Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Type 2 and type 3 burst theory

The present state of the theory of type 3 bursts is reviewed by dividing the problem into the exciting agency, radiation source, and propagation of radiation between the source and the observer. In-situ measurements indicate that the excitors are electron streams of energy about 40 keV which are continuously relaxing. An investigation of neutralization of an electron stream indicates that n sub s is much less than 100,000 n sub e, where n sub s is the stream density and n sub e the coronal electron density. In situ observations are consistent with this result. An analysis of propagation of electrons in the current sheets of coronal streamers shows that such propagation at heights greater than 1 solar radius is impossible. The mechanisms for radiation are reviewed; it is shown that fundamental radiation at high frequencies (approximately 100 MHz) is highly beamed in the radial direction and that near the earth second harmonic radiation must be dominant. Because of beaming of the fundamental at high frequencies, it can often be quite weak near the limb so that the second harmonic is dominant. In considering propagation to the observer, the results of scattering of radiation are discussed. The present state of the theory of type 2 bursts is reviewed in the same manner as type 3 bursts.

Smith, D. F.↗

On the output of acoustical sources

Contents: (1) a theoretical basis for local power calculation; (2) source radiation in the presence of a half-plane; (3) radiation from a line source near an edge at which a Kutta condition holds; (4) radiation by a point source above a plane independence boundary; and (5) power output of a point source in a uniform flow.

Levine, H.↗

Mossbauer spectrometer radiation detector

A Mossbauer spectrometer with high efficiencies in both transmission and backscattering techniques is described. The device contains a sodium iodide crystal for detecting radiation caused by the Mossbauer effect, and two photomultipliers to collect the radiation detected by the crystal. When used in the transmission technique, the sample or scatterer is placed between the incident radiation source and the detector. When used in a backscattering technique, the detector is placed between the incident radiation source and the sample of scatterer such that the incident radiation will pass through a hole in the crystal and strike the sample. Diagrams of the instrument are provided.

Singh, J. J.↗

Silicon surface barrier detectors used for liquid hydrogen density measurement

Multichannel system employing a radioisotope radiation source, strontium-90, radiation detector, and a silicon surface barrier detector, measures the local density of liquid hydrogen at various levels in a storage tank. The instrument contains electronic equipment for collecting the density information, and a data handling system for processing this information.

James, D. T.↗

Radiation Damage Effects in Far Ultraviolet Filters and Substrates

New advances in VUV thin film filter technology have been made using filter designs with multilayers of materials such as Al2O3, BaF2, CaF2, HfO2, LaF3, MgF2, and SiO2. Our immediate application for these filters will be in an imaging system to be flown on a satellite where a 2 X 9 R(sub E) orbit will expose the instrument to approximately 275 krads of radiation. In view of the fact that no previous studies have been made on potential radiation damage of these materials in the thin film format, we report on such an assessment here. Transmittances and reflectances of BaF2, CaF2, HfO2, LaF3, MgF2, and SiO2 thin films on MgF2 substrates, Al2O3 thin films on fused silica substrates, uncoated fused silica and MgF2, and four multilayer filters made from these materials were measured from 120 nm to 180 nm before and after irradiation by 250 krads from a Co-60 gamma radiation source. No radiation-induced losses in transmittance or reflectance occurred in this wavelength range. Additional postradiation measurements from 160 nm to 300 nm indicated a 3 - 5% radiation-induced absorption near 260 nm in some of the samples with MgF2 substrates. From these measurements it is concluded that far ultraviolet filters made from the materials tested should experience less that 5% change from exposure to up to 250 krads of high energy radiation in space applications.

Keffer, Charles E.↗

Sensing device and method for measuring emission time delay during irradiation of targeted samples

An apparatus for measuring emission time delay during irradiation of targeted samples by utilizing digital signal processing to determine the emission phase shift caused by the sample is disclosed. The apparatus includes a source of electromagnetic radiation adapted to irradiate a target sample. A mechanism generates first and second digital input signals of known frequencies with a known phase relationship, and a device then converts the first and second digital input signals to analog sinusoidal signals. An element is provided to direct the first input signal to the electromagnetic radiation source to modulate the source by the frequency thereof to irradiate the target sample and generate a target sample emission. A device detects the target sample emission and produces a corresponding first output signal having a phase shift relative to the phase of the first input signal, the phase shift being caused by the irradiation time delay in the sample. A member produces a known phase shift in the second input signal to create a second output signal. A mechanism is then provided for converting each of the first and second analog output signals to digital signals. A mixer receives the first and second digital output signals and compares the signal phase relationship therebetween to produce a signal indicative of the change in phase relationship between the first and second output signals caused by the target sample emission. Finally, a feedback arrangement alters the phase of the second input signal based on the mixer signal to ultimately place the first and second output signals in quadrature. Mechanisms for enhancing this phase comparison and adjustment technique are also disclosed.

