Selecting a radiation tolerant piezoelectric material for nuclear reactor applications

Bringing systems for online monitoring of nuclear reactors to fruition has been delayed by the lack of suitable ultrasonic sensors. Recent work has demonstrated the capability of an AlN sensor to perform ultrasonic evaluation in an actual nuclear reactor. Although the AlN demonstrated sustainability, no loss in signal amplitude and d{sub 33} up to a fast and thermal neutron fluence of 1.85 Multiplication-Sign 1018 n/cm{sup 2} and 5.8 Multiplication-Sign 1018 n/cm{sup 2} respectively, no formal process to selecting a suitable sensor material was made. It would be ideal to use first principles approaches to somehow reduce each candidate piezoelectric material to a simple ranking showing directly which materials one should expect to be most radiation tolerant. However, the complexity of the problem makes such a ranking impractical and one must appeal to experimental observations. This should not be of any surprise to one whom is familiar with material science as most material properties are obtained in this manner. Therefore, this work adopts a similar approach, the mechanisms affecting radiation tolerance are discussed and a good engineering sense is used for material qualification of the candidate piezoelectric materials.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis and improvement of input channel selection algorithm for reliability of control systems in nuclear power plants - 138

In most of non-safety NSSS (Nuclear Steam Supply System) control systems, a process input is composed of two channels for redundancy. In a normal situation, the average of both input channels is used in the control algorithm. If a failed channel is detected, the 'channel selection algorithm' chooses the remaining normal input channel. For a bumpless transition, many implemented control systems include the 'ramping rate' function, which makes it possible for the selected input to slowly approach the new input channel. However, it recently turned out that this function adopted for positive effects may result in unintended consequences for the related control system and the plant in certain cases. Due to a process transient in the plant according to a significant event, any related sensor input signal can rapidly change and finally exceed the pre-defined range for detecting an out-of-range event in a short time. During the process of channel conversion due to a rapid transient in the plant, the processed input from the redundant channels can be distorted if the ramping rate function is not properly implemented. As a result, it can result in a plant shutdown because the control system fails to perform the critical function to mitigate a plant transient. To solve these potential problems, we analyzed the overall causes and derived a proposed algorithm for improving reliability and performance of the control systems. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Magnetic and Mechanical Analysis of a Large Aperture 15 T Cable Test Facility Dipole Magnet

The US Department of Energy (DOE) Office of Science (SC), is funding a large bore “Cable Test Facility Magnet” for testing advanced cables and inserts in high transverse field. This is a joint effort between the Office of High Energy Physics (HEP) and the Office of Fusion Energy Sciences (FES). The background field magnet for this facility is being developed at Lawrence Berkeley National Laboratory (LBNL) while the cryostat and test facility will be located and operated by Fermi National Accelerator Laboratory (FNAL). The Nb 3 Sn dipole magnet, which will provide the transverse background field, is designed to generate a field of 15 T in a 100 × 150 mm bore at 1.9 K. The conceptual design of a block-type dipole with flared ends and a structure based on key-and-bladder technology will be introduced. The results of the magnetic and mechanical analysis will be presented.

43 PARTICLE ACCELERATORS↗

A next generation ultra short pulse reflectometry (USPR) diagnostic

Ultrashort Pulse Reflectometry (USPR) is a plasma diagnostic technique involving the propagation and reflection of ultrashort duration (~few ns) chirps. The reflected packets pass through a multichannel filter with time-of-flight measurements performed on each of the filtered packets. A next generation USPR system is under development, spanning 28–75 GHz, for use on compact, short duration, magnetically confined fusion devices. This system presents a dramatic increase in performance compared with an earlier USPR system employed on the LLNL Sustained Spheromak Physics Experiment device more than a decade ago. The new system replaces upconverting mixers with higher power active multiplier chains to generate mm-wave transmitter chirps, with custom time-of-flight electronics reducing the time per measurement by a factor of 3X. Finally, the system is equipped with a field programmable gate array for data acquisition and analysis.

