Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precision Time Protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A transform of complementary aspects with applications to entropic uncertainty relations

Even though mutually unbiased bases and entropic uncertainty relations play an important role in quantum cryptographic protocols, they remain ill understood. Here, we construct special sets of up to 2n+1 mutually unbiased bases (MUBs) in dimension d=2{sup n}, which have particularly beautiful symmetry properties derived from the Clifford algebra. More precisely, we show that there exists a unitary transformation that cyclically permutes such bases. This unitary can be understood as a generalization of the Fourier transform, which exchanges two MUBs, to multiple complementary aspects. We proceed to prove a lower bound for min-entropic entropic uncertainty relations for any set of MUBs and show that symmetry plays a central role in obtaining tight bounds. For example, we obtain for the first time a tight bound for four MUBs in dimension d=4, which is attained by an eigenstate of our complementarity transform. Finally, we discuss the relation to other symmetries obtained by transformations in discrete phase space and note that the extrema of discrete Wigner functions are directly related to min-entropic uncertainty relations for MUBs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-Time US-CT/MRI Image Fusion for Guidance of Thermal Ablation of Liver Tumors Undetectable with US: Results in 295 Cases

PurposeThis study was designed to assess feasibility of US-CT/MRI fusion-guided ablation in liver tumors undetectable with US.MethodsFrom 2002 to 2012, 295 tumors (162 HCCs and 133 metastases; mean diameter 1.3 ± 0.6 cm, range 0.5–2.5 cm) detectable on contrast-enhanced CT/MRI, but completely undetectable with unenhanced US and either totally undetectable or incompletely conspicuous with contrast-enhanced US (CEUS), were treated in 215 sessions using either internally cooled radiofrequency or microwave with standard ablation protocols, guided by an image fusion system (Virtual Navigation System, Esaote S.p.A., Genova, Italy) that combines US with CT/ MRI images. Correct targeting and successful ablation of tumor were verified after 24 hours with CT or MRI.ResultsA total of 282 of 295 (95.6 %) tumors were correctly targeted with successful ablation achieved in 266 of 295 (90.2 %). Sixteen of 295 (5.4 %) tumors were correctly targeted, but unsuccessfully ablated, and 13 of 295 (4.4 %) tumors were unsuccessfully ablated due to inaccurate targeting. There were no perioperative deaths. Major complications were observed in 2 of the 215 treatments sessions (0.9 %).ConclusionsReal-time virtual navigation system with US-CT/MRI fusion imaging is precise for targeting and achieving successful ablation of target tumors undetectable with US alone. Therefore, a larger population could benefit from ultrasound guided ablation procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Contrast-Enhanced Proton Radiography for Patient Set-up by Using X-Ray CT Prior Knowledge

Purpose: To obtain a contrasted image of the tumor region during the setup for proton therapy in lung patients, by using proton radiography and x-ray computed tomography (CT) prior knowledge. Methods and Materials: Six lung cancer patients' CT scans were preprocessed by masking out the gross tumor volume (GTV), and digitally reconstructed radiographs along the planned beam's eye view (BEV) were generated, for a total of 27 projections. Proton radiographies (PR) were also computed for the same BEV through Monte Carlo simulations. The digitally reconstructed radiograph was subtracted from the corresponding proton image, resulting in a contrast-enhanced proton radiography (CEPR). Michelson contrast analysis was performed both on PR and CEPR. The tumor region was then automatically segmented on CEPR and compared to the ground truth (GT) provided by physicians in terms of Dice coefficient, accuracy, precision, sensitivity, and specificity. Results: Contrast on CEPR was, on average, 4 times better than on PR. For 10 lateral projections (±45° off of 90° or 270°), although it was not possible to distinguish the tumor region in the PR, CEPR offers excellent GTV visibility. The median ± quartile values of Dice, precision, and accuracy indexes were 0.86 ± 0.03, 0.86 ± 0.06, and 0.88 ± 0.02, respectively, thus confirming the reliability of the method in highlighting tumor boundaries. Sensitivity and specificity analysis demonstrated that there is no systematic over- or underestimation of the tumor region. Identification of the tumor boundaries using CEPR resulted in a more accurate and precise definition of GTV compared to that obtained from pretreatment CT. Conclusions: In most proton centers, the current clinical protocol is to align the patient using kV imaging with bony anatomy as a reference. We demonstrated that CEPR can significantly improve tumor visualization, allowing better patient set-up and permitting image guided proton therapy (IGPT)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ansatz-Free Hamiltonian Learning with Heisenberg-Limited Scaling

