Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pulse shaping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Serendipitous Detections of XTE J1906+09 with the Rossi X-ray Timing Explorer

In 1996 during Rossi X-ray Timing Explorer (RXTE) observations of SCR 1900+14, the 89-second X-ray pulsar XTE J1906+09 was discovered. As a result of monitoring campaigns of SGR 1900+14, XTE J1906+09 was also monitored regularly in 1996 September, 1998 May-June, 1998 August-1999 July, and 2000 March-2001 January. A frequency grid search of these observations resulted in detections of only the two previously reported outbursts in 1996 September and 1998 August-September. The non-detection of XTE J1906+09 in most observations indicates that it is a transient X-ray pulsar and therefore likely has a Be star companion, Pulse timing analysis of the second outburst revealed a sinusoidal signature in the pulse frequencies that is likely produced by periastron passage in a long period, eccentric, orbit. During the second outburst, the pulse shape changed with increasing intensity, Low intensity pulse profiles from the second outburst are consistent with profiles from the fainter first outburst. Energy dependent pulse shape variations were seen in both outbursts. Pulse phase spectroscopy was used to quantify these variations. The phase averaged spectrum, using the pulse minimum spectrum as the background spectrum to eliminate effects from SGR 1900+14 and the galactic ridge, was well fitted by an absorbed power law with a high energy cutoff with column density N(sub H) = (6 +/- 1) x 10(exp 22) cm(sup -2), photon index = 1.01 +/- 0.08, cutoff energy E(sub cut) = 11 +/- 1 keV, and folding energy E(sub fold) = 19 +/- 4 keV.

Wilson, Colleen A.↗

Development of Large-Scale Magnetic Calorimeter Arrays

We describe performance of large-scale arrays of metallic magnetic calorimeters (MMCs) we are developing to meet requirements of the Lynx X-ray Microcalorimeter (LXM) instrument in the astrophysics mission concept Lynx. We have fabricated prototypes with 55,800 x-ray pixels thermally connected to 5,688 MMC sensors. Subarrays demonstrate three types of pixels, which have different energy and spatial resolution goals in LXM. Pixel pitch is 50 or 25 µm. For two subarrays, use of position sensitive detectors, in a "hydra" configuration with 25 x-ray absorbers per sensor, helps achieve a large focal plane by increasing pixel count relative to readout channels. Since each absorber has a different thermal link to its sensor, it generates a different pulse shape and enables discrimination of pixel position. Superconducting wiring from all sensors was brought out to the perimeter of the overall array using multiple buried metal layers planarized by Chemical Mechanical Planarization to achieve high critical current, low inductance, and high fabrication yield. An automated, algorithmic approach was used to layout the complex wiring pattern. For readout with existing small arrays of Superconducting Quantum Interference (SQUID) amplifiers, 112 selected pixels were connected to wire bond pads. In hydras, we successfully identified 25 pulse shapes using rise-time and pulse height. Pulse shapes were similar to simulations. We measured noise and responsivity to substrate temperature and applied x-ray pulses. While we designed sensors to have high inductance to relative to stray inductance of wiring, we had only mismatched (lower input inductance) SQUIDs available in our current apparatus, giving non-optimized resolution. We compared measured and calculated energy resolutions. We have the required sensitivity to reach < 3 eV FWHM resolution for 6 keV x-rays, required for the LXM Main Array, and the ability to discriminate the 25 different absorber pixels down to energies < 300 eV.

microcalorimeters↗

Shaping Transmitted Pulses To Provide Synchronizing Signals

Report presents theoretical analysis of relationships among: shapes and bandwidths of data pulses in pulse-amplitude modulation (PAM) and quadrature amplitude modulation (QAM); pulse-repetition rates (baud rates); and presence or absence of sinusoidal baud-frequency components in envelopes (magnitudes) of overall received signals.

