Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Tower”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Technoeconomic Analysis Round Robin of a Retrofit of the Ivanpah Concentrating Solar Plant with a Molten-Salt System with Thermal Energy Storage

While the fidelity of technoeconomic analysis (TEA) models for concentrating solar thermal systems has improved in recent years, there is a lack of consensus on the specific inputs used to forecast performance of a newly built tower system due to a lack of validations and post-mortems available to the public. This effort is a joint initiative between multiple international organizations to validate and compare their TEA models. The specific case study is a proposed retrofit of one unit of the Ivanpah Solar Energy Generating System to include molten-salt storage, replacing the steam generation system with a molten-salt receiver, salt-to-steam heat exchanger train, and new balance of plant while keeping the existing steam turbine, solar field, and interconnection in place, using plant data for calibration. This manuscript discusses several of the agreed-upon assumptions for this study as well as a preliminary analysis from prior work that motivates the study.

14 SOLAR ENERGY↗

Evaluation of external tubular configurations for a high-temperature chloride molten salt solar receiver operating above 700°C

Next-generation concentrating solar power (CSP) tower technologies target operating temperatures exceeding 700°C to increase the thermal-to-electric conversion efficiency. Molten chloride salts are one possible alternative to current commercial molten nitrate salts to enable the higher operating temperature. This paper analyzes the predicted optical, thermal-fluids, and structural performance of traditional external tubular solar receiver configurations applied with a chloride salt heat transfer fluid (HTF) and inlet/outlet temperatures of 500°C/735°C, and considers sensitivity analysis and optimization relative to receiver sizing, tube sizing, number of panels, flow circuit configurations, and solar flux concentration under constraints on internal velocity, pressure drop, wall thickness, and required creep-fatigue lifetime. The high temperature conditions increase the significance of inelastic deformation mechanisms such as creep relative to that expected in commercial 565°C nitrate salt designs. High-temperature creep and creep-fatigue damage in the metal alloy tubes are the key factors that limit allowable solar flux concentration and achievable receiver thermal efficiency at the near-800°C wall temperature conditions. For a traditional external cylindrical receiver configuration, the design parameters and conditions capable of satisfying all constraints produced, at best, a design point receiver efficiency of 78.2%, or 80.5% when excluding receiver intercept efficiency. Variation in the optimal receiver performance relative to uncertainty in the binding maximum velocity, minimum wall thickness, and minimum lifetime constraints is presented.

14 SOLAR ENERGY↗

Coupled dynamics analysis of wind energy systems

A qualitative description of all key elements of a complete wind energy system computer analysis code is presented. The analysis system addresses the coupled dynamics characteristics of wind energy systems, including the interactions of the rotor, tower, nacelle, power train, control system, and electrical network. The coupled dynamics are analyzed in both the frequency and time domain to provide the basic motions and loads data required for design, performance verification and operations analysis activities. Elements of the coupled analysis code were used to design and analyze candidate rotor articulation concepts. Fundamental results and conclusions derived from these studies are presented.

Hoffman, J. A.↗

Open Data Integration (ODIN): A Concurrent, Distributed Message-Based Architecture and Framework for Disaster Response

The Runtime for Airspace Concept Evaluation (RACE) is an open-source software architecture and framework to build configurable, highly concurrent and distributed message-based systems that offer scalable, low-latency performance on commodity hardware. RACE was used in commercial aviation applications to rapidly build systems that span several machines (including synchronized displays), interface existing hardware simulators and other live data feeds, and incorporate sophisticated visualization components such as NASA WorldWind. These RACE applications validated elements of the FAA’s System Wide Information Management (SWIM) Program, handling up to 1000 messages/sec from diverse sources (SFDPS, TFM-DATA, TAIS, ASDE-X, ITWS and local ADS) for 4,500 simultaneous flights tracked in the next-generation air transportation system’s digital backbone. We have since generalized RACE to support Open Data Integration (ODIN) applications outside aviation. Systems built with RACE/ODIN can be deployed in the field, on commodity hardware, and operate with limited or intermittent connectivity to the outside world. Our primary use case is a web-server with local/persistent data storage that runs within and only serves the stakeholder network (e.g. an incident command post). We are tailoring the RACE/ODIN system to support wildland fire management for the upcoming NASA Wildland Fire Safety Demonstration Series. RACE-ODIN is under consideration for application in the Scalable Traffic Management for Emergency Response Operations project, or STEReO, which aims to create a system that can be deployed during emergencies, to coordinate multiple elements of disaster response. Such data sources predominantly come from existing services on the internet (e.g. weather and satellite data, imported from so called "edge servers") but can also include dynamic (real-time) data from computer simulations and within the stakeholder network (such as aircraft and personnel tracking information). We will present the architecture and ODIN system demonstration incorporating local data from instrumented power-line towers, interpolated weather data and geospatial data from space-based platforms.

