Monitoring and Modeling Astronaut Occupational Radiation Exposures in Space: Recent Advances

In 1982 astronauts were declared to be radiation workers by OSHA, and as such were subject to the rules and regulations applied to that group. NASA was already aware that space radiation was a hazard to crewmembers and had been studying and monitoring astronaut doses since 1962 at the Johnson Space Center. It was quickly realized NASA would not be able to accomplish all of its goals if the astronauts were subject to the ground based radiation worker limits, and thus received a waiver from OSHA to establish independent limits. As part of the stipulation attached to setting new limits, OSHA included a requirement to perform preflight dose projections for each crew and inform them of the associated risks. Additional requirements included measuring doses from various sources during the flight, making every effort to prevent a crewmember from exceeding the new limits, and keeping all exposures As Low As Reasonably Achievable (a.k.a. ALARA - a common health physics principle). The assembly of the International Space Station (ISS) and its initial manned operations will coincide with the 4-5 year period of high space weather activity at the next maximum in the solar cycle. For the first time in NASA's manned program, US astronauts will be in orbit continuously throughout a solar maximum period. During this period, crews are at risk of significantly increased radiation exposures due to solar particle events and trapped electron belt enhancements following geomagnetic storms. The problem of protecting crews is compounded by the difficulty of providing continuous real-time monitoring over a period of a decade in an era of tightly constrained budgets. In order to prepare for ISS radiological support needs, the NASA Space Radiation Analysis Group and the NOAA Space Environment Center have undertaken a multiyear effort to improve and automate ground-based space weather monitoring systems and real-time radiation analysis tools. These improvements include a coupled, automated space weather monitoring and alarm system--SPE exposure analysis system, an advanced space weather data distribution and display system, and a high-fidelity space weather simulation system. In addition, significant new real-time space weather data sets, which will enhance the forecasting and now-casting of near-Earth space environment conditions, are being made available through unique NASA-NOAA-USAF collaborations. These new data sets include coronal mass ejection monitoring by the Solar and Heliospheric Observatory (SOHO) and in-situ plasma and particle monitoring at the L1 libration point by the Solar Wind Monitor (SWIM) and Advanced Composition Explorer (ACE) spacecraft. Advanced real-time radiation monitoring data from charged particle telescopes and tissue equivalent proportional counters will also be available to assist crew and flight controllers in monitoring the external and intravehicular radiation environment.

Weyland, Mark↗

Recent space shuttle observations of the South Atlantic anomaly and the radiation belt models

Active ingredients consisting of Tissue Equivalent Proportional Counter (TEPC) and a Proton and Heavy Ion Detector (PHIDE) have been carried on a number of Space Shuttle flights. These instruments have allowed us to map out parts of the South Atlantic Particle Anomaly (SAA) and to compare some of it's features with predictions of the AP-8 energetic proton flux models. We have observed that consistent with the generally observed westward drift of the surface features of the terrestial magnetic field of the SAA has moved west by about 6.9 degrees longitude between the epoch year 1970 of the AP-8 solar maximum model and the Space Shuttle observations made twenty years later. However, calculations indicate that except for relatively brief periods following very large magnetic storms the SAA seems to occupy the same position in L-space as in 1970. After the great storm of 24 March 1991 reconfiguration of the inner radiation belt and/or proton injection into the inner belt, a second energetic proton belt was observed to form at approximately equal to 2. As confirmed by a subsequent flight observations, this belt was shown to persist at least for six months. Our measurements also indicate an upward shift in the L location of the primary belt from L = 1.4 to L = 1.5. In addition we confirm through direct real time observations the existence and the approximate magnitude of the East-West effect. If the need exists for improved and updated radiation belt models in the Space Station era, these observations point out the specific features that should be considered and incorporated when this task is undertaken.