Satorius, Edgar H.↗

Characterizing the System Impulse Response Function from Photon-Counting LiDAR Data

NASA's Multiple Altimeter Beam Experimental LiDAR (MABEL) is an aircraft-based photon-counting laser altimeter designed as a simulator to test measurement techniques and algorithms for Advanced Topographic Laser Altimeter System (ATLAS), the sole instrument on NASA's Ice, Cloud, and land Elevation Satellite-2 (ICESat-2) mission. By measuring the time of flight, pointing angle, and absolute position for individual photons, ICESat-2 provides detailed elevation measurements of earth's surface. Calculating accurate and precise elevations requires an understanding of how photons interact with surfaces, and characterization of the photon distribution after returning from surfaces. Neither MABEL nor ATLAS records the transmitted laser pulse shape, relying instead on aggregating several pulses worth of photons, often using histograms, to characterize the pulse shape. In this paper, we assess the limitations of using histograms and propose a more robust method to describe MABEL's system impulse-response function using an exponentially modified Gaussian distribution. We also provide standard error estimates for the arithmetic mean and standard deviation calculations, and for exponentially modified Gaussian parameters using a Monte Carlo sensitivity analysis. We apply this method to photon returns from a sea ice lead and from a dry salt lake bed as case studies for estimating the standard error associated with sample size for the arithmetic mean and standard deviation, and for the exponentially modified Gaussian parameters. We use these standard errors to calculate the minimum number of photons required to find both Gaussian and exponentially modified Gaussian distribution parameters within 3 cm of their parent population values.

photoncounting↗

On the power spectral density of quadrature modulated signals

The conventional (no-offset) quadriphase modulation technique suffers from the fact that hardlimiting will restore the frequency sidelobes removed by proper filtering. Thus, offset keyed quadriphase modulation techniques are often proposed for satellite communication with bandpass hardlimiting. A unified theory is developed which is capable of describing the power spectral density before and after the hardlimiting process. Using the in-phase and the quadrature phase channel with arbitrary pulse shaping, analytical results are established for generalized quadriphase modulation. In particular MSK, OPSK or the recently introduced overlapped raised cosine keying all fall into this general category. It is shown that for a linear communication channel, the power spectral density of the modulated signal remains unchanged regardless of the offset delay. Furthermore, if the in phase and the quadrature phase channel have identical pulse shapes without offset, the spectrum after bandpass hardlimiting will be identical to that of the conventional QPSK modulation. Numerical examples are given for various modulation techniques. A case of different pulse shapes in the in phase and the quadrature phase channel is also considered.

Yan, T. Y.↗

Multi-Absorber Transition-Edge Sensors for X-Ray Astronomy Applications

We are developing multi-absorber Transition-Edge Sensors (TESs) for applications in x-ray astronomy. These position-sensitive devices consist of multiple x-ray absorbers each with a different thermal coupling to a single readout TES. Heat diffusion between the absorbers and the TES gives rise to a characteristic pulse shape corresponding to each absorber element and enables position discrimination. The development of these detectors is motivated by a desire to maximize focal plane arrays with the fewest number of readout channels. In this contribution we report on the first results from devices consisting of nine) 65 X 65 sq. microns Au x-ray absorbers) 5 microns thick. These are coupled to a single 35 X 35 sq. microns Mo/Au bilayer TES. These devices have demonstrated full-width-half-maximum (FWHM) energy resolution of 2.1 eV at 1.5 keV) 2.5 eV at 5.9 keV and 3.3 eV at 8 keV. This is coupled with position discrimination from pulse shape over the same energy range. We use a finite-element model to reproduce the measured pulse shapes and investigate the detector non-linearity with energy) which impacts on the devices position sensitivity and energy resolution.

Smith, S. J.↗

Nuclear pumped laser research at the Jet Propulsion Laboratory

Using a partially nuclear excited xenon flashlamp to pump an iodine laser, laser pulse shapes were analyzed with and without nuclear flashlamp augmentation. The pulse shapes indicate that the deposition of nuclear energy is equally as effective as electrical energy deposition in producing laser pulse energy output. The amplification of the E-beam pumped CF3I was measured at pressures of several atmospheres. Preliminary data shows that, for a part of the iodine laser pulse, amplification of almost a factor of two is measured. This measurement indicates that the gain in an E-beam pumped CF3I is an order of magnitude greater than in the coaxial laser tube.