Learning the unknown interactions that govern a quantum system is crucial for quantum information processing, device benchmarking, and quantum sensing. The problem, known as Hamiltonian learning, is well understood under the assumption that interactions are local, but this assumption may not hold for arbitrary Hamiltonians. Previous methods all require high-order inverse polynomial dependency with precision, unable to surpass the standard quantum limit and reach the gold-standard Heisenberg-limited scaling. Whether Heisenberg-limited Hamiltonian learning is possible without prior assumptions about the interaction structures, a challenge we term ansatz-free Hamiltonian learning , remains an open question. In this work, we present a quantum algorithm to learn arbitrary sparse Hamiltonians without any structure constraints using only black-box queries of the system’s real-time evolution and minimal digital controls to attain Heisenberg-limited scaling in estimation error. Our method is also resilient to state-preparation-and-measurement errors, enhancing its practical feasibility. We numerically demonstrate our ansatz-free protocol for learning physical Hamiltonians and validating analog quantum simulations, benchmarking our performance against the state-of-the-art Heisenberg-limited learning approach. Moreover, we establish a fundamental trade-off between total evolution time and quantum control on learning arbitrary interactions, revealing the intrinsic interplay between controllability and total evolution-time complexity for any learning algorithm. These results pave the way for further exploration into Heisenberg-limited Hamiltonian learning in complex quantum systems under minimal assumptions, potentially enabling new benchmarking and verification protocols.

machine learning↗

SU-E-QI-06: Design and Initial Validation of a Precise Capillary Phantom to Test Perfusion Systems

Purpose: To design a precise perfusion phantom mimicking capillaries of the brain vasculature which could be used to test various perfusion protocols and algorithms which generate perfusion maps. Methods: A perfusion phantom was designed in Solidworks and built using additive manufacturing. The phantom was an overall cylindrical shape of diameter and height 20mm and containing capillaries of 200μm or 300μm which were parallel and in contact making up the inside volume where flow was allowed. We created a flow loop using a peristaltic pump and contrast agent was injected manually. Digital Subtraction Angiographic images and low contrast images with cone beam CT were acquired after the contrast was injected. These images were analyzed by our own code in LabVIEW software and Time-Density Curve, MTT and TTP was calculated. Results: Perfused area was visible in the cone beam CT images; however, individual capillaries were not distinguishable. The Time-Density Curve acquired was accurate, sensitive and repeatable. The parameters MTT, and TTP offered by the phantom were very sensitive to slight changes in the TDC shape. Conclusion: We have created a robust calibrating model for evaluation of existing perfusion data analysis systems. This approach is extremely sensitive to changes in the flow due to the high temporal resolution and could be used as a golden standard to assist developers in calibrating and testing of imaging perfusion systems and software algorithms. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase 1/2 Study of the Addition of Cisplatin to Adjuvant Chemotherapy With Image Guided High-Precision Radiation Therapy for Completely Resected Gastric Cancer

Purpose: Locoregional recurrence is common after surgery for gastric cancer. Adjuvant therapy improves outcomes but with toxicity. This phase 1/2 study investigated infusional 5-fluorouracil (5-FU) in combination with biweekly cisplatin delivered concurrently with image guided high-precision radiation therapy. Methods and Materials: Eligible patients had completely resected stage IB to IV (Union for International Cancer Control TNM 6th edition) nonmetastatic gastric adenocarcinoma. Treatment constituted 12 weeks of infusional 5-FU (200 mg/m{sup 2}/day) with cisplatin added in a standard 3 + 3 dose escalation protocol (0, 20, 30, and 40 mg/m{sup 2}) during weeks 1, 3, 5, and 7, and an additional week 9 dose in the final cohort. Radiation therapy (45 Gy in 25 fractions) was delivered during weeks 3 to 7. Maximum tolerated dose (MTD) was determined in phase 1 and confirmed in phase 2. Results: Among the 55 patients (median age, 54 years; range 28-77 years; 55% male), the median follow-up time was 3.0 years (range, 0.3-5.3 years). Five patients in phase 1 experienced dose-limiting toxicity, and MTD was determined as 4 cycles of 40 mg/m{sup 2} cisplatin. Twenty-seven patients were treated at MTD. Acute grade 3 to 4 toxicity rate was 37.0% at MTD and 29.1% across all dose levels. No treatment-related deaths occurred. Fourteen patients experienced recurrent disease. The 2-year overall survival (OS) and relapse-free survival were 85% and 74%, respectively. Median OS has not been reached. Quality of life (QOL) was impaired during treatment, but most scores recovered by 4 weeks. Conclusion: Cisplatin can be safely delivered with 5-FU–based chemoradiation therapy. Acute toxicity was acceptable, and patient-reported QOL showed the regimen was tolerable. Outcomes are encouraging and justify further study of this regimen.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Testing Protocol for Module Encapsulant Creep (Presentation)

