Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pulse shape discrimination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Characterization of a silicon photo-multiplier array with summing board as a photo-multiplier tube replacement in organic scintillator assemblies

In this work, we report on the energy, timing, and pulse-shape discrimination performance of cylindrical 5.08 cm diameter x 5.08 cm thick and 7.62 cm diameter x 7.62 cm thick trans-stilbene crystals read out with the passively summed output of three different commercial silicon photo-multiplier arrays. Our results indicate that using the summed output of an 8 x 8 array of SiPMs provides performance competitive with photo-multiplier tubes for many neutron imaging and correlated particle measurements. For a 5.08 cm diameter x 5.08 cm thick crystal read out with SensL’s ArrayJ-60035_64P-PCB, which had the best overall properties, we measure the energy resolution as 17.8 ± 0.8% at 341 keVee (σ/E), the timing resolution in the 180–400 keVee range as 236 ± 61 ps (σ), and the pulse-shape discrimination figure-of-merit as 2.21 ± 0.03 in the 230–260 keVee energy range. For a 7.62 cm diameter x 7.62 cm thick crystal read out with SensL’s ArrayJ-60035_64P-PCB, we measure the energy resolution as 21.9 ± 2.3% at 341 keVee, the timing resolution in the 180–400 keVee range as 518 ± 42 ps, and the pulse-shape discrimination figure-of-merit as 1.49 ± 0.01 in the 230–260 keVee energy range. Our findings enable many scintillator-based instruments to enjoy the size, robustness, and power benefits of silicon photo-multiplier arrays as replacement for the photo-multiplier tubes that are predominantly used today.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deuterated Liquid Scintillators: A New Tool for Neutron Measurements

The response of large (4x6) deuterated liquid scintillators (up to 10 cm diameter by 15 cm) to neutrons in the energy range from 0.5 MeV to 20 MeV has been studied using several nuclear reactions, including d(d,n), and {sup 12}C(d,n){sup 13}N, at the University of Notre Dame FN tandem accelerator. The latter two reactions utilized 9 MeV and 16 MeV deuteron beams, including a pulsed beam that also permitted time-of-flight (ToF) measurements. Combining pulse-shape discrimination and (ToF) allows gating on specific neutron energy groups to determine the detector response to specific neutron energies. Newly-obtained and optimized pulse shape discrimination using digitized pulse analysis from these detectors will be presented in this paper. These measurements confirmed the ability of these detectors to provide useful neutron spectra without ToF.

43 PARTICLE ACCELERATORS↗

Mixed Material Scintillator Systems for Neutron Detection

Scintillators are a fundamental technology that enables radiation detection. Their use has historically enabled the detection of incoming gamma radiation, with recent advances in plastic scintillator development enabling detection and discrimination of neutron and gamma radiation through pulse shape discrimination. However, scintillators have so far consisted of a single material, typically one primary dye and one secondary dye embedded in a plastic matrix. Based on the simulation studies described previously, mixed material scintillator systems with multiple secondary dyes arranged in alternating, periodic micro-sized regions opens the door for scintillators with a wide variety of different capability, such as directional sensing, positional reconstruction, particle identification, and pulse shape discrimination. However, fabrication of a mixed material scintillator system by conventional manufacturing methods is difficult to manufacture and scale, creating a barrier to their wide spread implementation. On the other hand, additive manufacturing additive manufacturing presents itself as the optimal method for fabricating mixed material scintillator systems based on its flexibility, ability to fabricate fine features, and potential for multimaterial fabrication.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of high purity germanium point contact detectors with low net impurity concentration

High Purity germanium point-contact detectors have low energy thresholds and excellent energy resolution over a wide energy range, and are thus widely used in nuclear and particle physics. In rare event searches, such as neutrinoless double beta decay, the point-contact geometry is of particular importance since it allows for pulse-shape discrimination, and therefore for a significant background reduction. In this paper we investigate the pulse-shape discrimination performance of ultra-high purity germanium point contact detectors. It is demonstrated that a minimal net impurity concentration is required to meet the pulse-shape performance requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, 39Ar, a ß emitter of cosmogenic origin. For large detectors, the atmospheric 39Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of 39Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of 39Ar with respect to AAr by a factor larger than 1400. Assessing the 39Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly ?-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.

