Search NASA⌕ Search

SEARCH · Search NASA

Results for “Proton facilities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Proton beam enhancements from ultrafast laser interactions with compound parabolic concentrators

Target normal sheath acceleration (TNSA) is among the most widely studied laser–plasma ion acceleration mechanisms. In this Letter, we report on studies of proton acceleration from flat Cu targets with cone-like focusing structures called compound parabolic concentrators (CPCs) coupled to their front surface. The CPC acts as a non-imaging focusing optic that enhances the laser intensity at the target's front surface by ∼2×, from 9 × 10 18 to 2 × 10 19 W/cm 2 . This effect drives a reduction in the particle source size from the typical laser spot size of 120 μm to the CPC tip size of 65 μm and significant enhancements in the peak energy and temperature (2.6 × increase) of the resulting TNSA proton beam. We also observe increased opening angle of the beam. 2D PIC simulations have been conducted and replicate the experimental behavior. These increases have implications for long focal length facilities that require higher energy proton beams, which now can be achieved without significant infrastructure changes.

3D printing↗

Impact parameter dependence of color charge correlations in the proton

The impact parameter dependence of color charge correlators in the proton is obtained from the light front formalism in light cone gauge. We include NLO corrections due to the |qqqg\rangle | q q q g ⟩ Fock state via light-cone perturbation theory. Near the center of the proton, the b b -dependence of the correlations is very different from a ``transverse profile function’’. The resulting t t -dependence of exclusive J/\Psi J / Ψ photoproduction transitions from exponential to power law at |t| \approx 1 | t | ≈ 1 ~GeV ^2 2 . This prediction could be tested at upcoming DIS facilities or in nucleus-proton ultraperipheral collisions (UPCs).

Dumitru, Adrian↗

Proton branching ratios of 23 Mg levels

Background: The anomalous 22 Ne abundance measured in certain presolar graphite grains is thought to arise from the decay of 22 Na that was synthesized at high temperatures in core-collapse supernovae. To better interpret this abundance anomaly, the primary destruction mechanism of 22 Na, the 22 Na(p,γ) 23 Mg reaction, must be better understood. Purpose: Determine proton branching ratios of several 23 Mg excited states that play a role in the high-temperature 22 Na(p,γ) 23 Mg reaction rate. Methods: Particle decays of 23 Mg excited states populated with the previously reported 24 Mg(p,d) 23 Mg transfer reaction measurement [Kwag et al., Eur. Phys. J. A 56, 108 (2020)] were analyzed to extract proton branching ratios. The reaction was studied using a 31-MeV proton beam from the Holifield Radioactive Ion Beam Facility of Oak Ridge National Laboratory and 24 Mg solid targets. Results: Proton branching ratios of several 23 Mg excited states in the energy range of Ex = 8.044 - 9.642 MeV were experimentally determined for the first time for the p0 and p1'(p1+p2+p3) decay channels. Conclusions: These new branching ratios for 23 Mg levels can provide an experimental foundation for an improved high-temperature rate of the 22 Na(p,γ) 23 Mg reaction needed to understand production of anomalously high 22 Ne abundance in core-collapse supernovae.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Establishing Pb-203 production from electrodeposited Tl targets at Brookhaven National Laboratory

Background: Promising developments in Pb-212 radiopharmaceutical therapies have increased demand for Pb-203 diagnostic agents. Building on previous work from various isotope production facilities, this study optimized Pb-203 production from electrodeposited Tl targets at Brookhaven National Laboratory (BNL). The additional supply of Pb-203 may help meet growing preclinical and clinical demands. Results: Two Tl targets were irradiated at the Brookhaven Linac Isotope Producer facility with 30 ± 1 MeV protons, measured using previously published cross section data. Distribution coefficients for Pb Resin in acetate media were investigated for both Na + and K + cations, where potassium acetate was ~ 4 times more effective at stripping Pb from the Pb Resin. The Tl electrodeposition was optimized to deposit 350 mg of Tl (~ 60 mg/cm 2 ) on Au backing in under 6 h. The proposed separation process was completed in < 1.5 h and achieved > 98% and 92 ± 3% recovery of Tl and Pb, respectively, with an overall Tl-Pb separation factor of 6 × 10 5 . The experimentally measured half-life of Pb-203 was 52.4 ± 0.7 h, agreeing with 51.93 ± 0.02 h reported by the National Nuclear Data Center. The radioisotopic purity of the Pb fraction at 24 h post end of bombardment (EOB) from a 24 h irradiation was 66% Pb-203, 28% Pb-201, and 6% Pb-200. Following chemical separation, the Pb-203 produced in this work (21 MBq Pb-203 EOB) achieved apparent molar activities of 10 ± 5 and 0.9 ± 0.5 GBq/µmol for [ 203 Pb]Pb-DOTAM and [ 203 Pb]Pb-DO3A, respectively, decay corrected to EOB. Data derived from this work suggests BNL can produce > 10’s GBq Pb-203 with > 99% radiochemical and radioisotopic purity from Tl-205 for worldwide distribution. Conclusions: The production and separation of Pb-203 from natural Tl target material was successfully demonstrated at BNL. Existing methods were adapted and optimized for the facilities at BNL. Results from this work will guide future large-scale Pb-203 production opportunities at BNL for clinical applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Resistive AC-Coupled Silicon Detectors: principles of operation and first results from a combined analysis of beam test and laser data

