Search NASA⌕ Search

SEARCH · Search NASA

Results for “REACTOR CONTROL SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Development of a systematic approach for safety assessment of PLD based equipment of I and C systems - 354

Nuclear power plants (NPPs) increasingly apply digital equipment for instrumentation and control (I and C) systems. During the life cycle of NPPs the operators, designers and manufactures are facing the need to replace or upgrade obsolete equipment or to implement new digital I and C systems. A relatively new challenge in this area is the deployment of programmable logic devices (PLDs) for the equipment of I and C systems. Regulatory approval for safety and safety related I and C systems demands confirmation of evidence that design as well as verification and validation (V and V) processes have ensured that the application of new equipment will fulfil safety and reliability requirements and its intended design function. The objective of the recent research project of GRS is developing a systematic approach for the assessment of PLD-based equipment in safety and safety-related I and C systems regarding the fulfilment of regulatory requirements and identification of undesired failure effects. A generic approach for the safety-oriented assessment of PLD-based equipment has been developed, based on the principles of a Plan-Do-Check-Act (PDCA) cycle. The approach comprises planning of the assessment, predefined analysis steps and methodologies, as well as required input information, criteria for decision making process, the tasks concerning identification of improvement potential and determining documentation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Qualified display system architecture - 246

There is a need in the nuclear industry for a Qualified Display System (QDS) architecture as described in this paper. The function of the QDS is to process and display Regulatory Guide 1.97 post accident monitoring parameters. The QDS is implemented on the Lockheed Martin Field-Programmable Gate Array (FPGA) based Nuclear Protection and Control (NuPAC) digital platform, coupled with a Qualified Display Controller (QDC) and a Safety Display Unit (SDU). The QDS is designed to meet the requirements of IEEE 603-1991 (endorsed by Regulatory Guide 1.153, Rev. 1), IEEE 497-2002 (endorsed by Regulatory Guide 1.97, Rev. 4), and IEEE 7-4.3.2- 2003 (endorsed by Regulatory Guide 1.152, Rev. 3). The QDS is designed with flexibility such that it can be implemented in an advanced reactor design, Small Modular Reactor (SMR) with any cooling medium, or digital upgrade project for an operating nuclear plant. The QDS has four independent and redundant divisions. Each division has five layers in the architecture: Process variable input signals; Process Protection Logic (PPL); Algorithm Logic (AL), Interface Panel (IP); and Safety Display Unit (SDU). The QDS meets the following design criteria: redundancy, independence, predictability and repeatability, and diversity capability. The QDS architecture also meets the simplicity design principle. The QDS architecture design provides flexibility in the implementation in a plant. The QDS can be implemented in the design of a new advanced plant or as a digital upgrade in an operating plant. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Practical applications of model checking in the finnish nuclear industry - 281

Model checking is a powerful, formal, computer-assisted verification method that can be used to prove that a model of a (hardware or software) system fulfills stated properties. When used right, model checking can prove the correctness of instrumentation and control (I and C) system application logic, be it a software or a field-programmable gate array (FPGA) based design. The verified properties can also address unwanted functionality, making model checking a very effective method for analyzing spurious actuation. Despite the benefits, model checking is still not widely adopted in the verification of I and C systems, one exception being the Finnish nuclear industry. Since 2008, VTT has applied model checking in practical customer work related to the Olkiluoto 3 EPR, Loviisa 1 and 2 VVER-440, and Hanhikivi 1 AES-2006 nuclear power plants, on commission from either the regulator or the utilities. In this paper, we look at how the method has been used in each of these three projects. We also introduce a user-friendly, graphical modelling tool called MODCHK. We then present an overall view of the design issues detected during nine years of customer work, and one practical example. The 100% coverage means that the design errors that are found often relate to scenarios that are otherwise hard to account for (e.g., exact timing of events, or improper operator actions). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

V and V techniques for FPGA-based I and C systems - How do they compare with techniques for microprocessors? - 355

