Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Flow Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Improving Advanced Inverter Control Convergence in Distribution Power Flow

Simulation of modern distribution system powerflow increasingly requires capturing the impact of advanced PV inverter voltage regulation on powerflow. With Volt/var control, the inverter adjusts its reactive power flow as a function of the point of common coupling (PCC) voltage. Similarly, Volt/watt control curtails active power production as a function of PCC voltage. However, with larger systems and higher penetrations of PV, this active/reactive power flow itself can cause significant changes to the PCC voltage potentially introducing oscillations that slow the convergence of system simulations. Improper treatment of these advanced inverter functions could potentially lead to incorrect results. This paper explores a simple approach to speed such convergence by blending in the previous iteration's reactive power estimate to dampen these oscillations. Results with a single large (5MW) PV system and with multiple 500kW advanced inverters show dramatic improvements using this approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Chance Constrained Optimal Power Flow: Risk-Aware Network Control under Uncertainty

When uncontrollable resources fluctuate, Optimum Power Flow (OPF), routinely used by the electric power industry to re-dispatch hourly controllable generation (coal, gas and hydro plants) over control areas of transmission networks, can result in grid instability, and, potentially, cascading outages. This risk arises be cause OPF dispatch is computed without awareness of major uncertainty, in particular fluctuations in renewable output. As a result, grid operation under the OPF with renewable variability can lead to frequent conditions where power line flow ratings are significantly exceeded. Such a condition, which is borne by simulations of real grids, would likely resulting in automatic line tripping to protect lines from thermal stress, a risky and undesirable outcome which compromises stability. Smart grid goals include a commitment to large penetration of highly fluctuating renewables, thus calling to reconsider current practices, in particular the use of standard OPF. Our Chance Constrained (CC) OPF corrects the problem and mitigates dangerous renewable fluctuations with minimal changes in the current operational procedure. Assuming availability of a reliable wind forecast parameterizing the distribution function of the uncertain generation, our CC-OPF satisfies all the constraints with high probability while simultaneously minimizing the cost of economic re-dispatch. CC-OPF allows efficient implementation, e.g. solving a typical instance over the 2746-bus Polish network in 20s on a standard laptop.

Energy Planning, Policy, & Economy(29)↗

A Privacy-Preserving Distributed Control of Optimal Power Flow

Here, we consider a distributed optimal power flow formulated as an optimization problem that maximizes a nondifferentiable concave function. Solving such a problem by the existing distributed algorithms can lead to data privacy issues because the solution information exchanged within the algorithms can be utilized by an adversary to infer the data. To preserve data privacy, in this paper we propose a differentially private projected subgradient (DP-PS) algorithm that includes a solution encryption step. We show that a sequence generated by DP-PS converges in expectation, in probability, and with probability 1. Moreover, we show that the rate of convergence in expectation is affected by a target privacy level of DP-PS chosen by the user. We conduct numerical experiments that demonstrate the convergence and data privacy preservation of DP-PS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sacramento Municipal Utility District PV and Smart Grid Pilot at Anatolia

Under DE-FOA-0000085 High Penetration Solar Deployment, the U. S. Department of Energy funded agreements with SMUD and Navigant Consulting, SunPower, GridPoint, the National Renewable Energy Laboratory, and the California Energy Commission for this pilot demonstration project. Funding was $5,962,409.00. Cost share of $500,000 was also provided by the California Energy Commission. The project has strategic implications for SMUD, other utilities and the PV and energy-storage industries in business and resource planning, technology deployment and asset management. These implications include: -At this point, no dominant business models have emerged and the industry is open for new ideas. -Demonstrated two business models for using distributed PV and energy storage, and brainstormed several dozen more, each with different pros and cons for SMUD, its customers and the industry. -Energy storage can be used to manage high penetrations of PV and mitigate potential issues such as reverse power flow, voltage control violations, power quality issues, increased wear and tear on utility equipment, and system wide power supply issues. - Smart meters are another tool utilities can use to manage high penetrations of PV. The necessary equipment and protocols exist, and the next step is to determine how to integrate the functionality with utility programs and what level of utility control is required. - Time-of-use rates for the residential customers who hosted energy storage systems did not cause a significant change in energy usage patterns. However, the rates we used were not optimized for PV and energy storage. Opportunities exist for utilities to develop new structures.