Joseph C Coughlan↗

Open Data Integration (ODIN): A Concurrent, Distributed Message-Based Architecture and Framework for Disaster Response

The Runtime for Airspace Concept Evaluation (RACE) is an open-source software architecture and framework to build configurable, highly concurrent and distributed message-based systems that offer scalable, low-latency performance on commodity hardware. RACE was used in commercial aviation applications to rapidly build systems that span several machines (including synchronized displays), interface existing hardware simulators and other live data feeds, and incorporate sophisticated visualization components such as NASA WorldWind. These RACE applications validated elements of the FAA’s System Wide Information Management (SWIM) Program, handling up to 1000 messages/sec from diverse sources (SFDPS, TFM-DATA, TAIS, ASDE-X, ITWS and local ADS) for 4,500 simultaneous flights tracked in the next-generation air transportation system’s digital backbone. We have since generalized RACE to support Open Data Integration (ODIN) applications outside aviation. Systems built with RACE/ODIN can be deployed in the field, on commodity hardware, and operate with limited or intermittent connectivity to the outside world. Our primary use case is a web-server with local/persistent data storage that runs within and only serves the stakeholder network (e.g. an incident command post). We are tailoring the RACE/ODIN system to support wildland fire management for the upcoming NASA Wildland Fire Safety Demonstration Series. RACE-ODIN is under consideration for application in the Scalable Traffic Management for Emergency Response Operations project, or STEReO, which aims to create a system that can be deployed during emergencies, to coordinate multiple elements of disaster response. Such data sources predominantly come from existing services on the internet (e.g. weather and satellite data, imported from so called "edge servers") but can also include dynamic (real-time) data from computer simulations and within the stakeholder network (such as aircraft and personnel tracking information). We will present the architecture and ODIN system demonstration incorporating local data from instrumented power-line towers, interpolated weather data and geospatial data from space-based platforms.

Guillaume P Brat↗

2021 Prototype Testing Awardee: Sonsight Wind

For small wind turbines - those under 10 kilowatts (kW) in generating capacity - the combined costs for turbines, towers, foundations, power electronics, installation, and maintenance can result in a high levelized cost of energy (LCOE). This makes it difficult for small wind turbines to gain a foothold in the distributed energy revolution currently being led by solar power. Sites with high average wind speeds generally allow lower LCOE, but the vast majority of Americans live and work within more moderate-wind-speed areas, so small turbines should be cost effective to buy and use within such areas. Sonsight Wind's 3.5-kW horizontal-axis wind turbine (HAWT) is being developed to address these challenges.

CIP↗

NLR HPC Facility Power Usage Effectiveness (PUE) Data

Timeseries of Energy Systems Integration Facility (ESIF) Data Center Power Usage Effectiveness (PUE) Data provided in Parquet and compressed CSV formats Power Metrics Timeseries Fields: ts: Timestamp cooling_kw: Cooling (kilowatts) - Captures the power used by fans and pipe trace heaters associated with outdoor cooling equipment. The dedicated tower filter pump power is also captured as cooling load. energy_reuse: Energy Reuse Effectiveness hvac_kw: Heating, ventilation, and air conditioning (kilowatts) - Captures fan walls, fan coils that support the data center electrical rooms, and the make-up air unit. it_power_kw: IT equipment (kilowatts) - Captures power used by the IT equipment on the data center floor. plug_and_light_kw: Lights and utility plugs (kilowatts) - Captures power associated with the data center and dedicated mechanical room. The crank-case heater for the emergency standby generator is also captured as light and plug load. pue: Power Usage Effectiveness pump_kw: Pumps (kilowatts) - Captures power from pumps that move water in the data center Energy Recover Water loop and the Tower Water loops, and also captures power used by the boost pumps that circulate water through the fan walls. Note: The tower filter pump runs constantly to filter water from the data center cooling tower system, so 2.67 kilowatts are attributed to this pump and that is not reflected in this data field. day: Day of month Outside Weather Station Timeseries Fields: ts: Timestamp outside_air_humidity: Outside air humidity - Relative humidity percent outside_air_temp: Outside air temperature - Degrees Fahrenheit day: Day of month More detail: High-Performance Computing Data Center Power Usage Effectiveness

97 MATHEMATICS AND COMPUTING↗

Review of stand-alone photovoltaic application projects sponsored by US DOE and US AID

Experience with dc photovoltaic systems (without backup power) and ranging in output from 23 to 3,500 peak watts, in a wide range of environmental conditions and with a wide range of insolation, is described. Cooperation of NASA with other government agencies resulted in the installation of an air pollution monitor in New Jersey, a seismic sensor in Hawaii, power for lookout towers in national forests in California, an electric power system for a Papago Indian village in Arizona, and a power system for a grain mill and water pump in Tangaye, Upper Volta. Significant operational results are discussed and system reliability is assessed for the 20 experimental systems installed since 1976. Additional systems to be installed overseas are highlighted, and economic factors are considered.