We compare verification and validation (V and V) techniques for FPGA and microprocessor-based instrumentation and control (I and C) systems from the point of view of standards compliance, an approach based on behavioural properties, and the analysis of vulnerabilities. We found that the non-technology-specific elements of the standards considered are very similar. Differences are more marked when considering behavioural properties and vulnerabilities: the amount of effort required and confidence level obtained depend on a number of properties of the particular design under verification. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Real-Time Quantitative Safety Evaluation Method for Nuclear Power Plants

Human operators involved with large process control systems such as nuclear power plants (NPPs) perform significant roles in the operation of systems. In this reason, deficiencies in human factors such as poor HSI (Human System Interface) design, procedure, and training, are significant contributing factors to NPPs incidents and accidents. In this regard, many kinds of studies including human reliability analysis (HRA), operation support system, automation, have been conducted in order to reduce human errors. Among these fields of studies, automation has its own specialty since it mainly focuses on eliminating the human error-inducing tasks to reduce human error, while other topics are primarily focusing on reducing human error by aiding human operators during operation. It is commonly believed that replacing human operators to the automated system would guarantee greater efficiency, lower workloads, and fewer human errors. However, these beliefs are not always true in large and complex systems such as NPP, since excessive automation can generate new roles for human operators, change human operators' activities in unexpected ways, and inducing 'out-of-the-loop' (OOTL) problem. Especially, although human error probability drastically increases during abnormal situations in NPP due to overload of information, high workload, and short time available for diagnosis, automation is not actively adopted since conventional machine learning techniques are neither capable nor reliable to handle overwhelmingly complex abnormal situations in NPP. Recently, newly developed 'deep learning' techniques have been actively applied to many fields, and some of these studies proved that the artificial intelligences (AI) based on deep learning techniques show better performance than that of human being. In 2015, deep Q-network (DQN) which is one of the deep learning techniques was developed and applied to train AI that automatically plays various Atari 2800 games, and this AI surpassed the human-level playing in many kind of games. Also in 2016, 'AlphaGo', which was developed by 'Google Deepmind' based on deep learning technique to play the game of Go, was defeated Se-dol Lee who is the World Go champion with score of 4:1. In the point of view that the game of Go is considered as one of the challenging area in machine learning field, it is verified that these new machine learning techniques can perform well, even better than the human being in high-complexity tasks. Previously, most of AI applications in nuclear field were focusing on supporting human operators' tasks such as diagnosis and decision making by rapid classification and prediction, based on fixed training data sets. However, it is expected that AI can be applied to solve more complicated problems (i.e. automation during abnormal states in NPP) by adopting advanced machine learning methodologies. In order to apply the automation system in NPP, firstly it is needed to evaluate the status of the plant quantitatively in real-time, since the information about which state is better (i.e. safe) or worse (i.e. unsafe) is essential for training properly working automation AI. Currently, there are several methodologies for NPP safety evaluation such as probabilistic safety assessment (PSA), safety performance indicator (SPI). However, existing methodologies are not feasible for development of automated system since they are not capable for the cases which are not included in the underlying model, not able to consider delicate changes in the NPP, and hard to evaluate in real-time. Therefore, development of new NPP safety evaluation methodology which can cover previously mentioned requirements is needed to conduct the study on NPP automation further. In this study, the concept of early warning score (EWS) in medical field was adopted to develop the methodology which can evaluate the safety level of the NPP quantitatively and in real-time. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of cyber security test scenario for non-safety display system - 226

In order to test the cyber security of NPP related to safety, the results of probabilistic safety assessment were used. The fault tree (FT) is used to reflect the impact of the cyber-attack on the operator. The cyber security test should be performed focusing on the scenario derived from the FT. The concept of a security case has been introduced. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An Approach for Assessing Consequences of Potential Supply Chain and Insider Contributed Cyber Attacks on Nuclear Power Plants

This paper provides an approach for developing potential attacks on I and C systems of NPPs and assessing their consequences. An important concept is that the NPPs were not designed to cope with Stuxnet-type of attacks (and any other cyber attacks). That is, the plants were only designed for design basis accidents. The safety margins and redundancies built in the design are all based on design basis accidents. They may be helpful in mitigating cyberattacks, but may not be adequate.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Coordinated control design and verification of the HTR-PM plant - 18485

