Search NASA⌕ Search

SEARCH · Search NASA

Results for “Raman spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Laser Rayleigh and Raman Diagnostics for Small Hydrogen/oxygen Rockets

Localized velocity, temperature, and species concentration measurements in rocket flow fields are needed to evaluate predictive computational fluid dynamics (CFD) codes and identify causes of poor rocket performance. Velocity, temperature, and total number density information have been successfully extracted from spectrally resolved Rayleigh scattering in the plume of small hydrogen/oxygen rockets. Light from a narrow band laser is scattered from the moving molecules with a Doppler shifted frequency. Two components of the velocity can be extracted by observing the scattered light from two directions. Thermal broadening of the scattered light provides a measure of the temperature, while the integrated scattering intensity is proportional to the number density. Spontaneous Raman scattering has been used to measure temperature and species concentration in similar plumes. Light from a dye laser is scattered by molecules in the rocket plume. Raman spectra scattered from major species are resolved by observing the inelastically scattered light with linear array mounted to a spectrometer. Temperature and oxygen concentrations have been extracted by fitting a model function to the measured Raman spectrum. Results of measurements on small rockets mounted inside a high altitude chamber using both diagnostic techniques are reported.

Degroot, Wilhelmus A.↗

Effects of He Ion Irradiation in Simple Borosilicate Glasses for HLW Immobilisation - 20324

High-level radioactive waste (HLW) consists of fission products and minor actinides. Borosilicate glass is the host material of choice in most countries to safely immobilize HLW, followed by eventual geological disposal. HLW glasses will experience both self-heating and self-irradiation effects due to the decay of fission products and minor actinides present therein. During the first 500 years of geological disposal, beta-gamma decay will be the main source of radiation due to short half-lives of fission products, as compared to very long-lived actinides which will be responsible for irradiation over much longer timescales. High-energy alpha particles and alpha recoil nuclei can potentially have significant impact (stored energy, volume change, accumulated dose, chemical durability) on the performance of the wasteform over longer timescales. Thus, to ensure safe and economic disposal over geological periods (10{sup 4} - 10{sup 6} years), the assessment of performance and properties in terms of radiation effects becomes indispensable. This work aims to simulate the effects of alpha decay in radioactive waste glasses. Two international glasses, namely UK 'MW' lithium-sodium borosilicate and Indian sodium-barium borosilicate, which are being used as HLW immobilization matrices by the UK and India respectively, were prepared by a melt-quench method and annealed below their glass transition temperatures. Both glasses were irradiated with 650 KeV He{sup 2+} ions with doses ranging from 10{sup 15} to 10{sup 17} ions/cm{sup 2}. Structural analysis was carried out using electron paramagnetic resonance (EPR) and Raman spectroscopies. First derivative continuous wave EPR spectra were recorded for all pristine and irradiated glass monoliths at room temperature using an X-band (frequency 9.6 GHz) EPR Bruker spectrometer. Results from EPR analyses showed the formation of irradiation induced paramagnetic centers at g ∼ 2.00 in all irradiated glasses. Raman spectra of pristine and irradiated samples were acquired, and showed notable changes in glass structure post-irradiation, with the emergence of a broad Raman band at 1560 cm{sup -1} upon irradiation with high fluences. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The SuperCam Instrument Suite on the NASA Mars 2020 Rover: Body Unit and Combined System Tests

