Search NASA⌕ Search

SEARCH · Search NASA

Results for “Proficiency testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

92 records · Page 6

Integrating Sudo-Kaminaga Correlation to the Safety Analysis Code PARET-ANL

The accuracy and reliability of the reactor safety analysis code are critical because the specifications of the safety systems will depend on the analytical results for initiating events that could occur to the reactor. In safety analyses for power reactors, there exist many proficient and applicable computer codes such as RELAP5, CATHARE, RETRAN, or CATHENA. For non-power research reactors, an issue arises, however, due to lacking of such specialized codes. As a result, computer codes developed for the transient analysis of power reactors need to be applied carefully after proving their applicability to a specified research reactor. The safety analysis discussed in this paper concerns the prevention of fuel damage in hypothetical accidental scenarios for the new research reactor design at National Institute of Standards and Technology (NIST). One fuel integrity criterion is analyzed by investigating the Minimum Critical Heat Flux Ratio (MCHFR) in the core during the accidental transients. Some previous studies develop a relationship that correlates the nominal value of the minimum CHFR with the probability of CHF occurring and causing fuel damage. Using a statistical approach, the nominal value of the MCHFR for the low-enriched uranium (LEU) reactor needs to remain above the recommended limiting value to better ensure the safety of the research reactor. The probability of no fuel failure increases as the MCHFR increases. More importantly, as long as the MCHFR remains above the recommended limiting value of 1.301, the reactor will have a 90% probability that CHF is not reached. The safety analysis program PARET, developed by Argonne National Laboratory (ANL), is employed to obtain the CHFR information in this study. PARET/ANL is a digital computer programming code intended primarily for the analysis of test and research reactors that use plate-type (flat) fuel elements. This program has its own set of correlations that are used to calculate the CHFR. One of them is the Mirshak correlation, which was believed to provide the best estimation of the critical heat flux under the operating conditions of the new reactor at the time. Following the critical heat flux (CHF) experiments for vertical rectangular channels in the JRR-3 (Japan Research Reactor unit 3), the CHF calculations now use the Sudo- Kaminaga correlation. This correlation is of our interest because this method has an enhanced geometric similarity and an increased range of applicability that are more representative of the actual operating conditions of our current design, and has a more mechanistic approach [9]. Since the source code of PARET/ANL is inaccessible, a MATLAB-based utility has been written to integrate the Sudo-Kaminaga correlation as a substitute for the Mirshak correlation in the code. As a result, both the Mirshak and the Sudo-Kaminaga correlations are used to analyze the standard output from the PARET program to calculate the CHFR.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-J-210: Characterizing Tissue Equivalent Materials for the Development of a Dual MRI-CT Heterogeneous Anthropomorphic Phantom Designed Specifically for MRI Guided Radiotherapy Systems

Purpose: MRI guided radiotherapy (MRIgRT) is an emerging technology which will eventually require a proficient quality auditing system. Due to different principles in which MR and CT acquire images, there is a need for a multi-imaging-modality, end-to-end QA phantom for MRIgRT. The purpose of this study is to identify lung, soft tissue, and tumor equivalent substitutes that share similar human-like CT and MR properties (i.e. Hounsfield units and relaxation times). Methods: Materials of interested such as common CT QA phantom materials, and other proprietary gels/silicones from Polytek, SmoothOn, and CompositeOne were first scanned on a GE 1.5T Signa HDxT MR. Materials that could be seen on both T1-weighted and T2-weighted images were then scanned on a GE Lightspeed RT16 CT simulator and a GE Discovery 750HD CT scanner and their HU values were then measured. The materials with matching HU values of lung (−500 to −700HU), muscle (+40HU) and soft tissue (+100 to +300HU) were further scanned on GE 1.5T Signa HDx to measure their T1 and T2 relaxation times from varying parameters of TI and TE. Results: Materials that could be visualized on T1-weighted and T2-weighted images from a 1.5T MR unit and had an appropriate average CT number, −650, −685, 46,169, and 168 HUs were: compressed cork saturated with water, Polytek Platsil™ Gel-00 combined with mini styrofoam balls, radiotherapy bolus material, SmoothOn Dragon-Skin™ and SmoothOn Ecoflex™, respectively. Conclusion: Post processing analysis is currently being performed to accurately map T1 and T2 values for each material tested. From previous MR visualization and CT examinations it is expected that Dragon-Skin™, Ecoflex™ and bolus will have values consistent with tissue and tumor substitutes. We also expect compressed cork statured with water, and Polytek™-styrofoam combination to have approximate T1 and T2 values suitable for lung-equivalent materials.

60 APPLIED LIFE SCIENCES↗