Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiator Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

3D Virtual Simulation for Radiation Safety and Survey Training

3D virtual technologies have been widely used in remote training. Training integrated with 3D visualization technologies can enhance students’ engagement and reduce cost. The Applied Visualization Lab collaborates with College of Eastern Idaho on creating a 3D desktop application that simulate a pipe environment for radiation safety and survey training. Students can learn to perform radiation and contamination surveys remotely on their desktop. This simulation provides random scenarios, guided instructions, user interactions, and visual and sound feedback. It will promote utilizing virtual training for education outreach and minimize radiation and contamination exposure during the training.

3D↗

3D Virtual Simulation for Radiation Safety and Survey Training

3D virtual technologies have been widely used in remote training. Training integrated with 3D visualization technologies can enhance students’ engagement and reduce cost. The Applied Visualization Lab collaborates with College of Eastern Idaho on creating a 3D desktop application that simulate a pipe environment for radiation safety and survey training. Students can learn to perform radiation and contamination surveys remotely on their desktop. This simulation provides random scenarios, guided instructions, user interactions, and visual and sound feedback. It will promote utilizing virtual training for education outreach and minimize radiation and contamination exposure during the training.

3D↗

WoRDMAp Outbrief: Workshop on Radiation Detection Materials [Slides]

Project Goal: Identify pathway to reliably grow and fabricate high-performance radiation detectors for use in a variety of nonproliferation applications. 1. Create 3 working groups (semiconductors, inorganic and organic scintillators) that bring together international R&D subject-matter experts (national laboratories, industry, and academia), end users, and mission stakeholders 2. Reach expert consensus views regarding current materials related technology gaps and define prioritized R&D directions required to resolve these gaps 3. Envisage the future state of next-generation radiation detection materials and quantify the benefits to nuclear security applications 4. Provide a comprehensive expert report to DNN R&D program office to serve as roadmap with recommendations for future high-impact office investment in radiation-detection materials development

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contamination effects on Space Station Freedom electric power system performance

One design issue for Space Station Freedom (SSF) is the potential performance decrease of the electric power system (EPS) solar arrays and radiators as a result of contamination on sensitive surfaces. The authors discuss SSF potential contamination sources and contamination effects on the solar array and radiator performance due to these sources. With these contamination consideration, the SSF EPS is designed for the induced contamination environment at an optimal cost. The efforts on contamination protection and control are undergoing continual update because of the changes in the SSF configuration and in the contamination requirements, and observations from recent flight and laboratory test data are continuously being incorporated into the design.

Lu, Cheng-Yi↗

Lessons Learned Using COTS Electronics for the International Space Station Radiation Environment

The mantra of 'Faster, Better, Cheaper' has to a large degree been interpreted as using Commercial Off-the-Shelf (COTS) components and/or circuit boards. One of the first space applications to actually use COTS in space along with radiation performance requirements was the Expedite the Processing of Experiments to Space Station (EXPRESS) Rack program, for the International Space Station (ISS). In order to meet the performance, cost and schedule targets, military grade Versa Module Eurocard (VME) was selected as the baseline design for the main computer, the Rack Interface Controller (RIC). VME was chosen as the computer backplane because of the large variety of military grade boards available, which were designed to meet the military environmental specifications (thermal, shock, vibration, etc.). These boards also have a paper pedigree in regards to components. Since these boards exceeded most ISS environmental requirements, it was reasoned using COTS mid-grade VME boards, as opposed to designing custom boards could save significant time and money. It was recognized up front the radiation environment of ISS, while benign compared to many space flight applications, would be the main challenge to using COTS. Thus in addition to selecting vendors on how well their boards met the usual performance and environmental specifications, the board's parts lists were reviewed on how well they would perform in the ISS radiation environment. However, issues with verifying that the available radiation test data was applicable to the actual part used, vendor part design changes and the fact most parts did not have valid test data soon complicated board and part selection in regards to radiation.

Blumer, John H.↗

Preliminary analysis of a radiobiological experiment for LifeSat

With the possibility of performing radiation life science experiments on a dedicated satellite (LifeSat) in space, a combined effort in radiation physics and radiation dosimetry, in addition to radiation biology, is clearly required to ensure that meaningful biological experiments can be performed. To better understand the relationship of these disciplines, some possible LifeSat missions are examined. As a trial biological system, tumorigenesis is considered in the Harderian gland of mice, a system of sufficient radiosensitivity for which relative biological effectiveness (RBE) is well defined by laboratory experiments.

Wilson, John W.↗

Radiative Transfer and Retrievals in EOF Domain

The Infrared Atmospheric Sounding Interferometer (IASI) is a hyperspectral sensor with 8461 spectral channels and a nominal spectral resolution of 0.25 cm(sup -1). It is computationally intensive to perform radiative transfer calculations and inversions using all these channels. We will present a Principal Component-based Radiative Transfer Model (PCRTM) and a retrieval algorithm which perform all the necessary calculations in EOF domain. Since the EOFs are orthogonal to each other, only about 100 principal components are needed to represent the information content of the 8461 channels. The PCRTM provides the EOF coefficients and associated derivatives with respect to atmospheric and surface parameters needed by the inversion algorithm. The inversion algorithm is based on a non-linear Levenberg-Marquardt method with climatology covariance and a priori information as constraints. The retrieved parameters include atmospheric temperature, moisture and ozone profiles, cloud parameters, surface skin temperature, and surface emissivities. To make the retrieval system even more compact and stable. The atmospheric vertical profiles are compressed into the EOF space as well. The surface emissivities are also compressed into EOF space.

