Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Telemetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Acoustic Telemetry Evaluation of Juvenile Salmonid Passage and Survival at John Day Dam, 2010

This report presents survival, behavioral, and fish passage results for yearling and subyearling Chinook salmon smolts and juvenile steelhead tagged with JSATS acoustic micro-transmitters as part of a survival study conducted at John Day Dam during 2010. This study was designed to evaluate the passage and survival of yearling and subyearling Chinook salmon and juvenile steelhead to assist managers in identifying dam operations for compliance testing as stipulated by the 2008 Federal Columbia River Power System Biological Opinion and the 2008 Columbia Basin Fish Accords. Survival estimates were based on a single-release survival estimate model.

Weiland, Mark A.↗

EVSE DERMS Controls [SWR-26-010]

An MQTT (Message Queuing Telemetry Transport) and OCPP (Open Charge Point Protocol) based remote smart charging controller framework for AC Electric Vehicle Supply Equipments (EVSEs). The code in this repo allows for the National Laboratory of the Rockies (NLR) controls to interface with the real Distributed Energy Resource Management System (DERMS) and EVSEs in NLR's ESIF Optimization and Control Laboratory (OCL). Different charge management algorithms can be tested to determine which power allocation method is most effective with the overall goal of demonstrating clear and well documented test results as well as providing functional control algorithms which could be utilized to provide effective smart charge management (SCM) at EV charging stations. Different power allocation methods are programmed in lab_demo_controller.py and include allocation based on first come first served, equal sharing, state of charge (SOC), priority factors, and behind the meter control methods.

Panossian, Nadia [National Laboratory of the Rocki↗

Extraction of Vibration Data with Imaging

To date, the primary sensing technology used to measure the vibration response has been accelerometers and strain gages mounted directly to the structure and using either wired or, more recently, wireless telemetry. Cost issues with these sensors and the associated data acquisition systems typically limit the numbers that are deployed on in situ structures. Although there are a few structures with larger sensing counts that in some cases exceed over 1000 sensors, more typical numbers range from ten to one hundred sensors resulting in low spatial resolution when they are applied to physically large systems. When one considers that nuclear power plant structures usually have complex geometries, material properties, connectivity and boundary conditions, it is clear these current approaches to vibration measurements can only provide limited information about a system’s dynamics response characteristics. As an alternative, many non-contact measurement technologies have emerged, including point wise measurement methods such as Global Positioning System (GPS), microwave interferometry, and laser Doppler vibrometry (LDV), as well as simultaneous full-field measurement methods such as electronic speckle pattern interferometry, holography interferometry, and muon tomography, some of which can provide high spatial resolution measurements. Among these methods, digital video imaging techniques have emerged as a feasible solution for full-field vibration measurements that provide significantly more detailed dynamic response information because every pixel becomes a measurement point. Furthermore, recent advances in image processing and computer vision algorithms have been successfully used to process video data for experimental and operational modal analysis. Such full-field measurements have the potential to significantly improve many current structural assessment procedures including system identification (modal parameter estimation), structural health monitoring, load reconstruction, model validation, and model updating. Furthermore, more recent full-field imaging techniques can be accomplished with relatively low-cost, commercially-available off-the-shelf cameras. However, these measurement procedures have other limitations that must be considered such as the ability to only measure visibly accessible points on a structure and a more limited dynamic range and bandwidth than can be achieved with accelerometers or strain gages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stochastic agent-based model for predicting turbine-scale raptor movements during updraft-subsidized directional flights

