Search NASA⌕ Search

SEARCH · Search NASA

Results for “Real time analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Physics-informed machine learning with differentiable programming for heterogeneous underground reservoir pressure management

Abstract Avoiding over-pressurization in subsurface reservoirs is critical for applications like CO $$_2$$ 2 sequestration and wastewater injection. Managing the pressures by controlling injection/extraction are challenging because of complex heterogeneity in the subsurface. The heterogeneity typically requires high-fidelity physics-based models to make predictions on CO $$_2$$ 2 fate. Furthermore, characterizing the heterogeneity accurately is fraught with parametric uncertainty. Accounting for both, heterogeneity and uncertainty, makes this a computationally-intensive problem challenging for current reservoir simulators. To tackle this, we use differentiable programming with a full-physics model and machine learning to determine the fluid extraction rates that prevent over-pressurization at critical reservoir locations. We use DPFEHM framework, which has trustworthy physics based on the standard two-point flux finite volume discretization and is also automatically differentiable like machine learning models. Our physics-informed machine learning framework uses convolutional neural networks to learn an appropriate extraction rate based on the permeability field. We also perform a hyperparameter search to improve the model’s accuracy. Training and testing scenarios are executed to evaluate the feasibility of using physics-informed machine learning to manage reservoir pressures. We constructed and tested a sufficiently accurate simulator that is 400 000 times faster than the underlying physics-based simulator, allowing for near real-time analysis and robust uncertainty quantification.

54 ENVIRONMENTAL SCIENCES↗

Time-resolved luminescence detection of peroxynitrite using a reactivity-based lanthanide probe

Peroxynitrite (ONOO - ) is a powerful and short-lived oxidant formed in vivo, which can react with most biomolecules directly. To fully understand the roles of ONOO - in cell biology, improved methods for the selective detection and real-time analysis of ONOO - are needed. We present a water-soluble, luminescent europium(III) probe for the rapid and sensitive detection of peroxynitrite in human serum, living cells and biological matrices. We have utilised the long luminescence lifetime of the probe to measure ONOO - in a time-resolved manner, effectively avoiding the influence of autofluorescence in biological samples. To demonstrate the utility of the Eu(III) probe, we monitored the production of ONOO - in different cell lines, following treatment with a cold atmospheric plasma device commonly used in the clinic for skin wound treatment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated instant labeling chemistry workflow for real-time monitoring of monoclonal antibody N -glycosylation

With the transition toward continuous bioprocessing, process analytical technology (PAT) is becoming necessary for rapid and reliable in-process monitoring during biotherapeutics manufacturing. Bioprocess 4.0 is looking to build end-to-end bioprocesses that include PAT-enabled real-time process control. This is especially important for drug product quality attributes that can change during bioprocessing, such as protein N-glycosylation, a critical quality attribute for most monoclonal antibody (mAb) therapeutics. Glycosylation of mAbs is known to influence their efficacy as therapeutics and is regulated for a majority of mAb products on the market today. Currently, there is no method to truly measure N-glycosylation using on-line PAT, hence making it impractical to design upstream process control strategies. We recently described the N-GLYcanyzer workflow: an integrated PAT unit that measures mAb N-glycosylation within 3 hours of automated sampling from a bioreactor. Here, we integrated Agilent's Instant Procainamide (InstantPC) based chemistry workflow into the N-GLYcanyzer PAT unit to allow for nearly 10× faster near real-time analysis of mAb glycoforms. Furthermore, our methodology is explained in detail to allow for replication of the PAT workflow as well as present a case study demonstrating the use of this PAT to autonomously monitor a mammalian cell perfusion process at the bench scale to gain increased knowledge of mAb glycosylation dynamics during continuous biologics manufacturing using Chinese hamster ovary (CHO) cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Holistic Numerical Calibration of the iMESA Electrostatic Analyzer

