AWAKEN Site A2 Profiling Lidar (Windcube v2.1) / Raw Data

This dataset contains raw data from the profiling lidar (Windcube v2.1) at AWAKEN site A2. Two data types are included here: 1) STA files, which have 10-minute average data, and 2) RTD files, which have real time data, at about 1 Hz resolution.

17 WIND ENERGY↗

WFIP3 - SHIP site - NREL Profiling Lidar (Windcube v2.1) / Reviewed data

This dataset contains reviewed data from the profiling lidar (Windcube v2.1) deployed on WFIP3's SHIP. The reviewed files herein are based on the lidar's RTD files (i.e., the real-time raw data files at near 1 Hz resolution). The data have been corrected for the motion of the ship.

17 WIND ENERGY↗

WFIP3 - BARG site - NREL Profiling Lidar (Windcube v2.1) / Reviewed Data

This dataset contains reviewed data from the profiling lidar (Windcube v2.1) deployed on WFIP3's barge. The reviewed files herein are based on the lidar's RTD files (i.e., the real-time raw data files at near 1 Hz resolution). The data have been corrected for the motion of the ship.

17 WIND ENERGY↗

WFIP3 - BARG site - NREL Profiling Lidar (Windcube v2.1) / Raw Data

This dataset contains raw data from NREL's profiling lidar (Windcube v2.1) at the WFIP3 BARG site. Two data types are included here: 1) STA files, which have 10-minute average data, and 2) RTD files, which have real time data, at about 1 Hz resolution. Note: these data have NOT been corrected for the motion of the barge.

17 WIND ENERGY↗

WFIP3 - BARG site - NREL Profiling Lidar (Windcube v2.1) / Raw Data

This dataset contains raw data from NREL's profiling lidar (Windcube v2.1) at the WFIP3 NOAA SHIP site. Two data types are included here: 1) STA files, which have 10-minute average data, and 2) RTD files, which have real time data, at about 1 Hz resolution.

17 WIND ENERGY↗

FC Site 4.0 - NLR Profiling Lidar (Windcube v2.1) / Raw data

The dataset contains raw data from the ground-based NLR profiling lidar (Windcube v2.1) at FC Site 4.0. Two data types are included here: 1) STA files, which have 10-minute average data, and 2) RTD files, which have real-time data, at about 1 Hz resolution.

17 WIND ENERGY↗

5 mW parallel-connected resonant-tunnelling diode oscillator

A new type of resonant-tunneling diode (RTD) oscillator that generates 5 mW at 1.18 GHz is reported. This result was obtained by connecting in parallel 25 individual diodes designed for such a connection. This experiment demonstrates that RTDs can successfully be used in a chip-level power-combining circuit.

Stephan, K. D.↗

Monolithic millimeter-wave diode grid frequency multiplier arrays

Monolithic diode frequency multiplier arrays, including barrier-N-N(+) (BNN) doubler, multi-quantum-barrier-varactor (MQBV) tripler, Schottky-quantum-barrier-varactor (SQBV) tripler, and resonant-tunneling-diode (RTD) tripler arrays, have been successfully fabricated with yields between 85 and 99 percent. Frequency doubling and/or tripling have been observed for all the arrays. Output powers of 2.4-2.6 W (eta = 10-18 percent) at 66 GHz with the BNN doubler and 3.8-10 W (eta = 1.7-4 percent) at 99 GHz with the SQBV tripler have been achieved.