Russell, G. R.↗

Simulation of gamma-ray spectra for a variety of user-specified detector designs

The gamma-ray spectrum simulation program BSIMUL was designed to allow the operator to follow the path of a gamma-ray through a detector, shield and collimator whose dimensions are entered by the operator. It can also be used to simulate spectra that would be generated by a detector. Several improvements have been made to the program within the last few months. The detector, shield and collimator dimensions can now be entered through an interactive menu whose options are discussed below. In addition, spectra containing more than one gamma-ray energy can now be generated with the menu - for isotopes listed in the program. Adding isotopes to the main routine is also quite easy. Subroutines have been added to enable the operator to specify the material and dimensions of a collimator. This report details the progress made in simulating gamma-ray spectra for a variety of user-specified detector designs. In addition, a short discussion of work done in the related areas of pulse shape analysis and the spectral analysis is included. The pulse shape analysis and spectral analysis work is being performed pursuant to the requirements of contract F-94-C-0006, for the Advanced Research Projects Agency and the U.S. Air Force.

Rester, A. C., Jr.↗

Discovery of X-ray pulsations in SMC X-1

Observations of SMC X-1 from an Aerobee rocket and an Apollo spacecraft have detected X-ray pulsations with a period of 0.716 s. The pulsed fraction in the 1.6-10-keV energy range is 25-35 percent. Evidence for significant pulse-shape and pulsed-fraction changes in the 0.6-1.6-keV range is also presented. The spectrum during both observations is fitted by a photon power law with a spectral index of -0.8 and normalization of 0.040.

Lucke, R.↗

X-ray observations of 4U 1626-67 by the monitor counter on the Einstein /HEAO 2/ observatory

The pulsing X-ray source 4U 1626-67 was observed with the Monitor Proportional Counter (MPC) on board the Einstein X-Ray Observatory on three occasions in early 1979. The MPC is a sealed, argon-filled proportional counter with a 1.5 mil beryllium window and is coaligned with the X-ray telescope on board the observatory. The spectral data spanning the energy range from 1.1 to 21 keV are divided into eight logarithmically spaced energy channels which integrate for 2.56 s. The Time Interval Processor (TIP) circuitry of the MPC measures time intervals between events to within 1 microsecond or 1.6%, whichever is larger, for a count rate dependent fraction of all events in all eight energy channels. It is found that in the energy range from 1 to 21 keV, the spectrum and 7.7 s pulse shape of 4U 1626-67 are variable on a time scale of minutes. The pulse shape variations correlate in a complex way with the intensity variations in this source.

Elsner, R. F.↗

Laser/lidar analysis and testing

Section 1 of this report details development of a model of the output pulse frequency spectrum of a pulsed transversely excited (TE) CO2 laser. In order to limit the computation time required, the model was designed around a generic laser pulse shape model. The use of such a procedure allows many possible laser configurations to be examined. The output pulse shape is combined with the calculated frequency chirp to produce the electric field of the output pulse which is then computationally mixed with a local oscillator field to produce the heterodyne beat signal that would fall on a detector. The power spectral density of this heterodyne signal is then calculated. Section 2 reports on a visit to the LAWS laser contractors to measure the performance of the laser breadboards. The intention was to acquire data using a digital oscilloscope so that it could be analyzed. Section 3 reports on a model developed to assess the power requirements of a 5J LAWS instrument on a Spot MKII platform in a polar orbit. The performance was assessed for three different latitude dependent sampling strategies.

