Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Decomposing Cloud Radiative Feedbacks by Cloud-Top Phase

Changes in cloud scattering properties and emissivity that arise from atmospheric warming cause substantial radiative feedbacks in model projections of anthropogenic climate change, and the relative importance of the underlying mechanisms is poorly understood. One leading hypothesis is that ice-to-liquid conversions cause clouds to optically thicken, producing a major negative feedback. We test this hypothesis by developing a method to decompose cloud radiative feedbacks by cloud-top phase. The method is applied to an ensemble of six state-of-the-art global climate models run with prescribed sea surface temperature. In these simulations, the global mean of the net cloud scattering and emissivity feedback from cloud-phase conversions ranges from −0.17 to −0.01 W m −2 K −1 , while the overall net cloud feedback ranges from 0.02 to 0.91 W m −2 K −1 . The multimodel mean of the cloud scattering and emissivity feedback from cloud-phase conversions is approximately 19% of the magnitude of the multimodel mean of the overall cloud feedback (−0.10 vs 0.52 W m −2 K −1 ). These results indicate that cloud-phase conversions cause a robust negative feedback by changing cloud scattering and emissivity, but this mechanism makes a modest contribution to the overall cloud feedback at the global scale.

Climate change↗

The CMS Phase-2 Fast Beam Condition Monitor prototype test with beam

The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and features a new, radiation-hard, front-end application-specific integrated circuit (ASIC) designed for beam monitoring applications. The achieved timing resolution of a few nanoseconds enables the measurement of both the luminosity and the beam-induced background. The ASIC, called FBCM23, features six channels with adjustable shaping times, enabling in-field fine-tuning. Each ASIC channel outputs a single binary asynchronous signal encoding time-of-arrival and time-over-threshold information. The FBCM is based on silicon-pad sensors, with two sensor designs presently being considered. This paper presents the results of tests of the FBCM detector prototype using both types of silicon sensors with hadron, muon, and electron beams. Irradiated FBCM23 ASICs and silicon-pad sensors were also tested to simulate the expected conditions near the end of the detector's lifetime in the HL-LHC radiation environment. Based on test results, direct bonding between the sensor and ASIC was chosen, and an optimal bias voltage and ASIC threshold for FBCM operation were proposed. The current design of the front-end test board was validated following the beam test and is now being used for the first front-end module, which is expected to be produced in summer 2025. These results represent a major step forward in validating the FBCM concept, first version of the firmware and establishing a reliable design path for the final detector.

Beam-line instrumentation (beam position and profi↗

Application of FISH based G2-PCC assay for the cytogenetic assessment of high radiation dose exposures: Potential implications for rapid triage biodosimetry

The main goal of this study is to test the utility of calyculin A induced G2-PCC assay as a biodosimetry triage tool for assessing a wide range of low and acute high radiation dose exposures of photons. Towards this initiative, chromosome aberrations induced by low and high doses of x-rays were evaluated and characterized in G2-prematurely condensed chromosomes (G2-PCCs) by fluorescence in situ hybridization (FISH) using human centromere and telomere specific PNA (peptide nucleic acid) probes. A dose dependent increase in the frequency of dicentric chromosomes was observed in the G2-PCCs up to 20 Gy of x-rays. The combined yields of dicentrics and rings in the G2-PCCs showed a clear dose dependency up to 20 Gy from 0.02/cell for 0.1 Gy to 14.98/cell for 20 Gy. Centric rings were observed more frequently than acentric ring chromosomes in the G2-PCCs at all the radiation doses from 1 Gy to 20 Gy. A head-to-head comparison was also performed by FISH on the yields of chromosome aberrations induced by different doses of x-rays (0 Gy -7.5 Gy) in colcemid arrested metaphase chromosomes and calyculin A induced G2-PCCs. In general, the frequencies of dicentrics, rings and acentric fragments were slightly higher in G2-PCCs than in colcemid arrested metaphase chromosomes at all the radiation doses, but the differences were not statistically significant. To reduce the turnaround time for absorbed radiation dose estimation, attempt was made to obtain G2-PCCs by reducing the culture time to 36 hrs. The absorbed doses estimated in x-rays irradiated (0,1,2 and 4 Gy) G2-PCCs after 36 hrs of culture were grossly like that of G2-PCCs and colcemid arrested metaphase chromosomes prepared after 48 hrs of culture. Our study indicates that the shortened version of calyculin A induced G2-PCC assay coupled with the FISH staining technique can serve as an effective triage biodosimetry tool for large-scale radiological/nuclear incidents.