This paper presents the principles of operation of Resistive AC-Coupled Silicon Detectors (RSDs) and measurements of the temporal and spatial resolutions using a combined analysis of laser and beam test data. RSDs are a new type of n-in-p silicon sensor based on the Low-Gain Avalanche Diode (LGAD) technology, where the n+ implant has been designed to be resistive, and the read-out is obtained via AC-coupling. The truly innovative feature of RSD is that the signal generated by an impinging particle is shared isotropically among multiple read-out pads without the need for floating electrodes or an external magnetic field. Careful tuning of the coupling oxide thickness and the n+ doping profile is at the basis of the successful functioning of this device. Several RSD matrices with different pad width-pitch geometries have been extensively tested with a laser setup in the Laboratory for Innovative Silicon Sensors in Torino, while a smaller set of devices have been tested at the Fermilab Test Beam Facility with a 120 GeV/c proton beam. The measured spatial resolution ranges between 2.5μm for 70–100 pad-pitch geometry and 17μm with 200–500 matrices, a factor of 10 better than what is achievable in binary read-out (bin size/12). Beam test data show a temporal resolution of ~40ps for 200 μm pitch devices, in line with the best performances of LGAD sensors at the same gain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a platform for the gas transport, collection, and identification of fission products in the high-intensity laser environment

Recent progress in the production of laser accelerated high flux proton beams opens new possibilities for the study of fission in unique environments. To this end, we are currently pursuing the development of a platform for the swift gas transport, collection, and identification of fission products. Fission is induced in targets fixed inside a sealed chamber through which a carrier gas flows, transporting fission products to a carbon filter for collection and online spectroscopy. This has been recently demonstrated using target normal sheath accelerated protons at the PHELIX laser facility. There were large discrepancies between measured rates and those expected based on established fission yields and measured beam parameters. These discrepancies prompted a large number of tests at the Idaho Accelerator Center (IAC), where fission in uranium is induced by bremsstrahlung photons generated by 21 MeV electrons from a linear electron accelerator. Here, the results are compared to a series of models that account for the slowing of energetic fission fragments in the carrier gas and the fluid dynamics of the gas flow that transports fission products to the collection filter. Characterization of the apparatus reveals a few mechanisms that together account for a portion of the previously observed discrepancies at the PHELIX laser facility. However, additional research is necessary before high-accuracy experiments can be performed with the apparatus. Work performed under the auspices of the U.S. Department of Energy by LLNL under contract DE-AC52-07NA27344.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Signature of 0 + excited state and shape coexistence in 94 Kr through 93 Kr(d,p) 94 Kr reaction

A measurement of the excitation spectrum of 94 Kr via one-neutron transfer to the ground state of 93 Kr using the 93 Kr(d,p) 94 Kr reaction at 8A MeV, observing the outgoing protons, performed with the IRIS facility at TRIUMF is reported. Two states in 94 Kr, at 1.50±0.14 MeV and 2.20±0.14 MeV, were observed. An adiabatic-wave approximation analysis of the differential cross sections leads us to identify the lower energy state as being populated with neutron transfer to the 3 s1/2 orbital. This leads to the first observation of the lowest 0 + excited state in 94 Kr, hence signaling shape co-existence. Theoretical calculations performed within the in-medium similarity renormalization group framework are presented that also show the existence of a low-energy 0 + state, aligning qualitatively with the observation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Beam test performance of a prototype module with Short Strip ASICs for the CMS HL-LHC tracker upgrade