The SuperCam instrument suite provides the Mars 2020 rover, Perseverance, with a number of versatile remote-sensing techniques that can be used at long distance as well as within the robotic-arm workspace. These include laser-induced breakdown spectroscopy (LIBS), remote time-resolved Raman and luminescence spectroscopies, and visible and infrared (VISIR; separately referred to as VIS and IR) reflectance spectroscopy. A remote micro-imager (RMI) provides high-resolution color context imaging, and a microphone can be used as a stand-alone tool for environmental studies or to determine physical properties of rocks and soils from shock waves of laser-produced plasmas. SuperCam is built in three parts: The mast unit (MU), consisting of the laser, telescope, RMI, IR spectrometer, and associated electronics, is described in a companion paper. The on-board calibration targets are described in another companion paper. Here we describe SuperCam’s body unit (BU) and testing of the integrated instrument. The BU, mounted inside the rover body, receives light from the MU via a 5.8 m optical fiber. The light is split into three wavelength bands by a demultiplexer, and is routed via fiber bundles to three optical spectrometers, two of which (UV and violet; 245–340 and 385–465 nm) are crossed Czerny-Turner reflection spectrometers, nearly identical to their counterparts on ChemCam. The third is a high-efficiency transmission spectrometer containing an optical intensifier capable of gating exposures to 100 ns or longer, with variable delay times relative to the laser pulse. This spectrometer covers 535–853 nm ( $105\text{--}7070~\text{cm}^{-1}$ Raman shift relative to the 532 nm green laser beam) with $12~\text{cm}^{-1}$ full-width at half-maximum peak resolution in the Raman fingerprint region. The BU electronics boards interface with the rover and control the instrument, returning data to the rover. Thermal systems maintain a warm temperature during cruise to Mars to avoid contamination on the optics, and cool the detectors during operations on Mars.Results obtained with the integrated instrument demonstrate its capabilities for LIBS, for which a library of 332 standards was developed. Examples of Raman and VISIR spectroscopy are shown, demonstrating clear mineral identification with both techniques. Luminescence spectra demonstrate the utility of having both spectral and temporal dimensions. Finally, RMI and microphone tests on the rover demonstrate the capabilities of these subsystems as well.

47 OTHER INSTRUMENTATION↗

Direct Observation and Analysis of Low-Energy Magnons with Raman Spectroscopy in Atomically Thin NiPS 3

van der Waals (vdW) magnets have rapidly emerged as a fertile playground for fundamental physics and exciting applications. Despite the impressive developments over the past few years, technical limitations pose a severe challenge to many other potential breakthroughs. High on the list is the lack of suitable experimental tools for studying spin dynamics on atomically thin samples. Here, Raman scattering techniques are employed to directly observe the low-lying magnon (~1 meV) even in bilayer NiPS 3 . Further, the advantage is that it offers excellent energy resolutions far better on low-energy sides than most inelastic neutron spectrometers can offer. More importantly, with appropriate theoretical analysis, the polarization dependence of the Raman scattering by those low-lying magnons also provides otherwise hidden information on the dominant spin-exchange scattering paths for different magnons. By comparing with high-resolution inelastic neutron scattering data, these low-energy Raman modes are confirmed to be indeed of magnon origin. Because of the different scattering mechanisms involved in inelastic neutron and Raman scattering, this information is fundamental in pinning down the final spin Hamiltonian. This work demonstrates the capability of Raman spectroscopy to probe the genuine two-dimensional spin dynamics in atomically thin vdW magnets, which can provide insights that are obscured in bulk spin dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Technique for Separating Raman Scattering Signals from Background Emission with Single-Shot Measurement Potential

A novel technique for extracting Q-branch Raman signals scattered by a diatomic species from the emission spectrum resulting from the irradiation of combustion products using a broadband excimer laser has been developed. This technique is based on the polarization characteristics of vibrational Raman scattering and can be used for both single-shot Raman extraction and time-averaged data collection. The Q-branch Raman signal has a unique set of polarization characteristics which depend on the direction of the scattering while fluorescence signals are unpolarized. For the present work, a calcite crystal is used to separate the horizonal component of a collected signal from the vertical component. The two components are then sent through a UV spectrometer and imaged onto an intensified CCD camera separately. The vertical component contains both the Raman signal and the interfering fluorescence signal. The horizontal component contains the fluorescence signal and a very weak component of the Raman signal; hence, the Raman scatter can be extracted by taking the difference between the two signals. The separation of the Raman scatter from interfering fluorescence signals is critically important to the interpretation of the Raman for cases in which a broadband ultraviolet (UV) laser is used as an excitation source in a hydrogen-oxygen flame and in all hydrocarbon flames. The present work provides a demonstration of the separation of the Raman scatter from the fluorescence background in real time.

