Search NASA⌕ Search

SEARCH · Search NASA

Results for “REFRIGERATING EQUIPMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Numerical Simulation Studies of Ultrasonic De-Icing for Heating, Ventilation, Air Conditioning, and Refrigeration Structures

Ice accumulation on heating, ventilation, air conditioning, and refrigeration (HVACR) structures presents significant operational challenges. These challenges include reduced efficiency, increased energy consumption, and potential damage to equipment. Traditional de-icing methods, such as chemical treatments, mechanical scraping, or heating-based techniques, are often labor-intensive, costly, and environmentally harmful. Here, this study uniquely investigates ultrasonic de-icing as an energy-efficient alternative for HVACR applications, focusing on the specific structural geometries found in these systems. A comprehensive numerical simulation framework was developed using finite element analysis to explore ultrasonic wave propagation across four distinct HVACR structures. Key parameters such as ultrasonic frequency, power levels, and the number and placement of actuators were examined for their impact on ice detachment efficiency. Results from simulations on a plate structure reveal that ultrasonic excitation can propagate effectively across large areas (at least 150 × 150 mm), enhancing the de-icing coverage. Lower frequency (e.g., 30 to 45 kHz) excitation results in greater displacement, improving de-icing performance, while increased actuator numbers with the same total power input also enhance effectiveness. Two actuators seem sufficient for the de-icing of a 300 × 300 mm plate. For tube-and-fin structures, specific high-power ultrasonic frequencies selectively excite the fin plates, demonstrating efficient ice removal when actuated on the tube. However, optimal performance requires careful design of actuator placement and vibration modes to accommodate the irregular shapes of these structures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Testing of the 2.6 GHz SRF Cavity Tuner for the Dark Photon Experiment at 2 K

At FNAL two single cell 2.6 GHz SRF cavities are being used to search for dark photons, the experiment can be conducted at 2 K or in a dilution refrigerator. Precise frequency tuning is required for these two cavities so they can be matched in frequency. A cooling capacity constraint on the dilution refrigerator only allows piezo actuators to be part of the design of the 2.6 GHz cavity tuner. The tuner is equipped with three encapsulated piezos that deliver long and short-range frequency tuning. Modifications were implemented on the first tuner design due to the low forces on the piezos caused by the cavity. Three brass rods with Belleville washers were added to the design to increase the overall force on the piezos. The testing results at 2 K are presented with the original design tuner and with the modification.

43 PARTICLE ACCELERATORS↗

2 Kelvin helium distribution system for the Electron Ion Collider’s 10 o’clock satellite refrigerator

The Electron-Ion Collider (EIC) at Brookhaven National Laboratory (BNL) will involve superfluid helium cooling of superconducting magnets and Superconducting Radio Frequency (SRF) cavities at several sites around the existing Relativistic Heavy Ion Collider (RHIC) accelerator tunnel. While the majority of the cooling power for these loads is provided by BNL’s central cryogenic plant, Jefferson Lab is designing satellite equipment which augments the central plant and enables 2 Kelvin operation. The 2 K cryogenic distribution system for the collider’s 10 o’clock location (Interaction Region 10 or IR10) includes all necessary interfaces to the IR10 Satellite Refrigerator, to the overall EIC cryogenic distribution system, and to 12 SRF cryomodules for the electron and hadron storage rings. In addition to providing the required cooling capacities in all operating modes, the IR10 2 K cryogenic distribution system also stabilizes the supply temperature and enables safe connection and disconnection of individual IR10 cryomodules. Moreover, the layout of the IR10 2 K cryogenic distribution system copes with challenging spatial constraints and adapts to the process configuration and routing of existing RHIC cryogenic distribution components which will be re-used for EIC. This paper gives a full overview of the IR10 satellite cryogenic distribution system design, and highlights some of the challenges encountered.

Laverdure, Nathaniel [Thomas Jefferson National Ac↗

Low global warming potential (GWP) refrigerant supermarket refrigeration system modeling and its application