Konradi, A.↗

Precise absolute 𝛾–ray intensities following the 𝛽 decay of 156 Eu

The most recent 𝛽-decay data for 156 Eu is over 40 years old, and the 𝛾-ray intensities are only known with a fractional precision of about 10% or worse. Here, in this work, we present new results for the absolute intensities of more than 60 𝛾 rays emitted following the 𝛽 decay of 156 Eu with many measured to ≲1% accuracy, representing an order-of-magnitude improvement in precision. This was achieved by leveraging the fission-product beams produced at the CARIBU facility to create radio-pure samples and detecting the radiation with a 4⁢𝜋 𝛽-particle counter coupled with a precisely efficiency-calibrated HPGe detector at Texas A and M University.

Physics - Nuclear physics and radiation physics↗

Sea Ice and Cloud Processes Mediating Compensation between Atmospheric and Oceanic Meridional Heat Transports across the CMIP6 Preindustrial Control Experiment

Abstract Bjerknes compensation (BJC) refers to the anticorrelation observed between atmospheric and oceanic heat transport (AHT/OHT) variability, particularly on decadal to longer time scales that may be important to the predictability of the climate system. This study investigates the spread in BJC across fully coupled simulations of phase 6 of the Coupled Model Intercomparison Project (CMIP6) and critical processes (particularly related to sea ice and clouds) that may contribute to that spread. BJC on decadal to longer time scales is confirmed across all the simulations evaluated, and it is strongest in the Northern Hemisphere (NH) between 60° and 70°N. At these latitudes, BJC appears to be primarily driven by the exchange of turbulent fluxes (sensible and latent) in the Greenland, Iceland, and Barents Seas. Metrics to break down how sea ice and clouds uniquely modify the radiative balance of the polar atmosphere during anomalous OHT events are presented. These metrics quantify the impacts of sea ice and clouds on surface and top of atmosphere (latent, sensible, longwave, and shortwave radiative) energy fluxes. Cloud responses tend to counter the clear sky impacts over the Marginal Ice Zone (MIZ). It is further shown that the degree of BJC present in a simulation at high latitudes is heavily influenced by the sensitivity of the sea ice to OHT, which is most influential over the MIZ. These results are qualitatively robust across models and explain the intermodel spread in NH BJC in the preindustrial control experiment.

54 ENVIRONMENTAL SCIENCES↗

Optical Particle Measurements during EPCAPE Field Campaign Report

This campaign requested the deployment of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility optical particle counter (OPC) at the first ARM Mobile Facility (AMF1) located at the Scripps Pier in La Jolla, California during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE). The addition of the OPC was requested for two reasons. (1) Close the gap between the scanning mobility particle sizer (SMPS) and aerodynamic particle sizer (APS) size distribution from the Aerosol Observing System (AOS) measurements. (2) Principal investigator Petters has been working with Tracking Aerosol Convection Interaction Experiment (TRACER) data to compute particle fluxes from Doppler lidar (Petters et al. 2024). Briefly, backscatter flux is obtained using the eddy covariance technique using the Doppler vertical velocity and attenuated backscatter. Building upon prior studies, we were able to relate backscatter to particle number concentration by calibrating the lidar retrievals against optical particle counter-measured ground-based aerosol size distribution and radiosonde-interpolated relative humidity at lidar sample height. Performing similar analysis was of interest to EPCAPE to better understand the emissions and vertical transport of large particles into the overlying stratus clouds. However, as stated above, this analysis requires an optical size distribution that covers the 0.3-30-μm-diameter size range. The OPC was deployed between 2023-04-14 and 2024-02-14. The deployment, data quality analysis, and data archiving was handled by the DOE ARM instrument mentor team without additional involvement by the principal investigator. Data quality was marked as “routine” for the majority of the campaign.