Noble liquid detectors, Dark Matter detectors, Cry↗

Gaussian mixture models as automated particle classifiers for fast neutron detectors

Pulse shape discrimination (PSD) is the task of classifying electronic pulse shapes for different particle types such as gamma rays and fast neutrons interacting in scintillators and read out by photo sensitive detectors. This field has been limited in its adoption of techniques found in the statistical learning community. Methods initially employed in the 1960s for analog electronic circuitry persist in the current PSD literature describing operations performed on digitized pulses, which are amenable to statistical rigor. Despite vast amounts of data collected at low energy levels, traditional PSD methods are unable to discriminate particles below a certain threshold. As such, in this work, Gaussian mixture models (GMMs) are used as a clustering technique for fast neutron detection in the absence of labeled data. GMMs yield improvements spanning the energy spectrum in a desirably efficient, unsupervised fashion. An extension, the Dirichlet Process GMM, provides further flexibility and classification improvement.

97 MATHEMATICS AND COMPUTING↗

Development of new Polysiloxane Based Liquid Scintillators

In the last decade, attention toward neutron detection has been growing in the scientific community, driven by new requirements in different fields of application ranging from homeland security to medical and material analysis, from research physics, to nuclear energy production. So far neutron detection, with particular attention to fast neutrons, has been mainly based on organic liquid scintillators, owing to their good efficiency and pulse shape discrimination (PSD) capability. Most of these liquids have however some main drawbacks given by toxicity, flammability, volatility and sensitivity to dissolved oxygen that limits the duration and the quality of their performances with worse handiness and increased costs. Phenyl-substituted polysiloxanes could address most of these issues, being characterized by low toxicity, low volatility and low flammability. Their optical properties can be tailored by changing the phenyl distribution and concentration thus allowing to increase the solubility of organic dyes, to modify the fluorescence spectra and to vary the refractive index of the medium. Furthermore, polysiloxanes have been recently exploited for the production of plastic scintillators with very good chemical and thermal stability and very good radiation hardness and the development of polysiloxane liquid scintillators could allow to combine these interesting properties with the supremacy of liquid scintillators as regarding PSD over plastics. For these reasons, the properties of several phenyl-substituted polysiloxane with different phenyl amounts and different viscosities have been investigated, with particular attention to the scintillation response and the pulse shape discrimination capability, and the results of the investigation are reported in this work. More in details, the scintillation light yield towards gamma rays ({sup 60}Co and {sup 137}Cs) of several polysiloxane liquids has been analyzed and compared with the light yield of a commercial non-toxic liquid scintillator (EJ309). The results have been related to the optical characterization of these materials, especially as regarding the fluorescence response, and the best performing material (1,1,5,5-Tetraphenyl 1,3,3,5-Tetramethyl Trisiloxane) showed a scintillation light-yield only slightly lower than EJ309, proving to be a promising candidate for the production of an efficient polysiloxane based liquid scintillator. The results as regarding the neutron-gamma pulse shape discrimination capability of the best performing materials are also reported in this work and the scintillation decay time of these materials are compared to the results of fluorescence lifetime analysis. PSD tests have been performed at CN accelerator in Legnaro National Laboratories with a 2.2 MeV pulsed neutron beam using TOF procedure and the pulses have been analyzed in order to evidence the PSD capability of every sample. The reported results pave the way to the development of a new promising class of non-toxic liquid scintillating materials for neutron detection, with good light output and interesting PSD characteristics. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MAJORANA Collaboration's Experience with Germanium Detectors

