At least 109 records · Page 6

A Framework for Addressing Hydropower Modeling Gaps in Electric Grid Planning and Operational Studies [Slides]

Realistic representation of hydropower in power system planning and operation studies is extremely important as it helps in avoiding under/over-estimation of the services the hydro power units can provide. A framework and tools have been developed to account for hydrological conditions and modify power system models accordingly. For example, HyDat – data and AI driven platform, that provides that data required for editing the power system model files Collaborative effort with V&R Energy. Also, development of POM based tools have been performed, a) Tool1: editing .raw files with realistic current and maximum hydrogeneration and redispatch of other units, and b) Tool2: Editing .dyr files to represent water head, current and maximum generation. Finally the framework, HASP framework combines HyDat and V&R energy tools to produce modified power system model files. Key Take-away points from contingency analysis studies include a) the number of critical contingencies increases as the water levels are reduced (70%>75%>80%), and b) both the extent and the quality of dynamic response of the Hydropower unit is different with varying water head levels.

13 HYDRO ENERGY↗

Hardware-in-the-Loop Simulation of a Distribution System with Air Conditioners under Model Predictive Control: Preprint

Many have proposed that responsive load provided by distributed energy resources (DERs) and demand response (DR) are an option to provide flexibility to the grid and especially to distribution feeders. However, because responsive load involves a complex interplay between tariffs and DER and DR technologies, it is challenging to test and evaluate options without negatively impacting customers. This paper describes a hardware-in-the-loop (HIL) simulation system that has been developed to reduce the cost of evaluating the impact of advanced controllers (e.g., model predictive controllers) and technologies (e.g., responsive appliances). The HIL simulation system combines large-scale software simulation with a small set of representative building equipment hardware. It is used to perform HIL simulation of a distribution feeder and the loads on it under various tariff structures. In the reported HIL simulation, loads include many simulated air conditioners and one physical air conditioner. Independent model predictive controllers manage operations of all air conditioners under a time-of-use tariff. Results from this HIL simulation and a discussion of future development work of the system are presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Interaction of Grid-Forming and Grid-Following Inverters with Synchronous Generators in Hybrid Power Plants

As the integration of renewable energy resources such as wind and solar generation continues to grow, the use of hybrid power plants with both synchronous machines and power electronic inverters operating in parallel becomes more common. This paper studies the impact on small-signal stability for these pairs of devices, first as an isolated two-device system and then as part of a 9-bus test system. Each operational scenario was studied with both a grid-following inverter and a grid-forming inverter. In each scenario, the state variables associated with the synchronous generator's excitation system were found to be responsible for the inception of instability. These results underscore the importance of accurate modeling of excitation systems when modeling power systems with hybrid power plants.

hybrid power plant↗

A Structure-Preserving Model and Sufficient Condition for Frequency Synchronization of Lossless Droop Inverter-Based AC Networks

This paper presents a new method for analysis of frequency synchronization of lossless power networks whose sources are frequency-droop controlled inverters. Unlike most existing approaches, our method focuses on the interaction between inverters and the network to provide new physical insight into how those interactions create frequency synchronization. We introduce two structure-preserving models of such a network (one bus-oriented and one line-oriented), and show that frequency synchronization corresponds to convergence to an equilibrium of these models. We derive a necessary condition for existence of such equilibria, and determine a simple test for their local stability. Finally, we introduce a sufficient condition for frequency synchronization of such networks, and show that it consists of a set of local criteria which can each be determined from local measurements.

Distributed control↗

Hy-DAT: A Tool to Address Hydropower Modeling Gaps Using Interdependency, Efficiency Curves, and Unit Dispatch Models

As the power system continues to be flooded with intermittent resources, it becomes more important to accurately assess the role of hydro and its impact on the power grid. While hydropower generation has been studied for decades, dependency of power generation on water availability and constraints in hydro operation are not well represented in power system models used in the planning and operation of large-scale interconnection studies. There are still multiple modeling gaps that need to be addressed; if not, they can lead to inaccurate operation and planning reliability studies, and consequently to unintentional load shedding or even blackouts. As a result, it is very important thathydropower is represented correctly in both steady-state and dynamic power system studies. In this paper, we discuss the development and use of the Hydrological Dispatch and Analysis Tool (Hy-DAT) as an interactive graphical user interface (GUI), that uses a novel methodology to address the hydropower modeling gaps like water availability and inter-dependency using a database, and algorithms, to generate accurate representative models for power system simulation.