Rapid expansion of wind energy development across the world has highlighted the need to better understand turbine-caused avian mortality. The risk to golden eagles (Aquila chrysaetos) is of particular concern due to their small population size and conservation status. Golden eagles subsidize their flight in part by soaring in orographic updrafts, which can place them in conflict with wind turbines utilizing the same low-altitude wind resource. Understanding the behavior of soaring raptors in varying atmospheric conditions can therefore be relevant to predicting and mitigating their risk of collision. We present a predictive movement model that simulates individual paths of golden eagles during directional flight (such as migration) that is subsidized by orographic updraft. We modeled eagles in a 50 km by 50 km study area in Wyoming containing three wind power plants with documented golden eagle collisions with turbines. The movement model is applicable to any region where ground elevation is known at turbine scale (50 m) and wind conditions are known at facility scale (3 km). For a given set of atmospheric conditions, the model simulates movements of thousands of orographic soaring eagles to produce a density map quantifying the relative probability of eagle presence. We validated the simulated tracks with GPS telemetry data showing four directional tracks made by golden eagles transiting through the area in 2019 and 2020. For each eagle track, validation was performed using the ratio of the model-simulated eagle presence likelihood with uniform eagle presence and the presence computed using directed random-walk movements. We found that the predictive performance of the model was significantly better (likelihood ratio 1) for low-altitude movements than high-altitude movements that can involve thermal-soaring. We employed the model to produce seasonal presence maps for migrating golden eagles. We found significant turbine-level variations in eagle presence between northerly and southerly migration routes through the study area. Overall, the proposed model offers a generalizable, probabilistic, and predictive tool to assist wind energy developers, ecologists, wildlife managers, and industry consultants in estimating the potential for conflict between soaring birds and wind turbines, thereby reducing the need for site-specific data on golden eagle movements.

17 WIND ENERGY↗

220EV Box Truck Telemetry Dataset

This dataset contains telemetry data from the 220EV box truck as provided by the manufacturer, Dana. Data are recorded in a time series interval of 1 second. Recorded data contain odometer reading (kilometers), axle speed, state of charge of the battery, and cabin heater setting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

220EV Box Truck Telemetry Dataset

This dataset contains telemetry data from the 220EV box truck as provided by the manufacturer, Dana. Data are recorded in a time series interval of 1 second. Recorded data contain odometer reading (kilometers), axle speed, state of charge of the battery, and cabin heater setting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

220EV Box Truck Telemetry Dataset

This dataset contains telemetry data from the 220EV box truck as provided by the manufacturer, Dana. Data are recorded in a time series interval of 1 second. Recorded data contain odometer reading (kilometers), axle speed, state of charge of the battery, and cabin heater setting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

220EV Box Truck Telemetry Dataset

This dataset contains telemetry data from the 220EV box truck as provided by the manufacturer, Dana. Data are recorded in a time series interval of 1 second. Recorded data contain odometer reading (kilometers), axle speed, state of charge of the battery, and cabin heater setting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

220EV Box Truck Telemetry Dataset

This dataset contains telemetry data from the 220EV box truck as provided by the manufacturer, Dana. Data are recorded in a time series interval of 1 second. Recorded data contain odometer reading (kilometers), axle speed, state of charge of the battery, and cabin heater setting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

220EV Box Truck Telemetry Dataset

This dataset contains telemetry data from the 220EV box truck as provided by the manufacturer, Dana. Data are recorded in a time series interval of 1 second. Recorded data contain odometer reading (kilometers), axle speed, state of charge of the battery, and cabin heater setting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

220EV Box Truck Telemetry Dataset

This dataset contains telemetry data from the 220EV box truck as provided by the manufacturer, Dana. Data are recorded in a time series interval of 1 second. Recorded data contain odometer reading (kilometers), axle speed, state of charge of the battery, and cabin heater setting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

220EV Box Truck Telemetry Dataset

This dataset contains telemetry data from the 220EV box truck as provided by the manufacturer, Dana. Data are recorded in a time series interval of 1 second. Recorded data contain odometer reading (kilometers), axle speed, state of charge of the battery, and cabin heater setting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

220EV Box Truck Telemetry Dataset

This dataset contains telemetry data from the 220EV box truck as provided by the manufacturer, Dana. Data are recorded in a time series interval of 1 second. Recorded data contain odometer reading (kilometers), axle speed, state of charge of the battery, and cabin heater setting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

220EV Box Truck Telemetry Dataset

This dataset contains telemetry data from the 220EV box truck as provided by the manufacturer, Dana. Data are recorded in a time series interval of 1 second. Recorded data contain odometer reading (kilometers), axle speed, state of charge of the battery, and cabin heater setting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

220EV Box Truck Telemetry Dataset

This dataset contains telemetry data from the 220EV box truck as provided by the manufacturer, Dana. Data are recorded in a time series interval of 1 second. Recorded data contain odometer reading (kilometers), axle speed, state of charge of the battery, and cabin heater setting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Line Rating Oncor Electric Delivery Smart Grid Program