The Short Strip ASIC (SSA) is one of the four front-end chips designed for the upgrade of the CMS Outer Tracker for the High Luminosity LHC. Together with the Macro-Pixel ASIC (MPA) it will instrument modules containing a strip and a macro-pixel sensor stacked on top of each other. The SSA provides both full readout of the strip hit information when triggered, and, together with the MPA, correlated clusters called stubs from the two sensors for use by the CMS Level-1 (L1) trigger system. Results from the first prototype module consisting of a sensor and two SSA chips are presented. The prototype module has been characterized at the Fermilab Test Beam Facility using a 120 GeV proton beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resolution of a discrepancy in the γ-ray emission probability from the β decay of 137 Ce g

We have deduced the emission probability of the 447-keV γ ray from the ε + β + decay of Ce g 137 (9.0 h) relative to that of the 254-keV γ ray from the Ce m 137 (34.4 h) decay in transient equilibrium. The time-dependent factor in transient equilibrium was applied following the Bateman equation for a radioactive decay chain. The isotope was produced via the La 139 ( p , 3 n ) Ce m , g 137 reaction by bombarding nat La with a proton beam from the 88-in. cyclotron at Lawrence Berkeley National Laboratory. γ -ray intensities were measured using an HPGe detector. The emission probability for the 447-keV γ ray deduced in this work is 1.21(3) (that is 1.21 ± 0.03) per hundred parent decays, which differs significantly from an earlier published value of 2.24(10). We identify the source of this discrepancy to be an incorrect use of the time-dependent factor. Additionally, we have deduced the emission probability of the 504-keV γ ray from the decay of Y g 85 (2.68 h) relative to that of the 232-keV γ ray from the Sr m 85 (1.127 h) decay in transient equilibrium. The isotope was produced via the Sr 86 ( p , 2 n ) Y g 85 reaction by bombarding SrCO 3 86 with a proton beam at the same facility. Overall, the study confirms the assumption of the time-dependent correction for recommending the emission probability of the 504-keV γ ray in the literature. Our work highlights the importance of explicit description by authors of any time-dependent correction they have made when reporting γ -ray intensities for nuclides in transient equilibrium. The need and significance of accurate and precise decay data of Ce g 137 and Y g 85 in basic science and medicine is briefly outlined.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cellular and molecular analysis of mutagenesis induced by charged particles of defined linear energy transfer

Mutation induction by charged particles of defined linear energy transfer (LET) and gamma rays was scored using human-hamster hybrid AL cells. The LET values for charged particles accelerated at the Radiological Research Accelerator Facility ranged from 10 keV/microm protons to 150 keV/microm 4He ions. The induced mutant fractions at both the S1 and HGPRT loci were dependent on the dose and LET. In addition, for each dose examined, the mutant yield at the S1 locus was 30-60 fold higher than at the corresponding HGPRT locus. To determine whether the mutation spectrum was comparably dependent on dose and LET, independent S1- and HGPRT- mutants induced by 150 keV/microm 4He ions and gamma rays were isolated, and their DNA was analyzed by both Southern blotting and multiplex PCR methods. While the majority of radiation-induced mutants showed deletions of varying sizes, the relative percentage of large deletions was found to be related to both the dose and LET of the radiation examined. Using a mutation system that can detect multilocus changes, results of the present study show that radiation-induced chromosomal loss can be in the millions of base pairs.

NASA Discipline Radiation Health↗

Monte-Carlo Simulations of Heavy Ions Track Structures and Applications

In space, astronauts are exposed to protons, high ]energy heavy (HZE) ions that have a high charge (Z) and energy (E), and secondary radiation, including neutrons and recoil nuclei produced by nuclear reactions in spacecraft walls or in tissue. The astronauts can only be partly shielded from these particles. Therefore, on travelling to Mars, it is estimated that every cell nucleus in an astronaut fs body would be hit by a proton or secondary electron (e.g., electrons of the target atoms ionized by the HZE ion) every few days and by an HZE ion about once a month. The risks related to these heavy ions are not well known and of concern for long duration space exploration missions. Medical ion therapy is another situation where human beings can be irradiated by heavy ions, usually to treat cancer. Heavy ions have a peculiar track structure characterized by high levels of energy ]deposition clustering, especially in near the track ends in the so ]called eBragg peak f region. In radiotherapy, these features of heavy ions can provide an improved dose conformation with respect to photons, also considering that the relative biological effectiveness (RBE) of therapeutic ions in the plateau region before the peak is sufficiently low. Therefore, several proton and carbon ion therapy facilities are under construction at this moment