Wang, Dewei↗

Representation and Impact of Water Head on Power System Planning and Operation

Representing water head information in power system model files, can provide a more realistic model of the system and thereby inform operation and planning personnel in the decision-making process. This article describes a procedure for modifying the power system model files (steady-state and dynamic) to represent water head information. Additionally, the impact of representing the water head on power system reliability studies including contingency analysis, cascading failure analysis and dynamic frequency response analysis has been investigated, using the modified power system models. This paper considers the detailed Western Electricity Coordination Council model during summer and winter conditions as the test system for the impact analysis. Results show that under reduced water head: 1) the number of critical voltage and branch flow violations increases; 2) chances of cascading failure and island formation increases; and 3) frequency nadir decreases as compared to those of the base cases where the water head information is not represented.

13 - HYDRO ENERGY↗

Electric Aircraft Propulsion Power System Impedance Modelling Methodology

This paper describes techniques to be used to model megawatt Electrified Aircraft Propulsion (MW EAP) components, specifically motor/generators and inverters, DC-DC converters, and long power leads; resulting in impedance-based models which require no information from the component manufacturers. A custom curve fitting method is described, and an example power supply model is fit using measured impedance data. A method called subscale measurement, employing measurement equipment which has much lower power capability than the MW EAP system under test, is described, simulated, and used to generate an impedance transfer function model of a load. Finally, stability analysis using a Nyquist based approach is performed on the combined supply and load system, using the generated models.

Megawatt electrified aircraft propulsion↗

Methods for Computing Physically Realistic Estimates of Electric Water Heater Demand Response Resource Suitable for Bulk Power System Planning Models

Demand response is commonly called on to reduce load during system peak times or to respond to contingency events. In future power systems with higher shares of wind and solar generation (which we describe together as variable generation [VG]), demand response could have more opportunities to provide energy shifting or operating reserve services. This report evaluates the ability of residential electric water heaters, both electric resistance water heaters (ERWHs) and heat pump water heaters (HPWHs), to provide such services starting from detailed whole-building energy models that realistically represent New England single family home stock. We use a parsimonious surrogate model to represent operational flexibility in a form suitable for linear and mixed integer programming. This enables relatively fast determination of aggregate contingency reserve resource, price-taking energy shifting outcomes, and in some cases the determination of aggregate models at the megawatt (MW) scale that can be directly included in large-scale grid models. After selecting modeling methods and parameters through various computational experiments, we find interquartile ranges of contingency reserve resource in ISO-NE for about 603,400 ERWHs of 45 MW - 69 MW for Claim10 (50 minute responses provided with 10 minutes of advanced notification) and 65 MW - 102 MW for Claim30 (30 minute responses provided with 30 minutes of advanced notification), and for about 619,000 HPWHs of 48 MW - 88 MW for Claim10 and 52 MW - 90 MW for Claim30. The overall reserve resource is up to 32% of total load for ERWHs providing Claim10 service, 47% for ERWHs providing Claim30 service, 93% for HPWHs providing Claim10 service, and 97% for HPWHs providing Claim30 service. More work is required to determine if HPWHs are inherently more suitable than ERWHs for providing contingency reserve or if these results reflect idiosyncrasies of the single family home stock model used in this study. The value of this contingency resource in a Near-term VG model of ISO-NE is $\$ 0.40$ to $\$1.20$ per water heater-year, and significantly larger, $\$ 3.80$ to $\$ 5.30$ per water heater-year in a Mid-term VG model of ISONE. Aggregating surrogate models to the MW-scale for energy shifting service is more challenging than for contingency service and we only present such results for ERWHs, because we were unable to determine satisfactory ways to deal with HPWHs' time-varying and path dependent operational characteristics. Individual surrogate models suitable for evaluating the energy shifting resource from both ERWHs and HPWHs are created, however, and dispatched against day-ahead prices from the Near-Term VG and Mid-Term VG models of ISO-NE. The individual surrogate models are able to access and potentially shift all 640 GWh of HPWH load and 1,547 GWh of ERWH load we modeled in two different single family home stock models. In contrast, the most effective model of aggregate ERWH shifting resource we created only captured 34.7% of the total ERWH load. Energy shifting affected by price-taking dispatch against modeled day-ahead energy prices produces per water heater year profits of $\$19.44$ - $\$22.93$ for individual HPWHs, $\$39.11$ - $\$40.54$ for individual ERWHs, and up to $\$4.00$ - $\$4.24$ for aggregated ERWHs, with the variations mainly due to grid conditions (more or less VG). When the supply-side response to these changes is accounted for, the per water heater year production cost savings for ISO-NE are $\$7.50$ to $\$17.70$ for the most effective set of endogenously dispatched aggregate ERWHs, $\$15.60$ to $\$15.70$ for individual ERWHs dispatched against the DA prices, and $\$10.70$ to $\$11.20$ for individual HPWHs dispatched against DA prices. Those ranges primarily represent the difference between Near-Term VG and Mid-Term VG grid conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Open Source Modeling for Power Systems Dynamics

Time-domain simulations for power systems (both phasor and electromagnetic transients) are mostly dominated by commercial tools, such as PSS/E or PSCAD. However, with the increasing penetration of inverter-based resources and changes in model paradigm, new open-source tools are looking into become a possible alternative for a range of stakeholders. In this presentation we will focus on how to improve communication with industry and other stakeholders to properly showcase the value of open source simulators. Participants will identify current barriers facing the adoption of open-source time-domain tools, and will discuss how to improve the bench-marking processes across different tools, while maintaining software modularity to include new features and models as new challenges continue to happen in energy systems.