54 ENVIRONMENTAL SCIENCES↗

An analysis of energy deposition in a tissue equivalent proportional counter onboard the space shuttle

An improved prediction for space radiations in the lower earth orbits measured by the shuttle TEPC is obtained when energy loss straggling and chord length distribution of the detector are considered. A generalized analytic model is used to describe the energy deposition of direct ion interaction events in a micron-size detector. The transport calculation accounting for the shuttle configuration is accomplished by using a new version of HZETRN that has been extensively verified with laboratory and flight data. The agreement of predicted and measured lineal energy spectra is within 70% for the region above 2 keV/micrometer but within a factor of 2.3 underpredicted for the region below this value. The inclusion of indirect delta ray events in the model is needed before possible causes for the underprediction below 2 keV/micrometer can be assessed.

Flight Experiment↗

The heavy nuclei experiment on HEAO-3

The HEAO-3 experiment to study the heavy and ultraheavy nuclei in cosmic radiation is described. The array is double-ended and consists of three main elements. Two pressure chambers, filled with an argon-methane mixture at about 850 torr, each contain two x-y hodoscopes made of wires spaced 1 cm apart and three parallel plate ionization chambers. Between the pressure chambers is mounted a Cerenkov counter composed of two layers of Pilot 425 radiator looked at by eight photomultipliers. The instrument is designed to achieve a charge resolution of 0.3 charge units over the charge range 17-120, which requires a measurement accurate to 0.6 percent at Z = 100. Examination of selected data shows that the instrument has the intrinsic resolution needed.

Binns, W. R.↗

The response of tissue-equivalent proportional counters to heavy ions

The paper presents a theoretical model for the response of a tissue-equivalent proportional counter (TEPC) irradiated with charged particles. Heavy ions and iron ions in particular constitute a significant part of radiation in space. TEPCs are used for all space shuttle and International Space Station (ISS) missions to estimate the dose and radiation quality (in terms of lineal energy) inside spacecraft. The response of the tissue-equivalent proportional counters shows distortions at the wall/cavity interface. In this paper, we present microdosimetric investigation using Monte Carlo track structure calculations to simulate the response of a TEPC to charged particles of various LET (1 MeV protons, 2.4 MeV alpha particles, 46 MeV/nucleon 20Ne, 55 MeV/nucleon 20Ne, 45 MeV/nucleon 40Ar, and 1.05 GeV/nucleon 56Fe). Data are presented for energy lost and energy absorbed in the counter cavity and wall. The model calculations are in good agreement with the results of Rademacher et al. (Radiat. Res. 149, 387-389, 1998), including the study of the interface between the wall and the sensitive region of the counter. It is shown that the anomalous response observed at large event sizes in the experiment is due to an enhanced entry of secondary electrons from the wall into the gas cavity.

NASA Discipline Radiation Health↗

Space radiation absorbed dose distribution in a human phantom

The radiation risk to astronauts has always been based on measurements using passive thermoluminescent dosimeters (TLDs). The skin dose is converted to dose equivalent using an average radiation quality factor based on model calculations. The radiological risk estimates, however, are based on organ and tissue doses. This paper describes results from the first space flight (STS-91, 51.65 degrees inclination and approximately 380 km altitude) of a fully instrumented Alderson Rando phantom torso (with head) to relate the skin dose to organ doses. Spatial distributions of absorbed dose in 34 1-inch-thick sections measured using TLDs are described. There is about a 30% change in dose as one moves from the front to the back of the phantom body. Small active dosimeters were developed specifically to provide time-resolved measurements of absorbed dose rates and quality factors at five organ locations (brain, thyroid, heart/lung, stomach and colon) inside the phantom. Using these dosimeters, it was possible to separate the trapped-proton and the galactic cosmic radiation components of the doses. A tissue-equivalent proportional counter (TEPC) and a charged-particle directional spectrometer (CPDS) were flown next to the phantom torso to provide data on the incident internal radiation environment. Accurate models of the shielding distributions at the site of the TEPC, the CPDS and a scalable Computerized Anatomical Male (CAM) model of the phantom torso were developed. These measurements provided a comprehensive data set to map the dose distribution inside a human phantom, and to assess the accuracy and validity of radiation transport models throughout the human body. The results show that for the conditions in the International Space Station (ISS) orbit during periods near the solar minimum, the ratio of the blood-forming organ dose rate to the skin absorbed dose rate is about 80%, and the ratio of the dose equivalents is almost one. The results show that the GCR model dose-rate predictions are 20% lower than the observations. Assuming that the trapped-belt models lead to a correct orbit-averaged energy spectrum, the measurements of dose rates inside the phantom cannot be fully understood. Passive measurements using 6Li- and 7Li-based detectors on the astronauts and inside the brain and thyroid of the phantom show the presence of a significant contribution due to thermal neutrons, an area requiring additional study.