As an environmentally friendly low global warming potential (GWP) refrigerant, Carbon dioxide (CO 2 ) has continuously gained popularity and research attention as alternative refrigerant for supermarket refrigeration system. In this paper, to fulfill the increasing need of accurate Low-GWP supermarket refrigeration models for development of supervisory level control and optimization strategies, a high fidelity model is developed for CO 2 transcritical supermarket refrigeration system which includes compressor rack of low temperature (LT) compressors and medium temperature (MT) compressors, air-cooled gas cooler, evaporator, expansion valves and other auxiliary equipment. A resistance-capacity model structure is proposed to simulate the display cases. Semi-thermodynamic models are proposed to estimate reciprocating compressors volumetric efficiency and power consumption. Furthermore the zone modeling approach is used for evaporator simulation, and air-cooled gas cooler is modeled with distributed modeling method. The expansion valve simulation is based on orifice flow model. To calibrate these models, both manufacture performance data and experimental data are used. The experiments are conducted with a full instrumental CO 2 supermarket refrigeration system installed in Oak Ridge National Lab Flexible Research Platform (FRP). The simulation model can predict the system performance, including power consumption, cooling capacity, mass flow rate, temperature, and pressure, with high accuracy (within ±4%) compared to experimental data. In addition, this developed model has been used to create the system optimum high side pressure for high side expansion valve control, and to generate wide operating range simulation data for developing the batter-equivalent commercial refrigeration system model which can be used in grid interactive control development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2.6GHz SRF Cavity Tuner for DarkPhoton Experiment [Poster]

There are several experiments ongoing at FNAL that require frequency tuning of bare (undressed) SRF cavities when they are cooled down and operated inside dilution refrigerator. One of these experiments is for the search of dark photons using a 2.6 GHz SRF cavity. The limited heat capacity of a dilution refrigerator prevents using a stepper motor for an SRF cavity tuner. The tuner for the 2.6 GHz SRF cavity will be equipped with encapsulated piezo actuators that will deliver long and short-range frequency tuning. Design of the tuner and results of the testing cavity/tuner system at ambient environment and at T = 77 K will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Life Sciences Research in the Centrifuge Accommodation Module of the International Space Station

The Centrifuge Accommodation Module (CAM) will be the home of the fundamental biology research facilities on the International Space Station (ISS). These facilities are being built by the Biological Research Project (BRP), whose goal is to oversee development of a wide variety of habitats and host systems to support life sciences research on the ISS. The habitats and host systems are designed to provide life support for a variety of specimens including cells, bacteria, yeast, plants, fish, rodents, eggs (e.g., quail), and insects. Each habitat contains specimen chambers that allow for easy manipulation of specimens and alteration of sample numbers. All habitats are capable of sustaining life support for 90 days and have automated as well as full telescience capabilities for sending habitat parameters data to investigator homesite laboratories. The habitats provide all basic life support capabilities including temperature control, humidity monitoring and control, waste management, food, media and water delivery as well as adjustable lighting. All habitats will have either an internal centrifuge or are fitted to the 2.5-meter diameter centrifuge allowing for variable centrifugation up to 2 g. Specimen chambers are removable so that the specimens can be handled in the life sciences glovebox. Laboratory support equipment is provided for handling the specimens. This includes a compound and dissecting microscope with advanced video imaging, mass measuring devices, refrigerated centrifuge for processing biological samples, pH meter, fixation and complete cryogenic storage capabilities. The research capabilities provided by the fundamental biology facilities will allow for flexibility and efficiency for long term research on the International Space Station.

Dalton, Bonnie P.↗

Overview and status of the Long-Baseline Neutrino Facility Far Site cryogenics system

The Sanford Underground Research Facility (SURF) will host the Far Detector of the Deep Underground Neutrino Experiment (DUNE), an international multi-kiloton Long-Baseline neutrino experiment that will be installed about one and a half kilometers underground in Lead, SD. Detectors will be located inside four cryostats filled with almost 70,000 metric tons of ultrapure liquid argon, with a level of impurities lower than 100 parts per trillion of oxygen equivalent contamination. The cryogenics infrastructure supporting this experiment is provided by the Long-Baseline Neutrino Facility (LBNF). This contribution presents modes of operation, layout, and main features of the LBNF Far Site cryogenic system, which is composed of three subsystems: Infrastructure, Proximity, and Internal cryogenics. The Infrastructure cryogenics supports the needs of the cryostat and Proximity cryogenics. It includes the equipment to receive the argon in liquid phase, vaporize it and transfer it underground as a gas, the nitrogen system (composed of the refrigeration system, liquid nitrogen buffer tanks and liquid and gaseous nitrogen distribution), liquid and gaseous argon distribution and process controls. The Proximity cryogenics receives fluids from the Infrastructure cryogenics and delivers them to the Internal cryogenics at the required temperature, pressure, purity and mass flow rate. It includes the argon condensers, liquid and gaseous argon purification and regeneration systems, nitrogen and argon phase separators, piping, valves, and instrumentation. The Internal cryogenics comprises the liquid and gaseous argon distribution inside the cryostats for the commissioning, cool down, fill, and steady state operations of the cryostats and detectors. An international engineering team is designing these systems and will manufacture, install, commission, and qualify them. This contribution describes the main features, performance, functional requirements, and modes of operation of the LBNF Far Site cryogenics system. It also presents the status of the design, along with present and future needs to support the DUNE experiment.

