Search NASA⌕ Search

SEARCH · Search NASA

Results for “Realizability checking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Sensitivity of the Tropical Atmosphere Energy Balance to ENSO-Related SST Changes: How Well Can We Quantify Hydrologic and Radiative Responses?

The continuing debate over feedback mechanisms governing tropical sea surface temperatures (SSTs) and tropical climate in general has highlighted the diversity of potential checks and balances within the climate system. Competing feedbacks due to changes in surface evaporation, water vapor, and cloud long- and shortwave radiative properties each may serve critical roles in stabilizing or destabilizing the climate system. It is also intriguing that even those climate variations having origins internal to the climate system-- changes in ocean heat transport for example, apparently require complementary equilibrating effects by changes in atmospheric energy fluxes. Perhaps the best observational evidence of this is the relatively invariant nature of tropically averaged net radiation exiting the top-of-atmosphere (TOA) as measured by broadband satellite sensors over the past two decades. Thus, analyzing how these feedback mechanisms are operating within the context of current interannual variability may offer considerable insight for anticipating future climate change. In this paper we focus on how fresh water and radiative fluxes over the tropical oceans change during ENSO warm and cold events and how these changes affect the tropical energy balance. At present, ENSO remains the most prominent known mode of natural variability at interannual time scales. Although great advances have been made in understanding this phenomenon and realizing prediction skill over the past decade, our ability to document the coupled water and energy changes observationally and to represent them in climate models seems far from settled (Soden, 2000 J Climate). Our analysis makes use a number of data bases, principally those derived from space-based measurements, to explore systematic changes in rainfall, evaporation, and surface and top-of-atmosphere (TOA) radiative fluxes, A reexamination of the Langley 8-Year Surface Radiation Budget data set reveals errors in the surface longwave emission due to use of biased SSTs. Subsequent correction allows subsequent use of this data set along with ERBE TOA fluxes to infer net atmospheric radiative beating. Further analysis of recent rainfall algorithms provides new estimates for precipitation variability in line with interannual evaporation changes inferred from the da Silva, Young, Levitus COADS analysis. The overall results from our analysis suggest an increase (decrease) of the hydrologic cycle during ENSO warm (cold) events at the rate of about 5 Wm-2 per K of SST change. This rate is slightly less than that which would be expected for constant relative humidity over the tropical oceans. Corresponding radiative fluxes seem systematically smaller resulting in a enhanced (suppressed) export of energy from the tropical ocean regions during warm (cold) SST events. Discussion of likely errors due to sampling and measurement strategies are discussed along with their impacts on our conclusions.

Robertson, Franklin R.↗

Miniature Sapphire Acoustic Resonator - MSAR

A room temperature sapphire acoustics resonator incorporated into an oscillator represents a possible opportunity to improve on quartz ultrastable oscillator (USO) performance, which has been a staple for NASA missions since the inception of spaceflight. Where quartz technology is very mature and shows a performance improvement of perhaps 1 dB/decade, these sapphire acoustic resonators when integrated with matured quartz electronics could achieve a frequency stability improvement of 10 dB or more. As quartz oscillators are an essential element of nearly all types of frequency standards and reference systems, the success of MSAR would advance the development of frequency standards and systems for both groundbased and flight-based projects. Current quartz oscillator technology is limited by quartz mechanical Q. With a possible improvement of more than x 10 Q with sapphire acoustic modes, the stability limit of current quartz oscillators may be improved tenfold, to 10(exp -14) at 1 second. The electromagnetic modes of sapphire that were previously developed at JPL require cryogenic temperatures to achieve the high Q levels needed to achieve this stability level. However sapphire fs acoustic modes, which have not been used before in a high-stability oscillator, indicate the required Q values (as high as Q = 10(exp 8)) may be achieved at room temperature in the kHz range. Even though sapphire is not piezoelectric, such a high Q should allow electrostatic excitation of the acoustic modes with a combination of DC and AC voltages across a small sapphire disk (approximately equal to l mm thick). The first evaluations under this task will test predictions of an estimated input impedance of 10 kilohms at Q = 10(exp 8), and explore the Q values that can be realized in a smaller resonator, which has not been previously tested for acoustic modes. This initial Q measurement and excitation demonstration can be viewed similar to a transducer converting electrical energy to mechanical energy and back. Such an electrostatic tweeter type excitation of a mechanical resonator will be tested at 5 MHz. Finite element calculation will be applied to resonator design for the desired resonator frequency and optimum configuration. The experiment consists of the sapphire resonator sandwiched between parallel electrodes. A DC+AC voltage can be applied to generate a force to act on a sapphire resonator. With the frequency of the AC voltage tuned to the sapphire resonator frequency, a resonant condition occurs and the sapphire Q can be measured with a high-frequency impedance analyzer. To achieve high Q values, many experimental factors such as vacuum seal, gas damping effects, charge buildup on the sapphire surface, heat dissipation, sapphire anchoring, and the sapphire mounting configuration will need attention. The effects of these parameters will be calculated and folded into the resonator design. It is envisioned that the initial test configuration would allow for movable electrodes to check gap spacing dependency and verify the input impedance prediction. Quartz oscillators are key components in nearly all ground- and space-based communication, tracking, and radio science applications. They play a key role as local oscillators for atomic frequency standards and serve as flywheel oscillators or to improve phase noise in high performance frequency and timing distribution systems. With ultra-stable performance from one to three seconds, an Earth-orbit or moon-based MSAR can enhance available performance options for spacecraft due to elimination of atmospheric path degradation.

