and-scheme independent conformal series and the Padé approximation approach, we predict σ | NNNLO,PMC+Pade ≃ 18.99 fb, which is consistent with the recent BELLE measurement ${\sigma}^{\mathrm{obs}}={16.58}_{-9.93}^{+10.51}$ fb at $\sqrt{s}$ ≃ 10.6 GeV. This procedure also provides a first estimate of the NNNLO contribution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrated positron emission particle tracking (PEPT) and X-ray computed tomography (CT) imaging of flow phenomena in twisted tape swirl flow

Abstract A combined positron emission particle tracking (PEPT) and X-ray computed tomography (CT) technique is presented, and its utility is demonstrated through investigation of flow in a pipe with twisted tape swirl insert with varying flow conditions (diameter-based Reynolds numbers 16,300–63,300). A description of this technique is given, as well as data handling practices used to relate geometric information captured by CT to fluid flow data gathered via PEPT. It is found that the CT component is readily capable of capturing the stainless steel insert geometry in this present system, but the use of combined plastic and metal materials leads to artifacts in imaging of the plastic surface. Nonetheless, CT data are related to PEPT flow measurements, and average velocity fields are calculated via a pseudo-framing and interpolation scheme and used to visualize and interrogate key flow phenomena within the system. Radial velocity profiles of the mean flow characteristics are seen to collapse to a nearly common form across all flow conditions considered. Helical vortices are seen propagating through the flow field, generated by bypass flow around the gap between the insert and pipe wall, with additional coherent secondary flow structures seen in the higher Reynolds number cases. These findings enhance the understanding of the mixing mechanisms in these swirl flows and encourage the continued development of PEPT-CT methodologies for 3D flow measurements in optically inaccessible systems.

42 ENGINEERING↗

CsI(Tl) pulse shape discrimination with the Belle II electromagnetic calorimeter as a novel method to improve particle identification at electron–positron colliders

Here we describe the implementation and performance of CsI(Tl) pulse shape discrimination for the Belle II electromagnetic calorimeter, representing the first application of CsI(Tl) pulse shape discrimination for particle identification at an electron–positron collider. The pulse shape characterization algorithms applied by the Belle II calorimeter are described. Control samples of $γ, μ^+, π^±, K^±$ and $ρ/ \bar{ρ}$ are used to demonstrate the significant insight into the secondary particle composition of calorimeter clusters that is provided by CsI(Tl) pulse shape discrimination. Comparisons with simulation are presented and provide further validation for newly developed CsI(Tl) scintillation response simulation techniques, which when incorporated with GEANT4 simulations allow the particle dependent scintillation response of CsI(Tl) to be modelled. Comparisons between data and simulation also demonstrate that pulse shape discrimination can be a new tool to identify sources of improvement in the simulation of hadronic interactions in materials. The $K^0_L$ efficiency and photon-as-hadron fake-rate of a multivariate classifier that is trained to use pulse shape discrimination is presented and comparisons are made to a shower-shape based approach. CsI(Tl) pulse shape discrimination is shown to reduce the photon-as-hadron fake-rate by over a factor of 3 at photon energies of 0.2 GeV and over a factor 10 at photon energies of 1 GeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of a positron-emission-tomography-based SiPM readout for compact segmented neutron imagers

Gamma-ray emission from special nuclear material (SNM) is relatively easy to shield from detection using modest amounts of high-Z material. In contrast, fast-neutrons are much more penetrating and can escape relatively thick high-Z shielding without losing significant energy. Furthermore, fast neutrons provide a clear and unambiguous signature of the presence of SNM with few competing natural background sources. The challenge of detecting fast neutrons is twofold. First, the neutron flux from SNM are only a fraction of the corresponding gamma-ray flux. Second, fast neutrons can be difficult to differentiate from gamma rays. The ability to discriminate gamma rays from neutrons, combined with a neutron imaging capability, can in some situations enable the localization of SNM neutron sources distinct from background. With the developments of pulse-shape-sensitive plastic scintillators that offer excellent gamma-ray/neutron discrimination, and arrays of silicon photomultipliers combined with highly scalable and fast positron-emission-tomography (PET) multi-channel readout systems, field-deployable neutron imagers suitable for SNM detection might now be within reach. In this paper, we present a characterization of the performance of a recently available commercial PET-scanner readout, including its sensitivity to pulse-shape differences between fast neutrons and gamma rays, energy and timing resolution. Here, we find that, while the pulse-shape discrimination is achievable with stilbene, further improvement of the readout is required to achieve it with the PSD-capable available plastic scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron-positron pair creation in the electric fields generated by micro-bubble implosions