Recently there has been an interest in the use of thermoplastic encapsulant materials in photovoltaic modules to replace chemically crosslinked materials, e.g., ethylene-vinyl acetate. The related motivations include the desire to: reduce lamination time or temperature; use less moisture-permeable materials; or use materials with better corrosion characteristics. However, the use of anythermoplastic material in a high-temperature environment raises safety and performance concerns, as the standardized tests currently do not expose the modules to temperatures in excess of 85C, yet modules may experience temperatures above 100C in operation. Here we constructed eight pairs of crystalline-silicon modules and eight pairs of glass/encapsulation/glass mock modules using differentencapsulation materials of which only two were designed to chemically crosslink. One module set was exposed outdoors with insulation on the back side in Arizona in the summer, and an identical set was exposed in environmental chambers. High precision creep measurements and performance measurements indicate that despite many of these polymeric materials being in the melt state at some of thehighest outdoor temperatures achievable, very little creep was seen because of their high viscosity, temperature heterogeneity across the modules, and in the case of the crystalline-silicon modules, the physical restraint of the backsheet. These findings have very important implications for the development of IEC and UL qualification and safety standards, and in regards to the necessary level ofcure during the processing of crosslinking encapsulants.

14 SOLAR ENERGY↗

SU-F-P-09: A Global Medical Physics Collaboration for Implementation of Modern Radiotherapy in Botswana

Purpose: The global burden of cancer is considerable, particularly in low and middle-income countries. Massachusetts General Hospital (MGH) and Botswana-Harvard AIDS Institute have partnered with the oncology community and government of Botswana to form BOTSOGO (BOTSwana Oncology Global Outreach) to address the rising burden of cancer in Botswana. Currently, radiation therapy (RT) is only available at a single linear accelerator (LINAC) in Gaborone Private Hospital (GPH). BOTSOGO worked to limit the absence of RT during a LINAC upgrade and ensure a safe transition to modern radiotherapy techniques. Methods: The existing Elekta Precise LINAC was decommissioned in November 2015 and replaced with a new Elekta VERSA-HD with IMRT/VMAT/CBCT capability. Upgraded treatment planning and record-and-verify systems were also installed. Physicists from GPH and MGH collaborated during an intensive on-site visit in Botswana during the commissioning process. Measurements were performed using newly purchased Sun Nuclear equipment. Photon beams were matched with an existing model to minimize the time needed for beam modeling and machine down time. Additional remote peer review was also employed. Independent dosimetry was performed by irradiating OSLDs, which were subsequently analyzed at MGH. Results: Photon beam quality agreed with reference data within 0.2%. Electron beam data agreed with example clinical data within 3%. Absolute dose calibration was performed using both IAEA and AAPM protocols. Absolute dose measurements with OSLDs agreed within 5%. Quentry cloud-based software was installed to facilitate remote review of treatment plans. Patient treatments resumed in February 2016. The time without RT was reduced, therefore likely resulting in reduced patient morbidity/mortality. Conclusion: A global physics collaboration was utilized to commission a modern LINAC in a resource-constrained setting. This can be a useful model in other areas with limited resources. Further use of technology and on-site exchanges will facilitate the introduction of more advanced techniques in Botswana. We acknowledge funding support from the AAPM International Educational Activities Committee and the NCI Federal Share Proton Beam Program Income Grant.