Wang, Rabi T.↗

BuildingSync® v.2.5.0 2024 [SWR-18-28]

BuildingSync® is a building data exchange schema to better enable integration between software tools and building data workflows. The schema's original use case was focused on commercial building energy audits; however, several additional use cases have been realized including building energy modeling and more high-level generic building data exchange. BuildingSync helps streamline the data exchange process, improving the value of the data, minimizing duplication of effort for subsequent building data collection efforts (including audits), and facilitating the achievement of greater energy efficiency. This in done in part by standardizing on (a) reporting audits in an electronic format, (b) tracking proposed, implemented, and discarded energy conservation measures, and (c) storing building characteristics (at multiple levels) for audits, benchmarking, and building energy analysis. BuildingSync has several documents and tools available to help users understand how to best leverage BuildingSync. The list below are only a subset of the resources available. If new resources are discovered, then feel free to create a new pull request with the additions. Generic BuildingSync information is available on the DOE website and the project website. BuildingSync Examples - These examples are kept up to date and show a wide range of implementations. Any new update to BuildingSync is required to pass validation on these example files. BuildingSync Use Case Validator allows for users to determine if their instance complies with a specific use case for BuildingSync by checking if the required elements are implemented in an uploaded instance. An API is also provided for automated integration into other tools. Also, the website contains an easy way to view the entirety of the schema and how elements relate to the Building Exchange Data Exchange Specification. The Validator is open sourced here Use Case TestSuite provides a Python package for easier generation of BuildingSync use cases. BuildingSync use cases depend on the generation of schematron documents, which is time-consuming and difficult to implement well. The TestSuite allows users to define a use case using a more palatable CSV template, which it then turns into a Schematron document. The source code is available here. BuildingSync to OpenStudio/EnergyPlus. The translator is open sourced here. This project will translate a Level 1 (and partial Level 2) ASHRAE Energy Audit to a fully defined OpenStudio and EnergyPlus model. This project is in early Beta testing and any feedback is welcome!

Long, Nicholas↗

Diagnostic Techniques Used to Study Chemical-Vapor-Deposited Diamond Films

The advantages and utility of chemical-vapor-deposited (CVD) diamond as an industrial ceramic can only be realized if the price and quality are right. Until recently, this technology was of interest only to the academic and basic research community. However, interest has grown because of advances made by leading CVD diamond suppliers: 1) Reduction of the cost of CVD polycrystalline diamond deposition below $5/carat ($8/sq cm); 2) Installation of production capacity; 3) Epitaxial growth of CVD single-crystal diamond. Thus, CVD diamond applications and business are an industrial reality. At present, CVD diamond is produced in the form of coatings or wafers. CVD diamond film technology offers a broader technological potential than do natural and high-pressure synthetic diamonds because size, geometry, and eventually cost will not be as limiting. Now that they are cost effective, diamond coatings - with their extreme properties - can be used in a variety of applications. Diamond coatings can improve many of the surface properties of engineering substrate materials, including erosion, corrosion, and wear resistance. Examples of actual and potential applications, from microelectromechanical systems to the wear parts of diamond coatings and related superhard coatings are described. For example, diamond coatings can be used as a chemical and mechanical barrier for the space shuttles check valves, particularly on the guide pins and seat assemblies.