Danielson, J. D. Sheldon↗

Sensing device and method for measuring emission time delay during irradiation of targeted samples utilizing variable phase tracking

An apparatus for measuring emission time delay during irradiation of targeted samples by utilizing digital signal processing to determine the emission phase shift caused by the sample is disclosed. The apparatus includes a source of electromagnetic radiation adapted to irradiate a target sample. A mechanism generates first and second digital input signals of known frequencies with a known phase relationship, and a device then converts the first and second digital input signals to analog sinusoidal signals. An element is provided to direct the first input signal to the electromagnetic radiation source to modulate the source by the frequency thereof to irradiate the target sample and generate a target sample emission. A device detects the target sample emission and produces a corresponding first output signal having a phase shift relative to the phase of the first input signal, the phase shift being caused by the irradiation time delay in the sample. A member produces a known phase shift in the second input signal to create a second output signal. A mechanism is then provided for converting each of the first and second analog output signals to digital signals. A mixer receives the first and second digital output signals and compares the signal phase relationship therebetween to produce a signal indicative of the change in phase relationship between the first and second output signals caused by the target sample emission. Finally, a feedback arrangement alters the phase of the second input signal based on the mixer signal to ultimately place the first and second output signals in quadrature. Mechanisms for enhancing this phase comparison and adjustment technique are also disclosed.

Danielson, J. D. Sheldon↗

Critical radiation fluxes and luminosities of black holes and relativistic stars

The critial luminosity at which the outward force of radiation balances the inward force of gravity plays an important role in many astrophysical systems. We present expressions for the radiation force on particles with arbitrary cross sections and analyze the radiation field produced by radiating matter, such as a disk, ring, boundary layer, or stellar surface, that rotates slowly around a slowly rotating gravitating mass. We then use these results to investigate the critical radiation flux and, where possible, the critical luminosity of such a system in genral relativity. We demonstrate that if the radiation source is axisymmetric and emission is back-front symmetric with repect to the local direction of motion of the radiating matter, as seen in the comoving frame, then the radial component of the radiation flux and the diagonal components of the radiation stress-energy tensor outside the source are the same, to first order in the rotation rates, as they would be if the radiation source and gravitating mass were not rotating. We argue that the critical radiation flux for matter at rest in the locally nonrotating frame is often satisfactory as an astrophysical benchmark flux and show that if this benchmark is adopted, many of the complications potentially introduced by rotation of the radiation source and the gravitating mass are avoided. We show that if the radiation field in the absence of rotation would be spherically symmetric and the opacity is independent of frequency and direction, one can define a critical luminosity for the system that is independent of frequency and direction, one can define a critical luminosity for the system that is independent of the spectrum and angular size of the radiation source and is unaffected by rotation of the source and mass and orbital motion of the matter, to first order. Finally, we analyze the conditions under which the maximum possible luminosity of a star or black hole powered by steady spherically symmetric radial accretion is the same in general relativity as in the Newtonian limit.

Lamb, Frederick K.↗

Nongray radiative gas analyses using the S-N discrete ordinates method

The S-N discrete ordinates method is applied to analyze radiative heat transfer in nongray gases. Spectral correlation between the terms in the equation of transfer is considered for black or nearly nonreflecting walls. Formulations to apply the S-N method using a narrow-band or the exponential wide-band model are presented. The net radiative wall heat fluxes and the radiative source distributions are obtained for uniform, parabolic, and boundary layer-type temperature profiles, as well as for a parabolic concentration profile. The narrow- and wide-band nongray solutions are compared with gray-band approximations using the same band models. The computational speed of the gray-band approximation is obtained at the expense of accuracy in the internal fluxes and radiative source distributions. The wall radiative flux predictions by the gray-band approximation are satisfactory.

Kim, T. K.↗

Synchrotron radiation - Applications in the earth sciences

Synchrotron-radiation sources and their characteristics are overviewed along with recent synchrotron-based research on earth materials and future earth-science applications utilizing the next generation of synchrotron-radiation sources presently under construction. Focus is placed on X-ray scattering studies of earth materials (crystalline and noncrystalline) under ambient conditions, diffraction studies of earth materials at high pressures and/or temperatures, spectroscopic studies, primarily X-ray absorption spectroscopy, and spatially resolved X-ray fluorescence studies of compositional variations in earth materials. It is noted that other synchrotron-based methods, such as X-ray tomography and topography may become important in characterizing earth materials, while soft X-ray/vacuum ultraviolet radiation from synchrotron sources can be applied to problems involving the structural environments of low-atomic-number elements and the characterization of surface reactions of minerals with liquids and gases.