Spiers, Gary D.↗

Characterization of EJ-270 and Ce-doped LiCAF scintillators for the development of high-rate neutron reflectometer detectors

The Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory is anticipated to provide a neutron source with ∼20 times increase in peak brightness than the First Target Station. The neutron reflectometers currently in operation at the First Target Station need to be upgraded due to the increased neutron flux. A prototype neutron detector module based upon a pixelated scintillator array readout by silicon photomultipliers is being developed to address the high-rate challenge faced with future neutron reflectometer instruments at the Second Target Station. Two types of scintillator materials were considered for this detector development, i.e., 6 Li-loaded EJ-270 plastic scintillator and Ce-doped LiCAF single crystal. This paper reports the scintillator characterization results, including light yield, pulse shape discrimination performance, capability to detect thermal neutrons in a high γ-ray field, and γ-ray sensitivity. The number of photons produced per neutron capture by EJ-270 and LiCAF:Ce was measured to be 2176 ± 91 and 2651 ± 108, respectively. EJ-270 demonstrated a good capability to discriminate between neutrons and γ-rays by employing the commonly used charge comparison method (figure-of-merit: 1.13 ± 0.01 for an energy cut of 292–426 keVee) and a reasonable performance when using the time-over-threshold techniques; however, no discrimination was observed from LiCAF:Ce regardless of the pulse shape discrimination approaches utilized, making pulse height discrimination necessary for LiCAF:Ce to differentiate between neutrons and γ-rays. Both EJ-270 and LiCAF:Ce exhibited an acceptable capacity to detect thermal neutrons at high exposure rates up to approximately 584 mR/h. Furthermore, the γ-ray sensitivities measured with a 60 Co source at an exposure rate of around 1145 mR/h were determined to be (6.11 ± 0.87) × 10 −6 and (7.64 ± 1.08) × 10 −7 for EJ-270 and LiCAF:Ce, respectively.

EJ-270↗

Propellant injection for MPD thrusters

The propellant gas for a pulsed self-field MPD thruster must be supplied by a valve which will necessarily be separated from the thruster injectors by some ullage volume. A model and experimental data are presented showing the effect of the ullage volume on the propellant pulse shape, along with a discussion of the proper location for the propellant flow choke point(s). Prospective MPD pulse valves are surveyed and the performance of two solenoid valves, one with a pulse length less than 2 milliseconds, is included. Pulse shape data is presented for a thruster specially modified to reduce the ullage volume.

Jones, R. M.↗

Acoustic pulse propagation in a duct with flow

The effect of a mean flow on acoustic pulse propagation in a wind tunnel of rectangular cross-section is considered both experimentally and theoretically. Pulse shapes in the wind tunnel are recorded by microphones located upstream and downstream of a source. A theoretical model of pulse propagation from a point source located in an infinitely-long rectangular duct carrying a uniform flow is considered. The convective wave equation with boundary conditions appropriate to hard walls is solved by using the Laplace transform. For the input pulse shape used in the experiments, the solution is obtained by numerically evaluating the inverse Laplace transform. The results of experiment and theory are seen to be in good agreement.

Cole, J. E., III↗

Multi-channel, multi-template event reconstruction for SuperCDMS data using machine learning

SuperCDMS SNOLAB uses kilogram-scale germanium and silicon detectors to search for dark matter. Each detector has Transition Edge Sensors (TESs) patterned on the top and bottom faces of a large crystal substrate, with the TESs electrically grouped into six phonon readout channels per face. Noise correlations are expected among a detector's readout channels, in part because the channels and their readout electronics are located in close proximity to one another. Moreover, owing to the large size of the detectors, energy deposits can produce vastly different phonon propagation patterns depending on their location in the substrate, resulting in a strong position dependence in the readout-channel pulse shapes. Both of these effects can degrade the energy resolution and consequently diminish the dark matter search sensitivity of the experiment if not accounted for properly. We present a new algorithm for pulse reconstruction, mathematically formulated to take into account correlated noise and pulse shape variations. This new algorithm fits N readout channels with a superposition of M pulse templates simultaneously - hence termed the N$\times$M filter. We describe a method to derive the pulse templates using principal component analysis (PCA) and to extract energy and position information using a gradient boosted decision tree (GBDT). We show that these new N$\times$M and GBDT analysis tools can reduce the impact from correlated noise sources while improving the reconstructed energy resolution for simulated mono-energetic events by more than a factor of three and for the 71Ge K-shell electron-capture peak recoils measured in a previous version of SuperCDMS called CDMSlite to $<$ 50 eV from the previously published value of $\sim$100 eV. These results lay the groundwork for position reconstruction in SuperCDMS with the N$\times$M outputs.