Science & Technology - Other Topics↗

Non-contact Real-time Target Health Monitor

Targets are an essential part of many accelerator-based experiments, yet their constant radiation exposure eventually affects their internal structure and, consequently, their properties. Current methods typically involve either direct contact with the target or complete removal of the system, which may not be the most efficient for assessing radiation damage. For this reason, a system has been proposed that will monitor a target s radiation damage without the need for direct contact or removal. This sensor will achieve this by measuring the reflectivity of S- and P-polarized waves, which are expected to change measurably due to radiation-induced alterations. As is commonly done, smaller-scale tests were performed to ensure that the necessary equipment was functioning correctly. Once all equipment is tested, the next step will be to perform reflectivity measurements using a tungsten sample, a material often used in targets. Longer-term work will involve scaling up the system and implementing higher-energy beams. This sensor will enable a more comprehensive study of radiation damage in materials and is being considered for projects such as Mu2e, Mu2e-II, LBNF, AMF, and muon colliders.

Agosto Reyes, Alanice↗

Non-contact Real-time Target Health Monitor

Targets are an essential part of many accelerator-based experiments, yet their constant radiation exposure eventually affects their internal structure and, consequently, their properties. Current methods typically involve either direct contact with the target or complete removal of the system, which may not be the most efficient for assessing radiation damage. For this reason, a system has been proposed that will monitor a target s radiation damage without the need for direct contact or removal. This sensor will achieve this by measuring the reflectivity of S- and P-polarized waves, which are expected to change measurably due to radiation-induced alterations. As is commonly done, smaller-scale tests were performed to ensure that the necessary equipment was functioning correctly. Once all equipment is tested, the next step will be to perform reflectivity measurements using a tungsten sample, a material often used in targets. Longer-term work will involve scaling up the system and implementing higher-energy beams. This sensor will enable a more comprehensive study of radiation damage in materials and is being considered for projects such as Mu2e, Mu2e-II, LBNF, AMF, and muon colliders.

Agosto Reyes, Alanice↗

Low Energy Muon Beam Diagnostics - Scintillating Fiber Profile Monitor (SFPM)

The MeV Test Area (MTA) houses the 400 MeV H^− Beam at the end of the Linac and a secondary beamline of muons and pions created from hitting a Tungsten target. The MTA is in the Irradiation Test Area (ITA), where experiments involve studying the effects of radiation on materials in the MTA beam. There is a need for a retractable detector to monitor the secondary beam s intensity and coarse profile. The SFPM was chosen when considering factors like ability to measure low rates and handle high intensities. The plan was to test different scintillating fibers & Silicon Photomultiplier (SiPM) models to figure out which combination gives the best signals, and gain familiarity with the detector assembly, operation, and data acquisition software before using with final detectors in beamline. The SiPM circuit has been tested with a LED pulser successfully. The immediate steps that follow will be to set the SiPM up on the monitor with three different types of optical fibers, use the Caen software to configure the best mode of data acquisition, and proceed with an offline source test using Strontium-90. Once the most efficient measurement method is clear, they will be ready for use in the beamline.

Leith, Justin↗

Low Energy Muon Beam Diagnostics: Scintillating Fiber Profile Monitor

The MeV Test Area (MTA) houses the 400 MeV H- Beam at the end of the Linac and a secondary beamline of muons and pions created from hitting a Tungsten target. The MTA is in the Irradiation Test Area (ITA), where experiments involve studying the effects of radiation on materials in the MTA beam. There is a need for a retractable detector to monitor the secondary beam’s intensity and coarse profile. The SFPM was chosen when considering factors like ability to measure low rates and handle high intensities. The plan was to test different scintillating fibers & Silicon Photomultiplier (SiPM) models to figure out which combination gives the best signals, and gain familiarity with the detector assembly, operation, and data acquisition software before using with final detectors in beamline. The SiPM circuit has been tested with a LED pulser successfully. The immediate steps that follow will be to set the SiPM up on the monitor with three different types of optical fibers, use the Caen software to configure the best mode of data acquisition, and proceed with an offline source test using Strontium-90. Once the most efficient measurement method is clear, they will be ready for use in the beamline.

Leith, Justin↗

Representing Fine‐Scale Topographic Effects on Surface Radiation Balance in Hyper‐Resolution Land Surface Models