A drifted Maxwellian velocity distribution is the most common model used to interpret the data from low-energy charged-particle instruments onboard spacecraft that are used to investigate the ambient plasma environment in the low Earth orbit (LEO). An original method is presented for determining the flow parameters (density, temperature, and flow energy) of such a distribution from the output of the integrated miniaturized electrostatic analyzer, which has been successfully flown on several LEO missions. Rather than attempting to deconvolve from the on-orbit data the analyzer’s response to an ideal, monoenergetic input, numerical simulation is used to predict and parameterize the response of the device to an input distribution that includes an isotropic, non-zero temperature, yielding a straightforward method for extracting the flow parameters from the spacecraft data. The method is computationally simple enough to be incorporated into a robust algorithm suitable for rapid batch processing or real-time analysis of data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance demonstration of vacuum microwave components critical for the operation of the ITER low-field side reflectometer

Final design studies in preparation for manufacturing have been performed for functional components of the vacuum portion of the ITER Low-Field Side Reflectometer (LFSR). These components consist of an antenna array, electron cyclotron heating (ECH) protection mirrors, phase calibration mirrors, and vacuum windows. Evaluation of these components was conducted at the LFSR test facility and DIII-D. The antenna array consists of six corrugated-waveguide antennas for simultaneous profile, fluctuation, and Doppler measurements. A diffraction grating, incorporated into the plasma-facing miter bend, provides protection of sensitive components from stray ECH at 170 GHz. For in situ phase calibration of the LFSR profile reflectometer, an embossed mirror is incorporated into the adjacent miter bend. Measurements of the radiated beam profile indicate that these components have a small, acceptable effect on mode conversion and beam quality. Baseline transmission characteristics of the dual-disk vacuum window are obtained and are used to guide ongoing developments. Preliminary simulations indicate that a surface-relief structure on the window surfaces can greatly improve transmission. The workability of real-time phase measurements was demonstrated on the DIII-D profile reflectometer. The new automated real-time analysis agrees well with the standard post-processing routine.

47 OTHER INSTRUMENTATION↗

Initial operation and data processing on a system for real-time evaluation of Thomson scattering signals on the Large Helical Device

A scalable system for real-time analysis of electron temperature and density based on signals from the Thomson scattering diagnostic, initially developed for and installed on the NSTX-U experiment, was recently adapted for the Large Helical Device and operated for the first time during plasma discharges. During its initial operation run, it routinely recorded and processed signals for four spatial points at the laser repetition rate of 30 Hz, well within the system’s rated capability for 60 Hz. We present examples of data collected from this initial run and describe subsequent adaptations to the analysis code to improve the fidelity of the temperature calculations.

47 OTHER INSTRUMENTATION↗

Few-femtosecond resolved imaging of laser-driven nanoplasma expansion

Abstract The free expansion of a planar plasma surface is a fundamental non-equilibrium process relevant for various fields but as-yet experimentally still difficult to capture. The significance of the associated spatiotemporal plasma motion ranges from astrophysics and controlled fusion to laser machining, surface high-harmonic generation, plasma mirrors, and laser-driven particle acceleration. Here, we show that x-ray coherent diffractive imaging can surpass existing approaches and enables the quantitative real-time analysis of the sudden free expansion of laser-heated nanoplasmas. For laser-ionized SiO 2 nanospheres, we resolve the formation of the emerging nearly self-similar plasma profile evolution and expose the so far inaccessible shell-wise expansion dynamics including the associated startup delay and rarefaction front velocity. Our results establish time-resolved diffractive imaging as an accurate quantitative diagnostic platform for tracing and characterizing plasma expansion and indicate the possibility to resolve various laser-driven processes including shock formation and wave-breaking phenomena with unprecedented resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutral beam prompt loss in LTX-β

