Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOACTIVE PARTICLE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

In situ liquid SIMS analysis of uranium oxide

Trace analysis of nuclear materials in solid particles collected in the environment or particles in liquid slurry generated in nuclear material manufacturing processes can pinpoint elemental, organic, and isotopic signatures of nuclear fuel cycle activities and processes. Such information can support nuclear safeguards programs by increasing our ability to detect undeclared nuclear materials, routine activities for safeguarding at declared facilities, and illicit activities. However, trace radioactive material analysis in liquids and slurries is challenging using bulk approaches. For example, one drawback of sensitive analysis such as inductively coupled plasma mass spectrometry (ICP-MS) is that sample is consumed or destroyed as a result of the technical approach. We developed a vacuum compatible microfluidic interface to enable surface analysis of liquids and liquid-solid interactions using time-of-flight secondary ion mass spectrometry (ToF-SIMS). In this work, we illustrate initial results of liquid standards containing uranium using in situ liquid SIMS. Specifically a series of diluted uranium standards used for ICPMS analysis were studied and the limit of detection was estimated. Since the liquid SIMS analysis is almost nondestructive, the same sample can be analyzed by other more destructive approaches afterwards or saved for future references. Consequently, multimodal analysis is possible. Our results demonstrate that in situ liquid SIMS can be used as a new approach to analyze radioactive materials in liquid and slurry forms of relevance to the IAEA safeguards missions.

In situ liquid ToF-SIMS, uranium, limit of detecti↗

Radiation Protective Coveralls for Fermilab’s SPOT Robot

Fermilab’s Accelerator Division recently purchased a SPOT robot from Boston Dynamics to be used to automatically measure the residual radiation in the beamline tunnels. Fermilab will work with the College of DuPage Fashion Studies Department to design and develop a prototype Tyvek-garments (coveralls and booties) that can be easily used and replicated by the Fermilab operators to shield the SPOT robot from collecting radioactive dust while deployed.

43 PARTICLE ACCELERATORS↗

Production of Precursor Materials for the Development of Iron-Based Superconductor (IBS) Wire

The objective of the activities under this Annex is to address the extrinsic Jc limitations uncovered in pioneering work. In order to engineer the defects pinning landscape charged particle irradiations experiments on bulk samples, different doping and chemical additions will be performed at different National facilities (Test Beam Facility at Fermilab; Linac Isotope Producer at Brookhaven National Laboratory; Integrated Biology Laboratory at University of Wisconsin-Madison; Facility for Rare Isotope Beams at Michigan State University). The samples will be produced at ENEA by different techniques. Magnetization and advanced microscopy measures will be performed at Fermilab. After irradiation, depending on the level of radioactivity, the samples will be tested at Fermilab or where it is possible to measure radioactive materials as University of Wisconsin-Madison.

43 PARTICLE ACCELERATORS↗

Real-Time Radiological Source Term Estimation for Multiple Sources in Cluttered Environments

A particle filter algorithm is presented to estimate the position, strength, and cardinality of an unknown number of radioactive point sources in an obstacle-rich environment using count measurements. The algorithm addresses gaps in the prior literature by incorporating two novel elements. The first is a precomputation step in which local terrain and obstacle data is processed to compute attenuation kernels throughout the search area. This enables rapid estimation performance in obstacle-rich environments as measurements are gathered. The second novel feature is a dynamic particle allocation technique in which the number of particles is adjusted in real time to meet convergence goals. This feature allows the algorithm to scale more efficiently to scenarios with a larger number of sources. Furthermore, a series of computational experiments using simulated data demonstrates the algorithm’s performance in a cluttered environment with up to eight sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Real-Time Radiological Source Term Estimation for Multiple Sources in Cluttered Environments

A particle filter algorithm is presented to estimate the position, strength, and cardinality of an unknown number of radioactive point sources in an obstacle-rich environment using count measurements. The algorithm addresses gaps in the prior literature by incorporating two novel elements. The first is a precomputation step in which local terrain and obstacle data is processed to compute attenuation kernels throughout the search area. This enables rapid estimation performance in obstacle-rich environments as measurements are gathered. The second novel feature is a dynamic particle allocation technique in which the number of particles is adjusted in real time to meet convergence goals. This feature allows the algorithm to scale more efficiently to scenarios with a larger number of sources. A series of computational experiments using simulated data demonstrates the algorithm’s performance in a cluttered environment with up to eight sources.