Hartfield, Roy J., Jr.↗

On the Hunt for Detectable Biosignatures in Jezero Crater: What to Look for and Where

Introduction: The Perseverance rover, which is currently exploring Jezero crater on Mars, is equipped with seven instruments that allow for observation of textures, minerals, color, structure, and chemistry of rocks and sediments in order to search for signs of ancient life, understand the geologic history of the crater, and identify candidates for sample return (Farley et al. 2020). The first of these aims includes the direct detection of potential biosignatures, including textures, organic molecules, minerals, and elemental chemistries that are of biogenic origin (Mustard et al. 2013). The presence of these biosignatures will be constrained by the habitability of the local region, the preservation potential of the host rocks, and the sensitivity of the instrument suite, and their biogenicity will be investigated after return to Earth as part of the Mars Sample Return campaign. Here, we examine key targets on the three planned campaigns, potential biosignatures that may be present, and the capabilities of key rover instruments. High Potential Biosignature Sites in Jezero: To date, measurements have been made on multiple sites that both contain minerals known in terrestrial settings to preserve biosignatures and likely were habitable settings (Williford et al. 2021). Two examples include the fine-grained rocks at the base of the delta fan and the NW inner margin of the crater. Fine-grained Rocks at Base of Delta Fan. Fine-grained, clay-bearing rocks may have been deposited as muddy lake sediments that could have hosted life and preserved biosignatures settling out of the water column. The report of organic molecules by the Curiosity rover in the Sheepbed mudstone and Murray formation has highlighted this site in particular. Potential biosignatures in mudstones, especially those rich in silica (McMahon et al. 2018), microbialites and complex organics. NW Inner Margin of Crater. This unit, located along the inner margin of the crater, contains strong carbonate signatures and may have been the littoral zone of a lake (Horgan et al. 2020). The potential biosignatures here include microfossils, microbialites, biominerals, and complex organics. Detectability of Biosignatures by the Mars 2020 Instrument Suite: The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) instrument comprises a Deep UV spectrometer, context imager, and color camera to generate spatially resolved chemical maps (Bhartia et al. 2020). It is sensitive to trace organics as well as a range of minerals and can detect native fluorescence from aromatic organics; the WATSON and ACI cameras can be used to observe morphologies such as stromatolitic laminations or filaments ranging from the tens of micron to millimeter scale. SHERLOC can detect organics that may be present in either of the high potential biosignature targets, as well as detect carbonates in the latter. However, the presence of high amounts of iron, such as in iron-rich clays, would cause attenuation of spectral response through UV absorption. The Planetary Instrument for X-ray Lithochemistry (PIXL) comprises an X-ray fluorescence spectrometer and camera that can scan rock surfaces to generate elemental maps (Allwood et al. 2020). PIXL can detect chemical biosignatures such as spatial variations of elemental abundances that may have resulted from biological activity. PIXL would be particularly useful in detecting fine textures and elemental chemistries in either high potential biosignature target, but cannot directly detect minerals such as carbonate. The SuperCam instrument performs three types of spectroscopy, color imaging, and acoustic recording to remotely examine elemental composition, minerals, organics, and textures (Maurice et al. 2021). Using laser induced breakdown spectroscopy and time resolved luminescence spectroscopy, SuperCam can detect major elemental building blocks of organics (i.e., C, H, N, O, P, S) and conjugated organic structures, respectively, which may be found in either site. While in other contexts, luminescence is a useful tool for biosignature identification, luminescence generated by the 532 nm laser may obscure the Raman signal. Conclusion: The three instruments discussed can be used collaboratively to establish the presence of potential biosignatures in samples. These high-priority samples may then be returned to Earth for detailed laboratory analysis.

S. Sharma↗

Resolved rotation–vibration non-equilibrium with rotational VIPA-CARS

Simultaneous rotational and vibrational temperatures are measured in an N 2 plasma with rotational coherent anti-Stokes Raman scattering (CARS) resolved with a virtually imaged phased array (VIPA)-based spectrometer. A VIPA spectrally separates rotational transitions for each vibrational state, allowing vibrational populations to be directly measured. VIPA-CARS is shown to provide more accurate measurements of non-equilibrium temperatures than grating-resolved rotational CARS. The general characteristics, limitations, and potential uses of VIPA-CARS are discussed.