Prompt loss of beam injected fast ions approaches 100% in lithium tokamak experiment-beta (LTX-β) discharges, though significantly improved confinement is expected for the higher current plasmas made available by a recent upgrade to the Ohmic heating power supply. Modeling of fast ions using TRANSP/NUBEAM finds a maximum coupled beam fraction of 76% at the near-term limits of the LTX-β operating space. The full ion orbit code POET is employed to validate NUBEAM results against possible non-adiabatic effects on fast ion orbits, but corrections to the prompt loss fraction due to collisionless transport are found to be small. The graphical method code CONBEAM is used to investigate the topology of fast ion phase space as it relates to neutral beam deposition, and counter-injected NBI is considered as a way to access a region of high field side beam deposition. A metric is developed within the CONBEAM using a beam filament model to estimate the prompt loss fraction and shown to agree well with both POET and NUBEAM, enabling near real-time analysis and potential feedback to operators between plasma discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Task Based Approach for Co-Scheduling Ensemble Workloads on Heterogeneous Nodes

Scientific workflows consist of multiple, connected applications, with data and results flowing from one to another in a pipeline. Traditionally, such workflows are executed in sequential order, storing intermediate data in storage disks. Co-scheduling application workflows concurrently on the same compute nodes would greatly reduce the cost of moving data to/from storage and allow real-time analysis of intermediate results. Nevertheless, most parallel programming runtimes do not allow seamless integration of various applications in a scientific workflow, in part due to the complexity of managing data and resources. The situation is even more complicated for heterogeneous systems. In this work we extend the Minos Computing Library (MCL) runtime to accelerate pipe-lined and parallel workloads where multiple applications are running in the same system. MCL’s asynchronous task library and runtime dynamically manages resources to allow co-scheduling of multiple processes sharing heterogeneous resources. In addition, we design a custom ex- tension of the Open Compute Language (OpenCL) to enable multiple processes to share device memory. We enable MCL to coordinate these shared buffers to allow for easy, fast data sharing between applications. Using malleable micro-benchmarks and two application workflows that combine scientific simulation and AI-based analysis, we show that our method outperforms traditional approaches.

Index Terms—Parallel systems, Scheduling and Task ↗

Reagent-free Hyperspectral Diagnosis of SARS-CoV-2 Infection in Saliva Samples

Rapid, reagent-free pathogen-agnostic diagnostics that can be performed at the point of need are vital for preparedness against future outbreaks. Yet, many current strategies are pathogen-specific and require several reagents. We present hyperspectral sensing, using light to non-invasively measure the composition of several molecules to form a spectral signature, to overcome these barriers. To generate these spectral signatures, we present the ProSpectral TM V1, a novel, miniaturized hyperspectral platform with high spectral resolution with two mini-spectrometers. Furthermore, we developed state-of-the-art ML pipelines for near real-time analysis of spectral signatures in saliva samples. We found that we could accurately identify SARS-CoV-2 infection status in double-blinded saliva samples and demonstrate 100% accuracy on a hold out test dataset. To our knowledge, this establishes the fastest hyperspectral diagnostic platform and in a small form factor, and executable with liquid samples, without ligands or reagents, all while maintaining PCR level specificity and sensitivity.

59 BASIC BIOLOGICAL SCIENCES↗

Detector Interface for Streaming, Control, and Open-source integration (DISCO) v1.0.0

This suite consists of a multi-package ecosystem featuring detector emulators, EPICS areaDetector drivers, and remote server frameworks designed for the Advanced Light Source (ALS). Engineered for high-bandwidth devices—including VFCCD, Timepix3, Timepix4, and related pixel detectors—the software simulates hardware, wraps vendor SDKs into remote-callable servers, and integrates with open-source control systems. Key Capabilities: Distributed SDK Architecture: Server packages wrap hardware-specific SDKs, allowing areaDetector drivers to execute remote framework calls. This isolates proprietary libraries from the EPICS IOC, enhancing stability and enabling distributed computing across beamline networks. Device Support: Custom drivers for VFCCD, the Timepix family, and similar sensors optimize the data path from hardware control to high-speed transport. Full-Stack Emulation: Sophisticated emulator packages allow end-to-end pipeline testing and software development without requiring physical hardware or beam time. Integrated Workflows: Supports high-bandwidth streaming for real-time analysis and robust, metadata-rich file-based workflows (e.g., HDF5/NeXus). By standardizing interfaces across heterogeneous hardware, this suite reduces technical debt. It provides the ALS with a scalable, open-source solution to manage massive data rates within a unified control environment.

