Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Conceptual Design Report for the I2 Instrumentation Experiment in ATRC

The US Department of Energy In-Pile Instrumentation (I2) program is tasked with developing advanced sensors for in-pile service as well as supporting the engineering required to implement existing nuclear sensor technologies in US high-power test reactors. The ATRC instrumentation test has been conceived to address both of these missions, specifically with respect to neutron flux measurements. Space has been allocated in the test for Self-Powered Neutron Detectors (SPNDs), fission chambers, and Micro-Pocket Fission Detectors (MPFDs). The real-time flux readings obtained from these instruments will be compared with time integrated data obtained from passive neutron dosimetry (i.e., “flux” wires). This work will be complementary to data obtained from the TREAT MIMIC-N experiment. This experiment is expected to support instrumentation efforts related to the proposed Medium-I loop and to instrumenting loop experiments conducted in the ATR center flux trap. While the MIMIC-N experiment was conducted in a dry environment, the ATRC I-19 experiment will be conducted in an aqueous environment, similar to the center flux trap loop experiments but will take place at ambient temperature and pressure, and at a much lower neutron flux. One of the challenges of the ATRC I-19 experiment will be low amplitude signals produced by the sensors in the low neutron fluxes of ATRC. However, related work conducted several years ago in ATRC was able to reliably detect signals using a similar instrument set.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of the KRUSTY Nuclear System Test

The Kilowatt Reactor Using Stirling TechnologY (KRUSTY) was a prototypic nuclear-powered test of a 5-kW(thermal) Kilopower space reactor. This paper presents results from the KRUSTY nuclear system test, which operated the power system at various temperatures and power levels for 28 consecutive hours. The testing showed that the system operated as expected and that the reactor is highly tolerant of possible failure conditions and transients. The key feature demonstrated was the ability of the reactor to load-follow the demand of the power conversion system. The thermal power of the test ranged from 1.5 to 5.0 kW(thermal), with a fuel temperature up to 880°C. Each 80-W(electric)–rated Stirling converter produced ~90 W(electric) at a component efficiency of ~35% and an overall system efficiency of ~25%.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Heterogeneous Integration Technologies for High-temperature, High-density, Low-profile Power Modules of Wide Bandgap Devices in Electric Drive Applications (Final Technical Report)

The goal of this project is to develop packaging technologies for making high-temperature, high-density, and low-profile wide-bandgap (WBG) power electronics modules for electric drives. These modules are aimed at enabling the DOE’s University Consortium to reach its 2025 inverter targets of ≥ 100 kW/L and ≤ 2.7 $/kW. The specific objectives are to: design and fabricate SiC half-bridge power modules with double-sided cooling and parasitic inductances < 5 nH, heat flux density > 400 W/cm 2 , and working junction temperature of 200 o C; design, fabricate, and deliver a gate driver with double-sided cooled modules for the construction of a 100 kW/L inverter at Oak Ridge National Lab; and design and prototype intelligent gate drivers with integrated current sensor and a low-profile DC-DC power supply with air-core transformer for testing power modules at 200 o C junction temperature. We followed an iterative technical approach of design, simulation, fabrication, and testing of various versions of modules, current sensors, and power supply. The state-of-the-art silicon carbide devices rated at 1.2 kV and 149 A were packaged by sintered-silver bonding on an aluminum nitride direct-bond-copper substrate for high thermal conductivity, high working temperature, and high joint reliability. Porous silver posts were used to interconnect the device’s source pads to the other direct-bond-copper substrate for low mechanical stresses, ease of manufacturing, and double-sided cooling. A current sensor based on package parasitic inductance was developed to measure switching current. A dynamic feedback scheme was developed to compensate the effect of parasitic resistance and temperature variation. A constant-current class-E dc-dc converter with air-core transformer was developed. Air-core transformer was used due to the unavailability of magnetic core at high temperatures. Gate driver and power supply were integrated with the double-side cooled, high temperature SiC power modules for testing the modules at 200 o C junction temperature. Double-pulse and continuous testing of the integrated technologies validated the design and fabrication of the three component technologies. Throughout the project, we overcame the challenge for design verification caused by low prototyping yield, which then helped train the graduate students, the future workforce, to learn the engineering know-how for low-cost manufacturing of reliable products. Below is a summary of the major accomplishments of this project: development of a prototyping process for fabricating double-side cooled (1200 V, 149 A) SiC phase-leg modules capable of working to 200 o C Tj; simulation and experimental verification of the improvement of thermo-mechanical reliability of the double-side cooled SiC phase-leg module by using rigid encapsulant; design and experimental validation of a current sensor based on package parasitic inductance and a compensation solution for eliminating the effect of parasitic resistance; design and experimental validation of a low-profile power supply with six-output air-core transformer for gate driver; functional demonstration of a SiC phase-leg module integrated with its gate driver, current sensor, and an air-core power supply at 200 o C Tj in a double-pulse switching test setup and Buck converter continuous test setup; successful completion of six PhD and two MS students who are or will work at Apple Inc., Tesla Inc., Wolfspeed Inc., Microchip Inc., Monolithic Power Systems Inc., and LG Magna Inc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Current Cold Cathode Employing Diamond and Related Materials