60 APPLIED LIFE SCIENCES↗

Performance of a new coaxial ion–molecule reaction region for low-pressure chemical ionization mass spectrometry with reduced instrument wall interactions

Abstract. Chemical ionization mass spectrometry (CIMS) techniques have become prominent methods for sampling trace gases of relatively low volatility. Such gases are often referred to as being “sticky”, i.e., having measurement artifacts due to interactions between analyte molecules and instrument walls, given their tendency to interact with wall surfaces via absorption or adsorption processes. These surface interactions can impact the precision, accuracy, and detection limits of the measurements. We introduce a low-pressure ion–molecule reaction (IMR) region primarily built for performing iodide-adduct ionization, though other adduct ionization schemes could be employed. The design goals were to improve upon previous low-pressure IMR versions by reducing impacts of wall interactions at low pressure while maintaining sufficient ion–molecule reaction times. Chamber measurements demonstrate that the IMR delay times (i.e., magnitude of wall interactions) for a range of organic molecules spanning 5 orders of magnitude in volatility are 3 to 10 times lower in the new IMR compared to previous versions. Despite these improvements, wall interactions are still present and need to be understood. To that end, we also introduce a conceptual framework for considering instrument wall interactions and a measurement protocol to accurately capture the time dependence of analyte concentrations. This protocol uses short-duration, high-frequency measurements of the total background (i.e., fast zeros) during ambient measurements as well as during calibration factor determinations. This framework and associated terminology applies to any instrument and ionization technique that samples compounds susceptible to wall interactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computer-aided measurement of liver volumes in CT by means of geodesic active contour segmentation coupled with level-set algorithms

Purpose: Computerized liver extraction from hepatic CT images is challenging because the liver often abuts other organs of a similar density. The purpose of this study was to develop a computer-aided measurement of liver volumes in hepatic CT. Methods: The authors developed a computerized liver extraction scheme based on geodesic active contour segmentation coupled with level-set contour evolution. First, an anisotropic diffusion filter was applied to portal-venous-phase CT images for noise reduction while preserving the liver structure, followed by a scale-specific gradient magnitude filter to enhance the liver boundaries. Then, a nonlinear grayscale converter enhanced the contrast of the liver parenchyma. By using the liver-parenchyma-enhanced image as a speed function, a fast-marching level-set algorithm generated an initial contour that roughly estimated the liver shape. A geodesic active contour segmentation algorithm coupled with level-set contour evolution refined the initial contour to define the liver boundaries more precisely. The liver volume was then calculated using these refined boundaries. Hepatic CT scans of 15 prospective liver donors were obtained under a liver transplant protocol with a multidetector CT system. The liver volumes extracted by the computerized scheme were compared to those traced manually by a radiologist, used as ''gold standard.''Results: The mean liver volume obtained with our scheme was 1504 cc, whereas the mean gold standard manual volume was 1457 cc, resulting in a mean absolute difference of 105 cc (7.2%). The computer-estimated liver volumetrics agreed excellently with the gold-standard manual volumetrics (intraclass correlation coefficient was 0.95) with no statistically significant difference (F=0.77; p(F{<=}f)=0.32). The average accuracy, sensitivity, specificity, and percent volume error were 98.4%, 91.1%, 99.1%, and 7.2%, respectively. Computerized CT liver volumetry would require substantially less completion time (compared to an average of 39 min per case by manual segmentation). Conclusions: The computerized liver extraction scheme provides an efficient and accurate way of measuring liver volumes in CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-182: Investigation of Systems for Improved Accuracy in Clinical Y-90 Percent Delivered Calculations

Purpose: Y-90 Selective Internal Radiation Therapy (SIRT) is used to treat liver tumors, and by nature has variability in the percent of the intended dose that is actually delivered. To determine the quality of the administration, pre and post activity measurements are taken, and used to infer percent delivered. Vendor specifications indicate the use of an ion chamber to take these measurements. In our work, we investigated the accuracy of ion chambers, and compared them to other detector systems. Methods: We have built phantoms, phantom holders, and protocols, which allow us to measure our Y90 doses with varying apparatuses: a dose calibrator, a Geiger-counter, an ion chamber, a crystal based thyroid probe, and a gamma camera. We have set up a system that has enabled us to gather data by measuring clinical Y90 doses as they are used in the clinic using all of the instrumental methods. Five initial doses (25 measurements/acquisitions) have been taken at the time of this abstract submission. Results: Our initial results show that measurements acquired using scintillation based detectors (thyroid probe and gamma camera) correlate better with the gold standard (i.e. the dose calibrator). Pearson correlations between the dose calibrator measurements and the GM counter, Ion chamber, thyroid probe, and gamma camera were found to be 0.88, 0.83, 0.98, 0.99, respectively. More acquisitions and analysis are planned to determine the precision of the systems, as well as optimal energy window settings. Conclusion: It is likely that current standard practice can be improved using scintillation crystal based detectors. Such systems are more sensitive, can integrate signal, and can use energy discrimination. Furthermore, phantoms can be built to integrate with probe and gamma camera systems that are robust and provide reproducibility. Future work will include expanded acquisition and analysis.