Liu, Hong-Xia L.↗

Fundamental and subharmonic excitation for an oscillator with several tunneling diodes in series

Connecting several tunneling diodes in series shows promise as a method for increasing the output power of these devices as millimeter-wave oscillators. However, due to the negative differential resistance (NDR) region in the dc I-V curve of a single tunneling diode, a circuit using several devices connected in series, and biased simultaneously in the NDR region, is dc unstable. Because of this instability, an oscillator with several tunneling diodes in series has a demanding excitation condition. Excitation using an externally applied RF signal is one approach to solving this problem. This is experimentally demonstrated using an RF source, both with frequency close to as well as with frequency considerably lower than the oscillation frequency. Excitation by an RF (radio frequency) source with a frequency as low as one sixth of the oscillation frequency was demonstrated in a proof-of-principle experiment at 2 GHz, for an oscillator with two tunnel diodes connected in series. Strong harmonics of the oscillation signal were generated as a result of the highly nonlinear dc I-V curve of the tunnel diode and a large signal oscillator design. Third harmonic output power comparable to that of the fundamental was observed in one oscillator circuit. If submillimeter wave resonant-tunneling diodes (RTD's) are used instead of tunnel diodes, this harmonic output may be useful for generating signals at frequencies well into the terahertz range.

SUBHARMONIC EXCITATION↗

Properties of Two Carbon Composite Materials Using LTM25 Epoxy Resin

In this report, the properties of two carbon-epoxy prepreg materials are presented. The epoxy resin used in these two materials can yield lower manufacturing costs due to its low initial cure temperature, and the capability of being cured using vacuum pressure only. The two materials selected for this study are MR50/LTM25, and CFS003/LTM25 with Amoco T300 fiber; both prepregs are manufactured by The Advanced Composites Group. MR50/LTM25 is a unidirectional prepreg tape using Mitsubishi MR50 carbon fiber impregnated with LTM25 epoxy resin. CRS003/LTM25 is a 2 by 2 twill fabric using Amoco T300 fiber and impregnated with LTM25 epoxy resin. Among the properties presented in this report are strength, stiffness, bolt bearing, and damage tolerance. Many of these properties were obtained at three environmental conditions: cold temperature/dry (CTD), room temperature/dry (RTD), and elevated temperature/wet (ETW). A few properties were obtained at room temperature/wet (RTW), and elevated temperature/dry (ETD). The cold and elevated temperatures used for testing were -125 F and 180 F, respectively. In addition, several properties related to processing are presented.

Cruz, Juan R.↗

High Accuracy Temperature Measurements Using RTDs with Current Loop Conditioning

To measure temperatures with a greater degree of accuracy than is possible with thermocouples, RTDs (Resistive Temperature Detectors) are typically used. Calibration standards use specialized high precision RTD probes with accuracies approaching 0.001 F. These are extremely delicate devices, and far too costly to be used in test facility instrumentation. Less costly sensors which are designed for aeronautical wind tunnel testing are available and can be readily adapted to probes, rakes, and test rigs. With proper signal conditioning of the sensor, temperature accuracies of 0.1 F is obtainable. For reasons that will be explored in this paper, the Anderson current loop is the preferred method used for signal conditioning. This scheme has been used in NASA Lewis Research Center's 9 x 15 Low Speed Wind Tunnel, and is detailed.

Hill, Gerald M.↗

Validation of NASA Thermal Ice Protection Computer Codes: The Validation of Antice - Part 3

An experimental program was generated by the Icing Technology Branch at NASA Glenn Research Center to validate two ice protection simulation codes: (1) LEWICE/Thermal for transient electrothermal de-icing and anti-icing simulations, and (2) ANTICE for steady state hot gas and electrothermal anti-icing simulations. An electrothermal ice protection system was designed and constructed integral to a 36 inch chord NACA0012 airfoil. The model was fully instrumented with thermo-couples, RTD'S, and heat flux gages. Tests were conducted at several icing environmental conditions during a two week period at the NASA Glenn Icing Research Tunnel. Experimental results of running-wet and evaporative cases were compared to the ANTICE computer code predictions and are presented in this paper.