47 OTHER INSTRUMENTATION↗

Efficient loading of reduced data ensembles produced at ORNL SNS/HFIR neutron time-of-flight facilities

We present algorithmic improvements to the loading operations of certain reduced data ensembles produced from neutron scattering experiments at Oak Ridge National Laboratory (ORNL) facilities. Ensembles from multiple measurements are required to cover a wide range of the phase space of a sample material of interest. They are stored using the standard NeXus schema on individual HDF5 files. This makes it a scalability challenge, as the number of experiments stored increases in a single ensemble file. The present work follows up on our previous efforts on data management algorithms, to address identified input output (I/O) bottlenecks in Mantid, an open-source data analysis framework used across several neutron science facilities around the world. We reuse an in-memory binary-tree metadata index that resembles data access patterns, to provide a scalable search and extraction mechanism. In addition, several memory operations are refactored and optimized for the current common use cases, ranging most frequently from 10 to 180, and up to 360 separate measurement configurations. Results from this work show consistent speed ups in wall-clock time on the Mantid LoadMD routine, ranging from 19% to 23% on average, on ORNL production computing systems. The latter depends on the complexity of the targeted instrument-specific data and the system I/O and compute variability for the shared computational resources available to users of ORNL’s Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR) instruments. Nevertheless, we continue to highlight the need for more research to address reduction challenges as experimental data volumes, user time and processing costs increase.

Godoy, William↗

Modelling I and C systems with relays for simulation, adapting CIM standards - 243

As the nuclear power plants are in operation for many years, a main issue is to integrate simulation activities in parallel to the present I and C design process in order to limit impacts on current operating I and C engineering process and commissioning activities. The objective is to keep the existing I and C data and diagrams format. EDF chose to build an intermediate file independent of the tool used for simulation to exchange and store data. This file has been created adapting CIM standards (IEC 61968-13 and IEC 61970-301). It is an XML file built according to an RDF schema. CIM standards are intended to model transport or distribution electrical networks and used to facilitate system integration and information exchanges. We chose to adapt CIM to model EDF electromechanical relay circuitries in order to re-use all methods and tools developed around CIM standards such as RDF schema and RiseClipse, an open source tool developed by EDF and SUPELEC engineering school that will be used to verify exported I and C data according to a data model and to EDF engineering rules. This paper will describe the ongoing project on simulation in parallel to current I and C design process, focusing on how I and C electromechanical relays data are modelled based on CIM standards, and what benefits that model provides to I and C Verification and Validation activities. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Common Cause Failure Mitigation Experience on Digital I and C System in NPP

CCF is failures of redundant or separate structures, systems, or components due to a shared root cause. The CCF includes those are resulted from severe environments, design errors, calibration and maintenance errors, and consequential failures. In addition, digital I and C systems can be vulnerable to CCF caused by software errors or software developed logic, which could defeat the redundancy achieved by the hardware architecture. Therefore, diversity and defense in-depth (D3) has become an important issue to overcome the CCF of the safety I and C system. The U.S. NRC has established regulatory guidance addressing a method for assessing D3 provided by the safety I and C system architecture at a NPP. This method enables determination of whether vulnerabilities to CCF have been adequately addressed. The guidance is included in BTP 7-19 and Chapter 7 of NUREG-0800. The regulatory guidance provides a methodology for designing diversity. APR1400 establishes the mitigating strategies that consider the characteristics of digital I and C system that contribute to the potential for CCF. The diversity strategies consist of a combination of diversity attributes and associated criteria to address potential CCF vulnerabilities in digital safety I and C system. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Suggestion of a Framework to Evaluate the Extent of Cyber Security Enhancements in NPP

Digital I and C systems have been developed and installed in nuclear power plants (NPPs). However, due to installation of digital I and C systems, cyber security concerns have been emerged. One of the major problems is that nuclear industry is in very early stage in dealing with cyber security issues. It is because that cyber security has received less attention compared to other safety problems. In addition, late adoption of digital I and C systems has resulted in lower level of cyber security advancements in nuclear industry than ones in other industries. With this regards, recently, international standard organizations, regulatory institutes, and research institutes have performed a number of studies addressing these cyber security issues in nuclear industries. In order to provide useful information about cyber security issues including cyber security enhancements, this paper suggests a framework to evaluate how much cyber security is improved when a specific cyber security enhancement is applied in NPPs. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Graded approach for assessing digital system failure susceptibilities - 305