Through multi-modular scheme, i.e. the superheated steam flows produced by multiple MHTGR-based nuclear supplying system (NSSS) modules are combined together to drive a common thermal load, the inherent safety feature of MHTGR can be applicable to the large-scale nuclear plants at any desired power ratings. Since the plant power control technique of classical single-modular plants cannot be directly applied to multi-modular plants, it is necessary to develop the power control method of the multi-modular plants. In this paper, the plant power control strategy of the two-modular HTR-PM plant, i.e. the first under-constructed multi-modular high temperature gas-cooled nuclear plant in the world is given, which includes both the feedback loops and control algorithms. Then, the control strategy is verified through numerical simulation, and the simulation results in the cases of plant power step and ramp show the satisfactory performance of this control strategy. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Condition monitoring and false alarm reducing of sensors in NPP - 222

With more and more application of digital I and C systems in nuclear power plants (NPP), more and more sensors are also required. Large amount of sensors really can make contribution to the condition monitoring of systems and equipment in NPP, whereas the heavy use also increases the malfunction risk of sensor self. Therefore the reliability and effectiveness of sensors must be guaranteed first. Thus the condition of sensors should be monitored first in a NPP. Since the precise mathematical models of sensors in complex systems are relative difficult to establish, however quantity of operating data can be easily obtained due to the wide application of digital I and C systems, thus this article adopts principal component analysis (PCA) to carry out condition monitoring for sensors. The PCA model developed for sensors is proved to be effective with operating data acquired from a real NPP. It can detect and isolate the fault when an artificial fault is imposed to the normal data. Then the monitoring results are further processed by another control limit (second confidence limit) besides T 2 and Q statistics (first confidence limit) in PCA. The value of second confidence limit is calculated based on the probability statistics of T 2 and Q statistics. And simulation tests show that the application of the second confidence limit can greatly reduce false alarms in the PCA model and the model performance can be greatly improved with the application of false alarms reducing method. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effects of adaptive automation on operator-system performance - 103

Adaptive automation (AA) is the dynamic, real-time change in the degree of automation in response to situational changes. AA systems are being developed in many industries, including for nuclear power plant applications. AA is a promising means of mitigating human performance issues that often arise in highly automated systems. The purpose of this Nuclear Regulatory Commission study was to characterize important AA design features, define the effects of AA on performance, examine the human factors engineering (HFE) guidance available to design and evaluate AA systems, and identify research and development needs. In general, we found that AA improves task performance and situation awareness (SA) while managing workload. Although the research is limited, AA also supports operator recognition of automation failure and recovery. Research on human-system interfaces has identified principles showing promise for supporting SA, including failure detection, and limiting workload. Research further suggests that AA systems are both more effective, and less disruptive and distracting, when they follow rules of interaction similar to those used by human crewmembers. Our general conclusion about the HFE guidance available to designers and reviewers is that it is limited and has not kept pace with automation technology. We discuss several research and development needs that will help support a better understanding of where and how AA should be used and support the development of more comprehensive guidance for AA safety reviews. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Recent results from a testbed for the reliability of the digital instrumentation and control systems and cybersecurity in nuclear power plants - 392

Transition from analog to digital instrumentation and control systems requires a systematic study of the modifications, and assessment of their reliability. Such studies are often carried out on a test bed. The test bed developed earlier includes a commercially available triple modular redundant (TMR) programmable logic controller (PLC) for testing not only the reliability of the digital I and C but also the cyber-security of the system during plant operation. This paper reports results of our preliminary analyses carried out using the test bed following the injection of faults mimicking faulty sensors. The fault injection tool generates faulty signals in single or multiple sensors located in the primary loop. These scenarios studied under steady-state operation conditions simulate a bad sensor, a cut wire, noise, etc. The faults injected can lead to information being displayed in the main control room (MCR) to not match the conditions in the plant. In addition to a fault injection module, a result analyzer module is also a part of this testbed. Operator actions can be based on information displayed in the MCR, or they can be informed by the result analyzer. Potential operator actions following these single- or multiple faulty signals are assessed. It is concluded that the result analyzer in some cases can be helpful in guiding operators to make the right decisions. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