60 APPLIED LIFE SCIENCES↗

Solid-phase Submonomer Synthesis of Peptoid Polymers and their Self-Assembly into Highly-Ordered Nanosheets

Peptoids are a novel class of biomimetic, non-natural, sequence-specific heteropolymers that resist proteolysis, exhibit potent biological activity, and fold into higher order nanostructures. Structurally similar to peptides, peptoids are poly N-substituted glycines, where the side chains are attached to the nitrogen rather than the alpha-carbon. Their ease of synthesis and structural diversity allows testing of basic design principles to drive de novo design and engineering of new biologically-active and nanostructured materials. Here, a simple manual peptoid synthesis protocol is presented that allows the synthesis of long chain polypeptoids ( up to 50mers) in excellent yields. Only basic equipment, simple techniques (e.g. liquid transfer, filtration), and commercially available reagents are required, making peptoids an accessible addition to many researchers' toolkits. The peptoid backbone is grown one monomer at a time via the submonomer method which consists of a two-step monomer addition cycle: acylation and displacement. First, bromoacetic acid activated in situ with N,N'- diisopropylcarbodiimide acylates a resin-bound secondary amine. Second, nucleophilic displacement of the bromide by a primary amine follows to introduce the side chain. The two-step cycle is iterated until the desired chain length is reached. The coupling efficiency of this two-step cycle routinely exceeds 98% and enables the synthesis of peptoids as long as 50 residues. Highly tunable, precise and chemically diverse sequences are achievable with the submonomer method as hundreds of readily available primary amines can be directly incorporated. Peptoids are emerging as a versatile biomimetic material for nanobioscience research because of their synthetic flexibility, robustness, and ordering at the atomic level. The folding of a single-chain, amphiphilic, information-rich polypeptoid into a highly-ordered nanosheet was recently demonstrated. This peptoid is a 36-mer that consists of only three different commercially available monomers: hydrophobic, cationic and anionic. The hydrophobic phenylethyl side chains are buried in the nanosheet core whereas the ionic amine and carboxyl side chains align on the hydrophilic faces. The peptoid nanosheets serve as a potential platform for membrane mimetics, protein mimetics, device fabrication, and sensors. Methods for peptoid synthesis, sheet formation, and microscopy imaging are described and provide a simple method to enable future peptoid nanosheet designs.

59 BASIC BIOLOGICAL SCIENCES↗

GenomeTrakr proficiency testing for foodborne pathogen surveillance: an exercise from 2015

Pathogen monitoring is becoming more precise as sequencing technologies become more affordable and accessible worldwide. This transition is especially apparent in the field of food safety, which has demonstrated how whole-genome sequencing (WGS) can be used on a global scale to protect public health. GenomeTrakr coordinates the WGS performed by public-health agencies and other partners by providing a public database with real-time cluster analysis for foodborne pathogen surveillance. Because WGS is being used to support enforcement decisions, it is essential to have confidence in the quality of the data being used and the downstream data analyses that guide these decisions. Routine proficiency tests, such as the one described here, have an important role in ensuring the validity of both data and procedures. In 2015, the GenomeTrakr proficiency test distributed eight isolates of common foodborne pathogens to participating laboratories, who were required to follow a specific protocol for performing WGS. Resulting sequence data were evaluated for several metrics, including proper labelling, sequence quality and new single nucleotide polymorphisms (SNPs). Illumina MiSeq sequence data collected for the same set of strains across 21 different laboratories exhibited high reproducibility, while revealing a narrow range of technical and biological variance. The numbers of SNPs reported for sequencing runs of the same isolates across multiple laboratories support the robustness of our cluster analysis pipeline in that each individual isolate cultured and resequenced multiple times in multiple places are all easily identifiable as originating from the same source.