Bassett, W. A.↗

Hazards from High Intensity Lamps and Arcs

The principal occupational health problem generally associated with high intensity arc lamps results from exposure of the eye and skin to ultraviolet radiation. Occasionally, the chorioretinal burns are of concern. The eye is generally more susceptible than the skin to injury from high intensity optical radiation sources whether ultraviolet, visible or infrared. Recent developments in technology have shown that some high intensity optical radiation sources which have output parameters greatly different from those encountered in the natural environment present a serious chorioretinal burn hazard.

Sliney, D. H.↗

Advancements in Afterbody Radiative Heating Simulations for Earth Entry

Four advancements to the simulation of backshell radiative heating for Earth entry are presented. The first of these is the development of a flow field model that treats electronic levels of the dominant backshell radiator, N, as individual species. This is shown to allow improvements in the modeling of electron-ion recombination and two-temperature modeling, which are shown to increase backshell radiative heating by 10 to 40%. By computing the electronic state populations of N within the flow field solver, instead of through the quasi-steady state approximation in the radiation code, the coupling of radiative transition rates to the species continuity equations for the levels of N, including the impact of non-local absorption, becomes feasible. Implementation of this additional level of coupling between the flow field and radiation codes represents the second advancement presented in this work, which is shown to increase the backshell radiation by another 10 to 50%. The impact of radiative transition rates due to non-local absorption indicates the importance of accurate radiation transport in the relatively complex flow geometry of the backshell. This motivates the third advancement, which is the development of a ray-tracing radiation transport approach to compute the radiative transition rates and divergence of the radiative flux at every point for coupling to the flow field, therefore allowing the accuracy of the commonly applied tangent-slab approximation to be assessed for radiative source terms. For the sphere considered at lunar-return conditions, the tangent-slab approximation is shown to provide a sufficient level of accuracy for the radiative source terms, even for backshell cases. This is in contrast to the agreement between the two approaches for computing the radiative flux to the surface, which differ by up to 40%. The final advancement presented is the development of a nonequilibrium model for NO radiation, which provides significant backshell radiation at velocities below 10 km/s. The developed model reduces the nonequilibrium NO radiation by 50% relative to the previous model.

Johnston, Christopher O.↗

Acoustic radiation from sources convected at transonic speeds

Each supersonic jet contains a long segment of transonic flow, and it is known through acoustic experiments that the strongest noise production region is embedded in this segment. The linearized convected wave equation breaks down in the transonic regime and a nonlinear equation must be used. Amplitude, directivity, and the transonic similarity rule for noise radiation can be established through proper matching of the displacement amplitude between the source and the wave field. This paper is a first step towards establishing a general theory of transonic aeroacoustics.

Pao, S. P.↗

Doppler radar observation of thunderstorm circulation in the 1977 trip program

Storm data obtained on August 1, 1977 are examined in an attempt to interpret the relationship between lightning occurrence and the thunderstorm inner dynamics and precipitation processes. Horizontal maps are presented which indicated the position of radiation sources detected by the Lightning Detection and Ranging (LDAR) network, together with the horizontal motion fields and radar reflectivity data. Detailed inspection of these fields showed that, although radiation sources are found in the vicinity of precipitation cells, they are not located in the heavy precipitation areas, but rather on their rear side in regions where the configuration of the wind fields suggests the presence of updrafts.

Lhermitte, R. M.↗

Full-spectrum multiwavelength pyrometry for nongray surfaces

A full-spectrum (encompassing radiation on both sides of the Wien displacement peak) multiwavelength pyrometer was developed. It measures the surface temperature of arbitrary nongray ceramics by curve fitting a spectrum in this spectral region to a Planck function of temperature T. This function of T is modified by the surface spectral emissivity. The emissivity function was derived experimentally from additional spectra that were obtained by using an auxiliary radiation source and from application of Kirchhoff's law. This emissivity was verified by results that were obtained independently by using electromagnetic and solid-state theories. In the presence of interfering reflected radiation this general pyrometry improves the accuracy of the measured temperature by measuring an additional spectrum that characterizes the interfering radiation source.