Owner/operators of nuclear plants must be able to identify and assess susceptibilities to digital system failures and unintended behaviors that could lead to plant system malfunctions, including common-cause failures (CCFs) of multiple controlled components that may impact overall plant safety. Nuclear plant designers and regulators often assess and manage potential failure modes by assuming the failure occurs and showing by analysis that the results are acceptable. In 2016 EPRI published a guideline on Methods for Assuring Safety and Dependability when Applying Digital Instrumentation and Control Systems (EPRI 3002005326), which takes a more holistic approach that considers digital system failure modes from the perspective of their impact on plant risk and includes a graded approach based on safety significance. This paper describes that graded approach. The methodology in EPRI 3002005326 systematically identifies potential I and C vulnerabilities that could lead to significant malfunctions of controlled components and systems, including common-cause failures (CCF), and discusses in detail methods to protect against them. It considers both preventive measures that reduce the likelihood of failures, and plant systems and features that mitigate the effects of component failures and misbehaviors. Coping analysis is then performed as appropriate to provide additional assurance of protection. The safety significance based graded approach is an important feature in that it can help users focus attention on overall plant safety, including potentially risk-significant scenarios that might not be considered in traditional safety analyses. The purpose is to help the user ensure that modifications to the I and C that could potentially be safety significant are treated appropriately and at the same time not waste valuable resources on excessive protection against changes that have little or no impact on safety. The graded approach allows the design engineer to tailor the rigor of the preventive, limiting, and mitigative measures commensurately with the effects the I and C modification has on overall plant safety. The graded approach focuses on safety significance impact, which is effectively a qualitative measure of the potential change in safety (or risk) caused by a proposed I and C modification, as compared to the I and C that is being replaced. Safety significance impact should not be confused with importance to safety or risk significance. It is possible that an upgrade to safety-related and/or risk-significant I and C systems may have little or no safety significant impact and vice versa. The approach considers three factors that influence the impact on safety significance of a proposed I and C modification: context, likelihood of failure, and consequences of failure. The most significant of the three factors is context - what the I and C is connected to, both directly and indirectly, including its potential effects on plant systems that respond to transients or accidents. The graded approach is particularly helpful in assessing potential CCFs resulting from digital I and C failures, and shows why the most problematic CCFs will be those that can affect multiple plant systems. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Differential Die Away Instrument Simulated Performance Using Boiling Water Reactor Spent Fuel Assemblies

As part of evaluating the performance of various Non-Destructive Assay (NDA) instruments measuring the plutonium content and other information about spent nuclear fuel, the Next Generation of Safeguards Initiative (NGSI) Spent Fuel (SF) Project generated spent fuel libraries containing the composition of spent fuel assemblies originating from various reactors, initial enrichments (IE), burnups (BU), and cooling times (CT). Spent Fuel Library (SFL) number 5 (SFL5), representing Boiling Water Reactor (BWR) assemblies, was created as part of a “Gentleman’s Agreement” with Sweden to examine if the Differential Die Away (DDA) instrument performs similarly for BWR assemblies as for the Pressurized Water Reactor (PWR) ones. The difference between PWRs and BWRs is that BWRs have a large axial variation in moderator density because it is in the form of water at the bottom of the reactor but turns into steam as it gets warmer at the top of the reactor; thus, more plutonium builds up at the bottom of each assembly than at the top. In a PWR, the moderator density varies slightly from the bottom to the top, but since it is pressurized, the changes are not as significant with respect to the burnup and plutonium distributions. BWR assemblies are also typically smaller than PWR ones, which could affect detector performance. Since Sweden has both PWR and BWR assemblies, it is anticipated that we will be deploying the DDA instrument to measure both spent fuel assembly (SFA) types.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Procedure design of F and B operation and its impact on the risk of a nuclear power plant - 168

A feed and bleed (F and B) operation is an operator's emergency task to remove core heat from a reactor coolant system by bleeding coolant from the pressurizer, and feeding makeup water through safety injection systems under the loss of all feedwater condition. Even though the F and B operation is an important task having a significant impact on the risk of a nuclear power plant, there is a high uncertainty regarding its modeling and analysis in a PSA. This paper introduces a study on the design of an operational strategy for an F and B operation and its impact on the risk of a nuclear power plant in Korea. An intensive support analysis was conducted to understand the plant behavior and revise the success criteria for the HRA of the F and B operation. A human performance analysis on the emergency tasks was also conducted using a training simulator to generate the operator's performance time for the F and B operation. We revised the PSA model and updated the risk of the reference plant, which shows that the risk of the revised model is much higher than that of the existing model. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

On-Line Monitoring to Detect Sensor and Process Degradation under Normal Operational Transients - 327