Miyoshi, Kazuhisa↗

Towards A Theory of Autonomous Reconstitution of Compromised Cyber-Systems

The ability to maintain mission-critical operations in cyber-systems in the face of disruptions is critical. Faults in cyber systems can come from accidental sources (e.g., natural failure of a component) or deliberate sources (e.g., an intelligent adversary). Natural and intentional manipulation of data, computing, or coordination are the most impactful ways that an attacker can prevent an infrastructure from realizing its mission goals. Under these conditions, the ability to reconstitute critical infrastructure becomes important. Specifically, the question is: Given an intelligent adversary, how can cyber systems respond to keep critical infrastructure operational? In cyber systems, the distributed nature of the system poses serious difficulties in maintaining operations, in part due to the fact that a centralized command and control apparatus is unlikely to provide a robust framework for resilience. Resilience in cyber-systems, in general, has several components, and requires the ability to anticipate and withstand attacks or faults, as well as recover from faults and evolve the system to improve future resilience. The recovery effort (and any subsequent evolution) may require significant reconfiguration of the system (at all levels – hardware, software, services, permissions, etc.) if the system is to be made resilient to further attack or faults. This is especially important in the case of ongoing attacks, where reconfiguration decisions must be taken with care to avoid further compromising the system while maintaining continuity of operations. Collectively, we will label this recovery and evolution process as “reconstitution”. Currently, reconstitution is performed manually, generally after-the-fact, and usually consists of either standing up redundant systems, check-points (rolling back the configuration to a “clean” state), or re-creating the system using “gold-standard” copies. For enterprise systems, such reconstitution may be performed either directly on hardware, or using virtual machines. A significant challenge within this context is the ability to verify that the reconstitution is performed in a manner that renders the cyber-system resilient to ongoing and future attacks or faults. Fundamentally, the need is to determine optimal configuration of the cyber system when a fault is determined to be present. While existing theories for fault tolerance (for example, Byzantine fault tolerance) can guarantee resilience under certain conditions, in practice, these theories can break down in the face of an intelligent adversary. Further, it is difficult, in a dynamically evolving environment, to determine whether the necessary conditions for resilience have been met, resulting in difficulties in achieving resilient operation. In addition, existing theories do not sufficiently take into account the cost for attack and defense (the adversary is generally assumed to have infinite resources and time), hierarchy of importance (all network resources are assumed to be equally important), and the dynamic nature of some attacks (i.e., as the attack evolves, can resilience be maintained?). Alternative approaches to resilience based on a centralized command and control structure suffer from a single-point-failure. This paper presents preliminary research towards concepts for effective autonomous reconstitution of compromised cyber systems. We describe a mathematical framework as a first step towards a theoretical basis for autonomous reconstitution in dynamic cyber-system environments. We then propose formulating autonomous reconstitution as an optimization problem and describe some of the challenges associated with this formulation. This is followed by a brief discussion on potential solutions to these challenges.

asymmetric resilience↗

TDCOSMO. IX. Systematic comparison between lens modelling software programs: time delay prediction for WGD 2038-4008

The importance of alternative methods for measuring the Hubble constant, such as time-delay cosmography, is highlighted by the recent Hubble tension. It is paramount to thoroughly investigate and rule out systematic biases in all measurement methods before we can accept new physics as the source of this tension. In this study, we perform a check for systematic biases in the lens modelling procedure of time-delay cosmography by comparing independent and blind time-delay predictions of the system WGD 2038-4008 from two teams using two different software programs: GLEE and LENSTRONOMY. The predicted time delays from the two teams incorporate the stellar kinematics of the deflector and the external convergence from line-of-sight structures. The un-blinded time-delay predictions from the two teams agree within 1.2σ, implying that once the time delay is measured the inferred Hubble constant will also be mutually consistent. However, there is a ~4σ discrepancy between the power-law model slope and external shear, which is a significant discrepancy at the level of lens models before the stellar kinematics and the external convergence are incorporated. We identify the difference in the reconstructed point spread function (PSF) to be the source of this discrepancy. When the same reconstructed PSF was used by both teams, we achieved excellent agreement, within ~0.6σ<, indicating that potential systematics stemming from source reconstruction algorithms and investigator choices are well under control. We recommend that future studies supersample the PSF as needed and marginalize over multiple algorithms or realizations for the PSF reconstruction to mitigate the systematics associated with the PSF. A future study will measure the time delays of the system WGD 2038-4008 and infer the Hubble constant based on our mass models.