Kemp, Samuel↗

AI-assisted transport of radioactive ion beams

Beams of radioactive heavy ions allow researchers to study rare and unstable atomic nuclei, shedding light into the internal structure of exotic nuclei and on how chemical elements are formed in stars. However, the extraction and transport of radioactive beams rely on time-consuming expert-driven tuning methods, where hundreds of parameters are manually optimized. Here, in this study, we introduce a system that employs Artificial Intelligence (AI), specifically utilizing Bayesian Optimization, to assist in the transport process of radioactive beams. We apply our methodology to real-life scenarios showing advantages when compared with standard tuning methods. This AI-assisted approach can be extended to other radioactive beam facilities around the world to improve operational efficiency and enhance scientific output.

43 PARTICLE ACCELERATORS↗

Water reactive polyurethane grouting for deep vadose zone contaminant immobilization

Contaminants in the deep vadose zone (DVZ) pose a long-term threat to groundwater, human health, and the environment. Polyurethane grouting is a type of chemical grouting that is potentially advantageous in immobilizing contaminants in DVZs. Polyurethane resin has low viscosity that makes it feasible to penetrate and fill the pore space between fine particles. Here, in this study a series of laboratory pressure grouting and leaching tests were conducted to simulate and assess the effectiveness of polyurethane grouting for immobilizing contaminants in DVZs. Soil with fine particles was prepared with 127 I (as iodide) that served as a non-radioactive surrogate for radioactive 129 I. After grouting and curing, leaching tests were used to measure and compare contaminant diffusivity and leachability index values. Additionally, changes in porosity and saturated hydraulic conductivity of grouted soil were measured. X-Ray Computer Tomography (XCT) results showed that the cured polyurethane was distributed nearly homogeneously and approximately half of the voids were filled with cured polyurethane. Grouting reduced the saturated hydraulic conductivity of soil by 37 %. The effective diffusivity decreased by more than 80 % as compared with the ungrouted soil. The leachability index of the grouted soil was 6.5; meeting the criteria established by the U.S. Nuclear Regulatory Commission (NRC) standard. The results obtained in this study provide a valuable assessment of polyurethane grouting for iodide immobilization in the DVZ and indicate this approach may be a viable method for contaminant remediation in DVZ soils.

Contaminant Diffusion↗

Development of a pulsed, variable-energy positron beam for atomic scale defect studies

Positron annihilation spectroscopy provides a sensitive means of non-destructive characterization of materials, capable of probing single atom vacancies in solids with 10 –7 sensitivity. Here, in this work, we detail the development of a magnetically guided, variable energy, pulsed positron beam designed to conduct depth-dependent defect studies in metals, semiconductors, and dielectrics, which will be the first of its kind in the United States. The design of the target stage provides capabilities for measurements during in situ annealing up to 800 °C and incorporates a new approach to minimize the background due to energetic backscattered positrons. The developed beam at Bowling Green State University provides a powerful tool for characterization of thin films, devices, and ion irradiated materials.

47 OTHER INSTRUMENTATION↗

Sources of Conservatism in Making Corrective Action Decisions at the NNSS - 20477

During the course of closing nuclear testing release sites at the Nevada National Security Site (NNSS) under the Federal Facility Agreement and Consent Order (FFACO) using the Risk-Based Corrective Action (RBCA) evaluation process, conservative assumptions and estimates were used in many phases of the work. These assumptions and estimates were agreed to during Data Quality Objective (DQO) meetings and published in the FFACO documents. However, the potential cumulative effect of these multiple sources of conservatism was not evaluated. The RBCA process ensures that corrective action decisions minimize the risk of making Type I errors (not applying corrective action to areas that exceed action levels) at the expense of making Type II errors (applying corrective action to areas that do not exceed action levels). Rather than fully characterizing the spatial distribution of contaminants throughout each site, the RBCA process uses a bounding methodology that conservatively estimates spatial boundaries beyond which contamination is not present that exceed corrective action levels. This process accepts that these boundaries may encompass areas that do not exceed corrective action levels and, therefore, may be somewhat larger than for fully characterized sites. This is justified at sites where the reduction in investigation costs are more than any potential increase in corrective action costs. To minimize the risk of making Type I errors, conservatism was used throughout the process. This study documents the many sources of conservatism used in the RBCA process. Conservatism was used in the RBCA process in determining potential receptors, determining action levels, collecting samples, converting sample results into receptor dose, and accounting for uncertainty. This provides decision-makers with a high level of confidence that unacceptable risk to receptors will not result from exposure to residual contamination outside the corrective action boundaries. However, it does not provide an estimate of the actual extent of areas exceeding action levels. This study provides an evaluation of the effects of compounding conservatism on RBCA process decisions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimating a protection factor from homemade facemasks for Los Alamos radioactive aerosols

The Los Alamos National Laboratory has required usage of facemasks “whenever interacting with or near others." The present document estimates the respiratory protection factor of homemade facemasks to be 1.4 and 1.2 for aerosol particles, below and above 0.3 μm diameter, respectively. This includes an estimated leakage of 70% and 52% for aerosol particles below and above 0.3 μm diameter, respectively.