Bifano, W. J.↗

Advanced Electric Propulsion for Space Solar Power Satellites

The sun tower concept of collecting solar energy in space and beaming it down for commercial use will require very affordable in-space as well as earth-to-orbit transportation. Advanced electric propulsion using a 200 kW power and propulsion system added to the sun tower nodes can provide a factor of two reduction in the required number of launch vehicles when compared to in-space cryogenic chemical systems. In addition, the total time required to launch and deliver the complete sun tower system is of the same order of magnitude using high power electric propulsion or cryogenic chemical propulsion: around one year. Advanced electric propulsion can also be used to minimize the stationkeeping propulsion system mass for this unique space platform. 50 to 100 kW class Hall, ion, magnetoplasmadynamic, and pulsed inductive thrusters are compared. High power Hall thruster technology provides the best mix of launches saved and shortest ground to Geosynchronous Earth Orbital Environment (GEO) delivery time of all the systems, including chemical. More detailed studies comparing launch vehicle costs, transfer operations costs, and propulsion system costs and complexities must be made to down-select a technology. The concept of adding electric propulsion to the sun tower nodes was compared to a concept using re-useable electric propulsion tugs for Low Earth Orbital Environment (LEO) to GEO transfer. While the tug concept would reduce the total number of required propulsion systems, more launchers and notably longer LEO to GEO and complete sun tower ground to GEO times would be required. The tugs would also need more complex, longer life propulsion systems and the ability to dock with sun tower nodes.

Oleson, Steve↗

Tall Lunar Towers: Systems Analysis of a Lunar-Surface-Assembled Power, Communication, and Navigation Infrastructure

The National Aeronautics and Space Administration (NASA) intends to develop and maintain a human-lunar presence, requiring infrastructure on the Lunar South Pole. To keep pace with the continued growth in cislunar activity, there is national interest in developing a global lunar infrastructure network for power and Communication, Position, Navigation, and Timing (CPNT). Demonstrating autonomous construction capabilities is an infrastructure-enabling objective. This study explores several architecture trade studies to assess the feasibility of alternative lunar infrastructure concepts. 50 m towers, for instance, enable solar power generation up to 99% of a lunar year in addition to acting as wide-range communication and navigation surface relays. The infrastructure network considered in this study consisted of tower platforms, utilities hosted on the towers, and both crewed and robotic end users. High-level trades were analyzed, such as tower height, location, and distributed vs centralized power grids. Results indicated that even with minimal permanent surface assets (darkness survival power loads on the order of 5 kW or greater), at any of the five locations considered, taller towers resulted in lower infrastructure mass than shorter towers; up to 24% system mass savings were realized by reducing battery mass. Simultaneously, taller towers increased the range of communication coverage; a 50 m tower on the Connecting Ridge had 5 kg more structure and 76% more line-of-sight coverage to a two-meter-tall end user than a 10 m tower with the same location and user height. Leveraging a grid of tall towers for nominal power and communication would not only save up to 2,800 kg in battery mass but would be more maintainable and allow users to take advantage of generational upgrades.

lunar infrastructure↗

WEST-3 wind turbine simulator development. Volume 2: Verification

The details of a study to validate WEST-3, a new time wind turbine simulator developed by Paragib Pacific Inc., are presented in this report. For the validation, the MOD-0 wind turbine was simulated on WEST-3. The simulation results were compared with those obtained from previous MOD-0 simulations, and with test data measured during MOD-0 operations. The study was successful in achieving the major objective of proving that WEST-3 yields results which can be used to support a wind turbine development process. The blade bending moments, peak and cyclic, from the WEST-3 simulation correlated reasonably well with the available MOD-0 data. The simulation was also able to predict the resonance phenomena observed during MOD-0 operations. Also presented in the report is a description and solution of a serious numerical instability problem encountered during the study. The problem was caused by the coupling of the rotor and the power train models. The results of the study indicate that some parts of the existing WEST-3 simulation model may have to be refined for future work; specifically, the aerodynamics and procedure used to couple the rotor model with the tower and the power train models.

