Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power system reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

System Study: High-Pressure Coolant Injection 1998-2024

This report presents an unreliability evaluation of the high-pressure coolant injection (HPCI) system at 22 U.S. commercial operating boiling water reactors. New Standardized Plant Analysis Risk (SPAR) models with the most recent SPAR parameter update results were used in this report. Demand, run hour, and failure data from 1998 to 2024 for selected components were obtained from the Institute of Nuclear Power Operations Industry Reporting and Information System. The unreliability results are trended for the most recent 10 year period and yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPCI results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

System Study: Auxiliary Feedwater 1998-2024

This report presents an unreliability evaluation of the auxiliary feedwater (AFW) system at 62 U.S. commercial operating nuclear reactors. New Standardized Plant Analysis Risk (SPAR) models with the most recent SPAR parameter update results were used in this report. Demand, run hour, and failure data from calendar years 1998 to 2024 for selected components were obtained from the Institute of Nuclear Power Operations Industry Reporting and Information System. The unreliability results are trended for the most recent 10 year period and yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the industry-wide estimates of AFW system start-only unreliability, but a statistically significant decreasing trend was identified in the industry-wide estimates of AFW system 24-hour mission unreliability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

System Study: High-Pressure Core Spray 1998-2024

This report presents an unreliability evaluation of the high-pressure core spray (HPCS) at eight U.S. commercial operating boiling water reactors. New Standardized Plant Analysis Risk (SPAR) models with the most recent SPAR parameter update results were used in this report. Demand, run hour, and failure data from 1998 to 2024 for selected components were obtained from the Institute of Nuclear Power Operations Industry Reporting and Information System. The unreliability results are trended for the most recent 10-year period and yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPCS results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

System Study: High-Pressure Safety Injection 1998-2024

This report presents an unreliability evaluation of the high-pressure safety injection system (HPSI) at 62 U.S. commercial operating nuclear reactors. New Standardized Plant Analysis Risk (SPAR) models with the most recent SPAR parameter update results were used in this report. Demand, run hour, and failure data from calendar years 1998 to 2024 for selected components were obtained from the Institute of Nuclear Power Operations Industry Reporting and Information System. The unreliability results are trended for the most recent 10-year period and yearly estimates for system unreliability are provided for the entire active period. Statistically significant decreasing trends were identified in both the HPSI system start-only unreliability and 24-hour mission unreliability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced Power Electronics and Electric Machines

The advanced power electronics and electric machines (APEEM) research group at the National Renewable Energy Laboratory (NREL) has developed world-class experimental and modeling capabilities for designing and evaluating efficient and reliable power electronics and electric machines thermal management systems. They also design, fabricate and characterize advanced power electronics packaging, and are developing state-of-health monitoring techniques. These researchers deliver safe, reliable, high performing, power-dense components that allow seamless integration between renewable energy sources, electric transportation, and the grid, helping to make widespread electric vehicle (EV) adoption and greenhouse gas emissions reduction more feasible. This document outlines the group's major capabilities in the areas of power electronics; module development and characterization; thermal modeling and management; thermomechanical reliability analysis of devices, modules, inverters/converters, and electric machines; physics-of-failure-based reliability analysis; and microelectronics. It also overviews the group's state-of-the-art equipment for fluid-based thermal management; thermal measurement & characterization; thermomechanical reliability analysis; micro- and power electronics measurement & characterization; and prototype fabrication, as well as the group's world-class modeling and simulation capabilities.

advanced gate drivers↗

Power modeling of degraded PV systems: Case studies using a dynamically updated physical model (PV-Pro)

Power modeling, widely applied for health monitoring and power prediction, is crucial for the efficiency and reliability of Photovoltaic (PV) systems. The most common approach for power modeling uses a physical equivalent circuit model, with the core challenge being the estimation of model parameters. Traditional parameter estimation either relies on datasheet information, which does not reflect the system's current health status, especially for degraded PV systems, or requires additional I-V characterization, which is generally unavailable for large-scale PV systems. Thus, we build upon our previously developed tool, PV-Pro (originally proposed for degradation analysis), to enhance its application for power modeling of degraded PV systems. PV-Pro extracts model parameters from production data without requiring I-V characterization. This dynamic model, periodically updated, can closely capture the actual degradation status, enabling precise power modeling. PV-Pro is compared with popular power modeling techniques, including persistence, nominal physical, and various machine learning models. The results indicate that PV-Pro achieves outstanding power modeling performance, with an average nMAE of 1.4 % across four field-degraded PV systems, reducing error by 17.6 % compared to the best alternative technique. Furthermore, PV-Pro demonstrates robustness across different seasons and severities of degradation. The tool is available as a Python package at https://github.com/DuraMAT/pvpro.

