Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precision measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Applications of radio interferometry to navigation

Radio astronomy experiments have demonstrated the feasibility of making precise position measurements using interferometry techniques. The application of this method to navigation and marine geodesy is discussed, and comparisons are made with existing navigation systems. The very long baseline technique, with a master station, can use either an artificial satellite or natural sources as position references; a high-speed data link is required. A completely ship-borne system is shown to be feasible, at the cost of poorer sensitivity for natural sources. A comparison of Doppler, delay and phase-track modes of operating a very long baseline configuration is made, as that between instantaneous measurements and those where a source can be tracked from horizon to transit. Geometric limitations in latitude and longitude coverage are discussed. The characteristics of natural radio sources, their flux, distribution on the sky, and apparent size are shown to provide a limit on position measurements precision. The atmosphere and frequency standard used both contribute to position measurement uncertainty by affecting interferometric phase.

Knowles, S. H.↗

Portable aerosol-particle counter

Device makes real-time, precise measurements of aerosols of small particle size. Measurement combines laser velocimetry and light scattering. Technique offers advantages over currently practiced techniques: by measuring aerosol size in real-time, measuring size precisely, and having high sensitivity in size range of greatest biological concern.

Weber, F. N., Jr.↗

Introduction to Radiation Issues for International Space Station Extravehicular Activities

The International Space Station (ISS) provides significant challenges for radiation protection of the crew due to a combination of circumstances including: the extended duration of missions for many crewmembers, the exceptionally dynamic nature of the radiation environment in ISS orbit, and the necessity for numerous planned extravehicular activities (EVA) for station construction and maintenance. Radiation protection requires accurate radiation dose measurements and precise risk modeling of the transmission of high fluxes of energetic electrons and protons through the relatively thin shielding provided by the space suits worn during EVA. Experiments and analyses have been performed due to the necessity to assure complete radiation safety for the EVA crew and thereby ensure mission success. The detailed characterization described of the material and topological properties of the ISS space suits can be used as a basis for design of space suits used in future exploration missions. In radiation protection practices, risk from exposure to ionizing radiation is determined analytically by the level of exposure, the detrimental quality of the radiation field, the inherent radiosensitivity of the tissues or organs irradiated, and the age and gender of the person at the time of exposure. During low Earth orbit (LEO) EVA, the relatively high fluxes of low-energy electrons and protons lead to large variations in exposure of the skin, lens of the eye, and tissues in other shallow anatomical locations. The technical papers in this publication describe a number of ground-based experiments that precisely measure the thickness of the NASA extravehicular mobility unit (EMU) and Russian Zvezda Orlan-M suits using medical computerized tomography (CT) X-ray analysis, and particle accelerator experiments that measure the minimum kinetic energy required by electrons and photons to penetrate major components of the suits. These studies provide information necessary for improving the understanding of the current ISS space suits and provide insights into improved approaches for the design of future suits. This chapter begins with a summary of the dynamic ionizing radiation environment in LEO space and introduces the concepts and quantities used to quantify exposure to space radiation in LEO. The space suits used for EVA and the experimental partial human phantom are described. Subsequent chapters report results from measured charged particle fields before and after incident protons and secondary particles are transported through the space suits and into organs and tissues.

Shavers, M. R.↗

Thermophysical property measurements in electromagnetic levitators

Proper measurements of thermophysical properties of hot levitated liquid drops require the following: accurate temperature measurement (brightness measurement, emissivity measurement); precise drop shape measurements with submillisecond time resolution (density determination, rotational and vibrational shape information); precise control of drop shape (high symmetry variable gap levitators); accurate energy transfer measurements (direct measurements of energy transfer rates for defined gas flows over samples with quantitative measurements of energy transfer rates for defined flows over samples with known shapes); and precise measurements of repetitive sample motions (rapid repetitive shape measurements, frequency measurements with reflected laser light, measurements in the levitator and as a freely falling drop). Recent advances in coil design and control of sample rotation in an electromagnetic levitator are discussed with respect to the above requirements.

Hauge, Robert H.↗

Machine Vision for High Precision Volume Measurement Applied to Levitated Containerless Materials Processing

By combining the best practices in optical dilatometry with new numerical methods, a high-speed and high precision technique has been developed to measure volume of levitated, containerlessly processed samples with sub- pixel resolution. Containerless processing provides the ability to study highly reactive materials without the possibility of contamination affecting thermo-physical properties. Levitation is a common technique used to isolate a sample as it is being processed. Noncontact optical measurement of thermo-ophysical properties is very important as traditional measuring methods cannot be used. Modern, digitally recorded images require advanced numerical routines to recover the sub-pixel locations of sample edges and, in turn produce high precision measurements.

Bradshaw, R. C.↗

Analysis of Active Lava Flows on Kilauea Volcano, Hawaii, Using SIR-C Radar Correlation Measurements

Precise eruption rates of active pahoehoe lava flows on Kilauea volcano, Hawaii, have been determined using spaceborne radar data acquired by the Space Shuttle Imaging Radar-C (SIR-C). Measurement of the rate of lava flow advance, and the determination of the volume of new material erupted in a given period of time, are among the most important observations that can be made when studying a volcano.

volcano lava flow Kilauea spaceborne radar SIR-C↗

Non-Contact EDDY Current Hole Eccentricity and Diameter Measurement

Precision holes are among the most critical features of a mechanical component. Deviations from permissible tolerances can impede operation and result in unexpected failure. We have developed an automated non-contact eddy current hole diameter and eccentricity measuring system. The operating principle is based on the eddy current lift-off effect, which is the coil impedance as a function of the distance between the coil and the test object. An absolute eddy current probe rotates in the hole. The impedance of each angular position is acquired and input to the computer for integration and analysis. The eccentricity of the hole is the profile of the impedance as a function of angular position as compared to a straight line, an ideal hole. The diameter of the hole is the sum of the diameter of the probe and twice the distance-calibrated impedance. An eddy current image is generated by integrating angular scans for a plurality of depths between the top and bottom to display the eccentricity profile. This system can also detect and image defects in the hole. The method for non-contact eddy current hole diameter and eccentricity measurement has been granted a patent by the U.S. Patent and Trademark Office.