Sridhar, S.↗

Powering the Future

Stirling Technology Company (STC) developed the RG-350 convertor using components from separate Goddard Space Center and U.S. Army Natick SBIR contracts. Based on the RG-350, STC commercialized a product line of Stirling cycle generator sets, known as RemoteGen(TM), with power levels ranging from 10We to 3kWe. Under SBIR agreements with Glenn Research Center, the company refined and extended the capabilities of the RemoteGen convertors. They can provide power in remote locations by efficiently producing electricity from multiple-fuel sources, such as propane, alcohol, gasoline, diesel, coal, solar energy, or wood pellets. Utilizing any fuel source that can create heat, RemoteGen enables the choice of the most appropriate fuel source available. The engines operate without friction, wear, or maintenance. These abilities pave the way for self-powered appliances, such as refrigerators and furnaces. Numerous applications for RemoteGen include quiet, pollution-free generators for RVs and yachts, power for cell phone towers remote from the grid, and off-grid residential power variously using propane, ethanol, and solid biomass fuels. One utility and the National Renewable Energy Laboratory are evaluating a solar dish concentrator version with excellent potential for powering remote irrigation pumps.

Source record↗

Transformers for Lunar Extreme Environments: Ensuring Long-Term Operations in Regions of Darkness and Low Temperatures: II - Phase

This report shows how solar power could enable robotic operations in permanently shaded regions at lunar poles, to extract water ice and further produce liquid hydrogen and oxygen (LH2/LO2) propellant. The power needs are derived from an Architecture for Human Exploration of Mars based entirely on lunar propellant. The extraction of 10 metric tons of water per day (at 10% water in regolith) requires approx. 0.6 MW thermal power. Additional approx. 2 MW electric power are required to produce 7.5 metric tons of LH2/LO2 propellant per day, as needed by the architecture. To provide power to processing equipment inside Shackleton Crater, optimal locations are determined on the crater rim, from which several reflecting TransFormers (TFs) would redirect sunlight, achieving a combined period of illumination of approx. 99% of the year. A single 40-m diameter reflector could provide up to 1 MW solar power. Inflatable rigidizable tower support structures raise reflectors above ground for better solar exposure. There are trade-offs: e.g., two reflectors at ground level would provide the same combined total illumination as a single tower approx. 100-m tall. Such a TF based on a 100-m tower made with inflatable 2-m beams and 40-m diameter reflectors would be of similar dimensions as an MSL-class rover (approx. 1000 kg, 10 m(exp 3)). A TF-prospector rover combo could be designed and deployed in a Discovery-class mission searching for water. The TransFormers would be nodes of a Lunar Utilities Infrastructure that provides solar power year-round in the proximity of the pole, as well as local data transmission andintermittent direct to earth communications. This infrastructure would be instrumental infacilitating the development of a lunar economy.

fuel↗

Investigating the interactions between wakes and floating wind turbines using FAST.Farm

As floating offshore wind progresses to commercial maturity, wake and array effects across a farm of floating offshore wind turbines (FOWTs) will become increasingly important. While wakes of land-based and bottom-fixed offshore wind turbines have been extensively studied, only recently has this topic become relevant for floating turbines. This work presents an investigation of the mutual interaction between the motions of floating wind turbines and wakes using FAST.Farm. While FAST.Farm has been extensively validated across a wide range of conditions, it has never been validated for FOWT applications. Hence, in the first part of this work, we validate FAST.Farm by comparing simulations of a single FOWT against high-fidelity results from large-eddy simulations available in the literature. The validation is based on wake meandering, mean wake deflection, and velocity deficit at different downstream locations. This validation showed that the original axisymmetric (polar) wake model of FAST.Farm overpredicts the vertical wake deflection induced by shaft tilt and floater pitch, while the new curled wake model is capable of properly capturing the vertical wake deflection. In the second part, we use FAST.Farm to analyze a small three-unit array of FOWTs with a spacing of 7 diameters across a wide range of environmental conditions. The same National Renewable Energy Laboratory 5 MW reference wind turbine atop the OC4-DeepCwind semisubmersible is adopted for the three FOWTs and for the validation against high-fidelity simulations. To assess the effect of the floating substructure, we compare the power production, tower-base moments, and blade-root moments obtained for the floating turbines with the results obtained in a fixed-bottom configuration. The main differences introduced by the floating substructure are the motions induced by the waves, the change in the natural frequencies of the tower caused by differences in the boundary condition at its base, and the larger vertical deflection of the wake deficit due to the mean pitch of the platform. The impact of these differences, as well as other minor effects, are analyzed in detail.