Calibration assessment of nuclear plant sensors and transmitters is currently performed through periodic maintenance actions during plant refueling outages. On-line monitoring (OLM) can be used to reduce the time and cost of this maintenance process by using empirical models to evaluate sensor calibration. The implementation of OLM can also mitigate human error associated with unnecessary maintenance on sensors operating within calibration tolerances. OLM has been studied and validated for plants under steady-state baseload operation, but the extension to load-following operation is not well-documented in the literature. Auto-associative kernel regression (AAKR) provides an error-corrected prediction of process sensor measurements for OLM through a weighted average of historic data. The current study evaluates the performance of AAKR for prediction under normal operational transients (such as expected under load-following operation). Performance of the AAKR model with two anomaly detection routines, error uncertainty limit monitoring (EULM) and sequential probability ratio test (SPRT), was evaluated for normal operation, sensor faults, and process degradation. The data used to develop and evaluate the OLM system were collected from a forced flow loop with temperature and flow sensors. Three models of well-correlated groups of sensors are trained to predict normal system behavior under planned transients. The anomaly detection routines are tested for sensor faults and process faults. The results of this experimental study suggest AAKR and an appropriate anomaly detection routine can be applied for sensor calibration and process fault detection under transient operation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Method to calibrate fission chambers in Campbelling mode

Fission chambers are neutron detectors which are widely used to instrument experimental reactors such as material testing reactors or zero power reactors. In the presence of a high level mixed gamma and neutron flux, fission chambers can be operated in Campbelling mode (also known as 'fluctuation mode' or 'mean square voltage mode') to provide reliable and precise neutron related measurements. Fission chamber calibration in Campbelling mode (in terms of neutron flux) is usually done empirically using a calibrated reference detector. A major drawback of this method is that calibration measurements have to be performed in a neutron environment very similar to the one in which the calibrated detector will be used afterwards. What we propose here is a different approach based on characterizing the fission chamber response in terms of fission rate. This way, the detector calibration coefficient is independent from the neutron spectrum and can be determined prior to the experiment. The fissile deposit response to the neutron spectrum can then be assessed independently by other means (experimental or numerical). In this paper, the response of CEA made miniature fission chambers in Campbelling mode is studied. We use a theoretical model of the signal to calculate the calibration coefficient. Input parameters of the model come from statistical distribution of individual pulses. Supporting measurements have been made in the CEA Cadarache zero power reactor MINERVE. Results are compared to an empirical Campbelling mode calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Human Factors Considerations in New Nuclear Power Plants: Detailed Analysis.

This Nuclear Regulatory Commission (NRC) sponsored study has identified human-performance issues in new and advanced nuclear power plants. To identify the issues, current industry developments and trends were evaluated in the areas of reactor technology, instrumentation and control technology, human-system integration technology, and human factors engineering (HFE) methods and tools. The issues were organized into seven high-level HFE topic areas: Role of Personnel and Automation, Staffing and Training, Normal Operations Management, Disturbance and Emergency Management, Maintenance and Change Management, Plant Design and Construction, and HFE Methods and Tools. The issues where then prioritized into four categories using a 'Phenomena Identification and Ranking Table' methodology based on evaluations provided by 14 independent subject matter experts. The subject matter experts were knowledgeable in a variety of disciplines. Vendors, utilities, research organizations and regulators all participated. Twenty issues were categorized into the top priority category. This Brookhaven National Laboratory (BNL) technical report provides the detailed methodology, issue analysis, and results. A summary of the results of this study can be found in NUREG/CR-6947. The research performed for this project has identified a large number of human-performance issues for new control stations and new nuclear power plant designs. The information gathered in this project can serve as input to the development of a long-term strategy and plan for addressing human performance in these areas through regulatory research. Addressing human-performance issues will provide the technical basis from which regulatory review guidance can be developed to meet these challenges. The availability of this review guidance will help set clear expectations for how the NRC staff will evaluate new designs, reduce regulatory uncertainty, and provide a well-defined path to new nuclear power plant licensing.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Taxonomy for Common-Cause Failure Vulnerability and Mitigation