STS-91 Shuttle Project↗

Measurements on the shuttle of the LET spectra of galactic cosmic radiation and comparison with the radiation transport model

A new class of tissue-equivalent proportional counters has been flown on two space shuttle flights. These detectors and their associated electronics cover a lineal energy range from 0.4 to 1250 keV/microns with a multichannel analyzer resolution of 0.1 keV/microns from 0.4 to 20 keV/microns and 5 keV/microns from 20 to 1250 keV/microns. These detectors provide the most complete dynamic range and highest resolution of any technique currently in use. On one mission, one detector was mounted in the Shuttle payload bay and another older model in the mid-deck, thus providing information on the depth dependence of the lineal energy spectrum. A detailed comparison of the observed lineal energy and calculated LET spectra for galactic cosmic radiation shows that, although the radiation transport models provide a rather accurate description of the dose (+/- 15%) and equivalent dose (+/- 15%), the calculations significantly underestimate the frequency of events below about 100 keV/microns. This difference cannot be explained by the inclusion of the contribution of splash protons. The contribution of the secondary pions, kaons and electrons produced in the Shuttle shielding, if included in the radiation transport model, may explain these differences. There are also significant differences between the model predictions and observations above 140 keV/microns, particularly for 28.5 degrees inclination orbit.

NASA Discipline Radiation Health↗

Irradiating of Bulk Soybeans: Influence on Their Functional and Sensory Properties for Soyfood Processing

Soybeans were chosen for lunar and planetary missions, where soybeans will be supplied in bulk or grown locally, due to their nutritive value and ability to produce oil and protein for further food applications. However, soybeans must be processed into foods prior to consumption. Radiation that soybeans would be exposed to during bulk storage prior to and during a Mars mission may influence their germination and functional properties. The influence of radiation includes the affect of surface pasteurization to ensure the astronauts safety from food-borne illnesses (HACCP, CCP), and the affect of the amount of radiation the soybeans receive during a Mars mission. Decreases in the amount of natural antioxidants free radical formation, and oxidation-induced changes in the soybean will influence the nutritional value, texture, color, and aroma of soyfoods. The objective of this study was to determine the influence of pasteurization and sterilization surface radiation on whole soybeans using gamma and electron beam radiation. The influence of 0, 1, 5, 10, and 30kGy on microbial load, germination rate, ease of processing, and quality of soymilk and tofu were determined. Surface radiation of whole dry soybeans using electron beam or gamma rays from 1-30kGy did provide microbial safety for the astronauts. However, the lower dose levels had surviving yeasts and molds. These doses caused oxidative changes that resulted in soymilk and tofu with rancid aromas. GC-MS of the aroma compounds using SPME Headspace confirmed the presence of lipid oxidation compounds. Soybean germination ability was reduced as radiation dosage increased. While lower doses may reduce these problems, the ability to insure microbial safety of bulk soybeans will be lost. Counter measures could include vacuum packaging, nitrogen flushing, added antioxidants, and radiating under freezing conditions. Doses below 1kGy need to be investigated further to determine the influence of the radiation encountered during Mars missions.