Liu, Xu↗

Summary of ionizing radiation analysis on the Long Duration Exposure Facility

The Ionizing Radiation Special Investigation Group (IRSIG) for the Long Duration Exposure Facility (LDEF) was established to perform radiation measurements and analysis not planned in the original experiments, and to assure availability of LDEF analysis results in a form useful to future missions. The IRSIG has organized extensive induced radioactivity measurements throughout LDEF, and a comprehensive program to compare the LDEF radiation measurements to values calculated using environment models. The activities and present status of the Group is described. The ionizing radiation results presented is summarized.

Parnell, T. A.↗

A cermet fuel reactor for nuclear thermal propulsion

Work on the cermet fuel reactor done in the 1960's by General Electric (GE) and the Argonne National Laboratory (ANL) that had as its goal the development of systems that could be used for nuclear rocket propulsion as well as closed cycle propulsion system designs for ship propulsion, space nuclear propulsion, and other propulsion systems is reviewed. It is concluded that the work done in the 1960's has demonstrated that we can have excellent thermal and mechanical performance with cermet fuel. Thousands of hours of testing were performed on the cermet fuel at both GE and AGL, including very rapid transients and some radiation performance history. We conclude that there are no feasibility issues with cermet fuel. What is needed is reactivation of existing technology and qualification testing of a specific fuel form. We believe this can be done with a minimum development risk.

Kruger, Gordon↗

CTRANS: A Monte Carlo program for radiative transfer in plane parallel atmospheres with imbedded finite clouds: Development, testing and user's guide

The program called CTRANS is described which was designed to perform radiative transfer computations in an atmosphere with horizontal inhomogeneities (clouds). Since the atmosphere-ground system was to be richly detailed, the Monte Carlo method was employed. This means that results are obtained through direct modeling of the physical process of radiative transport. The effects of atmopheric or ground albedo pattern detail are essentially built up from their impact upon the transport of individual photons. The CTRANS program actually tracks the photons backwards through the atmosphere, initiating them at a receiver and following them backwards along their path to the Sun. The pattern of incident photons generated through backwards tracking automatically reflects the importance to the receiver of each region of the sky. Further, through backwards tracking, the impact of the finite field of view of the receiver and variations in its response over the field of view can be directly simulated.

Source record↗

Application of MORSE to radiation analysis of nuclear flight propulsion modules

Several modifications and additions were made to the multigroup Monte Carlo code (MORSE) to implement its use in a computational procedure for performing radiation analyses of NERVA nuclear flight propulsion modules. These changes include the incorporation of a new general geometry module; the inclusion of an expectation tracklength estimator; and the option to obtain source information from two-dimensional discrete ordinates calculations. Computations comparing MORSE and a point cross section Monte Carlo code, COHORT, were made in which a coupled discrete ordinates/Monte Carlo procedure was used to calculate the gamma dose rate at tank top locations of a typical propulsion module. The dose rates obtained from the MORSE computation agreed with the dose rates obtained from the COHORT computation to within the limits of the statistical accuracy of the calculations.

Woolson, W. A.↗

SP-100 high-temperature advanced radiator development

The development of an advanced radiator concept design meeting SP-100 thermoelectric requirements is reported. Carbon-carbon heat pipes are used to produce this lightweight, high-performance radiator. Two feasibility problems had to be solved to enable the design: the production of a carbon-carbon heat pipe tube with integral fins, and the development of a coating that protects the carbon-carbon substrate from 875-K potassium working fluid. Carbon-carbon tubes with integral fins were successfully produced using a T-300 fiber, an angle interlocking weave architecture, and pitch densification. A barrier coating to protect the inside diameter of these tubes which employed the CVD of niobium over a thin rhenium interlayer was developed. The rhenium interlayer proved to be critical to the success of this coating technique by providing a gradation in the coefficient of thermal expansion, carrying a portion of the induced stress load, improving coating adhesion, and providing a partial carbon diffusion barrier.

Rovang, Richard D.↗

Experimental measurement and computer analysis of stray radiation in a telescope

A description is presented of an experimental measurement system for the study of the stray radiation performance of a 50-cm aperture astronomical telescope model. The model incorporates a very high performance baffle system. To simulate the space environment of the actual orbiting telescope, the telescope model was placed in a vacuum chamber. The stray radiation source for the experiment was a ruby laser system. A photomultiplier tube was used for the detector. A minicomputer system was used to control the experiment and to gather and process the data. A computer program was used to model the telescope baffle system. Experimentally and analytically determined stray radiation attenuation data are compared.

Hunt, G. H.↗