A unique way to explore the nature of the neutrino is the search for neutrinoless double beta decay (0νββ). Observation of 0νββ-decay would decisively prove that neutrinos are Majorana particles and that lepton number is violated. The Majorana Demonstrator will perform a search for 0νββ-decay in 76Ge. The experiment is currently under construction at the Sanford Underground Facility (SURF) in South Dakota, USA. The Majorana Demonstrator will use an array of 40 kg of high purity germanium detectors, up to 30 kg of which will be enriched to 86% in 76Ge, surrounded by passive and active shielding. The major goal is to demonstrate a path forward to achieving a background rate at or below 3 counts/(ROI-t-y) in the 4 keV region of interest (ROI) around the 2039 keV Q-value of the 76Ge 0νββ decay. This is required for the next generation of tonne-scale germanium-based 0νββ-decay searches that are designed to probe the neutrino mass scale in the inverted-hierarchy region. Beyond the usage of ultra-clean material and extensive shielding, a key feature to achieve a low background level is a high energy resolution to minimize the ROI and pulse-shape discrimination capability to distinguish signal from background events. These properties are provided by High Purity (HP) P-type Point Contact (PPC) germanium (Ge) detectors. By enriching the natural germanium to 87% in 76Ge the detectors can be used as source and detector simultaneously. At the time of this presentation, 30 enriched detectors with average mass of 840 g have been delivered and successfully tested at SURF. All detectors met the requirements during characterization in vendor cryostat and are now being assembled in the final Majorana Demonstrator experiment.

Mertens, S.↗

Bismuth- and lithium-loaded plastic scintillators for gamma and neutron detection

In this paper, transparent plastic scintillators based on polyvinyltoluene (PVT) have been fabricated with high loading of bismuth carboxylates for gamma spectroscopy, and with lithium carboxylates for neutron detection. When activated with a combination of standard fluors, 2,5-diphenyloxazole (PPO) and tetraphenylbutadiene (TPB), gamma light yields with 15 wt% bismuth tripivalate of 5000 Ph/MeV are measured. A PVT plastic formulation including 30 wt% lithium pivalate and 30 wt% PPO offers both pulse shape discrimination, and a neutron capture peak at ~400 keVee. Finally, in another configuration, a bismuth-loaded PVT plastic is coated with ZnS( 6 Li) paint, permitting simultaneous gamma and neutron detection via pulse shape discrimination with a figure-of-merit of 3.8, while offering gamma spectroscopy with energy resolution of R(662 keV)=15%.

36 MATERIALS SCIENCE↗

Methodology and performance comparison of statistical learning pulse shape classifiers as demonstrated with organic liquid scintillator [Performance comparison of statistical learning pulse shape classifiers]

In this study, we present novel methods for automated pulse shape discrimination. The classifiers are trained using simple radionuclide sources and do not require ground truth labeling. We test their performance using labels derived from time of flight experiments and present the results in terms of energy-dependent Receiver Operating Characteristic (ROC) curves. In addition, we also train and test standard pulse shape discrimination methods on the same data for comparison. We find multiple methods that can yield similar false neutron and true neutron rates at 24 keVee as tail-to-total or Gatti’s optimal linear filter yield at 54 keVee.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

WE-AB-BRB-11: Portable Fast Neutron and Photon Dose Meter

Purpose: To develop an instrument for measuring neutron and photon dose rates from mixed fields with a single device. Methods: Stilbene organic scintillators can be used to detect fast neutrons and photons. Stilbene was used to measure emission from mixed particle sources californium-252 (Cf-252) and plutonium-beryllium (PuBe). Many source detector configurations were used, along with varying amounts of shielding. Collected spectra were analyzed using pulse shape discrimination software, to separate neutron and photon interactions. With a measured light output to energy relationship the pulse height spectrum was converted to energy deposited in the detector. Energy deposited was converted to dose with a variety of standard dose factors, for comparison to current methods. For validation, all measurements and processing was repeated using an EJ-309 liquid scintillator detector. Dose rates were also measured in the same configuration with commercially available dose meters for further validation. Results: Measurements of dose rates will show agreement across all methods. Higher accuracy of pulse shape discrimination at lower energies with stilbene leads to more accurate measurement of neutron and photon deposited dose. In strong fields of mixed particles discrimination can be performed well at a very low energy threshold. This shows accurate dose measurements over a large range of incident particle energy. Conclusion: Stilbene shows promise as a material for dose rate measurements due to its strong ability for separating neutrons and photon pulses and agreement with current methods. A dual particle dose meter would simplify methods which are currently limited to the measurement of only one particle type. Future work will investigate the use of a silicon photomultiplier to reduce the size and required voltage of the assembly, for practical use as a handheld survey meter, room monitor, or phantom installation. Funding From the United States Department of Energy and the National Nuclear Security Administration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Multi-Layer Phoswich Radioxenon Detection System (7th Qtr Report), Reporting Period 10/01/07 - 12/31/07

