Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reactivity Control System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗

A review on protection challenges of Transmission Lines connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses.

14 SOLAR ENERGY↗

A Review on Protection Challenges of Transmission Lines Connected to Inverter-Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses

14 SOLAR ENERGY↗

Evaluation of Oak Ridge National Laboratory Health Physics Research Reactor Operation Data for Critical Benchmark Creation [Abstract]

The Oak Ridge National Laboratory (ORNL) Health Physics Research Reactor (HPRR) was a research reactor designed and built at ORNL in 1961. The critical assembly was using a highly enriched uranium and molybdenum alloy as the fuel, and it could be operated in steady-state or burst modes. The reactor was used for about 25 years to produce a lot of publications related to dosimetry, radiobiology and radiation detectors testing before its decommissioning in 1987. In recent years, the idea of using legacy operation data from the to create a valuable critical accident alarm system shielding benchmark arose. Such a benchmark has been submitted to the International Criticality Safety Benchmark Experiment Project (ICSBEP) Technical Review Group for a potential inclusion in the 2022 version of the handbook. Another way to use the valuable data from the operation of the HPRR is to evaluate the feasibility of the creation of a subcritical or prompt supercritical benchmark for inclusion in the ICSBEP or the International Reactor Physics Experiments Evaluation Project (IRPhEP) handbooks. To initiate a burst, the HPRR had to be operated in a slightly subcritical state for a few minutes. Then, the insertion of the burst control rod would greatly increase the reactivity of the system and start the burst. No critical configuration of the HPRR critical assembly could be located. The only information available concerns stable subcritical and prompt supercritical states, found in a burst experiments’ logbook. In the recovered logbook pages, information about 8 different bursts is available. The information includes the rods positions before and during a burst, the recorded subcritical reactor period and reactivity, and the burst fission yield derived from the temperature elevation sulfur pellet irradiation analysis. By using the HPRR logbook information and the as-built drawings of the critical assembly, a highly detailed model of the HPRR was created with SCALE 6.2.4/KENO-VI. Eight KENO-VI models were created to replicate the sub-critical assembly configurations described in the eight bursts from the recovered logbook pages. KENO-VI calculates k eff and it can be linked to a reactivity value in cents by using the delayed neutron fraction B eff , also calculated by KENO-VI. KENO-VI can also be used to model the prompt super-critical configurations of the HPRR and to assess the similarity with the burst measurements by comparing the calculated k eff and the measured fission yields between each burst. Unfortunately, high uncertainty exist and the obtained discrepancies between experiments and calculation results are high, compromising the creation of a valuable critical benchmark from HPRR operation data. The reasons of the discrepancies and potential ways to solve them are explored.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Capacity Markets for Transactive Energy Systems

Capacity markets provide important incentives for resource adequacy in electricity markets and may become more important for providing sufficient revenue and generation capacity with changes to energy market prices driven by increasing levels of zero marginal cost resources. However, current capacity market designs also have important shortfalls that may limit the benefits they can provide to the future grid. Current capacity markets are primarily designed for participation from conventional thermal generators, but markets are evolving with increasing levels of variable renewable energy resources. However, further reforms may be necessary to enable more participation from DERs and demand-side resources. To understand the benefits and shortfalls of current capacity market design, we review the historical reasons electricity markets have needed capacity markets or capacity payments for resource adequacy, and how current capacity market designs may create challenges for incorporating increasing levels of DERs and demand-side resources. We then consider how transactive systems, which allow the coordination of bids and offers for DERs and demand-side resources through a market interaction approach, administered by a Distribution System Operator (DSO), can address traditional resource adequacy problems due to inelastic consumer demand. We also consider the need for a DSO-level capacity market in helping to meet resource adequacy, reliability, and other electricity market objectives. We find that because the missing money in electricity markets is largely driven by incentives to meet resource adequacy goals, and the bulk grid would always supply power to the DSO, that resource adequacy is unlikely to be a determining factor in the need for a DSO-level capacity market. Many current reliability problems could also be addressed by the incorporation of more flexible demand enabled with transactive energy systems. However, other DSO objectives, including resilience, reactive power, voltage control, environmental policies, and energy equity could lead to specific challenges that could be aided by a DSO-level capacity market. We consider the possibility of a DSO-level capacity market in addressing these challenges as well as its potential role in coordinating with the Independent System Operator (ISO) who operates the wholesale market. We conclude with suggestions for future research, including the need to develop analytical models of DSO-level capacity market designs to address these potential objectives and examine their implications for DSOs and consumers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