43 PARTICLE ACCELERATORS↗

Critical Material Supply Chain Analysis: Magnetocalorics

Understanding manufacturing cost and supply chain implications of technologies is critical to aid adoption of next-generation energy solutions, such as advanced heating ventilation and air conditioning (HVAC) equipment for building energy efficiency. This report provides insights into the market, regulatory, technology, and cost drivers most impacting the adoption of magnetocaloric refrigeration (MCR) systems in the U.S., with a focus on the rare earth materials requirements, manufacturing costs of key components, and detail on the supply chain of critical materials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In-flight medical support system

The In-flight Medical Support System for Skylab was designed to provide the onboard Crew Physician or Scientist Pilot (or other crewmember if the Scientist Pilot was unable to act) with information adequate to make diagnostic assessment of those injuries or illnesses most likely to occur in the Skylab environment. The necessary diagnostic, therapeutic, and laboratory equipment needed to diagnose and to render first aid, resuscitative or supportive measures was stored in the Skylab Orbital Workshop. The resupply kit containing refrigerated laboratory and drug resupply items was stored in the Command Module.

Chassay, C.↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Thermal deflection in neutron scattering sample environments at Oak Ridge National Laboratory

The neutron sources at Oak Ridge National Laboratory use a wide suite of sample environment equipment to deliver extreme conditions for a number of experiments. Much of this instrumentation focuses on extremes of temperature, such as cryostats, closed-cycle refrigerators in both low and high temperature configurations, and radiant heating furnaces. When the temperature is controlled across a large range, thermal deflection effects can notably move the sample and affect its alignment in the beam. Here, we combine these sample environments with neutron imaging and machine vision to determine the motion of a representative sample with respect to the neutron beam. We find vertical sample displacement on the order of 1–2 mm and horizontal displacement that varies from near-negligible to 1.2 mm. While these deflections are not relevant for some of the beamlines at the first target station at the spallation neutron source and the high flux isotope reactor, they will become critical for upcoming instrumentation at the second target station, as well as any instruments targeting sub-mm samples, as neutron sources and optics evolve to smaller and more focused beams. We discuss mitigation protocols and potential modifications to the environment to minimize the effect of misalignment due to thermal deflection.

47 OTHER INSTRUMENTATION↗

Experiments with phase transitions at very high pressure

Diamond cells were constructed for use to 1 Mbar. A refrigerator for cooling diamond cells was adapted for studies between 15 and 300 K. A cryostat for superconductivity studies between 1.5 to 300 K was constructed. Optical equipment was constructed for fluorescence, transmission, and reflectance studies. X-ray equipment was adapted for use with diamond cells. Experimental techniques were developed for X-ray diffraction studies using synchrotron radiation. AC susceptibility techniques were developed for detecting superconducting transitions. The following materials were studied: compressed solidified gases (Xe, Ar), semiconductors (Ge, Si, GaAs), superconductors (Nb3Ge, Nb3Si, Nb3As, CuCl), molecular crystals (I).

Spain, I. L.↗

Mechanically Tunable Radiative Cooling for Adaptive Thermal Control

Passive radiative cooling is currently thefrontier technology in renewable-energy research. Interms of extraterrestrial applications, radiative cooling is a critical component to the thermalmanagement system of a spacecraft, where the extreme environment of space can cause largetemperature variations that can break and damage equipment. For terrestrial applications,nocturnal or daytime radiative cooling is expected to lead to cost-effective passive heatmanagement without the need of inefficient and costly artificial refrigeration technologies.However, most currently available radiative cooling systems cannot be changed dynamically andradiate a constant static amount of thermal power. Dynamically tunable adaptive radiativecooling systems will be a critical development to prolong the lifetime of spacecraft or improvethe efficiency of terrestrial cooling systems. Here we propose stretchable radiative coolingdesigns that can be substantially tuned by using the simple physical mechanism of mechanical strain. When their structure is stretched, the radiated power is significantly reduced. We developa modeling method that can simulate mechanical stretching combined with electromagnetic response to compute the tunable thermal emission of these new adaptive radiative coolingsystems. The presented photonically engineered structures can be used as coatings to achieveefficient adaptive thermal control of various objects in a cost-effective and environmentallyfriendly way. The proposed designs are much simpler to be realized than others found in theliterature and the best design achieves a high thermal emission power with a tunable range on theorder of 132 W/m2.