Electric transmission lines are the lifeline of the electric utility industry, delivering its product from source to consumer. This critical infrastructure is often constrained such that there is inadequate capacity on existing transmission lines to efficiently deliver the power to meet demand in certain areas or to transport energy from high-generation areas to high-consumption regions. When this happens, the cost of the energy rises; more costly sources of power are used to meet the demand or the system operates less reliably. These economic impacts are known as congestion, and they can amount to substantial dollars for any time frame of reference: hour, day or year. There are several solutions to the transmission constraint problem, including: construction of new generation, construction of new transmission facilities, rebuilding and reconductoring of existing transmission assets, and Dynamic Line Rating (DLR). All of these options except DLR are capital intensive, have long lead times and often experience strong public and regulatory opposition. The Smart Grid Demonstration Program (SGDP) project co-funded by the Department of Energy (DOE) and Oncor Electric Delivery Company developed and deployed the most extensive and advanced DLR installation to demonstrate that DLR technology is capable of resolving many transmission capacity constraint problems with a system that is reliable, safe and very cost competitive. The SGDP DLR deployment is the first application of DLR technology to feed transmission line real-time dynamic ratings directly into the system operation’s State Estimator and load dispatch program, which optimizes the matching of generation with load demand on a security, reliability and economic basis. The integrated Dynamic Line Rating (iDLR)1 collects transmission line parameters at remote locations on the lines, calculates the real-time line rating based on the equivalent conductor temperature, ambient temperature and influence of wind and solar radiation on the stringing section, transmits the data to the Transmission Energy Management System, validates its integrity and passes it on to Oncor and ERCOT (Electric Reliability Council of Texas) respective system operations. The iDLR system is automatic and transparent to ERCOT System Operations, i.e., it operates in parallel with all other system status telemetry collected through Supervisory Control and Data Acquisition (SCADA) employed across the company.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using the sound of nuclear energy

The generation of sound by heat has been documented as an “acoustical curiosity” since a Buddhist monk reported the loud tone generated by a ceremonial rice-cooker in his diary, in 1568. Over the last four decades, significant progress has been made in understanding “thermoacoustic processes,” enabling the design of thermoacoustic engines and refrigerators. Motivated by the Fukushima nuclear reactor disaster, we have developed and tested a thermoacoustic engine that exploits the energy-rich conditions in the core of a nuclear reactor to provide core condition information to the operators without a need for external electrical power. The heat engine is self-powered and can wirelessly transmit the temperature and reactor power level by generation of a pure tone which can be detected outside the reactor. We report here the first use of a fission-powered thermoacoustic engine capable of serving as a performance and safety sensor in the core of a research reactor and present data from the hydrophones in the coolant (far from the core) and an accelerometer attached to a structure outside the reactor. These measurements confirmed that the frequency of the sound produced indicates the reactor’s coolant temperature and that the amplitude (above an onset threshold) is related to the reactor’s operating power level. Furthermore, these signals can be detected even in the presence of substantial background noise generated by the reactor’s fluid pumps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technologies for Prolonging Cardiac Implantable Electronic Device Longevity

Prolonged longevity of cardiac implantable electronic devices (CIEDs) is needed not only as a passive response to match the prolonging life expectancy of patient recipients, but will also actively prolong their life expectancy by avoiding/deferring the risks (and costs) associated with device replacement. CIEDs are still exclusively powered by nonrechargeable primary batteries, and energy exhaustion is the dominant and an inevitable cause of device replacement. The longevity of a CIED is thus determined by the attrition rate of its finite energy reserve. The energy available from a battery depends on its capacity (total amount of electric charge), chemistry (anode, cathode, and electrolyte), and internal architecture (stacked plate, folded plate, and spiral wound). The energy uses of a CIED vary and include a background current for running electronic circuitry, periodic radiofrequency telemetry, high‐voltage capacitor reformation, constant ventricular pacing, and sporadic shocks for the cardiac resynchronization therapy defibrillators. The energy use by a CIED is primarily determined by the patient recipient's clinical needs, but the energy stored in the device battery is entirely under the manufacturer's control. A larger battery capacity generally results in a longer‐lasting device, but improved battery chemistry and architecture may allow more space‐efficient designs. Armed with the necessary technical knowledge, healthcare professionals and purchasers will be empowered to make judicious selection on device models and maximize the utilization of all their energy‐saving features, to prolong device longevity for the benefits of their patients and healthcare systems.

LAU, ERNEST W.↗