Steinmetz, S. A. (ORCID:0000000311014662)↗

Scanning tunneling microscopy studies of diamond films and optoelectronic materials

In this report, we report on progress achieved from 12/1/92 to 10/1/93 under the grant entitled 'Scanning Tunneling Microscopy Studies of Diamond Films and Optoelectronic Materials'. We have set-up a chemical vapor deposition (CVD) diamond film growth system and a Raman spectroscopy system to study the nucleation and growth of diamond films with atomic resolution using scanning tunneling microscopy (STM). A unique feature of the diamond film growth system is that diamond films can be transferred directly to the ultrahigh vacuum (UHV) chamber of a scanning tunneling microscope without contaminating the films by exposure to air. The University of North Texas (UNT) provided $20,000 this year as matching funds for the NASA grant to purchase the diamond growth system. In addition, UNT provided a Coherent Innova 90S Argon ion laser, a Spex 1404 double spectrometer, and a Newport optical table costing $90,000 to set-up the Raman spectroscopy system. The CVD diamond growth system and Raman spectroscopy system will be used to grow and characterize diamond films with atomic resolution using STM as described in our proposal. One full-time graduate student and one full-time undergraduate student are supported under this grant. In addition, several graduate and undergraduate students were supported during the summer to assist in setting-up the diamond growth and Raman spectroscopy systems. We have obtained research results concerning STM of the structural and electronic properties of CVD grown diamond films, and STM and scanning tunneling spectroscopy of carbon nanotubes. In collaboration with the transmission electron microscopy (TEM) group at UNT, we have also obtained results concerning the optoelectronic material siloxene. These results were published in refereed scientific journals, submitted for publication, and presented as invited and contributed talks at scientific conferences.

Perez, Jose M.↗

Airy light-sheet Raman imaging

Light-sheet fluorescence microscopy has greatly improved the speed and overall photostability of optically sectioning cellular and multi-cellular specimens. Similar gains have also been conferred by light-sheet Raman imaging; these schemes, however, rely on diffraction limited Gaussian beams that hinder the uniformity and size of the imaging field-of-view, and, as such, the resulting throughput rates. Here, we demonstrate that a digitally scanned Airy beam increases the Raman imaging throughput rates by more than an order of magnitude than conventional diffraction-limited beams. Overall, this, spectrometer-less, approach enabled 3D imaging of microparticles with high contrast and 1 µm axial resolution at 300 msec integration times per plane and orders of magnitude lower irradiation density than coherent Raman imaging schemes. We detail the apparatus and its performance, as well as its compatibility with fluorescence light-sheet and quantitative-phase imaging towards rapid and low phototoxicity multimodal imaging.

47 OTHER INSTRUMENTATION↗

AIRS Retrieval Validation During the EAQUATE

Atmospheric and surface thermodynamic parameters retrieved with advanced hyperspectral remote sensors of Earth observing satellites are critical for weather prediction and scientific research. The retrieval algorithms and retrieved parameters from satellite sounders must be validated to demonstrate the capability and accuracy of both observation and data processing systems. The European AQUA Thermodynamic Experiment (EAQUATE) was conducted mainly for validation of the Atmospheric InfraRed Sounder (AIRS) on the AQUA satellite, but also for assessment of validation systems of both ground-based and aircraft-based instruments which will be used for other satellite systems such as the Infrared Atmospheric Sounding Interferometer (IASI) on the European MetOp satellite, the Cross-track Infrared Sounder (CrIS) from the NPOESS Preparatory Project and the following NPOESS series of satellites. Detailed inter-comparisons were conducted and presented using different retrieval methodologies: measurements from airborne ultraspectral Fourier transform spectrometers, aircraft in-situ instruments, dedicated dropsondes and radiosondes, and ground based Raman Lidar, as well as from the European Center for Medium range Weather Forecasting (ECMWF) modeled thermal structures. The results of this study not only illustrate the quality of the measurements and retrieval products but also demonstrate the capability of these validation systems which are put in place to validate current and future hyperspectral sounding instruments and their scientific products.

Zhou, Daniel K.↗

Improving Total Column Ozone Retrievals by Using Cloud Pressures Derived from Raman Scattering in the UV

The higher spectral resolution, coverage, and sampling of the Aura satellite ozone monitoring instrument (OMI), as compared with the total ozone mapping spectrometer (TOMS) should allow for improved ozone retrievals, including estimates of tropospheric ozone. By default, the TOMS-like OMI total column ozone algorithm uses climatological cloud-top pressures based on infrared (IR) measurements to estimate the column ozone below the clouds. Alternatively, cloud pressure can be retrieved using atmospheric rotational Raman scattering with OMI. The retrieved cloud pressures should be more consistent with assumptions made in the total ozone algorithm. Here, we use data from the global ozone monitoring experiment (GOME) to estimate total ozone using both the IR-climatological and retrieved cloud pressures. The exceed approximately 15 DU. Use of the UV cloud pressure retrievals leads to a smoother distribution of ozone along a satellite track by reducing small spatial irregularities presumably caused by errors in the climatological cloud pressures.