59 BASIC BIOLOGICAL SCIENCES↗

The Feasibility of Moving PMU Data in the Future Power Grid

The power grid is a complex network connecting electricity providers with their consumers. With an increasing consumer base requiring more resources and the requirement to integrate significant renewable sources, maintaining the network requires new and innovative management solutions. To manage this complexity and provide precise, real-time views of the grid, Phasor Measurement Units (PMUs) are undergoing widespread deployment. These units provide measurements as often as 60 times per second, with an accurate time identifier attached to each reading, enabling real-time monitoring of the network. However, this new capability generates much more data than the current infrastructure is designed to handle. With the expectation that there will eventually be tens of thousands of PMUs monitoring the transmission lines, the power community is looking towards accumulating multiple terabytes of data per day - several orders of magnitude beyond current data acquisition rates. This has led to questions being raised in the power community about whether or not a significant research effort is required to effectively transfer the volume of information generated by these new data streams. This paper answers that question by comparing a worst-case data generation scenario with several alternative networking protocols and historical trends in protocol advancement. Based on this analysis we are able to conclude that transferring the information between the PMUs and the resulting data repositories is feasible. We recognize that there are issues beyond transferring the data that need to be addressed such as effective access to historical data, data transfer latency, cyber security, and data analysis. There is also an extensive engineering trade-off that the power companies will need to make to decide the best mix of networking protocols for their particular PMU deployments, since that requires significant assumptions about proprietary information including deployment cost, deployment schedules, PMU locations, and available resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dark Energy Survey Year 3 results: A 2.7% measurement of baryon acoustic oscillation distance scale at redshift 0.835

We present angular diameter measurements obtained by measuring the position of baryon acoustic oscillations (BAO) in an optimized sample of galaxies from the first three years of Dark Energy Survey data (DES Y3). The sample consists of 7 million galaxies distributed over a footprint of 4100 deg 2 with 0.6 < z photo < 1.1 and a typical redshift uncertainty of 0.03 ( 1 + z ) . The sample selection is the same as in the BAO measurement with the first year of DES data, but the analysis presented here uses three times the area, extends to higher redshift, and makes a number of improvements, including a fully analytical BAO template, the use of covariances from both theory and simulations, and an extensive preunblinding protocol. We used two different statistics; angular correlation function and power spectrum, and validate our pipeline with an ensemble of over 1500 realistic simulations. Both statistics yield compatible results. We combine the likelihoods derived from angular correlations and spherical harmonics to constrain the ratio of comoving angular diameter distance D M at the effective redshift of our sample to the sound horizon scale at the drag epoch. We obtain D M ( z eff = 0.835 ) / r d = 18.92 ± 0.51 , which is consistent with, but smaller than, the Planck prediction assuming flat Λ CDM , at the level of 2.3 σ . The analysis was performed blind and is robust to changes in a number of analysis choices. It represents the most precise BAO distance measurement from imaging data to date, and is competitive with the latest transverse ones from spectroscopic samples at z > 0.75 . When combined with DES 3 x 2 pt + SNIa , they lead to improvements in H 0 and Ω m constraints by ∼ 20 % .

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-J-203: Retrospective Assessment of Delivered Proton Dose in Prostate Cancer Patients Based On Daily In-Room CT Imaging