The essence of this project was for diamond films to be deposited on cold cathodes to improve their emission properties. Films with varying morphology, composition, and size of the crystals were deposited and the emission properties of the cathodes that utilize such films were studied. The prototype cathodes fabricated by the methods developed during Phase I were tested and evaluated in an actual high-power RF device during Phase II. These high-power tests used the novel active RF pulse compression system and the X-band magnicon test facility at US Naval Research Laboratory. In earlier tests, plasma switches were employed, while tests under this project utilized electron-beam switching. The intense electron beams required in the switches were supplied from cold cathodes embodying diamond films with varying morphology, including uncoated molybdenum cathodes in the preliminary tests. Tests with uncoated molybdenum cathodes produced compressed X-band RF pulses with a peak power of 91 MW, and a maximum power gain of 16.5:1. Tests were also carried out with switches employing diamond coated cathodes. The pulse compressor was based on use of switches employing electron beam triggering to effect mode conversion. In experimental tests, the compressor produced 165 MW in a ~ 20 ns pulse at ~18× power gain and ~ 140 MW at ~ 16× power gain in a 16 ns pulse with a ~ 7 ns flat-top. In these tests, molybdenum blade cathodes with thin diamond coatings demonstrated good reproducible emission uniformity with a 100 kV, 100 ns high voltage pulse. The new compressor does not have the limitations of earlier types of active pulse compressors and can operate at significantly higher electric fields without breakdown.

36 MATERIALS SCIENCE↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Characterization and Comparison of Planar and Trench Silicon Carbide (SiC) Power MOSFETs

This paper presents a comprehensive evaluation and experimental comparison of silicon carbide power MOSFETs through double pulse test. First, a universal hardware platform is designed and developed to test power semiconductor devices with various device packages and measuring requirements. Using the developed platform, the static characteristics and switching performance of the two types of SiC MOSFETs (one planar and one trench type) are evaluated under different case temperatures from 25 oC to 175 oC. Based on the evaluation data, a comparison of both SiC MOSFETs is conducted in terms of their on-state resistance, switching loss, and temperature dependent behavior. It is found that the latest trench SiC MOSFETs present similar switching loss while much lower conduction loss compared to existing commercial planar SiC MOSFETs. Moreover, the trench devices show a nearly temperature independent switching loss, which is beneficial to suppress the potential thermal runaway issue under high temperature continuous operation.

double pulse test↗

Validation of the U.S. NRC coupled code system TRITON/TRACE/PARCS with the special power excursion reactor test III (SPERT III)