Chia, Chiew-Ling↗

Space Radiation Organ Doses for Astronauts on Past and Future Missions

We review methods and data used for determining astronaut organ dose equivalents on past space missions including Apollo, Skylab, Space Shuttle, NASA-Mir, and International Space Station (ISS). Expectations for future lunar missions are also described. Physical measurements of space radiation include the absorbed dose, dose equivalent, and linear energy transfer (LET) spectra, or a related quantity, the lineal energy (y) spectra that is measured by a tissue equivalent proportional counter (TEPC). These data are used in conjunction with space radiation transport models to project organ specific doses used in cancer and other risk projection models. Biodosimetry data from Mir, STS, and ISS missions provide an alternative estimate of organ dose equivalents based on chromosome aberrations. The physical environments inside spacecraft are currently well understood with errors in organ dose projections estimated as less than plus or minus 15%, however understanding the biological risks from space radiation remains a difficult problem because of the many radiation types including protons, heavy ions, and secondary neutrons for which there are no human data to estimate risks. The accuracy of projections of organ dose equivalents described here must be supplemented with research on the health risks of space exposure to properly assess crew safety for exploration missions.

Cucinotta, Francis A.↗

What Threats to Human Health Does Space Radiation Pose in Orbit

The Space Shuttle program spanned more than the entire length of a solar cycle. Investigations aimed towards understanding the health risks of the astronauts from exposures to space radiation involved mostly physical measurements of the dose and the linear energy transfer (LET) spectrum. Measurement of the dose rate on the Shuttle provided invariable new data for different periods of the solar cycle, whereas measurement of the LET spectrum using the tissue equivalent proportional counter (TEPC) produced the most complete mapping of the radiation environment of the low Earth orbits (LEO). Exposures to the Shuttle astronauts were measured by the personal dosimeter worn by the crewmembers. Analysis of over 300 personal dosimeter readings indicated a dependence on the mission duration, the altitude and inclination of the orbit, and the solar cycle, with the crewmembers on the launch and repair of the Hubble telescope receiving the highest doses due to the altitude of the mission. Secondary neutrons inside the Shuttle were determined by recoil protons or with Bonner spheres, and may contribute significantly to the risks of the crewmembers. In addition, the skin dose and the doses received at different organs were compared using a human phantom onboard a Shuttle mission. A number of radiobiology investigations wer e also performed. The biological doses were determined on six astronauts/cosmonauts on long-duration Shuttle/Mir missions and on two crewmembers on a Hubble repair mission by analyzing the damages in the chromosomes of the crewmembers? white blood cells. Several experiments were also conducted to address the question of possible synergistic effects of spaceflight, microgravity in particular, on the repair of radiation-induced DNA damages. The experimental design included exposure of cells before launch, during flight, or after landing. These physical and biological studies were invaluable in predicting the health risks for astronauts on ISS and future exploration missions. Educational Objectives: A group of high school students flew color negative films on tw o Shuttle missions to detect the radiation environment in orbit. This and other experiments onboard of the Shuttle were aimed at educating the general public of the space program.

Wu, Honglu↗

An instrument employing electronic counters and an emulsion chamber for studying heavy cosmic ray interactions (JACEE-3)

A JACEE-3 instrument was flown on a balloon in June 1982 for 6.1 sq m sr hr exposure at an average atmospheric depth of 5 gm/sq cm in order to study the cosmic ray spectra, composition, and interactions above 1 TeV. The nucleus-nucleus interactions were studied above 20 GeV/amu from z = 6 to z = 26. The electronic counters contained gas Cerenkov structures with a 1.0-cm thick lead glass and a 1.27-cm thick Teflon radiator. A comparison to the instrument prototype is made. Based on the electronic counter event data, the finding efficiency of the hodoscope is noted to be near 100 percent for z greater than or equal to 22. A comparison is made between the hodoscope-predicted position and track found at P3 in an emulsion chamber.