61 RADIATION PROTECTION AND DOSIMETRY↗

Search for Dark Matter Induced Deexcitation of 180 Ta m

Weak-scale dark matter particles, in collisions with nuclei, can mediate transitions between different nuclear energy levels. In particular, owing to sizeable momentum exchange, dark matter particles can enable de-excitation of nuclear isomers that are extremely long lived with respect to regular radioactive decays. In this paper, we utilize data from a past experiment with 180 Ta m to search for γ-lines that would accompany dark matter induced de-excitation of this isomer. Non-observation of such transitions above background yields the first direct constraint on the lifetime of 180 Ta m against DM-initiated transitions: T 1/2 > 1.3 × 10 14 a at 90% C.I. Using this result, we derive novel constraints on dark matter models with strongly interacting relics, and on models with inelastic dark matter particles. Existing constraints are strengthened by this independent new method. As a result, the obtained limits are also valid for the Standard Model γ-decay of 180 Ta m .

150 ≤ A ≤ 189↗

Measurement of ambient radon progeny decay rates and energy spectra in liquid argon using the MicroBooNE detector

We report measurements of radon progeny in liquid argon within the MicroBooNE time projection chamber (LArTPC). The presence of specific radon daughters in MicroBooNE’s 85 metric tons of active liquid argon bulk is probed with newly developed charge-based low-energy reconstruction tools and analysis techniques to detect correlated Bi 214 − Po 214 radioactive decays. Special datasets taken during periods of active radon doping enable new demonstrations of the calorimetric capabilities of single-phase neutrino LArTPCs for β and α particles with electron-equivalent energies ranging from 0.1 to 3.0 MeV. By applying Bi 214 − Po 214 detection algorithms to data recorded over a 46-day period, no statistically significant presence of radioactive Bi 214 is detected, and a limit on the activity is placed at < 0.35 mBq / kg at the 95% confidence level. This bulk Bi 214 radiopurity limit—the first ever reported for a liquid argon detector incorporating liquid-phase purification—is then further discussed in relation to the targeted upper limit of 1 mBq / kg on bulk Rn 222 activity for the DUNE neutrino detector. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of online pulse-finding algorithms for the Mu2e Stopping Target Monitor and an evaluation of the signal to background ratio for the Mu2e stopped-muon rate determination

This thesis presents a determination of the acceptance of the Mu2e Stopping Target Monitor (STM) detector for both signal and background events. The rate of X-rays of a specific energy in the STM is used to determine the rate of stopped muons in the aluminium stopping target, which is used as the normalisation for all Mu2e measurements, particularly the branching ratio for a charged lepton flavour violating (cLFV) process. The acceptance for the 347\,keV $2p-1s$ aluminium signal X-ray is determined to be $(8.03 \pm 0.05) \times 10^{-10}$\,cm$^{-2}$ and the acceptance for the background photons (at 347\,keV) to be $(3.19 \pm 0.21) \times 10^{-8}$\,cm$^{-2}$. This results in a signal-to-background ratio of approximately two which is significantly higher than had previously been estimated. These signal-to-background rates are used to determine the time required to achieve a statistical uncertainty of 10\% on the number of 347\,keV X-rays as a function of the detector resolution and back ground rate. For a resolution of 2\,keV, and the background rate determined in this thesis, approximately one minute of data is required. The three corrections needed to be applied to the measured 347\,keV rate to determine the rate of stopped muons are also determined and potential sources of bias arising from the background shape, background fit range and energy calibration are investigated and found to be insignificant. The raw energy of the particles in the STM detector comes from a 16-bit ADC digitising at $\sim 300$\,MHz. It is not possible to store all the raw digitisations and online algorithms have been developed to rapidly select pulses in the detector and reconstruct their energy. The performance of these algorithms has been characterised with simulated data as a function of detector rate and resolution and optimum operating points for the algorithms have been defined. The integrity of the algorithms has also been demonstrated and characterised on test-beam data at high r ates and with radioactive sources at low rates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Source characterization of a detector for heavy and superheavy nuclei

A new focal plane detector system for the Berkeley Gas-filled Separator (BGS) was designed, constructed, and tested offline with various α-decay and conversion-electron sources. The SuperHeavy RECoils (SHREC) detector comprises sets of double-sided silicon strip detectors arranged in an open-faced cuboid geometry. Alongside the detector upgrade new digital data acquisition electronics have been commissioned offline. This setup aims to detect separated recoiling heavy and superheavy nuclei as well as their correlated radioactive decay paths with improved energy resolution and overall sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Use of Silver Chloride Injection in Remediation of Iodine-129 by In Situ Capture as Silver Iodide at the F-Area Seepage Basin - 20225