14 SOLAR ENERGY↗

Model-Based Approaches to Generate Knowledge from Data in a Plant Reliability Context

One challenge that nuclear power plant system engineers are facing is continuous generation of an extremely large amount of equipment reliability (ER) data. These data elements come in textual (e.g., condition reports) and numeric (e.g., generated by monitoring systems) forms. They provide system engineers with valuable insights and information by discovering anomalous behaviors or degradation trends, identifying possible causes behind such behaviors and trends, and predicting their direct consequences. This paper directly targets the knowledge generation from ER data by putting “data into context.” We employ model-based system engineering (MBSE) of systems and assets to represent and capture their architecture and functional (i.e., cause-effect) relations. ER data elements are processed by first identifying which of the developed MBSE elements they are referring to. This task is harder for textual data since the information contained in issue or maintenance reports needs to be “understood” by a computational tool. We called this process “knowledge extraction” since our methods extract knowledge from textual data. Last, once numeric and textual ER data elements have been processed and “understood,” we discover possible cause-effect relations among them. This is performed by observing whether a logical connection through the MBSE models exists, and if there is a temporal relationship among them. The logic and temporal are the two main ingredients to perform “machine reasoning” from ER data.

97 - MATHEMATICS AND COMPUTING↗

Reliable Protection for an Inverter-Based Resources Dominant Grid: Technology Development and Field Demonstration

The project aimed to address the challenges posed by the rapid growth of inverter-based resources (IBR) such as solar, wind, and battery storage, which have fundamentally changed fault behavior, system strength, and protection performance in bulk power systems. Traditional protection schemes, designed for synchronous generator-dominated grids, are inadequate under high IBR penetration. Overall, the project materially advances protection modeling and simulation capabilities needed to maintain reliable grid protection under high IBR penetration. The results build utility confidence in operating power systems safely and reliably across a wide range of generation mixes, supporting grid modernization goals.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MULTI-FIDELITY MODELING AND UNCERTAINTY QUANTIFICATION OF INVERTER BASED RESOURCES IN INTEGRATED T&D SYSTEMS

Uncertainty quantification plays a pivotal role in improving the accuracy and reliability of inverter operation within modern power systems that are increasingly dominated by inverter-based resources (IBRs). IBRs, especially those operating under grid forming (GFM) control, rely heavily on a complex set of control parameters and system measurements to maintain voltage, frequency, and power balance. Traditional deterministic modeling approaches often fail to capture these parameter deviations, potentially resulting in suboptimal control actions, reduced system stability, or even instability under high penetration of IBRs. In this paper, we demonstrate the application of model calibration and uncertainty quantification (UQ) principles to an integrated transmission and distribution (T&D) model involving a GFM converter and provide a framework for prioritizing control improvements, guiding robust design, and informing adaptive strategies that can accommodate real-time variability in system conditions. The proposed approach could be valuable in enhancing the robustness of current and future power systems under increased IBR penetrations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analytical Identification Method of Generalized Short‐Circuit Ratio Using Phasor Measurement Units

This paper introduces a novel analytical approach for the identification of the admittance matrix and the generalized short-circuit ratio (gSCR) in power systems integrated with renewable energy sources. The proposed method leverages voltage and current measurements from phasor measurement units (PMUs) to construct a least squares objective function, which is then solved using matrix calculus and partial derivatives. Unlike conventional optimization algorithms, this approach provides an analytical solution that substantially reduces data requirements, enabling the efficient and accurate identification of the gSCR with smaller datasets. Additionally, its fixed computational complexity allows for real-time updates as new data are collected, ensuring continuous refinement of the system of equations and enabling rapid, precise gSCR calculations. The method also exhibits strong robustness against measurement noise, making it well-suited for practical applications in dynamic power systems. The combination of reduced data requirements, real-time adaptability, noise robustness and fixed computational load establishes this method as a highly efficient and reliable tool for real-time power system stability analysis. Case studies on an EPRI 36-bus system demonstrate the method's effectiveness, highlighting its accuracy in closely matching true gSCR values, even under diverse disturbances and noisy conditions.