Mahl, Johannes [Lawrence Berkeley National Laborat↗

Laser Ablation Plasmas and Spectroscopy for Nuclear Applications

The development of measurement methodologies to detect and monitor nuclear-relevant materials remains a consistent and significant interest across the nuclear energy, nonproliferation, safeguards, and forensics communities. Optical spectroscopy of laser-produced plasmas is becoming an increasingly popular diagnostic technique to measure radiological and nuclear materials in the field without sample preparation, where current capabilities encompass the standoff, isotopically resolved and phase-identifiable (e.g., UO and UO[Formula: see text]) detection of elements across the periodic table. These methods rely on the process of laser ablation (LA), where a high-powered pulsed laser is used to excite a sample (solid, liquid, or gas) into a luminous microplasma that rapidly undergoes de-excitation through the emission of electromagnetic radiation, which serves as a spectroscopic fingerprint for that sample. This review focuses on LA plasmas and spectroscopy for nuclear applications, covering topics from the wide-area environmental sampling and atmospheric sensing of radionuclides to recent implementations of multivariate machine learning methods that work to enable the real-time analysis of spectrochemical measurements with an emphasis on fundamental research and development activities over the past two decades. Background on the physical breakdown mechanisms and interactions of matter with nanosecond and ultrafast laser pulses that lead to the generation of laser-produced microplasmas is provided, followed by a description of the transient spatiotemporal plasma conditions that control the behavior of spectroscopic signatures recorded by analytical methods in atomic and molecular spectroscopy. High-temperature chemical and thermodynamic processes governing reactive LA plasmas are also examined alongside investigations into the condensation pathways of the plasma, which are believed to serve as chemical surrogates for fallout particles formed in nuclear fireballs. Laser-supported absorption waves and laser-induced shockwaves that accompany LA plasmas are also discussed, which could provide insights into atmospheric ionization phenomena from strong shocks following nuclear detonations. Furthermore, the standoff detection of trace radioactive aerosols and fission gases is reviewed in the context of monitoring atmospheric radiation plumes and off-gas streams of molten salt reactors. Finally, concluding remarks will present future outlooks on the role of LA plasma spectroscopy in the nuclear community.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observing and modeling the effects of production infrastructure in electromagnetic surveys

Electromagnetic (EM) methods are among the original techniques for subsurface characterization in exploration geophysics because of their particular sensitivity to the earth electrical conductivity, a physical property of rocks distinct yet complementary to density, magnetization, and strength. However, this unique ability also makes them sensitive to metallic artifacts — infrastructure such as pipes, cables, and other forms of cultural clutter — the EM footprint of which often far exceeds their diminutive stature when compared to that of bulk rock itself. In the hunt for buried treasure or unexploded ordnance, this is an advantage; in the long-term monitoring of mature oil fields after decades of production, it is quite troublesome indeed. In this study we consider the latter through the lens of an evolving energy industry landscape in which the traditional methods of EM characterization for the exploration geophysicist are applied toward emergent problems in well-casing integrity, carbon capture and storage, and overall situational awareness in the oil field. We introduce case studies from these exemplars, showing how signals from metallic artifacts can dominate those from the target itself and impose significant burdens on the requisite simulation complexity. Furthermore, we show how recent advances in numerical methods mitigate the computational explosivity of infrastructure modeling, providing feasible and real-time analysis tools for the desktop geophysicist. Lastly, we demonstrate through comparison of field data and simulation results that incorporation of infrastructure into the analysis of such geophysical data is, in a growing number of cases, a requisite but now manageable step.

58 GEOSCIENCES↗

Recovering the phase and amplitude of X-ray FEL pulses using neural networks and differentiable models

Dynamics experiments are an important use-case for X-ray free-electron lasers (XFELs), but time-domain measurements of the X-ray pulses themselves remain a challenge. Shot-by-shot X-ray diagnostics could enable a new class of simpler and potentially higher-resolution pump-probe experiments. Here, we report training neural networks to combine low-resolution measurements in both the time and frequency domains to recover X-ray pulses at high-resolution. Critically, we also recover the phase, opening the door to coherent-control experiments with XFELs. The model-based generative neural-network architecture can be trained directly on unlabeled experimental data and is fast enough for real-time analysis on the new generation of MHz XFELs.