Description of activities conducted this report period: (1) Electronics Development--To improve the overall performance of the two-channel digital pulse processor (DPP2), the PCB has been redesigned and the new printed board is now under assembly. The system is enhanced with two new fast ADCs from Analog Devices (AD9230-250), each with a sampling rate of 250 MHz and a resolution of 12 bits. The data bus uses a high performance Low Voltage Differential Signaling (LVDS) standard. The offset and gain of each channel are separately controlled digitally by the GUI software. (2) GUI Software Development--A GUI is being developed using the Python programming language. All functions from the preceding MATLAB code have been re-implemented including basic waveform readout, pulse shape discrimination, and plotting of energy spectra. In addition, the GUI can be used to control sampling runs based on the number of pulses captured, either in real or live time. Calibration coefficients and pulse shape discrimination boundaries can be changed on the fly so that the detector may be characterized experimentally. Plots generated by the GUI can be exported as graphic data. At present, the software has only been tested using one channel, pending availability of the new DPP board (DPP2). However, the functions have been written to allow easy expansion to two channels. (3) Light Collection Modeling--The XEPHWICH design has been modeled to determine its light capture efficiency. Research in the 7th quarter includes additional simulations representing significant increase in data resolution, well over an order of magnitude greater than previous simulations. The final data set represents approximately 11 billion visible photons divided equally among 110 thousand data points. A laboratory experiment is being designed and executed to experimentally determine light capture efficiency as a function of position within the scintillators. (4) Radioxenon Fission Source--We have designed and constructed a fission chamber to be used for the collection of radioxenon gases following neutron bombardment of HEU in the Oregon State University TRIGA reactor. The aluminum housing and all vacuum fittings have been assembled, awaiting an HEU transfer from PNNL. Students have worked closely with PNNL and OSU Radiation Safety personnel to facilitate transfer of the HEU. The OSU TRIGA Reactor Operations Committee has approved the experiment. (5) Spectral (beta) Recognition--Spectral identification by a neural network developed in our laboratory was compared to that of solvers of a linear system of equations. Data indicate that our neural network is capable of identifying three beta emission sources ({sup 14}C, {sup 36}Cl, and {sup 99}Tc) simultaneously with reliability to within 3%.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Update on the MiniCLEAN dark matter experiment

The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of order 50 to 100 tonnes. The liquid cryogen is interchangeable between argon and neon to study the A² dependence of the potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular design with spherical geometry to maximize the light yield using cold photomultiplier tubes in a single-phase detector. Pulse shape discrimination techniques are used to separate nuclear recoil signals from electron recoil backgrounds. MiniCLEAN will be spiked with additional ³⁹Ar to demonstrate the effective reach of the pulse shape discrimination capability. Assembly of the experiment is underway at SNOLAB and an update on the project is given.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A combined time-of-flight and depth-of-interaction detector for total-body positron emission tomography

Purpose: In support of a project to build a total-body PET scanner with an axial field-of-view of 2 m, the authors are developing simple, cost-effective block detectors with combined time-of-flight (TOF) and depth-of-interaction (DOI) capabilities. Methods: This work focuses on investigating the potential of phosphor-coated crystals with conventional PMT-based block detector readout to provide DOI information while preserving timing resolution. The authors explored a variety of phosphor-coating configurations with single crystals and crystal arrays. Several pulse shape discrimination techniques were investigated, including decay time, delayed charge integration (DCI), and average signal shapes. Results: Pulse shape discrimination based on DCI provided the lowest DOI positioning error: 2 mm DOI positioning error was obtained with single phosphor-coated crystals while 3–3.5 mm DOI error was measured with the block detector module. Minimal timing resolution degradation was observed with single phosphor-coated crystals compared to uncoated crystals, and a timing resolution of 442 ps was obtained with phosphor-coated crystals in the block detector compared to 404 ps without phosphor coating. Flood maps showed a slight degradation in crystal resolvability with phosphor-coated crystals; however, all crystals could be resolved. Energy resolution was degraded by 3%–7% with phosphor-coated crystals compared to uncoated crystals. Conclusions: These results demonstrate the feasibility of obtaining TOF–DOI capabilities with simple block detector readout using phosphor-coated crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast neutron-gamma discrimination on neutron emission profile measurement on JT-60U