Han, Zelei [Hohai University, Nanjing (China)] (OR↗

Transmission Operator Workflows for Real-Time Reliability Studies: A Review of Control Room Practices and Naturalistic Decision Making

This report provides an overview of real-time reliability study tools and their use by power system operators in the control room environment. After introducing some of the nuances of the control room environment and the differences in perspectives between power system engineers and operators, the roles and responsibilities of key entities involved in RTCA workflows are introduced. These are specifically the transmission system operator (TOP) and reliability coordinator (RC), which are required to run tools such as real-time contingency analysis (RTCA) as part of a real-time reliability assessment every 30 minutes, as dictated by a series of standards issued by the North American Electric Reliability Corporation (NERC). The process by which power systems operators operate the grid is discussed in terms of naturalistic decision making (NDM) and the recognition-primed decision-making (RPD) model. This cognitive model describe how experts working in high-risk, high-stress environments make safety-critical decisions under uncertainty and time pressure. For power system operators, the mental simulations involved in the traditional RPD model are supplemented by physics-based simulations using numerical tools, such as RTCA, to improve situational awareness and effectiveness of control actions. Next, a generic workflow is introduced to describe operator decision making for running RTCA tools and responding to system violations on a pre-contingent basis. The types of analysis performed and control actions chosen by power system operators are described in detail. The overall high-level workflow is then expanded in subsequent sections, with special attention given to high-voltage violations, low-voltage violations, and thermal overloads. Each type of violation is described in detail, with explanations of common causes, impacts on equipment and customers, and mitigation strategies. An additional workflow diagram is provided for each type of violation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Best Practices for Grid Communications

As the grid evolves, the communications architecture will need to evolve with it. That architecture affords a structured means by which the evolving complexities of the modern electric grid can be managed. This document provides best practices that can be implemented in the grid of today and evolve towards the grid and grid architecture of the future. The evolving grid and its control communications increasingly rely on commercial communications providers and a variety of technologies, from wireless (e.g., 5G, microwave, Wi-Fi) to wireline (fiber, copper) to radio communications (P25, other repeater-based systems), and all these communications systems rely on electric power. A reliable and resilient grid must account for this complex set of interdependencies in its planning activities, especially those involving restoration and recovery. The participation of all relevant parties in both planning and exercising of plans can prevent unexpected conditions that impede the reliable operation and recovery of the grid. Best practices for grid communications include using a Network Management System to document the operational state, define and monitor baselines, detect changes, and accelerate response to abnormalities. If transitioning from SONET to IP/packet-based systems, translating grid requirements into communications requirements for latency, bandwidth and throughput, IP packet delay variation, packet loss, and availability should inform and drive technology planning and selection as well as that communication system’s Quality of Service (QoS) policies and Service Level Agreements (SLAs). Secure and reliable timing is another key component of a reliable and resilient grid that can operate through adverse events. A trusted internal NTP configuration, an integrated and diverse timing delivery system, optimizing the timing architecture based on the transport technologies of the communications system, and using established standards can deliver the level of timing accuracy required by a range of time-sensitive power system applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ECAR-7517 Rev 1 MARVEL I&C Failure Modes and Effects Analysis

The purpose of this document is to perform a single-failure analysis through the use of a Failure Modes and Effects Analysis (FMEA) for the Safety Related components of the MARVEL Instrumentation and Control (I&C) System. The intent is that this document will meet the requirements for a single-failure analysis described in IEEE-379, “IEEE Standard for Application of the Single-Failure Criterion to Nuclear Power Generating Station Safety Systems”, to verify that this design does indeed meet the single failure criterion. Principles of IEEE-352, “IEEE Guide for General Principles of Reliability Analysis of Nuclear Power Generating Station Safety Systems” are followed to ensure the analysis is consistent with industry standards.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