14 SOLAR ENERGY↗

Multi-mode evaluation of power-maximizing cross-flow turbine controllers

A general method for predicting and evaluating the performance of three candidate cross-flow turbine power-maximizing controllers is presented in this paper using low-order dynamic simulation, scaled laboratory experiments, and full-scale field testing. For each testing mode and candidate controller, performance metrics quantifying energy capture (ability of a controller to maximize power), variation in torque and rotation rate (related to drive train fatigue), and variation in thrust loads (related to structural fatigue) are quantified for two purposes. First, for metrics that could be evaluated across all testing modes, we considered the accuracy with which simulation or laboratory experiments could predict performance at full scale. Second, we explored the utility of these metrics to contrast candidate controller performance. For these turbines and set of candidate controllers, energy capture was found to only differentiate controller performance in simulation, while the other explored metrics were able to predict performance of the full-scale turbine in the field with various degrees of success. Finally, effects of scale between laboratory and full-scale testing are considered, along with recommendations for future improvements to dynamic simulations and controller evaluation.

13 HYDRO ENERGY↗

Power System Decomposition for Practical Implementation of Bulk-Grid Voltage Control Methods

Power system algorithms such as AC optimal power flow and coordinated volt/var control of the bulk power system are computationally intensive and become difficult to solve in operational time frames. The computational time required to run these algorithms increases exponentially as the size of the power system increases. The solution time for multiple subsystems is less than that for solving the entire system simultaneously, and the local nature of the voltage problem lends itself to such decomposition. This paper describes an algorithm that can be used to perform power system decomposition from the point of view of the voltage control problem. Our approach takes advantage of the dominant localized effect of voltage control and is based on clustering buses according to the electrical distances between them. One of the contributions of the paper is to use multidimensional scaling to compute n-dimensional Euclidean coordinates for each bus based on electrical distance to perform algorithms like K-means clustering. A simple coordinated reactive power control of photovoltaic inverters for voltage regulation is used to demonstrate the effectiveness of the proposed decomposition algorithm and its components. The proposed decomposition method is demonstrated on the IEEE 118-bus system.

multidimensional scaling↗

Design Principles for Resonant Wave Energy Converters: Benchmarking Power Capture and Flow

Control co-design (CCD) in Wave Energy Converters (WECs) integrates the controller, power take-off (PTO), and buoy models during system design to optimize power output. Using the bi-conjugate impedance matching principle, this study models the PTO as a two-port network, revealing impedance matching conditions at the input and output ports as a function of the buoy, PTO, and controller. Here, this study examines the pairing of a flywheel-type pitch resonator PTO within a given buoy constrained by limited space and ballast capacity. The results show that physical constraints imposed by the buoy affect PTO performance. While controller tuning achieves optimal output impedance matching and flywheel inertia is maximized within the buoy's limitations, the PTO's input impedance remains smaller than the complex conjugate of the buoy's intrinsic impedance. This mismatch limits the PTO's ability to generate sufficient reaction torque, particularly outside the resonance frequency, resulting in narrow-band power transfer. The findings emphasize the need for PTO design modifications to improve input power transfer. Pendulum-based PTO mechanisms are proposed as alternatives to couple with multiple buoy motion modes and improve wave-to-wire efficiency while respecting system constraints.

Control Co-Design↗

Non-linear Model Predictive Control of Wave Energy Converters with Realistic Power Take-off Configurations and Loss Model

Model Predictive Control (MPC) has been recognized as a well-developed control strategy for optimizing the performance of wave energy converters (WECs). The standard problem involves maximizing the absorbed power from oncoming waves while respecting motion constraints of the device and force constraints of the power take-off (PTO). The generated electrical power is then calculated by assuming an ideal PTO with no power conversion losses or limitations to power flow. In this article, we remove the assumption of an ideal PTO and present four different control options that reflect unique combinations of PTO control and power flow constraints. We also recast the MPC problem to maximize the generated power instead of the absorbed power by accounting for the losses in the power train. Using a WEC with a hydraulic PTO, we develop a loss model suitable for controls optimization. Lastly, we illustrate the process of setting up the non-linear MPC problem and compare the performance of competing control strategies using a common benchmark based on annual energy captured at a reference site.

16 TIDAL AND WAVE POWER↗

Automatic-Control System for Safer Brazing

Automatic-control system for radio-frequency (RF) induction brazing of metal tubing reduces probability of operator errors, increases safety, and ensures high-quality brazed joints. Unit combines functions of gas control and electric-power control. Minimizes unnecessary flow of argon gas into work area and prevents electrical shocks from RF terminals. Controller will not allow power to flow from RF generator to brazing head unless work has been firmly attached to head and has actuated micro-switch. Potential shock hazard eliminated. Flow of argon for purging and cooling must be turned on and adjusted before brazing power applied. Provision ensures power not applied prematurely, causing damaged work or poor-quality joints. Controller automatically turns off argon flow at conclusion of brazing so potentially suffocating gas does not accumulate in confined areas.