A digital signal processing (DSP) system is applied to stilbene scintillation detectors of the multichannel neutron emission profile monitor in JT-60U. Automatic analysis of the neutron-{gamma} pulse shape discrimination is a key issue to diminish the processing time in the DSP system, and it has been applied using the two-dimensional (2D) map. Linear discriminant function is used to determine the dividing line between neutron events and {gamma}-ray events on a 2D map. In order to verify the validity of the dividing line determination, the pulse shape discrimination quality is evaluated. As a result, the {gamma}-ray contamination in most of the beam heating phase was negligible compared with the statistical error with 10 ms time resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Comparison of Performance Between Organic Scintillation Crystals and Moderated (3)He-Based Detectors for Fission Neutron Detection

Direct detection of fast neutrons using organic scintillators is one alternative to moderated thermal neutron detectors deployed to detect fission neutrons - a relevant question in light of dwindling {sup 3}He supplies. Recent developments in materials science have demonstrated the capability to grow larger crystals in reasonable times. In light of these developments, this study compares the relative performance of a {sup 3}He-based neutron module from a commercially available portal monitor with a theoretical organic scintillator of similar overall size. Stilbene serves as a benchmark with its performance estimated from a combination of energy deposition modeled by radiation transport calculations and an assumption of the lowest neutron energy at which pulse shape discrimination can effectively separate neutron and gamma-ray events. Before intrinsic detection efficiencies on par with moderated detector systems can be achieved, the results point to the need for further advances including significant increases in detector size, especially thickness, and/or lower pulse shape discrimination thresholds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An event-triggered coincidence algorithm for fast-neutron multiplicity assay corrected for cross-talk and photon breakthrough

Here, a model quantifying detector cross-talk and the misidentification of events in fast neutron coincidence distributions is described. This is demonstrated for two experimental arrangements comprising rings of 8 and 15 organic liquid scintillation detectors. Correction terms developed as part of this model are tested with 252 Cf and a relationship is developed between the 235 U enrichment of U 3 O 8 and the order of correlated, fast neutron multiplets induced by an americium–lithium source. The model is also supported by Geant4 simulations. The results suggest that a typical assay, for experimental arrangements that are similar to the examples investigated in this research, will exhibit cross-talk for less than 1% of all detected fast neutrons but, if not accounted for, this can bias the numerical analysis by a margin of 10% and 35% in second- and third-order coincidences (i.e. couplet and triplet counts), respectively. Further, for the case of 252 Cf, it is shown that a relatively low proportion of 4% breakthrough by rays (that is, photons misidentified as neutrons by the pulse-shape discrimination process) can lead to an erroneous increase of 20% in total neutron counts in the assay of a mixed-field, in this case of 252 Cf. These findings will help direct the developments needed to enable organic scintillation detectors with pulse shape discriminators to be applied reliably to nuclear safeguards and non-proliferation verification tasks.

42 ENGINEERING↗

Comparative scintillation performance of EJ-309, EJ-276, and a novel organic glass

An organic glass scintillator developed by Sandia National Laboratories was characterized in terms of its light output and pulse shape discrimination (PSD) properties and compared to commercial liquid (EJ-309) and plastic (EJ-276) organic scintillators. The electron light output was determined through relative comparison of the 137 Cs Compton edge location. The proton light yield was measured using a double time-of-flight technique at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a tunable broad-spectrum neutron source and an array of pulse-shape-discriminating observation scintillators, a continuous measurement of the proton light yield was performed for EJ-309 (200 keV–3.2 MeV), EJ-276 (170 keV–4.9 MeV), and the organic glass (50 keV–20 MeV) . Finally, the PSD properties of the organic glass, EJ-309, and EJ-276 were evaluated using an AmBe source and compared via a figure-of-merit metric. The organic glass exhibited a higher electron light output than both EJ-309 and EJ-276. Its proton light yield and PSD performance were comparable to EJ-309 and superior to that of EJ-276. Finally, with these performance characteristics, the organic glass scintillator is well poised to replace current state-of-the-art PSD-capable scintillators in a range of fast neutron detection applications.

47 OTHER INSTRUMENTATION↗