State Estimation-Based Distributed Energy Resource Optimization for Distribution Voltage Regulation in Telemetry-Sparse Environments Using a Real-Time Digital Twin

Real-time state estimation using a digital twin can overcome the lack of in-field measurements inside an electric feeder to optimize grid services provided by distributed energy resources (DERs). Optimal reactive power control of DERs can be used to mitigate distribution system voltage violations caused by increased penetrations of photovoltaic (PV) systems. In this work, a new technology called the Programmable Distribution Resource Open Management Optimization System (ProDROMOS) issued optimized DER reactive power setpoints based-on results from a particle swarm optimization (PSO) algorithm wrapped around OpenDSS time-series feeder simulations. This paper demonstrates the use of the ProDROMOS in a RT simulated environment using a power hardware-in-the-loop PV inverter and in a field demonstration, using a 678 kW PV system in Grafton (MA, USA). The primary contribution of the work is demonstrating a RT digital twin effectively provides state estimation pseudo-measurements that can be used to optimize DER operations for distribution voltage regulation.

Darbali-Zamora, Rachid↗

Particle-based high-temperature thermochemical energy storage reactors

Solar and other renewable energy driven gas-solid thermochemical energy storage (TCES) technology is a promising solution for the next generation energy storage systems due to its high operating temperature, efficient energy conversion, ultra-long storage duration, and potential high energy density. Experimental and theoretical studies suggest that the respective gravimetric and volumetric TCES energy storage densities vary from 200 to 3000 kJ kg –1 and 1–3 GJ m –3 . Solar radiation or heat generated from electric furnaces powered by renewable electricity can be stored in the form of chemical energy through endothermic reactions, while the stored chemical energy can be converted to thermal energy via an exothermic reaction when needed. The design of highly effective reactors requires a deep understanding of materials, thermodynamics, chemical kinetics, and transport phenomena. At time of writing, TCES reactors are yet to be deployed at commercially relevant scales, leaving a substantial gap between development efforts and commercial feasibility. Therefore, this review aims to examine the state-of-the-art design and performance of particle-based TCES reactors with different reactive materials. Fundamentals related to TCES reactive materials, reaction conditions, thermodynamics and kinetics, and transport phenomena are reviewed in detail to provide a comprehensive understanding of the reactor design and operation. Five major types of TCES reactors have been comprehensively reviewed and compared, including fixed, moving, rotary, fluidized, and entrained bed reactors. Most reported prototype reactors in the literature operate at lab scale with thermal inputs below 40 kW, and scaled TCES reactors (e.g., at megawatt level) are yet to be demonstrated. The nominal reactor operating temperatures range from 300 to 1500 °C, depending on the selected chemistry, reactive material, and heat sources. To evaluate their designs, the reactors are assessed in aspects of performance, cost, and durability. Discrepancies in performance indicators of energy storage density, extent of reaction, and various energy efficiencies are highlighted. The scale-up of reactors and power block integration, which hold the key to the successful commercialization of TCES systems, are critically analyzed. Furthermore, advanced materials (both reactive materials and ceramic reactor housing materials), effective particle flow control, advanced modeling tools, and novel system design may bring significant improvement to the energy efficiency, storage density and cost competitiveness of particle-based TCES reactors.

25 ENERGY STORAGE↗

Dynamic Behavior of Platinum Atoms and Clusters in the Native Oxide Layer of Aluminum Nanocrystals

Strong metal–support interactions (SMSIs) are well-known in the field of heterogeneous catalysis to induce the encapsulation of platinum (Pt) group metals by oxide supports through high temperature H 2 reduction. However, demonstrations of SMSI overlayers have largely been limited to reducible oxides, such as TiO 2 and Nb 2 O 5 . In this report we show that the amorphous native surface oxide of plasmonic aluminum nanocrystals (AlNCs) exhibits SMSI-induced encapsulation of Pt following reduction in H 2 in a Pt structure dependent manner. Reductive treatment in H 2 at 300 °C induces the formation of an AlO x SMSI overlayer on Pt clusters, leaving Pt single-atom sites (Ptiso) exposed available for catalysis. The remaining exposed Pt iso species possess a more uniform local coordination environment than has been observed on other forms of Al 2 O 3 , suggesting that the AlO x native oxide of AlNCs presents well-defined anchoring sites for individual Pt atoms. This observation extends our understanding of SMSIs by providing evidence that H 2 -induced encapsulation can occur for a wider variety of materials and should stimulate expanded studies of this effect to include nonreducible oxides with oxygen defects and the presence of disorder. It also suggests that the single-atom sites created in this manner, when combined with the plasmonic properties of the Al nanocrystal core, may allow for site-specific single-atom plasmonic photocatalysis, providing dynamic control over the light-driven reactivity in these systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ARCS Replacement at TREAT for TRTR 2020 - Abstract