The Special Power Excursion Reactor Test III (SPERT III) was a series of reactivity insertion experiments conducted in the 1950's. This paper describes the validation of the U.S. NRC Coupled Code system TRITON/PARCS/TRACE to simulate reactivity insertion accidents (RIA) by using several of the SPERT III tests. The work here used the SPERT III E-core configuration tests in which the RIA was initiated by ejecting a control rod. The resulting super-prompt reactivity excursion and negative reactivity feedback produced the familiar bell shaped power increase and decrease. The energy deposition during such a power peak has important safety consequences and provides validation basis for core coupled multi-physics codes. The transients of five separate tests are used to benchmark the PARCS/TRACE coupled code. The models were thoroughly validated using the original experiment documentation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Completion of Nuclear Testing after Core Internals Changeout #6 in the Advanced Test Reactor

A series of physics tests were conducted in 2022 for the Advanced Test Reactor (ATR) after the sixth Core Internals Changeout (CIC) in 2021. These tests verify nuclear characteristics of the new reflector and shim mechanisms and are validation cases for core models. This work describes the results of these tests and compares the physics tests with those performed previously in ATR and updates previous work reporting on planning for nuclear testing and on preliminary results of several low-power tests. This work also identifies unique characteristics of ATR that result in the need for unique tests.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An Extended IEEE 118-Bus Test System With High Renewable Penetration

This article describes a new publicly available version of the IEEE 118-bus test system, named NREL-118. The database is based on the transmission representation (buses and lines) of the IEEE 118-bus test system, with a reconfigured generation representation using three regions of the US Western Interconnection from the latest Western Electricity Coordination Council (WECC) 2024 Common Case [1]. Time-synchronous hourly load, wind, and solar time series are provided for over one year (8784 hours). The public database presented and described in this manuscript will allow researchers to model a test power system using detailed transmission, generation, load, wind, and solar data. This database includes key additional features that add to the current IEEE 118-bus test model, such as: the inclusion of 10 generation technologies with different heat rate functions, minimum stable levels and ramping rates, GHG emissions rates, regulation and contingency reserves, and hourly time series data for one full year for load, wind and solar generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wave Energy Power Take-off Validation with a Hydraulicly Actuated Rotary Dynamometer and a Bi-Directional High-Power DC Supply

There are many organizations working towards the commercialization of wave energy converter technologies and are advancing their designs through the technology readiness levels (TRLs). A critical step before the field deployment of prototype wave energy converters is the validation of the subsystems and components that are contained in the wave energy converter through laboratory testing and performance characterization. In 2021, the National Renewable Energy Laboratory (NREL) developed and demonstrated a system for testing power takeoffs (PTO) with a low-speed, high-torque dynamometer and a grid-tied high-power DC power source and sink before field deployment. The hydraulic dynamometer allows for the simulation of PTO actuation from wave motion and is capable of a wide range of wave periods and heights which are represented as various speeds and torques from the dynamometer. The high-power bidirectional power supply allows for hardware in the loop and controller in the loop testing to be conducted on WEC power electronics. This presentation was made to describe the methods used by NREL research staff to test all components and sub-systems in the PTO of a novel wave energy converter before field deployment.

dynamometer↗

Wave Energy Power Take-Off Validation with a Hydraulicly Actuated Rotary Dynamometer and a Bidirectional High-Power DC Supply: Preprint

There are many organizations working towards the commercialization of wave energy converter technologies and are advancing their designs through the technology readiness levels (TRLs). A critical step before the field deployment of prototype wave energy converters is the validation of the subsystems and components that are contained in the wave energy converter through laboratory testing and performance characterization. In 2021, the National Renewable Energy Laboratory (NREL) developed and demonstrated a system for testing power takeoffs (PTO) with a low-speed, high-torque dynamometer and a grid-tied high-power DC power source and sink before field deployment. The hydraulic dynamometer allows for the simulation of PTO actuation from wave motion and is capable of a wide range of wave periods and heights which are represented as various speeds and torques from the dynamometer. The high-power bidirectional power supply allows for hardware in the loop and controller in the loop testing to be conducted on WEC power electronics. This presentation was made to describe the methods used by NREL research staff to test all components and sub-systems in the PTO of a novel wave energy converter before field deployment.

dynamometer↗