Stein, J. A.↗

Visual Tool for Assessing Stability of DER Configurations on Three-Phase Radial Networks

Here, we present a method and tool for evaluating the placement of Distributed Energy Resources (DER) on distribution circuits in order to control voltages and power flows. Our previous work described Phasor-Based Control (PBC), a novel control framework where DERs inject real and reactive power to track voltage magnitude and phase angle targets. Here, we employ linearized power flow equations and integral controllers to develop a linear state space model for PBC acting on a three-phase unbalanced network. We use this model to evaluate whether a given inverter-based DER configuration admits a stable set of controller gains, which cannot be done by analyzing controllability nor by using the Lyapunov equation. Instead, we sample over a parameter space to identify a stable set of controller gains. Our stability analysis requires only a line impedance model and does not entail simulating the system or solving an optimization problem. We incorporate this assessment into a publicly available visualization tool and demonstrate three processes for evaluating many control configurations on the IEEE 123-node test feeder (123NF).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Studies on the Effects of High Renewable Penetrations on Driving Point Impedance and Voltage Regulator Performance: National Renewable Energy Laboratory/Sacramento Municipal Utility District Load Tap Changer Driving Point Impedance Project

Voltage regulators perform as desired when regulating from the source to the load and when regulating from a strong source (utility) to a weak source (distributed generation). (See the glossary for definitions of a strong source and weak source.) Even when the control is provisioned for reverse operation, it has been observed that tap-changing voltage regulators do not perform as desired in reverse when attempting regulation from the weak source to the strong source. The region of performance that is not as well understood is the regulation between sources that are approaching equal strength. As part of this study, we explored all three scenarios: regulator control from a strong source to a weak source (classic case), control from a weak source to a strong source (during reverse power flow), and control between equivalent sources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Minimization of the Power Generation Cost in Prosumer-Based Distribution Networks: Preprint

Traditionally, electrical power was generated in big power plants. The cost of producing energy was related to the cost of fuel, e.g., carbon or gas, and by the cost of maintaining the power plants. With the advent of distributed energy resources, power can be produced directly at the edge of the electrical network by a new type of agents: the prosumers. Prosumers are entities that both consume and generate power, e.g., by means of photovoltaic panels. The cost of the power produced by prosumers is no longer related to fuel consumption since energy coming from distributed generators is essentially free. Rather, the cost is related to the remuneration that is due to the prosumers for the services they provide. The proposed control strategy minimizes the active power generation cost in the aforementioned scenario. The control scheme requires that the prosumers measure their voltage and then adjust the amount of injected power, according to a continuous time feedback control law that is indeed a projected gradient descent strategy. Simulations are provided in order to illustrate the algorithm behavior.

distributed control↗

Communications and control for electric power systems: Power flow classification for static security assessment

This report investigates the classification of power system states using an artificial neural network model, Kohonen's self-organizing feature map. The ultimate goal of this classification is to assess power system static security in real-time. Kohonen's self-organizing feature map is an unsupervised neural network which maps N-dimensional input vectors to an array of M neurons. After learning, the synaptic weight vectors exhibit a topological organization which represents the relationship between the vectors of the training set. This learning is unsupervised, which means that the number and size of the classes are not specified beforehand. In the application developed in this report, the input vectors used as the training set are generated by off-line load-flow simulations. The learning algorithm and the results of the organization are discussed.

Niebur, D.↗

Hold-up power supply for flash memory

A hold-up power supply for flash memory systems is provided. The hold-up power supply provides the flash memory with the power needed to temporarily operate when a power loss exists. This allows the flash memory system to complete any erasures and writes, and thus allows it to shut down gracefully. The hold-up power supply detects when a power loss on a power supply bus is occurring and supplies the power needed for the flash memory system to temporally operate. The hold-up power supply stores power in at least one capacitor. During normal operation, power from a high voltage supply bus is used to charge the storage capacitors. When a power supply loss is detected, the power supply bus is disconnected from the flash memory system. A hold-up controller controls the power flow from the storage capacitors to the flash memory system. The hold-up controller uses feedback to assure that the proper voltage is provided from the storage capacitors to the flash memory system. This power supplied by the storage capacitors allows the flash memory system to complete any erasures and writes, and thus allows the flash memory system to shut down gracefully.

Ott, William E.↗