The Savannah River Site (SRS) produced tritium, plutonium, and special nuclear materials for national defense, medicine, and the space programs. As part of operations, the F-Area Seepage Basins operated until 1988 for the disposition of deionized acidic wastewater from the F Separations Facility. The wastewater contained dilute nitric acid and low concentrations of non-radioactive metals, and radionuclides, with the major isotopes being Cs-137, Sr-90, U-235, U-238, Pu-239, Tc-99, I-129, and tritium. The seepage basins were closed in 1988 and backfilled and capped by 1991. The groundwater emanating from beneath the closed and capped seepage basins is acidic and contains elevated levels of both chemical and radiological contaminants. Releases from the groundwater plumes sourced from the F-Area Seepage Basins have impacted the water quality of Fourmile Branch, which is a small tributary to the Savannah River, a regional water source. A large pump-and-treat system was constructed in 1997 and operated until 2003 in an attempt to capture the releases to Fourmile Branch. The system in F Area and a similar system in H Area were expensive (∼$1.3 M/month) to operate and produced large quantities of radioactive waste, with concentrations of I- 129 too high to be disposed of at the SRS. In 2004, SRS replaced pump-and-treat with a funnel and gate system that along with operation of a base injection system at the gates reduces the flux of contaminants to the wetlands adjacent to Fourmile Branch. The alkaline solution injected into the aquifer neutralizes the acidic plume and immobilizes many of the cationic constituents. However, base injection is not effective in managing the release of iodine-129, an anionic contaminant. To address iodine-129 SRS and the Savannah River National Laboratory developed an in situ technology that uses ultra-fine ground silver chloride (AgCl) as an injectable capture medium for the sequestration of iodine-129. The AgCl amendment has a very small particle size and is designed to be injected into the contaminated aquifer to capture iodine-129. Dissolved iodine-129 forms a stable and highly insoluble solid (silver iodide) upon contact with AgCl. Laboratory studies, a field scale pilot test (2009), and three deployments (2011, 2015 and 2019) of AgCl have been successfully performed at the F-Area Seepage Basins. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Toward a neutrino-limited dark matter search with crystalline xenon

Experiments searching for weakly interacting massive particle dark matter are now detecting background events from solar neutrino-electron scattering. However, the dominant radioactive background in state-of-the-art experiments such as LZ and XENONnT is beta decays from radon contamination. In spite of careful detector material screening, radon progenitor atoms are ubiquitous and long-lived, and radon is extremely soluble in liquid xenon. We propose a change of phase and demonstrate that crystalline xenon offers more than a factor × 500 exclusion against radon ingress, compared with the liquid state. This level of radon exclusion would allow crystallized versions of existing experiments to probe spin-independent cross sections near 10 − 47 cm 2 in roughly 11 years, as opposed to the 35 years required otherwise. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DarkSide-20k sensitivity to light dark matter particles

The dual-phase liquid argon time projection chamber is presently one of the leading technologies to search for dark matter particles with masses below 10 GeV c$^{−2}$. This was demonstrated by the DarkSide-50 experiment with approximately 50 kg of low-radioactivity liquid argon as target material. The next generation experiment DarkSide-20k, currently under construction, will use 1,000 times more argon and is expected to start operation in 2027. Based on the DarkSide-50 experience, here we assess the DarkSide-20k sensitivity to models predicting light dark matter particles, including Weakly Interacting Massive Particles (WIMPs) and sub-GeV c$^{−2}$ particles interacting with electrons in argon atoms. With one year of data, a sensitivity improvement to dark matter interaction cross-sections by at least one order of magnitude with respect to DarkSide-50 is expected for all these models. A sensitivity to WIMP–nucleon interaction cross-sections below 1 × 10$^{−42}$ cm$^{2}$ is achievable for WIMP masses above 800 MeV c$^{−2}$. With 10 years exposure, the neutrino fog can be reached for WIMP masses around 5 GeV c$^{−2}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark matter detection capabilities of a large multipurpose Liquid Argon Time Projection Chamber

Liquid Argon Time Projection Chambers are planned to comprise a central role in the future of the U.S. High Energy Physics neutrino program. In particular, this detector technology will form the basis for the 40 kton Deep Underground Neutrino Experiment (DUNE) . Here in this paper we take as a starting point the dual phase far detector design proposed by the DUNE experiment and ask what changes are necessary to allow one of the four 10 kt modules to be sensitive to heavy Weakly Interacting Massive Particle (WIMP) dark matter. We show that with control over backgrounds and the use of low radioactivity argon, which may be commercially available on that timescale, along with a significant increase in light detection, one DUNE-like module gives a competitive WIMP detection sensitivity, particularly above a dark matter mass of 100 GeV.

47 OTHER INSTRUMENTATION↗