Here, we show that electron-positron pair production from the vacuum is possible via the strong Coulomb fields generated by micro-bubble implosions induced by ultra-high intensity lasers. Even in the case where the Coulomb fields are lower than the pair creation threshold, externally injected high energy electrons or photons could be used to generate pairs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Annihilation-gamma-based diagnostic techniques for magnetically confined electron–positron pair plasma

Efforts are underway to magnetically confine electron–positron pair plasmas to study their unique behaviour, which is characterized by significant changes in plasma time and length scales, supported waves and unstable modes. However, use of conventional plasma diagnostics presents challenges with these low-density and annihilating matter–antimatter plasmas. To address this problem, we propose to develop techniques based on the distinct emission provided by annihilation. This emission exhibits two spatial correlations: the distance attenuation of isotropic sources and the back-to-back propagation of momentum-preserving 2 $\gamma$ annihilation. We present the results of our analysis of the $\gamma$ emission rate and the spatial profile of the annihilation in a magnetized pair plasma from direct pair collisions, from the formation and decay of positronium as well as from transport processes. In order to demonstrate the effectiveness of annihilation-based techniques, we tested them on annular $\gamma$ emission profiles produced by a $\beta ^+$ radioisotope on a rotating turntable. Direct and positronium-mediated annihilation result in overlapping volumetric $\gamma$ sources, and the 2 $\gamma$ emission from these volumetric sources can be tomographically reconstructed from coincident counts in multiple detectors. Transport processes result in localized annihilation where field lines intersect walls, limiters or internal magnets. These localized sources can be identified by the fractional $\gamma$ counts on spatially distributed detectors.

Physics↗

Three‐Dimensional Permeability Inversion Using Convolutional Neural Networks and Positron Emission Tomography

Abstract Quantification of heterogeneous multiscale permeability in geologic porous media is key for understanding and predicting flow and transport processes in the subsurface. Recent utilization of in situ imaging, specifically positron emission tomography (PET), enables the measurement of three‐dimensional (3‐D) time‐lapse radiotracer solute transport in geologic media. However, accurate and computationally efficient characterization of the permeability distribution that controls the solute transport process remains challenging. Leveraging the relationship between local permeability variation and solute advection behavior, an encoder‐decoder based convolutional neural network (CNN) is implemented as a permeability inversion scheme using a single PET scan of a radiotracer pulse injection experiment as input. The CNN can accurately capture the 3‐D spatial correlation between the permeability and the radiotracer solute arrival time difference maps in geologic cores. We first test the inversion accuracy using synthetic test datasets and then test the accuracy on a suite of experimental PET imaging datasets acquired on four different geologic cores. The network‐predicted permeability maps from the geologic cores are used to parameterize forward numerical models that are directly compared with the experimental PET imaging data. The results indicate that a single trained network can generate robust 3‐D permeability inversion maps in seconds. Numerical models parameterized with these permeability maps closely capture the experimentally observed solute arrival time behavior. This work provides an unprecedented approach for efficiently characterizing multiscale permeability heterogeneity in complex geologic samples.

54 ENVIRONMENTAL SCIENCES↗

Defect accommodation in off-stoichiometric (SrTiO 3 ) n SrO Ruddlesden–Popper superlattices studied with positron annihilation spectroscopy

he low dielectric loss underlying the record performance of strained (SrTiO 3 ) n SrO Ruddlesden–Popper films as tunable microwave dielectrics was postulated to arise from (SrO) 2 faults accommodating local non-stoichiometric defects. Here, we explore the effect of non-stoichiometry on (SrTiO 3 ) n SrO using positron annihilation lifetime spectroscopy on a composition series of 300 nm thick n = 6 (Sr 1+δ TiO 3 ) n SrO thin films. These films show titanium-site vacancies across the stoichiometry series, with evidence that TiO x vacancy complexes dominate. Little change in defect populations is observed across the series, indicating the ability of Ruddlesden–Popper phases to accommodate ± 5% off-stoichiometry. This ability for defect accommodation is corroborated by scanning transmission electron microscopy with electron energy loss spectroscopy.

Physics↗

Non-neutral plasma manipulation techniques in development of a high-capacity positron trap

Preliminary experiments have been performed toward the development of a multi-cell Penning–Malmberg trap for the storage of large numbers of positrons (≥10 10 e + ). We introduce the master-cell test trap and the diagnostic tools for first experiments with electrons. The usage of a phosphor screen to measure the z-integrated plasma distribution and the number of confined particles is demonstrated, as well as the trap alignment to the magnetic field ( B = 3.1 T) using the m = 1 diocotron mode. The plasma parameters and expansion are described along with the autoresonant excitation of the diocotron mode using rotating dipole fields and frequency chirped sinusoidal drive signals. We analyze the reproducibility of the excitation and use these findings to settle on the path for the next generation multi-cell test device.