Ng, Daniel↗

Absolute Radiometric Calibration of EUNIS-06

The Extreme-Ultraviolet Normal-Incidence Spectrometer (EUNIS) is a soundingrocket payload that obtains imaged high-resolution spectra of individual solar features, providing information about the Sun's corona and upper transition region. Shortly after its successful initial flight last year, a complete end-to-end calibration was carried out to determine the instrument's absolute radiometric response over its Longwave bandpass of 300 - 370A. The measurements were done at the Rutherford-Appleton Laboratory (RAL) in England, using the same vacuum facility and EUV radiation source used in the pre-flight calibrations of both SOHO/CDS and Hinode/EIS, as well as in three post-flight calibrations of our SERTS sounding rocket payload, the precursor to EUNIS. The unique radiation source provided by the Physikalisch-Technische Bundesanstalt (PTB) had been calibrated to an absolute accuracy of 7% (l-sigma) at 12 wavelengths covering our bandpass directly against the Berlin electron storage ring BESSY, which is itself a primary radiometric source standard. Scans of the EUNIS aperture were made to determine the instrument's absolute spectral sensitivity to +- 25%, considering all sources of error, and demonstrate that EUNIS-06 was the most sensitive solar E W spectrometer yet flown. The results will be matched against prior calibrations which relied on combining measurements of individual optical components, and on comparisons with theoretically predicted 'insensitive' line ratios. Coordinated observations were made during the EUNIS-06 flight by SOHO/CDS and EIT that will allow re-calibrations of those instruments as well. In addition, future EUNIS flights will provide similar calibration updates for TRACE, Hinode/EIS, and STEREO/SECCHI/EUVI.

Thomas, R. J.↗

Temporal Dependence of Chromosomal Aberration on Radiation Quality and Cellular Genetic Background

Radiation induced cancer risks are driven by genetic instability. It is not well understood how different radiation sources induce genetic instability in cells with different genetic background. Here we report our studies on genetic instability, particularly chromosome instability using fluorescence in situ hybridization (FISH), in human primary lymphocytes, normal human fibroblasts, and transformed human mammary epithelial cells in a temporal manner after exposure to high energy protons and Fe ions. The chromosome spread was prepared 48 hours, 1 week, 2 week, and 1 month after radiation exposure. Chromosome aberrations were analyzed with whole chromosome specific probes (chr. 3 and chr. 6). After exposure to protons and Fe ions of similar cumulative energy (??), Fe ions induced more chromosomal aberrations at early time point (48 hours) in all three types of cells. Over time (after 1 month), more chromosome aberrations were observed in cells exposed to Fe ions than in the same type of cells exposed to protons. While the mammary epithelial cells have higher intrinsic genetic instability and higher rate of initial chromosome aberrations than the fibroblasts, the fibroblasts retained more chromosomal aberration after long term cell culture (1 month) in comparison to their initial frequency of chromosome aberration. In lymphocytes, the chromosome aberration frequency at 1 month after exposure to Fe ions was close to unexposed background, and the chromosome aberration frequency at 1 month after exposure to proton was much higher. In addition to human cells, mouse bone marrow cells isolated from strains CBA/CaH and C57BL/6 were irradiated with proton or Fe ions and were analyzed for chromosome aberration at different time points. Cells from CBA mice showed similar frequency of chromosome aberration at early and late time points, while cells from C57 mice showed very different chromosome aberration rate at early and late time points. Our results suggest that relative biological effectiveness (RBE) of radiation are different for different radiation sources, for different cell types, and for the same cell type with different genetic background at different times after radiation exposure. Caution must be taken in using RBE value to estimate biological effects from radiation exposure.

Lu, Tao↗

Analysis of diffential absorption lidar technique for measurements of anhydrous hydrogen chloride from solid rocket motors using a deuterium fluoride laser

An active optical technique (differential absorption lidar (DIAL)) for detecting, ranging, and quantifying the concentration of anhydrous HCl contained in the ground cloud emitted by solid rocket motors (SRM) is evaluated. Results are presented of an experiment in which absorption coefficients of HCl were measured for several deuterium fluoride (DF) laser transitions demonstrating for the first time that a close overlap exists between the 2-1 P(3) vibrational transition of the DF laser and the 1-0 P(6) absorption line of HCl, with an absorption coefficient of 5.64 (atm-cm) to the -1 power. These measurements show that the DF laser can be an appropriate radiation source for detecting HCl in a DIAL technique. Development of a mathematical computer model to predict the sensitivity of DIAL for detecting anhydrous HCl in the ground cloud is outlined, and results that assume a commercially available DF laser as the radiation source are presented.

Bair, C. H.↗