On-line monitoring of I and C transmitters and sensors for calibration verification and response time testing was successfully implemented at ATR - 326

The Advanced Test Reactor (ATR) has always had a comprehensive procedure to verify the performance of its critical transmitters and sensors, including RTDs, and pressure, level, and flow transmitters. These transmitters and sensors have been periodically tested for response time and calibration verification to ensure accuracy. With implementation of on-line monitoring techniques at ATR, the calibration verification and response time testing of these transmitters and sensors are verified remotely, automatically, hands off, include more portions of the system, and can be performed at almost any time during process operations. The work was done under a DOE funded SBIR project carried out by AMS. As a result, ATR is now able to save the manpower that has been spent over the years on manual calibration verification and response time testing of its temperature and pressure sensors and refocus those resources towards more equipment reliability needs. More importantly, implementation of OLM will help enhance the overall availability, safety, and efficiency. Together with equipment reliability programs of ATR, the integration of OLM will also help with I and C aging management goals of the Department of Energy and long-time operation of ATR. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modelling I and C systems with relays for simulation, adapting CIM standards - 243

As the nuclear power plants are in operation for many years, a main issue is to integrate simulation activities in parallel to the present I and C design process in order to limit impacts on current operating I and C engineering process and commissioning activities. The objective is to keep the existing I and C data and diagrams format. EDF chose to build an intermediate file independent of the tool used for simulation to exchange and store data. This file has been created adapting CIM standards (IEC 61968-13 and IEC 61970-301). It is an XML file built according to an RDF schema. CIM standards are intended to model transport or distribution electrical networks and used to facilitate system integration and information exchanges. We chose to adapt CIM to model EDF electromechanical relay circuitries in order to re-use all methods and tools developed around CIM standards such as RDF schema and RiseClipse, an open source tool developed by EDF and SUPELEC engineering school that will be used to verify exported I and C data according to a data model and to EDF engineering rules. This paper will describe the ongoing project on simulation in parallel to current I and C design process, focusing on how I and C electromechanical relays data are modelled based on CIM standards, and what benefits that model provides to I and C Verification and Validation activities. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparative requirements, stakes and deployment for 2 ongoing major I and C modernization projects (NPIC2017 - 19956) - 293

Rolls-Royce Civil Nuclear I and C is deploying its safety and safety-related technologies in more than 80 plants, in particular in France, China and Finland. This paper gives an overview of the context (including regulatory requirements), stakes, objectives and progress as well as of the technology and technical solutions being deployed in two representative I and C modernization examples: - The modernization of 2 VVER plants in Loviisa (Finland); - Modernization of 20 PWR plants for EDF in France. While there are many similarities: a tight schedule, the cohabitation of new and old systems, mostly from third parties, both digital and analog, and some additional improvements and modifications, the context of these two projects is very different: - Fleet Vs 'isolated' plants approach; - Different types of reactors (PWR Vs VVER); - Involvement of a large utility and Integrator (EDF/Areva) Vs a smaller Utility (Fortum); - Specific safety requirements from well recognized safety authorities (French ASN and Finnish STUK); - Implementation of specific safety functions with the same Safety platform (Rolls-Royce Spinline{sup R}). From this comparison we will extract the main challenges faced, the solutions implemented and some key success factors for such I and C modernizations. In particular: the licensing, the importance of a proven and adaptable safety platform and the often overlooked aspects such as communication and joint working-organization with all the stakeholders: customer, supply chain and safety authorities. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Selecting a radiation tolerant piezoelectric material for nuclear reactor applications

