Search NASA⌕ Search

SEARCH · Search NASA

Results for “Rating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Day-to-day reliability of basal heart rate and short-term and ultra short-term heart rate variability assessment by the Equivital eq02+ LifeMonitor in US Army soldiers

Introduction The present study determined the (1) day-to-day reliability of basal heart rate (HR) and HR variability (HRV) measured by the Equivital eq02+ LifeMonitor and (2) agreement of ultra short-term HRV compared with short-term HRV. Methods Twenty-three active-duty US Army Soldiers (5 females, 18 males) completed two experimental visits separated by >48 hours with restrictions consistent with basal monitoring (eg, exercise, dietary), with measurements after supine rest at minutes 20–21 (ultra short-term) and minutes 20–25 (short-term). HRV was assessed as the SD of R–R intervals (SDNN) and the square root of the mean squared differences between consecutive R–R intervals (RMSSD). Results The day-to-day reliability (intraclass correlation coefficient (ICC)) using linear-mixed model approach was good for HR (0.849, 95% CI: 0.689 to 0.933) and RMSSD (ICC: 0.823, 95% CI: 0.623 to 0.920). SDNN had moderate day-to-day reliability with greater variation (ICC: 0.689, 95% CI: 0.428 to 0.858). The reliability of RMSSD was slightly improved when considering the effect of respiration (ICC: 0.821, 95% CI: 0.672 to 0.944). There was no bias for HR measured for 1 min versus 5 min (p=0.511). For 1 min measurements versus 5 min, there was a very modest mean bias of −4 ms for SDNN and −1 ms for RMSSD (p≤0.023). Conclusion When preceded by a 20 min stabilisation period using restrictions consistent with basal monitoring and measuring respiration, military personnel can rely on the eq02+ for basal HR and RMSSD monitoring but should be more cautious using SDNN. These data also support using ultra short-term measurements when following these procedures.

General & Internal Medicine↗

Bit error rate measurement above and below bit rate tracking threshold

Bit error rate is measured by sending a pseudo-random noise (PRN) code test signal simulating digital data through digital equipment to be tested. An incoming signal representing the response of the equipment being tested, together with any added noise, is received and tracked by being compared with a locally generated PRN code. Once the locally generated PRN code matches the incoming signal a tracking lock is obtained. The incoming signal is then integrated and compared bit-by-bit against the locally generated PRN code and differences between bits being compared are counted as bit errors.

Kobayaski, H. S.↗

Dielectronic recombination rates, ionization equilibrium, and radiative emission rates for calcium and nickel ions in low-density high-temperature plasmas

The total dielectronic recombination rates for Ca and Ni ions were calculated taking into account autoionization to excited states of the recombining ion and stabilizing radiative transitions of the recombining electron. Radiative transitions of the recombining ion are found to be the dominant stabilizing processes, and the relative importance of Delta n = 0 and Delta n not equal to 0 transitions in the relevant temperature region is determined for each ion. The relative importance of the Delta n = 0 and Delta n not equal to 0 contributions is significantly altered for some ions by the inclusion of autoionization to excited levels. The relative abundance of the various ionization stages has been determined by using a corona equilibrium model in which collisional ionization and inner-shell excitation followed by autoionization are balanced by direct radiative and dielectronic recombination.

Jacobs, V. L.↗

Dielectronic recombination rates, ionization equilibrium, and radiative emission rates for Mn ions in low-density high-temperature plasmas

The analysis of optically-thin far-ultraviolet and X-ray emission lines of multiply-charged ions is one of the basic methods for determining the temperatures and densities of laboratory and astrophysical plasmas. In addition, the energy balance in these plasmas can be significantly influenced by the emission of radiation from relatively low concentrations of multiple-charged atomic ions. Because the populations of the excited levels are expected to depart substantially from their local thermodynamic equilibrium values a detailed treatment of the elementary collisional and radiative processes must be employed in order to predict the emission line intensities. In this investigation the authors present the results of calculations based on a corona equilibrium model in which a detailed evaluation is made of the dielectronic recombination rate coefficients. The ionization and autoionization following inner-shell electron excitation from each ground state are balanced by direct radiative and dielectronic recombination. The spectral line intensities emitted by the low-lying excited states, which are assumed to undergo spontaneous radiative decay in times that are short compared with the collision time, are evaluated in terms of the corona ionization equilibrium distributions of the ground states and their electron-impact excitation states.