The Transient REActor Test (TREAT) facility was restarted in 2017 to perform reactor fuels testing under transient conditions, following shutdown in 1994 and 23 years in non-operational standby. TREAT is a transient reactor that, like most pulsing reactors, can create natural shaped power pulses. However, TREAT provides the ability to shape the power pulse and control the energy deposition rate on the test specimens by automatically controlling the amount of reactivity insertion over time. The original automatic reactor control system (ARCS) was created in the 1980s using INTEL 8086 CPU boards and software written in assembly code. The need to maintain the system for the next 40+ years of TREAT life led to the decision to replace ARCS with modern hardware while maintaining the original functionality. After a prototyping effort, the replacement was successfully completed in the first quarter of 2020. The process and results of that effort are reported here.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reactive Power Control Methods for Islanded Operation

As feeder-level microgrid controls begin to incorporate multiple GFM DER and voltage regulation equipment, island reactive power dispatch strategies can be improved. Although Volt-Var Optimization (VVO) control is typical in an Advanced Distribution Management System (ADMS), most microgrid controllers do not apply VVO during island operations. This report investigates reactive power control strategies for feeder-level microgrid operations. It also proposes evaluation metrics that can be applied to analyze the performance improvements of the new microgrid control strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Intricate Genetic Programs Controlling Dormancy in Mycobacterium tuberculosis

Mycobacterium tuberculosis (MTB) displays the remarkable ability to transition in and out of dormancy, a hallmark of the pathogen’s capacity to evade the immune system and exploit susceptible individuals. Uncovering the gene regulatory programs that underlie the phenotypic shifts in MTB during disease latency and reactivation has posed a challenge. We develop an experimental system to precisely control dissolved oxygen levels in MTB cultures in order to capture the transcriptional events that unfold as MTB transitions into and out of hypoxia-induced dormancy. Using a comprehensive genome-wide transcription factor binding map and insights from network topology analysis, we identify regulatory circuits that deterministically drive sequential transitions across six transcriptionally and functionally distinct states encompassing more than three-fifths of the MTB genome. The architecture of the genetic programs explains the transcriptional dynamics underlying synchronous entry of cells into a dormant state that is primed to infect the host upon encountering favorable conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Model Predictive Voltage Control of Large-Scale PV or Hybrid PV-BESS Plants

Increased penetration level of inverter-based resources (IBRs) and renewable energy in the power grid has called for more requirements from the control of IBRs. In this paper, the voltage-reactive power control of a photovoltaic (PV) power plant or hybrid PV-battery energy storage system (BESS) plant connected to a bulk power grid, whilst meeting the grid requirements, is studied. In this paper, a continuous-set model predictive control (MPC) formulation is proposed for voltage-reactive power control. For the same, an aggregated dynamic PV plant model is developed based on the recursive system equivalencing method. The formulation is then implemented in PSCAD simulation on a 125 MW PV plant or hybrid PV-BESS plant. The MPC implementation achieves 10.13% voltage improvement based on PSCAD simulation results in a balanced fault case study. Simulation results further demonstrate that MPC provides improved voltage support over the conventional proportional-integral (PI) controller post-fault occurrence.

Abu rub, Omar↗

Advanced Hierarchical Control Strategies in Multi-Building Microgrids

This paper proposes a hierarchical control system for a multi-building AC microgrid with improved inertia and immunity to communication delay. The primary level control is based on a Virtual Synchronous Generator (VSG) control and the secondary level control is enhanced with a SmithPredictor to improve the stability of the system in the presence of communication delay. Moreover, tertiary level control is proposed to effectively control active and reactive power sharing between the grid and the microgrid. Islanded and grid-connected modes of the microgrid system under study are illustrated with the help of simulation results in MATLAB Simulink environment.