Bringing systems for online monitoring of nuclear reactors to fruition has been delayed by the lack of suitable ultrasonic sensors. Recent work has demonstrated the capability of an AlN sensor to perform ultrasonic evaluation in an actual nuclear reactor. Although the AlN demonstrated sustainability, no loss in signal amplitude and d{sub 33} up to a fast and thermal neutron fluence of 1.85 Multiplication-Sign 1018 n/cm{sup 2} and 5.8 Multiplication-Sign 1018 n/cm{sup 2} respectively, no formal process to selecting a suitable sensor material was made. It would be ideal to use first principles approaches to somehow reduce each candidate piezoelectric material to a simple ranking showing directly which materials one should expect to be most radiation tolerant. However, the complexity of the problem makes such a ranking impractical and one must appeal to experimental observations. This should not be of any surprise to one whom is familiar with material science as most material properties are obtained in this manner. Therefore, this work adopts a similar approach, the mechanisms affecting radiation tolerance are discussed and a good engineering sense is used for material qualification of the candidate piezoelectric materials.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Procedure design of F and B operation and its impact on the risk of a nuclear power plant - 168

A feed and bleed (F and B) operation is an operator's emergency task to remove core heat from a reactor coolant system by bleeding coolant from the pressurizer, and feeding makeup water through safety injection systems under the loss of all feedwater condition. Even though the F and B operation is an important task having a significant impact on the risk of a nuclear power plant, there is a high uncertainty regarding its modeling and analysis in a PSA. This paper introduces a study on the design of an operational strategy for an F and B operation and its impact on the risk of a nuclear power plant in Korea. An intensive support analysis was conducted to understand the plant behavior and revise the success criteria for the HRA of the F and B operation. A human performance analysis on the emergency tasks was also conducted using a training simulator to generate the operator's performance time for the F and B operation. We revised the PSA model and updated the risk of the reference plant, which shows that the risk of the revised model is much higher than that of the existing model. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radiation hardened successive-approximation ADC with error detection circuits - 238

For several decades, radiation-hardened-by-design (RHBD) techniques have been developed to meet the design requirements of irradiating environment in nuclear power plants. Improvements on the circuit side for radiation sensors in performance, chip size, and radiation hardening ability have been adopted in current plant systems; however, next generation reactors and/or preparation for severe events in existing reactors require advanced circuit structures that can provide relatively long viability in harsh conditions. In order to maintain performances of electronics in high radiating environments, we propose to develop a small-area, low resource-overhead data-converter architecture that is immune to radiation impact events, an architecture that includes three kinds of novel radiation-hardened (rad-hard) designs for each analog and digital circuit in an ADC structure: a) error detectable tri-state buffer for flip flop against DSET, b) error detection storage in flip flop against SEU, and c) analog algorithm for the analog parts of an SAR ADC. The novel ADC architecture including the three RHBD techniques was implemented in a standard 180 nm CMOS technology with a 1.8 V supply voltage. Simulation results show that the techniques can successfully recognize errors induced by radiation impact events. The static power consumption was 123 {mu}W with the sampling rate 36 MS/s and resolution of 8 bits. The performances could be highly advanced under fine-tune designs. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Identification of the accident-related critical digital assets based on probabilistic safety analysis results - 225

Digital I and C systems have been developed and installed in nuclear power plants, and due to installation of the digital I and C systems, cyber security concerns are increasing in nuclear industry. However, there are too many critical digital assets (CDAs) to be inspected in digitalized NPPs. In order to reduce the inefficiency of regulation in nuclear facilities, the critical digital assets that are directly related to an accident are elicited by using the probabilistic safety assessment results. Target initial events are selected, and their heading are analyzed through event tree analysis. Among the headings, the headings that can be proceeded directly to the core damage by the cyber-attack are finally selected as the target of deriving the minimum cut-sets. Based on success criteria of each heading, we analyze the fault trees and derive the minimum set-cuts. In terms of original PSA, the value of probability for the cut-sets is important but the probability is not important in terms of cyber security of NPPs. The important factors is the number of basic events consisting of the minimal cut-sets that is proportional to vulnerability. Finally, the process for identifying accident-related CDAs is suggested based on PSA results. The results of this study are expected to be used to derive the linkage between cyber-attack and accident, and to develop the final core digital asset identification methodology and effective regulatory method. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