Al-Khalil, Kamel M.↗

A Measurable Difference: Bridge Versus Loop

Trig-Tek, Inc.'s Model 251A ACL-8 Anderson Current Loop (ACL) Conditioner is an eight channel device designed to condition variable-resistant sensor signals from Strain Gage and RTD's (Resistance Temperature Device)s. It uses NASA's patented ACL technology instead of the classic wheatstone bridge. The electronic measurement circuit delivers accuracy far beyond previous methods and prevents errors caused by variation in the wires that connect sensors to data collection equipment. This is the first license to market a NASA Dryden Flight Research Center patent.

Source record↗

Current Developments in Future Planetary Probe Sensors for TPS

In-situ Thermal Protection System (TPS) sensors are required to provide traceability of TPS performance and sizing tools. Traceability will lead to higher fidelity design tools, which in turn will lead to lower design safety margins, and decreased heatshield mass. Decreasing TPS mass will enable certain missions that are not otherwise feasible, and directly increase science payload. NASA Ames is currently developing two flight measurements as essential to advancing the state of TPS traceability for material modeling and aerothermal simulation: heat flux and surface recession (for ablators). The heat flux gage is applicable to both ablators and non-ablators and is therefore the more generalized sensor concept of the two with wider applicability to mission scenarios. This paper describes the development of a microsensor capable of surface and in-depth temperature and heat flux measurements for TPS materials appropriate to Titan, Neptune, and Mars aerocapture, and direct entry. The thermal sensor will be monolithic solid state devices composed of thick film platinum RTD on an alumina substrate. Choice of materials and critical dimensions are used to tailor gage response, determined during calibration activities, to specific (forebody vs. aftbody) heating environments. Current design has maximum operating temperature of 1500 K, and allowable constant heat flux of q=28.7 watts per square centimeter, and time constants between 0.05 and 0.2 seconds. The catalytic and radiative response of these heat flux gages can also be changed through the use of appropriate coatings. By using several co-located gages with various surface coatings, data can be obtained to isolate surface heat flux components due to radiation, catalycity and convection. Selectivity to radiative heat flux is a useful feature even for an in-depth gage, as radiative transport may be a significant heat transport mechanism for porous TPS materials in Titan aerocapture. This paper also reports on progress to adapt a previously flown surface recession sensor, based on the Jupiter probe Galileo Analog Resistance Ablation Detector (ARAD), to appropriate aerocapture conditions.

Martinez, Ed↗

Development of Solid State Thermal Sensors for Aeroshell TPS Flight Applications

In-situ Thermal Protection System (TPS) sensors are required to provide verification by traceability of TPS performance and sizing tools. Traceability will lead to higher fidelity design tools, which in turn will lead to lower design safety margins, and decreased heatshield mass. Decreasing TPS mass will enable certain missions that are not otherwise feasible, and directly increase science payload. NASA Ames is currently developing two flight measurements as essential to advancing the state of TPS traceability for material modeling and aerothermal simulation: heat flux and surface recession (for ablators). The heat flux gage is applicable to both ablators and non-ablators and is therefore the more generalized sensor concept of the two with wider applicability to mission scenarios. This paper describes the continuing development of a thermal microsensor capable of surface and in-depth temperature and heat flux measurements for TPS materials appropriate to Titan, Neptune, and Mars aerocapture, and direct entry. The thermal sensor is a monolithic solid state device composed of thick film platinum RTD on an alumina substrate. Choice of materials and critical dimensions are used to tailor gage response, determined during calibration activities, to specific (forebody vs. aftbody) heating environments. Current design has maximum operating temperature of 1500K, and allowable constant heat flux of q=28.7 W/cm(sup 2), and time constants between 0.05 and 0.2 seconds. The catalytic and radiative response of these heat flux gages can also be changed through the use of appropriate coatings. By using several co-located gages with various surface coatings, data can be obtained to isolate surface heat flux components due to radiation, catalycity and convection. Selectivity to radiative heat flux is a useful feature even for an in-depth gage, as radiative transport may be a significant heat transport mechanism for porous TPS materials in Titan aerocapture.

Martinez, Ed↗