Applying current guidance and practices for common-cause failure (CCF) mitigation to digital instrumentation and control (I&C) systems has proven problematic, and the regulatory environment has been unpredictable. The potential for CCF vulnerability inhibits I&C modernization, thereby challenging the long-term sustainability of existing plants. For new plants and advanced reactor concepts, concern about CCF vulnerability in highly integrated digital I&C systems imposes a design burden that results in higher costs and increased complexity. The regulatory uncertainty in determining which mitigation strategies will be acceptable (e.g., what diversity is needed and how much is sufficient) drives designers to adopt complicated, costly solutions devised for existing plants. To address the conditions that constrain the transition to digital I&C technology by the US nuclear industry, crosscutting research is needed to resolve uncertainty, demonstrate necessary characteristics, and establish an objective basis for qualification of digital technology for nuclear power plant (NPP) I&C applications. To fulfill this research need, Oak Ridge National Laboratory is investigating mitigation of CCF vulnerability for nuclear-qualified applications. The outcome of this research is expected to contribute to a fundamentally sound, comprehensive basis to qualify digital technology for nuclear power applications. This report documents the development of a CCF taxonomy. The basis for the CCF taxonomy was generated by determining consistent terminology and establishing a classification approach. The terminology is based on definitions from standards, guides, and relevant nuclear power industry technical reports. The classification approach is derived from identified classification schemes focused on I&C systems and key characteristics, including failure modes. The CCF taxonomy provides the basis for a systematic organization of key systems aspects relevant to analyzing the potential for CCF vulnerability and the suitability of mitigation techniques. Development of an effective CCF taxonomy will help to provide a framework for establishing the objective analysis and assessment capabilities desired to facilitate rigorous identification of fault types and triggers that are the fundamental elements of CCF.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Methodological approach to the sensitivity analysis of failure effects in modern digital I and C systems - 136

Modern I and C systems of nuclear power plants increasingly use digital equipment, software-based applications for I and C functions and different types and topologies of communication networks as well. The structure, operation and communication of digital safety-related I and C systems are strongly influenced by the implemented automatic fault detection and fault treatment procedures as barriers against failure propagation. Thus, these I and C systems can change their operating states automatically during the operation time, e.g. due to the detection and correction of certain failure types. Reasonably because of these dynamic properties of digital I and C systems the use of classical fault tree and event tree methods solely for the reliability analysis of modern I and C systems is less suitable. These methods basically apply static models and do not consider the temporal changes of the operating state of the I and C system or equipment appropriately. In this paper, a recently developed approach for the sensitivity analysis of digital I and C systems will be introduced that allows to investigate the dynamic behavior of such systems in cases of internal faults and to quantify the effects on the system reliability. The development and testing of the analysis methodology is carried out using models of generic I and C systems with different typical architectures of stepwise increased complexity. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Knowledge Preservation at the Fast Flux Test Facility

One of the goals of the Department of Energy's Office of Nuclear Energy Fuel Cycle Research and Development Program (FCRD) is to preserve the knowledge that has been gained in the United States on Liquid Metal Reactors (LMRs) that could support the development of an environmentally and economically sound nuclear fuel cycle. The Fast Flux Test Facility (FFTF) is the most recent LMR to operate in the United States, from 1982 to 1992, and was designed as a fully instrumented test reactor with on-line, real time test control and performance monitoring of components and tests installed in the reactor. Knowledge preservation at the FFTF is focused on the areas of design, construction, and startup of the reactor, as well as on preserving information obtained from 10 years of successful operating history and extensive irradiation testing of fuels and materials. In order to ensure protection of information at risk, the program to date has sequestered reports, files, tapes, and drawings to allow for secure retrieval. A disciplined and orderly approach has been developed to respond to client's requests for documents and data in order to minimize the search effort and ensure that future requests for this information can be readily accommodated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preserving Physics Knowledge at the Fast Flux Test Facility

One of the goals of the Department of Energy’s Office of Nuclear Energy, initiated under the Fuel Cycle Research and Development Program (FCRD) and continued under the Advanced Reactor Concepts Program (ARC) is to preserve the knowledge that has been gained in the United States on Liquid Metal Reactors (LMRs) that could support the development of an environmentally and economically sound nuclear fuel cycle. The Fast Flux Test Facility (FFTF) is the most recent LMR to operate in the United States, from 1982 to 1992, and was designed as a fully instrumented test reactor with on-line, real time test control and performance monitoring of components and tests installed in the reactor. The 10 years of operation of the FFTF provided a very useful framework for testing the advances in LMR safety technology based on passive safety features that may be of increased importance to new designs after the events at Fukushima. Knowledge preservation at the FFTF is focused on the areas of design, construction, and startup of the reactor, as well as on preserving information obtained from 10 years of successful operating history and extensive irradiation testing of fuels and materials. In order to ensure protection of information at risk, the program to date has sequestered reports, files, tapes, and drawings to allow for secure retrieval. A disciplined and orderly approach has been developed to respond to client’s requests for documents and data in order to minimize the search effort and ensure that future requests for this information can be readily accommodated.