Land surface models are increasingly used to simulate land surface processes at hyper-spatial resolutions (e.g., ∼1 km). As model resolution increases, grid-scale topographic effects on surface radiation fluxes and their interactions between adjacent grids become more pronounced. However, current land surface models routinely neglect the fine-scale topographic effects on surface radiation balance. This study developed physically-based and computationally-efficient parameterizations (fineTOP) that explicitly resolve fine-scale topographic effects on downward shortwave and longwave radiation as well as land surface radiative properties. The newly developed parameterizations were implemented and tested in the Energy Exascale Earth System Model (E3SM) Land Model (ELM). Multi-decadal km-resolution ELM simulations over the California Sierra Nevada show that fine-scale topography significantly impacts the surface energy balance and snow processes across seasons. Slope determines the magnitude of topographic effects, while aspect controls their sign. For slopes larger than 30°, topography-induced change in annual surface temperature can be as large as 3.3 K. Regionally, the mean value and standard deviation of topography-induced changes in annual surface temperature are −0.22 ± 0.38 K and +0.25 ± 0.37 K over north-facing and south-facing slopes, respectively. Topography-induced changes in surface radiative properties account for 3.5% ± 13.8% of total topographic effects on annual net radiation. With fineTOP, ELM captures the aspect-dependence of snow cover fraction, snow water equivalent, and land surface temperature found in MODIS satellite observations and a snow reanalysis data set, while the default ELM fails to capture this phenomenon. The enhanced capability to represent fine-scale topographic effects on surface radiation balance can be used to advance understanding of the role of fine-scale topography in land surface processes and land-atmosphere interactions over mountainous regions.

Hao, Dalei [Pacific Northwest National Laboratory ↗

Test capsules for measuring a change in at least one property of a material, and related methods

A test capsule for measuring at least one property of a material exposed to nuclear radiation comprises a lattice structure configured to exhibit a change in at least one property responsive to exposure to nuclear radiation. The lattice structure comprises a first strut and a second strut connected to the first strut at a node. Related test capsules and methods are also described.

Roach, Robert A.↗

Gamma, electron beam and X-ray irradiation effects on polymers in an advanced bone cement mixer device

The medical device industry has been investigating ways to increase the use of alternatives to cobalt-60 gamma radiation and ethylene-oxide gas sterilization, such as electron beam (E-beam) and X-ray radiation, due to regulatory and market pressures. One impediment to switching to E-beam or X-ray technology for sterilization is the lack of data on the effects of these radiation sources on medical device polymers. To provide such data this work considers irradiation and testing of a common single-use medical bone cement mixing system, the Stryker Advanced Cement Mixer (ACM®), that is composed of seven polymer materials. The ACM® devices considered here were processed to sterilization-relevant doses (15, 25, 50, and 70 kGy) using three radiation technologies: gamma, E-beam, and X-ray. The system and its polymer components were tested for product functionality, as well as mechanical and visual properties to determine how exposure effects may be influenced by radiation technology and dose level. We found that although there were instances of statistically significant differences in effects between the gamma-irradiated products and those irradiated with E-beam and X-ray, those effects were negligible in terms of retained functionality of the product and retained mechanical properties of the polymer components. Overall, results of this study demonstrate that, for of the effects studied, E-beam and X-ray are viable alternatives to cobalt-60 gamma radiation for sterilization of the polymer-based device investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ku-band electron linac for battery-powered hand-portable 2-MeV X-ray generator

X-ray generators, producing radiation in MeV range, are a critical tool for radiography, non-destructive testing and security applications. Field operation of such source requires them to be hand-portable, autonomous and allow parameter adjustability. RF linear accelerators can serve as a flexible, reliable, and robust radiation generator alternative to dangerous radioisotopes and bulky betatrons that are currently used for field radiography if their size, weight, cost, and imaging performance are matched to these sources. Here, in this paper, we present the design and test results of a 2 MeV Ku-band electron linac for a hand-portable X-ray generator system for field radiography being developed by RadiaBeam. The dramatic scale of miniaturization and cost-reduction is achieved thanks to the implementation of innovative technologies such as air-cooled Ku-band air-traffic control magnetrons, a split accelerating structure fabrication technique, and solid-state Marx modulators. This paper presents the design of the first prototype of the accelerator, its operation from Li-Ion batteries, as well as high-power and beam measurements.

43 PARTICLE ACCELERATORS↗

Assessing the viability of a new subsize tensile specimen geometry for evaluation of structural nuclear and additively manufactured materials

The use of subsize specimens in nuclear materials testing has been a subject of ongoing interest due to radiation safety concerns and resource conservation needs. It is also of interest in additive manufacturing (AM), also known as 3D-printing, as subsize specimens can more accurately represent the behavior of the small, intricate geometries often produced using AM. A novel, extremely small geometry, called the Subsize Teeny (SST) was recently developed and is of interest for implementation. Given its extraordinarily small size and the complexities associated with subsize specimen testing, adequate vetting of this geometry is necessary to ensure data quality. Here, a variety of unirradiated nuclear structural materials were tested in the SST geometry and compared against the well-established SSJ3 geometry. In addition, two case studies implementing the SST as a screening geometry for AM materials were also conducted. The question of SST viability was found to be highly nuanced and will often be dependent on the context or application in question. It was determined, however, that the SST is a largely invalid geometry for exceptionally coarse-grained materials or in cases where the physical defect volume equals or exceeds 0.1 % or where the specimen machining parameters result in significant surface alterations. On the other hand, it was determined that the SST may be employed with confidence if the test material is nearly or totally free of physical defects, isotropic, demonstrates homogeneous plastic deformation, and possesses a fine-grained, nearly or totally homogeneous microstructure with at least twelve slip systems.