Singer, M.↗

In situ measurements of non-equilibrium positron state defects during He irradiation in Si

Radiation-induced property changes in materials originate from the energy transfer from an incoming particle to the existing lattice, displacing atoms. The displaced atoms can cause the formation of extended defects including dislocation loops, voids, or precipitates. The non-equilibrium defects created during damage events determine the extent of these larger defects and are a function of dose rate, material, and temperature. However, these defects are transient and can only be probed indirectly. Herein, we present direct experimental measurements and evidence of irradiated non-equilibrium vacancy formation, where in situ positron annihilation spectroscopy was used to prove the generation of non-equilibrium defects in silicon.

36 MATERIALS SCIENCE↗

Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20–300 GeV positrons

The Compact Muon Solenoid collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1.1 cm$^{2}$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Double deeply virtual Compton scattering with positron beams at SoLID

Double Deeply Virtual Compton Scattering (DDVCS) is the only experimental channel for the determination of the dependence of the Generalized Parton Distributions (GPDs) on both the average and the transferred momentum independently. The physics observables of the electron induced di-muon production reaction $\vv{e}^{\pm}p \to e^{\pm}p\mu^+\mu^-$ off unpolarized hydrogen are discussed. Their measurement with the high luminosity and large acceptance SoLID spectrometer at the Thomas Jefferson National Accelerator Facility, using polarized and unpolarized positron and electron beams at 11 GeV is investigated. This experimental configuration is shown to provide unprecedented access to the GPDs with the determination of the real and imaginary parts of the Compton Form Factor H in an unexplored phase space, and to enable an exploratory investigation of higher twist effects.

Zhao, S.↗

Deeply Virtual Compton Scattering Using a Positron Beam in Hall-C at Jefferson Lab

In this study we propose to use the High Momentum Spectrometer of Hall C combined with the Neutral Particle Spectrometer (NPS) to perform high precision measurements of the Deeply Virtual Compton Scattering (DVCS) cross section using a beam of positrons. The combination of measurements with oppositely charged incident beams is the only unambiguous way to disentangle the contribution of the DVCS 2 term in the photon electroproduction cross section from its interference with the Bethe-Heitler amplitude. This provides a stronger way to constrain the Generalized Parton Distributions of the nucleon. A wide range of kinematics accessible with an 11 GeV beam off an unpolarized proton target will be covered. The $\mathcal{Q}^2$-dependence of each contribution will be measured independently.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deep-inelastic scattering with positron beams

Here we discuss several advantages of using positron beams in addition to electron beams for the study of parton distribution functions (PDFs) of the nucleon in deep-inelastic scattering. Specific topics include the flavor separation of the unpolarized PDFs as well as the spin-dependent distributions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accurate determination of production data of the non-standard positron emitter 86 Y via the 86 Sr(p,n)-reaction

In view of several significant discrepancies in the excitation function of the 86 Sr(p,n) 86g+xm Y reaction which is the method of choice for the production of the non-standard positron emitter 86 Y for theranostic application, we carried out a careful measurement of the cross sections of this reaction from its threshold up to 16.2 MeV at Forschungszentrum Jülich (FZJ) and from 14.3 to 24.5 MeV at LBNL. Thin samples of 96.4% enriched 86 SrCO 3 were prepared by sedimentation and, after irradiation with protons in a stacked-form, the induced radioactivity was measured by high-resolution γ -ray spectrometry. The projectile flux was determined by using the monitor reactions nat Cu(p,xn) 62,63,65 Zn and nat Ti(p,x) 48 V, and the calculated proton energy for each sample was verified by considering the ratios of two reaction products of different thresholds. Additionally, the experimental cross section data obtained agreed well with the results of a nuclear model calculation based on the code TALYS. From the cross section data, the integral yield of 86 Y was calculated. Over the optimum production energy range E p = 14 → 7 MeV the yield of 86 Y amounts to 291 MBq/μA for 1 h irradiation time. This value is appreciably lower than the previous literature values calculated from measured and evaluated excitation functions. It is, however, more compatible with the experimental yields of 86 Y obtained in clinical scale production runs. The levels of the isotopic impurities 87m Y, 87g Y, and 88 Y were also estimated and found to be <2% in sum.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Selected advances in the accelerator design of the Future Circular Electron-Positron Collider (FCC-ee)

In autumn 2023, the FCC Feasibility Study underwent a crucial “mid-term review”. We describe some accelerator performance risks for the proposed future circular electron-positron collider, FCC-ee, identified for, and during, the mid-term review. For the collider rings, these are the collective effects when running on the Z resonance – especially resistive wall, beam-beam, and electron cloud –, the beam lifetime, dynamic aperture, alignment tolerances, and beam-based alignment. For the booster, the primary concern is the vacuum system, with regard to impedance and effects of the residual gas. For the injector, the layout and the linac repetition rate are primary considerations. We discuss the various issues and report the planned mitigations.

43 PARTICLE ACCELERATORS↗