Weldehawaryat, Lidya Mussie [graduate research ass↗

Rheology guiding the design and printability of aqueous colloidal composites for additive manufacturing

Vat photopolymerization (VP) and direct ink write (DIW) additive manufacturing (AM) provide complex geometries with precise spatial control employing a vast array of photo-reactive polymeric systems. Although VP is recognized for superior resolution and surface finish, DIW provides versatility for higher viscosity systems. However, each AM platform presents specific rheological requirements that are essential for successful 3D printing. First, viscosity requirements constrain VP polymeric materials to viscosities below 10 Pa s. Thus, this requirement presents a challenging paradox that must be overcome to attain the physical performance of high molecular weight polymers while maintaining suitable viscosities for VP polymeric materials. Second, the necessary rheological complexity that is required for DIW pastes requires additional rheological measurements to ensure desirable thixotropic behavior. Further, this manuscript describes the importance of rheological measurements when designing polymeric latexes for AM. Latexes effectively decouple the dependency of viscosity on molecular weight, thus enabling high molecular weight polymers with low viscosities. Photo-crosslinking of water-soluble monomers and telechelic oligomeric diacrylates in the presence of the latex enables the fabrication of a scaffold, which is restricted to the continuous aqueous phase and effectively surrounds the latex nanoparticles enabling the printing of otherwise inaccessible high molecular weight polymers. Rheological testing, including both steady and oscillatory shear experiments, provides insights into system properties and provides predictability for successful printing. This perspective article aims to provide an understanding of both chemical functionality (photo- and thermal-reactivity) and rheological response and their importance for the successful design and evaluation of VP and DIW processable latex formulations.

36 MATERIALS SCIENCE↗

Summary of GFL Inverter Capability and Performance: Malawi [Slides]

This presentation provides a comprehensive comparison of inverter-based resource (IBR) technical requirements across multiple international grid codes - including IEEE 2800, ESO, EirGrid, and Malawi's evolving regulatory framework - to support capacity building for electricity-sector institutions in Malawi. It highlights key performance expectations for grid-following (GFL) inverters across critical domains such as primary and fast frequency response, ramping behavior, frequency and voltage ride-through capabilities, reactive power and voltage control, ROCOF withstand, phase jump tolerance, system strength considerations, protection schemes, and dynamic modeling requirements. Emphasizing a "Do no harm, do something, do more" philosophy, the document synthesizes best practices and operational benchmarks to guide the integration and stability of inverter-based resources within Malawi's power system. The presentation forms part of the SABESS Center of Excellence initiative supported by the Global Energy Alliance for People and the Planet.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Comparison of DER Voltage Regulation Technologies Using Real-Time Simulations

Grid operators are now considering using distributed energy resources (DERs) to provide distribution voltage regulation rather than installing costly voltage regulation hardware. DER devices include multiple adjustable reactive power control functions, so grid operators have the difficult decision of selecting the best operating mode and settings for the DER. In this work, we develop a novel state estimation-based particle swarm optimization (PSO) for distribution voltage regulation using DER-reactive power setpoints and establish a methodology to validate and compare it against alternative DER control technologies (volt–VAR (VV), extremum seeking control (ESC)) in increasingly higher fidelity environments. Distribution system real-time simulations with virtualized and power hardware-in-the-loop (PHIL)-interfaced DER equipment were run to evaluate the implementations and select the best voltage regulation technique. Each method improved the distribution system voltage profile; VV did not reach the global optimum but the PSO and ESC methods optimized the reactive power contributions of multiple DER devices to approach the optimal solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Predictive sufficiency and the use of stored internal state

In all embedded computing systems, some delay exists between sensing and acting. By choosing an action based on sensed data, a system is essentially predicting that there will be no significant changes in the world during this delay. However, the dynamic and uncertain nature of the real world can make these predictions incorrect, and thus, a system may execute inappropriate actions. Making systems more reactive by decreasing the gap between sensing and action leaves less time for predictions to err, but still provides no principled assurance that they will be correct. Using the concept of predictive sufficiency described in this paper, a system can prove that its predictions are valid, and that it will never execute inappropriate actions. In the context of our CIRCA system, we also show how predictive sufficiency allows a system to guarantee worst-case response times to changes in its environment. Using predictive sufficiency, CIRCA is able to build real-time reactive control plans which provide a sound basis for performance guarantees that are unavailable with other reactive systems.

Musliner, David J.↗