A resource adequacy assessment of correlated wide-area outages in the power grid

As the power grid is undergoing rapid transformations, numerous questions are emerging about its vulnerability to wide-area extreme events (WAEE), which could influence its operations. Relatively few analyses have been conducted to date regarding the impact of correlated outages during WAEEs on the grid’s ability to balance resources with demand. This study addresses this gap by conducting a resource adequacy analysis for a hurricane-inspired WAEE on a 2035 synthetic power grid system for the United States. A sensitivity analysis was also conducted to characterize the relative impact of weather on unserved energy. Our results indicate that although the magnitude and duration of the shortfalls vary depending on weather conditions, persistent shortfalls are observed in some regions. Initial explorations indicate a strong correlation between transmission-constrained regions and regions with persistent shortfalls. Future work could generate empirically-grounded representations for generator outages as well as conduct causal analyses of these shortfalls to improve understanding of drivers as well as possible mitigation strategies. Continued exploration of extreme weather impacts on the grid is important to develop more robust understanding of the reliability and resilience of our power systems, especially as they undergo rapid transformations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Active Learning of Microgrid Frequency Dynamics Using Neural Ordinary Differential Equations

Accurate frequency modelling of inverter‐based resource (IBR)‐dominated power systems is crucial for ensuring stable, reliable and resilient operations, particularly given their inherent low‐inertia characteristics and fast dynamics that traditional swing equation‐based models inadequately capture. This paper explores neural ordinary differential equations (Neural ODEs) as a computationally efficient, data‐driven framework for modelling power system frequency dynamics, specifically within microgrids integrating high penetrations of distributed energy resources (DERs). The developed neural ODEs framework incorporates a neural network architecture designed to capture input dynamics. By actively perturbing the system with a known signal, the Python‐based neural ODEs framework was trained using measured system states and inputs, without the need for detailed system information. The framework, tested on a model of the Cordova, AK, microgrid, achieved a goodness of fit ranging from 60% to 99% across different state variables and maintained a mean square error in the 10 -6 p.u. range under square and step excitation signals. The proposed approach demonstrated robustness to measurement noise and initial condition variations while maintaining low computational complexity suitable for real‐time power system control applications. Furthermore, transfer learning enabled the neural ODEs model to adapt to the following changes in system topology or generator dispatch, highlighting its effectiveness for dynamic microgrids with frequently evolving configurations and diverse DERs.

Aryal, Tara [South Dakota State Univ., Brookings, ↗

A bi-level advanced control framework for large-scale control of buildings with system-level impact

Increased electricity consumption combined with new forms of generation is testing the reliability of our grid infrastructure. This work describes a method to improve the reliability of the grid through large-scale advanced building control. This paper develops a bi-level distributed control framework to shift the load of 153 buildings to achieve a system-level objective of tracking a power reference signal. This bi-level control is based on the previously-developed ANPV-MPC, a predictive controller that uses a Bayesian neural network to generate an accurate control model and adapt to changing conditions over time. By shifting the building electricity demand to better match the available power, the grid system supplying the buildings is more reliable as evidenced by the analysis of node voltages across an IEEE 13-bus distribution system. The proposed bi-level control framework tracks the system-level power reference with enough accuracy to regulate node voltages across the IEEE 13-bus distribution system within ANSI limits of ±5%. Additionally, the adaptive nature of ANPV-MPC allows each building across the system to adapt to changing conditions, further amplifying the system-level reliability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New Report Highlights LAMP's Role as a Robust and Reliable System for Wave Energy Converter Testing

Harnessing the power of waves requires more than just putting devices in the ocean - it takes tools that can refine and accelerate innovation before the first deployment. That's where NLR's largeamplitude motion platform, or LAMP, comes in. LAMP is a six-degree-of-freedom motion system designed to replicate the response of a wave energy converter (WEC) device in realistic ocean conditions. By letting researchers evaluate WEC performance in a safe, controlled lab environment before moving offshore, LAMP helps accelerate innovation while reducing risk. An NLR report, titled Initial Characterization of the NLR LargeAmplitude Motion Platform (https://www.nrel.gov/docs/fy26osti/93733.pdf), provides a deeper understanding of LAMP's capabilities and also lays the groundwork for future advancements in WEC testing methodologies. Researchers studied LAMP's amplitude and frequency limits across different payloads and collected data from 16 test profiles. Testing demonstrated that platform accuracy remained consistent across all payloads evaluated; researchers expect similar accuracy up to LAMP's 10,000-kilogram capacity limit. The measured position limits for single degrees of freedom experienced by WECs, including surge, sway, heave, roll, pitch, and yaw, also exceeded the original manufacturer specifications, providing new insight into the true boundaries of the system.

16 TIDAL AND WAVE POWER↗