Andrew Butler↗

Investing American Recovery and Reinvestment Act Funds to Advance Capability, Reliability, and Performance in NASA Wind Tunnels

The National Aeronautics and Space Administration's (NASA) Aeronautics Test Program (ATP) is implementing five significant ground-based test facility projects across the nation with funding provided by the American Recovery and Reinvestment Act (ARRA). The projects were selected as the best candidates within the constraints of the ARRA and the strategic plan of ATP. They are a combination of much-needed large scale maintenance, reliability, and system upgrades plus creating new test beds for upcoming research programs. The projects are: 1.) Re-activation of a large compressor to provide a second source for compressed air and vacuum to the Unitary Plan Wind Tunnel at the Ames Research Center (ARC) 2.) Addition of high-altitude ice crystal generation at the Glenn Research Center Propulsion Systems Laboratory Test Cell 3, 3.) New refrigeration system and tunnel heat exchanger for the Icing Research Tunnel at the Glenn Research Center, 4.) Technical viability improvements for the National Transonic Facility at the Langley Research Center, and 5.) Modifications to conduct Environmentally Responsible Aviation and Rotorcraft research at the 14 x 22 Subsonic Tunnel at Langley Research Center. The selection rationale, problem statement, and technical solution summary for each project is given here. The benefits and challenges of the ARRA funded projects are discussed. Indirectly, this opportunity provides the advantages of developing experience in NASA's workforce in large projects and maintaining corporate knowledge in that very unique capability. It is envisioned that improved facilities will attract a larger user base and capabilities that are needed for current and future research efforts will offer revenue growth and future operations stability. Several of the chosen projects will maximize wind tunnel reliability and maintainability by using newer, proven technologies in place of older and obsolete equipment and processes. The projects will meet NASA's goal of integrating more efficient, environmentally safer, and less energy consuming hardware and processes into existing tunnel systems. These include Environmental Protection Agency-approved refrigerants, energy efficient motors, and faster, flexible tunnel data systems.

Sydnor, Goerge H.↗

Space station experiment definition: Long-term cryogenic fluid storage

The conceptual design of a space station Technology Development Mission (TDM) experiment to demonstrate and evaluate cryogenic fluid storage and transfer technologies is presented. The experiment will be deployed on the initial operational capability (IOC) space station for a four-year duration. It is modular in design, consisting of three phases to test the following technologies: passive thermal technologies (phase 1), fluid transfer (phase 2), and active refrigeration (phase 3). Use of existing hardware was a primary consideration throughout the design effort. A conceptual design of the experiment was completed, including configuration sketches, system schematics, equipment specifications, and space station resources and interface requirements. These requirements were entered into the NASA Space Station Mission Data Base. A program plan was developed defining a twelve-year development and flight plan. Program cost estimates are given.

Jetley, R. L.↗

NASA SBIR product catalog, 1991

This catalog is a partial list of products of NASA SBIR (Small Business Innovation Research) projects that have advanced to some degree into Phase 3. While most of the products evolved from work conducted during SBIR Phase 1 and 2, a few advanced to commercial status solely from Phase 1 activities. The catalog presents information provided to NASA by SBIR contractors who wished to have their products exhibited at Technology 2001, a NASA-sponsored technology transfer conference held in San Jose, California, on December 4, 5, and 6, 1991. The catalog presents the product information in the following technology areas: computer and communication systems; information processing and AI; robotics and automation; signal and image processing; microelectronics; electronic devices and equipment; microwave electronic devices; optical devices and lasers; advanced materials; materials processing; materials testing and NDE; materials instrumentation; aerodynamics and aircraft; fluid mechanics and measurement; heat transfer devices; refrigeration and cryogenics; energy conversion devices; oceanographic instruments; atmosphere monitoring devices; water management; life science instruments; and spacecraft electromechanical systems.

Source record↗

Managing Army Plug Load Equipment Energy Use: Vending Machines

Vending machines consume the most energy of individual plug load devices common to Army buildings. As a group, they rank fourth in total electricity consumption, behind only clothes dryers, laptop computers, and telecom loads. Upgrading 80% of the estimated 22,000 refrigerated vending machines on Army installations to the latest ENERGY STAR ® performance and optimizing their efficiency settings could save 31 million kWh and $2 million per year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