Purpose: Retrospective calculation of the delivered proton dose in prostate cancer patients based on a unique dataset of daily CT images. Methods: Inter-fractional motion in prostate cancer patients treated at our proton facility is counteracted by water-filled endorectal ballon and bladder filling protocol. Typical plans (XiO, Elekta Instruments AB, Stockholm) for 74 Gy(RBE) sequential boost treatment in 37 fractions include two series of opposing lateral double-scattered proton beams covering the respective iCTV. Stability of fiducial markers and anatomy were checked in 12 patients by daily scheduled in-room control CT (cCT) after immobilization and positioning according to bony anatomy utilizing orthogonal X-ray. In RayStation 4.6 (RaySearch Laboritories AB, Stockholm), all cCTs are delineated retrospectively and the treatment plans were recalculated on the planning CT and the registered cCTs. All fraction doses were accumulated on the planning CT after deformable registration. Parameters of delivered dose to iCTV (D98%>95%, D2%<107%), bladder (V75Gy<15%, V70Gy<25%, V65Gy<30%), rectum (V70Gy<10%, V50Gy<40%) and femoral heads (V50Gy<5%) are compared to those in the treatment plan. Intra-therapy variation is represented in DVH bands. Results: No alarming differences were observed between planned and retrospectively accumulated dose: iCTV constraints were met, except for one patient (D98%=94.6% in non-boosted iCTV). Considered bladder and femoral head values were below the limits. Rectum V70Gy was slightly exceeded (<11.3%) in two patients. First intra-therapy variability analysis in 4 patients showed no timedependent parameter drift, revealed strongest variability for bladder dose. In some fractions, iCTV coverage (D98%) and rectum V70Gy was missed. Conclusion: Double scattered proton plans are accurately delivered to prostate cancer patients due to fractionation effects and the applied precise positioning and immobilization protocols. As a result of rare interventions after daily 3D imaging of the first 12 patients, in-room CT frequency for prostate cancer patients was reduced. The presented study supports this decision. The authors acknowledge the German Federal Ministry for Education and Research for funding the High Precision Radiotherapy Group at the OncoRay - National Center for Radiation Research in Oncology (BMBF- 03Z1N51).

60 APPLIED LIFE SCIENCES↗

Rapid and high-throughput determination of sorghum ( Sorghum bicolor ) biomass composition using near infrared spectroscopy and chemometrics

Compositional characterization of biomass is vital for the biofuel industry. Traditional wet chemistry-based methods for analyzing biomass composition are laborious, time-consuming, and require extensive use of chemical reagents as well as highly skilled personnel. In this study, near-infrared (NIR) spectroscopy was used to quickly assess the composition of above-ground vegetative biomass from 113 diverse, photoperiod-sensitive, biomass-type sorghum (Sorghum bicolor) accessions cultivated under field conditions in Central Illinois. Biomass samples were analyzed using NIR spectra collected in the spectral range of 867–2536 nm, with their chemical compositions determined following the National Renewable Energy Laboratory (NREL) protocol. Advanced spectral pre-treatment and band selection techniques were utilized to develop calibration models using partial least squares regression (PLSR). The models’ effectiveness was assessed through cross-validation and independent data tests. The predictions for moisture, ash, extractives, glucan, xylan, acid-soluble lignin (ASL), acid-insoluble lignin (AIL), and total lignin were accurate and reliable, demonstrating the capability of NIR spectroscopy to provide rapid and precise characterization of sorghum biomass. The results demonstrated that NIR spectroscopy is an efficient tool for rapidly characterizing sorghum biomass, making it a sustainable option for screening desirable feedstock for biofuel or bioproduct production.

09 BIOMASS FUELS↗

Data for Rapid and High-Throughput Determination of Sorghum ( Sorghum bicolor ) Biomass Composition using Near Infrared Spectroscopy and Chemometrics

Compositional characterization of biomass is vital for the biofuel industry. Traditional wet chemistry-based methods for analyzing biomass composition are laborious, time-consuming, and require extensive use of chemical reagents as well as highly skilled personnel. In this study, near-infrared (NIR) spectroscopy was used to quickly assess the composition of above-ground vegetative biomass from 113 diverse, photoperiod-sensitive, biomass-type sorghum ( Sorghum bicolor ) accessions cultivated under field conditions in Central Illinois. Biomass samples were analyzed using NIR spectra collected in the spectral range of 867–2536 nm, with their chemical compositions determined following the National Renewable Energy Laboratory (NREL) protocol. Advanced spectral pre-treatment and band selection techniques were utilized to develop calibration models using partial least squares regression (PLSR). The models’ effectiveness was assessed through cross-validation and independent data tests. The predictions for moisture, ash, extractives, glucan, xylan, acid-soluble lignin (ASL), acid-insoluble lignin (AIL), and total lignin were accurate and reliable, demonstrating the capability of NIR spectroscopy to provide rapid and precise characterization of sorghum biomass. The results demonstrated that NIR spectroscopy is an efficient tool for rapidly characterizing sorghum biomass, making it a sustainable option for screening desirable feedstock for biofuel or bioproduct production.

Biomass Analytics↗