Additive manufacturing↗

Directional, joule per steradian THz pulses from multi-joule laser irradiation of wires

We report on THz pulses with energy flux exceeding 2.5 J/sr and high directionality, generated from picosecond, joule laser irradiation of microwires. The impact of wire diameter, length, and laser irradiation orientation is explored with the irradiation of 160 μm diameter, 750 μm, sharpened wires at the dull base found to produce the highest energy and shortest wavelength THz pulses among the targets tested. A traveling wave antenna combined with coherent transition radiation model is developed to explain the emission pattern, pulse energy, and spectrum seen.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gravitational wave spectrum of chain inflation

Chain inflation is an alternative to slow-roll inflation in which the inflaton tunnels along a large number of consecutive minima in its potential. In this work we perform the first comprehensive calculation of the gravitational wave (GW) spectrum of chain inflation. In contrast to slow-roll inflation the latter does not stem from quantum fluctuations of the gravitational field during inflation, but rather from the bubble collisions during the first-order phase transitions associated with vacuum tunneling. Our calculation is performed within an effective theory of chain inflation which builds on an expansion of the tunneling rate capturing most of the available model space. The effective theory can be seen as chain inflation’s analog of the slow-roll expansion in rolling models of inflation. The near scale-invariance of the scalar power spectrum translates to a quasiperiodic shape of the inflaton potential in chain inflation, with the tunneling rate changing very slowly during the e-folds leading to cosmic microwave background observables. We show that chain inflation produces a very characteristic double-peak GW spectrum: a faint high-frequency peak associated with the gravitational radiation emitted during inflation, and a strong low-frequency peak associated with the graceful exit from chain inflation (marking the transition to the radiation-dominated epoch). There exist very exciting prospects to test the gravitational wave signal from chain inflation at the aLIGO-aVIRGO-KAGRA network, at LISA and /or at pulsar timing array experiments. A particularly intriguing possibility we point out is that chain inflation could be the source of the stochastic gravitational wave background recently detected by NANOGrav, PPTA, EPTA, and CPTA. We also show that the gravitational wave signal of chain inflation is often accompanied by running/ higher running of the scalar spectral index to be tested at future cosmic microwave background experiments. Published by the American Physical Society 2024

Freese, Katherine↗

Advanced Test Reactor Neutron Dosimetry Report - 173B (Rev. 1)

Results of neutron dosimetry measurements in ATR for cycle 173B-1&2 are presented. Cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

173B↗

Promoting the regulatory acceptance of combined ion and neutron irradiation for material degradation in nuclear reactors

The Advanced Materials and Manufacturing Technologies (AMMT) program within the Department of Energy (DOE) Office of Nuclear Energy has developed its current recommendation for promoting the use of combined ion irradiation and neutron irradiation for the accelerated qualification of materials to be deployed in nuclear reactors. This plan is intended to provide a collaborative path forward that can be adopted by academia, national laboratories, and industry, and has been developed with input from the regulatory research arm of the U.S. Nuclear Regulatory Commission (NRC). To deploy new materials or materials manufactured with new technologies, such as additive manufacturing, materials must be evaluated for reactor-induced degradation from the combination of harsh temperatures, corrosive environments, and radiation fields. However, rapid deployment of materials necessitates accelerated testing methods rather than relying on years of neutron irradiation in a material test reactor. Ion irradiation has demonstrated success in reproducing material microstructure and select property evolution resulting from neutron irradiation with three to four orders of magnitude reduction in time and cost, making it an ideal candidate for accelerated irradiation testing. This presentation provides context governing both the scientific and regulatory aspects of the proposed goal. The discussion is aimed at a broad audience including researchers from industry, national laboratories, and academia. The recommended path forward is presented as a conceptual framework of specific steps. In brief, the strategy entails developing an integrated ion and neutron irradiation test plan for the material property of interest based on the fundamental tenet of the linkage of microstructure and properties in materials. Physics-based modeling interprets ion irradiation data and predicts neutron irradiation microstructure and properties with uncertainty bounds. The first round of testing is sufficient for an initial licensing application using a risk-informed approach, while a minimum required neutron irradiation test plan reduces cost and time requirements. A surveillance program with witness specimens in-reactor provides additional data over time to improve model predictions to higher damage levels and further reduce uncertainty bounds, which can be used for license extensions or longer lifetimes in new license applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced Test Reactor Neutron Dosimetry Report - Cycle 175B-1

Results of neutron dosimetry measurements in ATR for cycle 175B-1 are presented. A single set of cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

175B↗