42 ENGINEERING↗

Measuring Hydroxylammonium, Nitrate, and Nitrite Concentration with Raman Spectroscopy for 238 Pu Supply Program

Optical spectroscopy has great potential to improve the timeliness of important analytical measurements for the 238 Pu Supply Program by enabling real-time analysis of process solutions within radiochemical hot cells. Hydroxylammonium (H 3 NOH + ]), nitrate (NO 3 - ), and nitrite (NO 2 - ) are three important molecular species present in multiple aqueous streams throughout the program’s flow sheet. The concentration of each species normally goes uncharacterized during processing. However, rapid quantification may benefit the program because uncertainties in kinetic redox expressions describing hydroxylammonium (HA) and nitrite reactions with Np and Pu leads to uncertainty in process model predictions for solvent extraction runs. HA concentration is normally quantified using ion chromatography, a technique that requires diluted grab samples taken out of the hot cell and analyzed off-line. Here we evaluate Raman spectroscopy for determining the concentration of H 3 NOH + , NO 3 - , and NO 2 - in benchtop tests to determine limits of detection. We also consider the possibility of using Raman spectroscopy in both glove box and hot cell environments for rapid analysis and pinpoint additional development opportunities needed to make this application successful.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analog Computing for Science

Conventional digital computing faces fundamental physical limits: large scale computing systems already con sume tens of Megawatts of power, Dennard scaling has ended, and data movement costs dominate application performance. Next generation experimental facilities generate data at rates that overwhelm conventional pro cessing and demand real-time analysis at the source. Analog computing, which exploits the continuous dynamics of physical systems to perform computation, promises a transformative path toward orders-of-magnitude gains in energy efficiency and time-to-solution for scientific workloads.

97 MATHEMATICS AND COMPUTING↗

Rapid Sensing to Facilitate Purification of Rare Earth Element-Containing Process Streams Produced Through Membrane-Assisted Solvent Extraction

The development of an economically competitive domestic supply of rare earth elements and yttrium (REY) is necessary for our nation’s economic growth and national security. The achievement of a secure domestic supply of REY requires not only the development of effective processes for recovery of REY from naturally occurring materials and/or recycled products, but also the development of downstream processes for the ultimate production of high-REY content solids. An impediment to the development of such processes is the scarcity of analytical methods that provide rapid determination of the process stream compositions. In this work, a membrane-based extraction process was used to selectively recover REYs from a dilute solution in the presence of much higher concentrations of Ca and Al. In tandem, the use of a portable spectrometer equipped with an immobilized zinc adeninate benzene tricarboxylate metal-organic framework sensing material makes possible the rapid detection of the presence of ppm concentrations of Tb and Eu in both weakly acidic and strongly acidic process streams within minutes. A solvent extraction processing time of 15-60 min maximized REY selectivity over gangue ions while achieving up to 80% REY and minimal gangue ion recovery. Taken together, these experiments highlight not only an innovative method for REY purification but also the importance of inexpensive, portable characterization methods for near real-time analysis of REY content.

Membrane-assisted solvent extraction↗

Bayesian Attack Model (BAM) User Story

This document presents a user story for the Bayesian Attack Model (BAM) tool designed to aggregate and analyze cyber-attack observables for operational technology (OT) systems. BAM aims to empower cybersecurity analysts by providing a streamlined interface for collecting observable data from various sources, enabling real-time analysis of potential adversary activity. By enhancing the response capabilities of security teams, BAM facilitates risk-informed decision-making and improves organizational security posture. This user story outlines the key functionalities, user interactions, and requirements necessary to successfully integrate BAM with other security information and event management (SIEM) technology and cybersecurity operations centers (CSOCs).

97 MATHEMATICS AND COMPUTING↗