ENERGY PLANNING, POLICY, AND ECONOMY,MATHEMATICS A↗

A Power Application Developer’s Guide to the Common Information Model: An Introduction for Power Systems Engineers and Application Developers – CIM17v40

A key issue in creating the next generation of energy management system (EMS) and advanced distribution management system (ADMS) platforms will be the ability to represent and exchange power system network model data in a consistent manner. To this end, the Common Information Model (CIM) stands out as the only standardized vocabulary (or ontology) for defining power system network models and asset data in a comprehensive, consistent manner across the generation-transmission-distribution boundary. The CIM is freely available to use and extend. The CIM is maintained by the UCAiug (informally known as the CIM User’s Group) under an Apache 2.0 license. The CIM Users Group collaborates with the IEC and other standards communities for the development of technical and informative specifications. Although portions of the information model are referred to by the corresponding IEC standards naming, it is not necessary to purchase any of the IEC standards to use the CIM information model. This document provides a roadmap for power system engineers and application developers not familiar with semantic modeling to start using the CIM for modeling, simulation, optimization, and development of advanced power applications. The key classes needed for defining power system topology and equipment are explained systematically. Key focus areas include modeling of lines, transformers, generators, switching equipment, loads, and distributed energy resources (DERs).

97 MATHEMATICS AND COMPUTING↗

The Potential Role for New Nuclear in the U.S. Power System: A View from Electricity System Modelers

There are diverse views on the role nuclear power might play in a decarbonized energy system, with some vocal viewpoints suggesting nuclear should either have no role or that nuclear should be a key pillar. Here we present a perspective on the role of nuclear power based on our collective experience in modeling nuclear power within the decarbonized U.S. power systems. We summarize the costs of current reactor development projects, and compare their stated costs with the costs that our models indicate is necessary in order to see deployment of new nuclear. We also discuss aspects of new nuclear deployment that are not included in our models but can influence decisions about whether to invest in new nuclear capacity.

decarbonization↗

Solar Uncertainty Management and Mitigation for Exceptional Reliability in Grid Operations (SUMMER-GO): Project Final Report

The Solar Uncertainty Management and Mitigation for Exceptional Reliability in Grid Operation (SUMMER-GO) project was recently completed through a collaboration among the National Renewable Energy Laboratory, Maxar, the Electric Reliability Council of Texas (ERCOT), the University of Texas at Dallas, the University of California Berkeley, and the University of Colorado Boulder. The project made significant advances in probabilistic solar power forecasting, both through the development of Bayesian model averaging methods for ensemble forecasting and in bringing these and other advancements into practice with Maxar's delivery of operational forecasts to ERCOT. In addition to creating more reliable solar power forecasts, the project developed methods for their utilization in power system operations. These include the development of risk-aware unit commitment and economic dispatch algorithms and methods to reformulate probabilistic forecasts to be used in these power system operational models. Dynamic power system reserve methods were also developed, which have been shown in silico to create economic savings and reliability improvements on an ERCOT-like system as well as financial savings in the ERCOT system through more granular consideration of the uncertainty associated with solar power forecasts. Finally, a situational awareness tool to help grid operators better understand solar power forecast uncertainty in daily operations was developed and extensively vetted.

14 SOLAR ENERGY↗

Power Conditioning System Modelling for Nuclear Electric Propulsion

NASA LeRC is currently developing a Fortran based model of a complete nuclear electric propulsion (NEP) vehicle that would be used for piloted and cargo missions to the Moon or Mars. The proposed vehicle design will use either a Brayton or K-Rankine power conversion cycle to drive a turbine coupled with a rotary alternator. Two thruster types are also being studied, ion and magnetoplasmadynamic (MPD). In support of this NEP model, Rocketdyne developed a power management and distribution (PMAD) subroutine that provides parametric outputs for selected alternator operating voltages and frequencies, thruster types, system power levels, and electronics coldplate temperatures. The end-to-end PMAD model described is based on the direct use of the alternator voltage and frequency for transmitting power to either ion or MPD thrusters. This low frequency transmission approach was compared with dc and high frequency ac designs, and determined to have the lowest mass, highest efficiency, highest reliability and lowest development costs. While its power quality is not as good as that provided by a high frequency system, it was considered adequate for both ion and MPD engine applications. The low frequency architecture will be used as the reference in future NEP PMAD studies.