Plante, Ianik↗

Effects of Proton Irradiation on the Performance of Skipper CCDs

Skipper CCDs are a mature detector technology that has been suggested for future space telescope instruments requiring sub-electron readout noise in the near-ultraviolet to the near-infrared. While modern skipper CCDs inherit from the radiation-tolerant p-channel detectors developed by LBNL, the effects of high doses of ionizing radiation on skipper CCDs (such as those expected in space) remains largely unmeasured. We report preliminary results on the performance of p-channel skipper CCDs following irradiation with 217-MeV protons at the Northwestern Medicine Proton Center. The total nonionizing energy loss (NIEL) experienced by the detectors exceeds 6 years at the Sun-Earth Lagrange Point 2 (L2). We demonstrate that the skipper amplifier continues to function as expected following this irradiation. Owing to the low readout noise of these detectors, controlled irradiation tests can be used to sensitively characterize the charge transfer inefficiency, dark current, and the density and time constants of charge traps as a function of proton fluence. We conclude with a brief outlook toward future tests of these detectors at other proton and gamma-ray facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LINAC Longitudinal Simulation and Measurement of Output Energy

The Linac at Fermilab, one of the oldest accelerators on-site, plays a crucial role in delivering 400 MeV proton beams to other accelerating facilities. The beam traveling through Linac needs to be carefully monitored for better accelerator operation. One of the key factors of efficient Linac operation is its longitudinal stability. The stability can minimize Linac loss and maximize beam current. For this purpose, I examined the beam's longitudinal profile, which is crucial for proper beam transfer between its two sections. After careful monitoring of the beam through Linac, we need to ensure that it leaves with desired parameters. The beam coming out from the Linac is subsequently injected into the Booster, a synchrotron that relies on dipole magnets to bend the beam at injection. If the output energy of the beam deviates from the expected value, the beam will bend at an incorrect radius, leading to potential beam loss. Therefore, precise regulation of the output energy is critical for the efficient operation of the accelerator. To address this, I have conducted a thorough examination of the Linac longitudinal simulations and data from Beam Position Monitors (BPMs). My objective is to measure and stabilize the output energy and verify its correspondence with the predicted simulation results. All these analyses are important for efficient operation of the accelerator.

Safaryan, Milena↗

Impact of front-end parameters of the ARCADIA MD3 on charged particle detection

The ARCADIA INFN R&D project developed a Fully Depleted Monolithic Active Pixel Sensor (FD-MAPS) using a customized LFoundry 110 nm CIS process. The first in-beam characterization of the ARCADIA Main Demonstrator 3 (MD3) sensor with 200 $μ$m active thickness has been performed at the Fermilab Test Beam Facility with a 120 GeV proton beam. The Device Under Test (DUT) is tested with a trigger-less telescope composed of two ARCADIA MD3 tracking planes. This early study investigates the effect of the front-end parameters on the tracking performance.

Pantouvakis, C. [Padua U.; INFN, Padua]↗

Proposed muon collider R&D at SNS

Generation of a muon beam at a Muon Collider requires relatively short, high-charge proton bunches. They are produced in a high-average-power proton driver by first accumulating a proton beam from a super-conducting linac, then bunching the beam and finally compressing and combining the bunches into a single high-intensity proton pulse. All of these beam formation stages involve handling of unprecedentedly high beam charges. Validation of these intricate beam manipulations requires better understanding of extreme space-charge effects and experimental demonstration. A facility perhaps most closely resembling the proton driver configuration and beam parameters is the Spallation Neutron Source (SNS) accelerator complex at Oak Ridge National Laboratory (ORNL). Considering the energy scaling of the space-charge parameters, many of the beam formation steps planned for the proton driver can be experimentally checked at the SNS at the relevant space-charge interaction levels. This paper discusses potential proton driver and other muon-collider-related R\&D at the SNS.

43 PARTICLE ACCELERATORS↗

First measurement of proton decay from a transfer reaction to 21 Na

Decay protons from excited states in Na 21 populated through a previously reported Mg 24 ( p , α ) Na 21 transfer reaction [Cha et al. , Phys. Rev. C 96 , 025810 (2017) ] were analyzed to extract the proton branching ratios of the energy levels. Additionally, by utilizing 31-MeV proton beams from the Holifield Radioactive Ion Beam Facility of Oak Ridge National Laboratory and isotopically enriched Mg 24 solid targets, the decay protons were detected in coincidence with α particles from the ( p , α ) reaction using a silicon strip detector array. Proton decay branching ratios of several Na 21 levels were deduced for the p 0 and p 1 decay channels to the ground and first excited states in Ne 20 , respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