Vasilkov, A.↗

Analysis of Raman scattered Ly-alpha emissions from the atmosphere of Uranus

A line at 1280 A, due to Raman scattering of solar Lyman alpha (Ly-alpha) in the atmosphere of Uranus, has been detected by the Voyager Ultraviolet Spectrometer. The measured intensity of 40 + or - 20 R implies that 200 R to 500 R of the measured 1500 R Ly-alpha intensity at the subsolar point is due to Rayleigh scattering of the solar line. The presence of Rayleigh and Raman scattering at 1216 A suggests that the Uranian atmosphere is largely devoid of absorbing hydrocarbons above the 0.5 mbar level. The most natural explanation of this depletion is very weak vertical mixing equivalent to an eddy coefficient on the order of 200 sq cm/sec between 0.5 mbar and 100 mbar.

Yelle, R. V.↗

Test Facilities for SHERLOC Laser Development

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) instrument is a deep UV laser based spectrometer that is part of NASA’s Mars Perseverance rover. The laser is a pulsed 248.6 nm NeCu hollow cathode gas discharge laser. The design, development, and testing of lasers and laser power supplies (LPS) were performed by scientists and engineers at the Jet Propulsion Laboratory (JPL) and Photon Systems Inc. (PSI). While these lasers had been used previously in extreme terrestrial environments, before they had to be qualified for operation and functionality over the expected range of environmental situations (temperature cycling, vibration, mechanical shock, low pressure corona emission testing) over the course of mission life time. The SHERLOC laser/LPS testing facilities consisted of custom-tailored environmental test chambers with metrology/control electronics. A custom LabVIEW software package was developed to autonomously operate all test facilities using a multi-threaded, object-oriented programming architecture, tasked with interfacing with many instruments simultaneously for operation and data acquisition.

Houck, Andrew↗

Trace Chemical Detection Using Intercalated MXenes as a Signal Enhancing Substrate in Optical Probes

MXenes are 2D materials composed of layered transition metal nitrides or carbides. These materials are synthesized by HF exfoliation from MAX phases (Ti{sub 3}AlC{sub 2}). The 2D nanomaterial was synthesized by the removal of the 'A' element, resulting in a Mxene product (Ti{sub 3}C{sub 2}). MXenes have the general formula M{sub n+1}X{sub n}T{sub x}, where M is an early transition metal, X is Carbon and/or Nitrogen, and T accounts for surface terminated functional groups such as Fluoride, hydroxyl, and oxygen. These materials have very unique properties, similar to graphene, that allows them to be applied in a variety of trace detection techniques including surface-enhanced Raman spectroscopy (SERS). MXenes have also been demonstrated to selectively uptake uranyl ion, UO{sub 2}{sup 2+}. If this property can be combined with SERS or fluorescence detection, it may be possible to use MXenes as the basis for an alternative method to kinetic phosphorescence analysis (KPA) for trace uranyl measurements. Objectives: To confirm that MXene Nano materials are suitable substrates for SERS and sensor development by enhancing Raman signaling. To determine if certain MXene preparation methods yield materials that are more suitable for trace sensing methods. To determine uranyl uptake properties of these MXene materials and test them for analytical signals. Sample Preparation: Preparation of Ti{sub 3}C{sub 2}MXene (at FSU). MXenes were prepared by etching Al from Ti{sub 3}AlC{sub 2} (MAX phase)material. Two etching techniques yield different MXene products: LiF/HCl: Milder reaction, larger MXene flakes. HF: Harsher reaction, smaller flakes, larger layer separation. Products washed to remove etchant, vacuum filtered, and dried. Dried MXene flakes are air-stable. Film preparation for sensor testing (at SRNL): Suspend powder in diH{sub 2}O, purge with Ar, sonicate for 30 min. Centrifuge and collect supernate with suspended particles. Observed LiF-etched Mxene yielded a higher density of particles and darker collected solution. Drop-cast (4 ml) supernate onto slides and dried with Ar. For Rhodamine B (RhB) testing, drop-cast 4 ml drops onto Mxene spots and dried with Ar. Scanning Electron Microscopy conditions: 10 kV Beam energy, high vacuum; Working distance of 8 mm; beam penetration depth appx. 4 microns, beam spot size appx. 2 nanometers. Results: Detection of aluminum correlates with bright spots on image. Presence of aluminum shows that LiF/HCl etching was less thorough than HF etching. Trace Cl detection in LiF images suggests incomplete rinsing. HF has smaller feature size, more layer structure, and increased homogeneity, consistent with expectations. Macroscopic Raman spectroscopy measurements: 532 nm excitation, ∼50 mW with a ∼100 micron spot size (InPhotonics RPB probe). Kaiser Optical Holospec f/1.8 spectrometer with cooled (-60 deg.C) Andor iDus OE420 CCD. LiF 1x supernate showed good signal for trace measurements of Rhodamine B. HF and 1/4x LiF supernates showed little Mxene or Rhodamine B signal. Low deposition densities led to excess background signal from glass slides. For LiF film, response is linear with Rhodamine B concentration over range tested. Will retest with Raman microscope (∼1 micron spot size) to characterize SERS of more dilute LiF and HF etched Mxenes. Conclusions: The LiF etched material was more suitable for macroscopic SERS measurements because it was more concentrated, resulting in a thicker film than the HF etched Mxene and diluted LiF sample. However, the other materials may give greater SERS enhancements, which we hope to determine from measurements with the Raman microscope. From characterization with SEM we concluded that the HF etched Mxene is more uniform/homogenous and has smaller particle size than the LiF etched Mxene. There is still aluminum present in both samples indicating that etching wasn't complete, but the removal of the aluminum was more efficient in the HF method. Path Forward: Observe SERS with Raman microscopy, to obtain better signals for the more diluted samples and be able to compare enhancement effects for the different MXenes. Characterize uranyl sorption into MXene films and test Raman and fluorescence signals. Revisit the etching conditions to improve removal of aluminum. FSU and SRNL will continue to collaborate to create and characterize different Mxene materials and test their usefulness for sensor applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Propyne: Determination of Physical Properties and Unit Cell Parameters under Titan-Relevant Conditions