Metcalf, Kenneth J.↗

Calibrating Parameters of Power System Stability Models Using Advanced Ensemble Kalman Filter

With the ever increasing penetration of renewable energy, smart loads, energy storage, and new market behavior, today's power grid becomes more dynamic and stochastic, which may invalidate traditional study assumptions and pose great operational challenges. Thus, it is of critical importance to maintain good-quality models for secure and economic planning and real-time operation. Following the 1996 Western Systems Coordinating Council (WSCC) system blackout, North American Electric Reliability Corporation (NERC) and Western Electricity Coordinating Council (WECC) in North America enforced a number of policies and standards to guide the power industry to periodically validate power grid models and calibrate poor parameters with the goal of building sufficient confidence in model quality. The PMU-based approach using online measurements without interfering with the operation of generators provides a low-cost alternative to meet NERC standards. This paper presents an innovative procedure and tool suites to validate and calibrate models based on a trajectory sensitivity analysis method and an advanced ensemble Kalman filter algorithm. The developed prototype demonstrates excellent performance in identifying and calibrating bad parameters of a realistic hydro power plant against multiple system events.

Huang, Renke (ORCID:0000000230947073)↗

Voltage Stability Assessment Using Synchronized Phasor Measurements Applied to the Argentine Power System

This paper presents tests of different methods for long term voltage stability analysis based on PMU measurements. In particular, Thevenin Impedance Matching and sensitivity calculation are studied. Simulation are performed in a modified Argentine power system model, to include the main components for studying long term voltage stability. Disconnection of a large Thermal Generating Station causing long-term voltage instability at Gran Buenos Aires Area is studied. It is shown that computing the apparent impedance of Thevenin equivalent at load bus from measurements taken at a single time but at various locations of the transmission corridor produce a significant reduction of the estimation error produce when only local measurements are used. Voltage Stability analysis is performed using a reduced power system model where changing parameters are fully computed through PMU data at each time. Over this reduced power system model, voltage stability index and sensibility calculations are performed.

Gill-Estebez, Pablo↗

Risk Assessment of Rare Events in Probabilistic Power Flow via Hybrid Multi-Surrogate Method

The risks associated with rare events threatening the security of power system operation are of paramount importance to power system planners and operators. To analyze the risks caused by high-impact, low-frequency rare events, an immensely large number of samples are typically required for the Monte-Carlo (MC) method on the high-fidelity power system model to achieve a sufficient accuracy, thereby rendering this approach computationally prohibitive. To handle this problem efficiently, it is desirable to construct a surrogate model for the power system response. However, the straightforward MC sampling of the low-fidelity surrogate can lead to biased results in the low-probability tail regions that are vital to risk assessment. Moreover, a single surrogate is unable to handle the topology uncertainties caused by random branch outages. To overcome these issues, we propose a hybrid multi-surrogate (HMS) method based on the polynomial chaos expansion (PCE) with low-probability tail events reevaluated by the high-fidelity model through a probabilistic analysis. This method improves the computational efficiency of the MC method for rare-event risk assessment by leveraging multi-fidelity models while retaining the desired accuracy. Simulations conducted in three test systems verify the excellent performances of the HMS method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling of power electronic systems with EMTP

In view of the potential impact of power electronics on power systems, there is need for a computer modeling/analysis tool to perform simulation studies on power systems with power electronic components as well as to educate engineering students about such systems. The modeling of the major power electronic components of the NASA Space Station Freedom Electric Power System is described along with ElectroMagnetic Transients Program (EMTP) and it is demonstrated that EMTP can serve as a very useful tool for teaching, design, analysis, and research in the area of power systems with power electronic components. EMTP modeling of power electronic circuits is described and simulation results are presented.

Tam, Kwa-Sur↗

A Semantic Search Capability for a Grid Model Repository

The operation of electric grids is becoming more challenging due to continued increases in wind and solar generation, the proliferation of decentralization generation resources, and cyber security threats. To support the needed research, new large scale realistic public grid models have been developed and placed in a repository for access by researchers. To assist researchers in easily finding grid models that are suitable for their specific research needs, an approach to searching numerous large grid models was evaluated, prototyped and developed. Here, the research identified multiple possible approaches to using graph database techniques and a natural language processing for the search algorithm. Results of the prototype, the final approach for production repository and the search algorithm formulation are described.

24 POWER TRANSMISSION AND DISTRIBUTION↗