16 TIDAL AND WAVE POWER↗

Mechanical Solutions Scan Report

Power lines, poles, and towers are the backbone of the United States (U.S.) electric-power grid. These transmission and distribution networks route electricity from generator to loads. The characteristics of these routes are rapidly changing -- trending towards decentralized renewable generation, electric heating, vehicle charging, and large data-center loads. Coupled with aging infrastructure and the increased frequency of extreme weather events, there is concern about the future reliability and transmission capacity of conductors and adjacent components. This scan report seeks to provide an overview of mechanical solutions to challenges caused by extreme weather events associated with components of transmission and distribution infrastructure, including conductor heat sag, ice accumulation, wind, and wildfire. Many options could increase transmission capacity or reliability, and these are at various stages of technological readiness. Some have only been lab tested, while some have been widely deployed in the U.S. or overseas for decades. The solution categories and providers featured in this report are intended to be comprehensive at the time of publication and to serve as a reference for decision-makers concerned about transmission and distribution reliability. There are two other categories of large, complex solutions, which are not covered in this report: replacing existing conductors with advanced conductors and implementing digital grid enhancing technologies. A separate scan report titled “Advanced Conductor Scan Report,” which discusses advanced carbon-core conductors, was published by the Idaho National Laboratory (INL) in 2023. Information on digital technologies, such as dynamic line ratings, power-flow controllers, and other power electronics and communications-based devices, can be found on the Grid- Enhancing Technologies landing page. Mechanical grid-enhancing technologies, or solutions covered in this report, often do not require full equipment replacement and do not rely on digital components. Mechanical technologies are overlooked because they may be older, simpler, or seemingly “more obvious” than digital or carbon-core technologies. However, it is wise to consider mechanical solutions in a thorough evaluation of grid enhancing technology solutions.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Building an Economical and Sustainable Lunar Infrastructure to Enable Lunar Industrialization

A new concept study was initiated to examine the architecture needed to gradually develop an economical, evolvable and sustainable lunar infrastructure using a public/private partnerships approach. This approach would establish partnership agreements between NASA and industry teams to develop a lunar infrastructure system that would be mutually beneficial. This approach would also require NASA and its industry partners to share costs in the development phase and then transfer operation of these infrastructure services back to its industry owners in the execution phase. These infrastructure services may include but are not limited to the following: lunar cargo transportation, power stations, communication towers and satellites, autonomous rover operations, landing pads and resource extraction operations. The public/private partnerships approach used in this study leveraged best practices from NASA's Commercial Orbital Transportation Services (COTS) program which introduced an innovative and economical approach for partnering with industry to develop commercial cargo services to the International Space Station. This program was planned together with the ISS Commercial Resupply Services (CRS) contracts which was responsible for initiating commercial cargo delivery services to the ISS for the first time. The public/private partnerships approach undertaken in the COTS program proved to be very successful in dramatically reducing development costs for these ISS cargo delivery services as well as substantially reducing operational costs. To continue on this successful path towards installing economical infrastructure services for LEO and beyond, this new study, named Lunar COTS (Commercial Operations and Transport Services), was conducted to examine extending the NASA COTS model to cis-lunar space and the lunar surface. The goals of the Lunar COTS concept are to: 1) develop and demonstrate affordable and commercial cis-lunar and surface capabilities, such as lunar cargo delivery and surface power generation, in partnership with industry; 2) incentivize industry to establish economical and sustainable lunar infrastructure services to support NASA missions and initiate lunar commerce; and 3) encourage creation of new space markets for economic growth and benefit. A phased-development approach was also studied to allow for incremental development and demonstration of capabilities needed to build a lunar infrastructure. This paper will describe the Lunar COTS concept goals, objectives and approach for building an economical and sustainable lunar infrastructure. It will also describe the technical challenges and advantages of developing and operating each infrastructure element. It will also describe the potential benefits and progress that can be accomplished in the initial phase of this Lunar COTS approach. Finally, the paper will also look forward to the potential of a robust lunar industrialization environment and its potential effect on the next 50 years of space exploration.

Zuniga, Allison F.↗

MOD-OA 200 kW wind turbine generator engineeringing

Engineering drawings and the detailed mechanical and electrical design of a horizontal-axis wind turbine designed for DOE at the NASA Lewis Research Center and installed in Clayton, New Mexico are discussed. The drawings show the hub, pitch change mechanism, drive train, nacelle equipment, yaw drive system, tower, foundation, electrical power systems, and the control and safety systems.

Andersen, T. S.↗