Austin, R. W.↗

Acute Effects of Simulated Space Radiation and Micro-Gravity on Cancellous Bone Loss in Mice Tibiae

Space radiation and micro-gravity are the two major obstacles impeding human exploration of Mars and beyond. Long-duration space flights expose astronauts to high doses of high linear energy transfer (LET) radiation as well as prolonged periods of skeletal disuse due to weightlessness. One important consequence of both radiation exposure and micro-gravity is acute bone loss. However, biological responses to different radiation types and combined radiation and micro-gravity environments remain unknown. Thus, the purpose of this study is to compare the acute effects of different radiation species and simulated weightlessness on bone degeneration for the purpose of developing accurate risk assessments of prolonged space flight. Mouse models were used to simulate space flight-relevant doses of different radiation types as well as weightlessness via hind-limb unloading. Three groups of mice (n 9) were irradiated with 1 Gy (Gray) H+, 1 Gy 56Fe, and 1 Gy combined H+ and 56Fe (dual ion) respectively and compared to sham irradiated (n 9) and 2 Gy 56Fe irradiated positive controls (n 6). Two groups of mice (n 9) were hind-limb unloaded for three days and then either sham irradiated or dual ion irradiated respectively, followed by subsequent hind-limb unloading for 11 days. Cancellous tissue from tibiae metaphyses were harvested 11 days post-irradiation for ex vivo micro-computed tomography analysis. Microarchitecture parameters including bone volume to total volume ratio (BVTV), trabecular thickness (Tb.Th), trabecular number (Tb.N), trabecular spacing (Tb.S), and connectivity density (Conn.D) will be quantified using a novel automated segmentation procedure developed in our lab. The anticipated results will be instrumental in developing counter-measures against micro-gravity and radiation-induced bone loss. Moreover, possible synergistic effects may provide insight into underlying mechanisms mediating biological response.

Micro-Gravity↗

Determination of γ-ray branching ratios for ⁹⁵Zr and ¹⁴⁷Nd

For many fission products, the γ rays emitted following decay provide an easily-detectable signature that can be used to identify their quantities and distributions in a sample. As a result, γ-ray spectroscopy is often exploited to study fission-product yields (FPYs), provided sufficiently accurate information on the γ-ray branching ratio is available. However, in many cases, the uncertainties in the existing nuclear data are large enough that they compromise the precision achievable for modern experiments and applications. To address this need, we have developed a new experimental method that is well suited to precisely measure the γ-ray branching ratios in the decay of long-lived fission products. The approach involves the production of a radiopure sample by implantation of a mass-separated ion beam from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) facility on a thin carbon foil. The emitted β -decay radiation is detected with a 4π gas proportional counter and a meticulously efficiency-calibrated high-purity germanium (HPGe) detector. As a first measurement to demonstrate the approach, we studied the γ-ray branching ratios of the strongest transitions following the decay of ⁹⁵Zr and decay-daughter ⁹⁵Nb and determined these branching ratios to fractional precisions of 1%. We then applied this approach to determine the γ-ray branching ratios for the β decay of ¹⁴⁷Nd. The results for the γ-ray branching ratios are presented here and compared to previous results and evaluations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effects of installation on single- and counter-rotation propeller noise

In order to understand the effects of installation on propeller noise, numerous measurements are required to define the directivity of the noise as well as the level. An experimental study was designed to map the noise radiation pattern for various single-rotation propeller (SRP) and counter-rotation propeller (CRP) installations covering + or 60 deg from the propeller disk plane and + or - 60 deg laterally. Configurations that were considered included an SRP at angle of attack and in tractor and pusher operations and a CRP. A first principles linear theory was validated for the SRP tractor operation over the angle range mentioned above. The increases in noise that arise from an unsteady loading operation such as an SRP pusher or CRP exceed 15 dB and depend on the observer location. In particular, the majority of the additional noise appears to radiate in the axial directions.