Jacobs, V. L.↗

Calculated ionization rates, ion densities, and airglow emission rates due to precipitating electrons in the nightside ionosphere of Mars

The calculations presented in this paper clearly establish that the electron fluxes measured by the HARP instrument, carried on board Phobos 2, could cause significant electron impact ionization and excitation in the nightside atmosphere of Mars, if these electrons actually do precipitate. The calculated peak electron densities were found to be about a factor of 2 larger than the mean observed nightside densities, indicating that if a significant fraction of the measured electrons actually precipitate, they could be the dominant mechanism responsible for maintaining the nightside ionosphere. The calculated zenith column emission rates of the O I 5577-A and 6300-A and CO Cameron band emissions, due to electron impact and dissociative recombination mechanisms, were found to be significant.

Haider, S. A.↗

The Gaseous Explosive Reaction : the Effect of Pressure on the Rate of Propagation of the Reaction Zone and upon the Rate of Molecular Transformation

This study of gaseous explosive reaction has brought out a number of important fundamental characteristics of the explosive reaction indicating that the basal processes of the transformation are much simpler and corresponds more closely to the general laws and principles of ordinary transformations than is usually supposed. The report calls attention to the point that the rate of molecular transformation within the zone was found in all cases to be proportional to pressure, that the transformation within the zone is the result of binary impacts. This result is of unusual interest in the case of the reaction of heavy hydrocarbon fuels and the reaction mechanism proposed by the recent kinetic theory of chain reactions.

Stevens, F W↗

Recommendations for UAS Crew Ratings. Pilot Ratings and Authorization Requirements for UAS

This position paper is intended to recommend the minimum certificate and rating requirements for a pilot to operate an Unmanned Aircraft System (UAS) in the National Airspace System. The paper will recommend the minimum requirements based on the Knowledge, Skills, and Abilities (KSA) required of a UAS pilot and show how those compare to the KSAs required by regulation for manned-aircraft pilots. The paper will provide substantiation based on studies conducted using analyses, simulation and flight experience. The paper is not yet complete; only initial working material is included. The material provided describes the body of work completed thus far and the plan for remaining tasks to complete the recommendation. The HSI Pilot KSA document provides an analysis of the knowledge, skills, and abilities required for UAS operation in the NAS. It is the source document used for the position paper.

Source record↗

Method for controlling fiber growth in a laser heated pedestal growth system by controlling a laser power output, a pedestal feedstock rate of motion, and a draw rate

One or more embodiments relate to a method for controlling fiber growth and fiber diameter in a laser heated pedestal growth (LHPG) system so as to provide long, continuous single-crystal optical fibers of uniform diameter. The method generally provides three independent parameter feedback controls to control the molten zone height, laser power, and fiber drawing rates simultaneously in order to reduce the mismatch between instantaneous diameter changes and current diameter. The method permits the growth of fibers with non-uniform diameters along the fiber's length. The method also provides the capability to stop the LHPG system, remove the exhausted pedestal feedstock with a second pedestal feedstock, and restart the LHPG system to provide a continuous fiber.

Buric, Michael P.↗

Impact of High-Dose-Rate and Low-Dose-Rate Brachytherapy Boost on Toxicity, Functional and Cancer Outcomes in Patients Receiving External Beam Radiation Therapy for Prostate Cancer: A National Population-Based Study

External beam radiation therapy (EBRT) with brachytherapy boost reduces cancer recurrence in patients with prostate cancer compared with EBRT monotherapy. However, randomized controlled trials or large-scale observational studies have not compared brachytherapy boost types directly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