Chern, E. James↗

Precision insolation measurement under field conditions

The paper describes a precision insolation instrument - the Mark 3 Kendall Radiometer - developed for field survey work and for use as a calibration transfer standard. The instrument, which can be used to make accurate measurements of solar irradiance, has a windowless black cavity receptor mounted in a massive heat sink and has equal sensitivity to ultraviolet, infrared, and visible radiation. Attention is given to a calibration stability analysis over two years of operation.

Reid, M. S.↗

Value of Sample Return and High Precision Analyses: Need for A Resource of Compelling Stories, Metaphors and Examples for Public Speakers

There is widespread agreement among planetary scientists that much of what we know about the workings of the solar system comes from accurate, high precision measurements on returned samples. Precision is a function of the number of atoms the instrumentation is able to count. Accuracy depends on the calibration or standardization technique. For Genesis, the solar wind sample return mission, acquiring enough atoms to ensure precise SW measurements and then accurately quantifying those measurements were steps known to be non‐trivial pre‐flight. The difficulty of precise and accurate measurements on returned samples, and why they cannot be made remotely, is not communicated well to the public. In part, this is be-cause "high precision" is abstract and error bars are not very exciting topics. This paper explores ideas for collecting and compiling compelling metaphors and colorful examples as a resource for planetary science public speakers.

Allton, J. H.↗

Thermal-Expansion Measurement

Precise stable laser system determines coefficients of thermal expansion. Dual-beam interferometer arrangement monitors changes in sample length as function of temperature by following changes inoptical path lengths.

Davis, J. H.↗

Improved rocket ozonesonde (ROCOZ-A). I - Demonstration of precision

Measurements of the daytime ozone distribution in the stratosphere have been made with an improved rocket ozonesonde (ROCOZ-A). Vertical cumulative ozone as a function of geometric altitude is the basic information content of these measurements. The instrument-to-instrument repeatability of the ozonesonde was determined by two series of four soundings each. At one standard deviation the instrument repeatability averages from 2.0 to 2.5 percent over the entire altitude range of the instrument. The worst measured repeatability is 3.7 percent at 55 km for one of the flight series.

Holland, A. C.↗

An evaluation of water vapor radiometer data for calibration of the wet path delay in very long baseline interferometry experiments

The internal consistency of the baseline-length measurements derived from analysis of several independent VLBI experiments is an estimate of the measurement precision. The paper investigates whether the inclusion of water vapor radiometer (WVR) data as an absolute calibration of the propagation delay due to water vapor improves the precision of VLBI baseline-length measurements. The paper analyzes 28 International Radio Interferometric Surveying runs between June 1988 and January 1989; WVR measurements were made during each session. The addition of WVR data decreased the scatter of the length measurements of the baselines by 5-10 percent. The observed reduction in the scatter of the baseline lengths is less than what is expected from the behavior of the formal errors, which suggest that the baseline-length measurement precision should improve 10-20 percent if WVR data are included in the analysis. The discrepancy between the formal errors and the baseline-length results can be explained as the consequence of systematic errors in the dry-mapping function parameters, instrumental biases in the WVR and the barometer, or both.

Kuehn, C. E.↗

Assessment of GOES-16/ABI middle wave infrared band using references of Himawari-8/AHI and Aqua/MODIS

GOES-16 is the first of the GOES-R series of Geostationary Operational Environmental Satellites (GOES) and was launched on November 19, 2016. The spacecraft was initially in a test position of 89.5° West and reached its operational position (75.2° West) on December 11, 2017. The Himawari-8 spacecraft was launched on October 7, 2014 and is located at 140.7º East. The similar design and similar calibration algorithm between the Advanced Baseline Imager (ABI) on-board GOES-16 and the Advanced Himawari Imager (AHI) on board Himawari-8 makes the importance of inter-comparison. Due to their locations, double difference is an appropriate method for their comparison and Aqua MODIS is one of good references. However, ABI (AHI) midwave-infrared (MWIR) band 7 does not have good matching with Aqua MODIS. In this work, the ABI-AHI comparison and ABI assessment for MWIR band 7 is performed using Aqua bands 20, 22, and 23. The ocean sites under ABI (AHI) at nadir are used for inter-comparison with Aqua MODIS. To enhance the comparison accuracy, a few procedures and corrections have been applied. For MWIR band 7, the ABI-AHI difference is about -0.39K over ocean scene, with the ABI measurement precision being slightly better than that of AHI. This double difference method is also being used for the assessment of ABI consistency before and after re-location on November 30, 2017. Two ocean scenes are selected for the ABI re-location assessments, with measurement precision at nadir providing better measurements than non-zero view angles. The ABI MWIR measurement over the ocean scene at the same view angle before and after re-location shows that the precisions are comparable. The MWIR band brightness temperature (BT) measurement over ocean scene shows a 0.04K difference, while the measurement precision before and after re-location is consistent.

Inter-comparison↗