Albakry, M. F. [British Columbia U.; TRIUMF]↗

An MSK Radar Waveform

The minimum-shift-keying (MSK) radar waveform is formed by periodically extending a waveform that separately modulates the in-phase and quadrature- phase components of the carrier with offset pulse-shaped pseudo noise (PN) sequences. To generate this waveform, a pair of periodic PN sequences is each passed through a pulse-shaping filter with a half sinusoid impulse response. These shaped PN waveforms are then offset by half a chip time and are separately modulated on the in-phase and quadrature phase components of an RF carrier. This new radar waveform allows an increase in radar resolution without the need for additional spectrum. In addition, it provides self-interference suppression and configurable peak sidelobes. Compared strictly on the basis of the expressions for delay resolution, main-lobe bandwidth, effective Doppler bandwidth, and peak ambiguity sidelobe, it appears that bi-phase coded (BPC) outperforms the new MSK waveform. However, a radar waveform must meet certain constraints imposed by the transmission and reception of the modulation, as well as criteria dictated by the observation. In particular, the phase discontinuity of the BPC waveform presents a significant impediment to the achievement of finer resolutions in radar measurements a limitation that is overcome by using the continuous phase MSK waveform. The phase continuity, and the lower fractional out-of-band power of MSK, increases the allowable bandwidth compared with BPC, resulting in a factor of two increase in the range resolution of the radar. The MSK waveform also has been demonstrated to have an ambiguity sidelobe structure very similar to BPC, where the sidelobe levels can be decreased by increasing the length of the m-sequence used in its generation. This ability to set the peak sidelobe level is advantageous as it allows the system to be configured to a variety of targets, including those with a larger dynamic range. Other conventionally used waveforms that possess an even greater spectral efficiency than the MSK waveform, such as linear frequency modulation (LFM) and Costas frequency hopping, have a fixed peak sidelobe level that is therefore not configurable, and can be exceeded by high contrast targets. Furthermore, in the case of a multistatic experiment observing a target in motion, self-interference from the transmitter to the receiver is mitigated by the MSK waveform. Waveforms that have delay Doppler coupling, such as LFM, provide no such protection.

Quirk, Kevin J.↗

Low energy backgrounds and excess noise in a two-channel low-threshold calorimeter

Here, we describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a transition edge sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: “shared” multichannel events with a pulse shape consistent with substrate athermal phonon events and sub-eV events that couple nearly exclusively to a single channel with a significantly faster pulse shape. These “singles” are consistent with events occurring within the aluminum athermal phonon collection fins. Similarly, our measured detector noise is higher than the theoretical expectation. Measured noise can be split into an uncorrelated component, consistent with shot noise from small energy depositions within the athermal phonon sensor itself, and a correlated component, consistent with shot noise from energy depositions within the silicon substrate's phonon system.

47 OTHER INSTRUMENTATION↗

Parallel-Processing CMOS Circuitry for M-QAM and 8PSK TCM

There has been some additional development of parts reported in "Multi-Modulator for Bandwidth-Efficient Communication" (NPO-40807), NASA Tech Briefs, Vol. 32, No. 6 (June 2009), page 34. The focus was on 1) The generation of M-order quadrature amplitude modulation (M-QAM) and octonary-phase-shift-keying, trellis-coded modulation (8PSK TCM), 2) The use of square-root raised-cosine pulse-shaping filters, 3) A parallel-processing architecture that enables low-speed [complementary metal oxide/semiconductor (CMOS)] circuitry to perform the coding, modulation, and pulse-shaping computations at a high rate; and 4) Implementation of the architecture in a CMOS field-programmable gate array.

Gray, Andrew↗