With its large size, dense atmosphere, methane-based hydrological-like cycle, and diverse surface features, the Saturnian moon Titan is one of the most unique of the outer Solar System satellites. Study of the photochemically produced molecules in Titan’s atmosphere is critical in order to understand the mechanics of the atmosphere and, by extension, the interactions between atmosphere, surface, and subsurface water ocean. One example is propyne vapor, a photochemically produced species in Titan’s upper atmosphere expected to condense in Titan’s stratosphere at lower altitudes. Propyne may also be a trace species in Titan’s stratospheric co-condensed ice clouds detected by the Cassini Composite InfraRed Spectrometer. Bulk structural characterization of propyne ice is currently incomplete and is lacking in published laboratory Raman spectra and X-ray diffraction data. Here, we present a laboratory characterization of propyne ice, including the first published X-ray diffraction and Raman spectroscopy results for propyne ice.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Retrieval Studies with LIDORT

This short program of LIDORT-based research in atmospheric trace gas retrieval was conducted over the 1 year period 01 July 2002 to 30 June 2003. After consultation with the NASA reporting officer, the first of the two original proposal activities (development of a direct-fitting total O3 column retrieval algorithm with operational capability for GOME data) was replaced by other tasks. The three activities addressed were: (1) Sensitivity studies for column and profile retrieval of NO2 distributions from a new generation of multi-axis ground-based spectrometers; (2) use of the LIDORT-RRS model to determine the effect of inelastic rotational Raman scattering at SBUV wavelengths; (3) an examination of ozone profile weighting functions in the presence of optically thick tropospheric clouds.

Bhartia, P. K.↗

The far ultraviolet reflection spectrum of Uranus - Results from the Voyager encounter

The present analysis of the 1250-1700 A region Uranus spectrum obtained by Voyager's US spectrometer characterizes these observation results as due primarily to solar light reflected from an H2 Rayleigh and Raman scattering atmosphere with small but measurable hydrocarbon absorption. The hydrocarbon abundances obtained are substantially lower than those at comparable levels of the Saturn or Jupiter atmospheres; it is suggested, in one-dimensional terms, that this is due to diffusive separation, in conjunction with photochemical depletion caused by a very low eddy-diffusion coefficient. Strong latitudinal variations in the hydrocarbon abundances are suggested in the subsolar, polar stratosphere.

Yelle, Roger V.↗