79 ASTRONOMY AND ASTROPHYSICS↗

The ice age ecologist: testing methods for reserve prioritization during the last global warming: Reserve selection and the ice age ecologist

We play the role of an ice age ecologist (IAE) charged with conserving biodiversity during the climate changes accompanying the last deglaciation. We develop reserve-selection strategies for the IAE and check them against rankings based on modern data. Three reserve-selection strategies are developed. (1) Abiotic: the IAE uses no information about species–climate relationships, instead maximizing the climatic and geographic dispersion of reserves. (2) Species distribution models (SDMs): the IAE uses boosted-regression trees calibrated against pollen data and CCSM3 palaeoclimatic simulations from 21 to 15 ka bp to predict modern taxon distributions, then uses these as input to the Zonation reserve-ranking program. (3) Rank-and-regress: regression models are used to identify climatic predictors of zonation rankings. All strategies are assessed against a Zonation ranking based on modern pollen distributions. Analysis units are ecoregions and grid cells. The abiotic strategy has a negative or no correlation between predicted and actual rankings. The SDM-based strategy fares better, with a significantly positive area-corrected correlation (r= 0.474, P < 0.001) between predicted and actual rankings. Predictive ability drops when grid cells are the analysis unit (r= 0.217, P = 0.058). Predictive ability for the rank-and-regress strategy is similar to the SDM results. For the IAE, SDMs improve the predictive ability of reserve-selection strategies. However, predictive ability is limited overall, probably due to shifted realized niches during past no-analogue climates, new species interactions as species responded individually to climate change, and other environmental changes not included in the model. Twenty-first-century conservation planning also faces these challenges, and is further complicated by other anthropogenic impacts. The IAE's limited success does not preclude the use of climate scenarios and niche-based SDMs when developing adaptation strategies, but suggests that such tools offer at best only a rough guide to identifying possible areas of future conservation value.

54 ENVIRONMENTAL SCIENCES↗

PSIP For HDF5 Pilot Project (Final Report)

Productivity and Sustainability Improvement Planning (PSIP) is a lightweight, incremental and iterative approach (much in the same spirit as Agile methodologies) for making routine software process improvements in software projects. It is designed to be easily applied in existing development workflows. Quoting from a November 2019 workshop paper describing PSIP. PSIP breaks from classic software process improvement approaches such as CMM(I), SPICE, ISO 9000 or Six Sigma, in that it trades comprehensive standards and certification-driven assessment for self-defined, internally driven goals. It does, however, carry forward such ideas as having staged models of improvement (like CMM(I)) in the form of progress tracking cards. Additionally, PSIP is more aligned with lean and agile methods; it adopts their emphasis on iterative improvement and continuous learning. At its core, PSIP is an instantiation of the Plan-Do-Check-Act management cycle (PDCA, also known as Plan-Do-Study-Adjust) which provides the foundation for much of the modern software process improvement literature. This situates PSIP within a constellation of bottom-up, inductive software process improvement methods. PSIP is designed around the notion that already overburdened teams can define and carry out a series of small, incremental steps of progression towards improvement goals without significant (there will be some, but the goal is to avoid significant) disruption to ongoing development activities. A key enabling tool in PSIP is the use of Progress Tracking Cards (PTCs) which define the steps of progression towards a given improvement goal. This is the theory of PSIP. The PSIP for HDF5 project was aimed at putting PSIP into practice with the purpose of evaluating its effectiveness in planning and facilitating quality and process improvements in a scientific software project as well as its associated artifacts. The HDF5 project was chosen as a use case to evaluate PSIP for several reasons. First, NNSA labs and LLNL in particular have a keen interest in how HDF5 quality impacts its uptake and sustainability as a community adopted and supported code. Next, HDF5 is a foundational library, a key substrate in the HPC/CSE software stack, and any improvements there realized through this contract will have benefits to many DOE applications depending on it. HDF5 also represents an older, legacy code with technical debts to pay down. These characteristics are similar to many NNSA and even some ECP code projects. But, because HDF5 is an I/O library, it represents a simpler use case within which to study PSIP than a full-fledged and significantly more complex PDE simulation code. We believe these attributes make HDF5 an ideal use case for evaluating PSIP.

97 MATHEMATICS AND COMPUTING↗

BuildingSync® v.2.7.0 (released 9.11.2025) [SWR-18-28]

BuildingSync® is a building data exchange schema to better enable integration between software tools and building data workflows. The schema's original use case was focused on commercial building energy audits; however, several additional use cases have been realized including building energy modeling and more high-level generic building data exchange. Version 2.7.0 adds new elements for file attachment feature and FederalBuilding, and generalizes usage of Optional Elements (e.g. EquipmentCondition, EquipmentID) to all assets/systems. BuildingSync helps streamline the data exchange process, improving the value of the data, minimizing duplication of effort for subsequent building data collection efforts (including audits), and facilitating the achievement of greater energy efficiency. This in done in part by standardizing on (a) reporting audits in an electronic format, (b) tracking proposed, implemented, and discarded energy conservation measures, and (c) storing building characteristics (at multiple levels) for audits, benchmarking, and building energy analysis. BuildingSync has several documents and tools available to help users understand how to best leverage BuildingSync. The list below are only a subset of the resources available. If new resources are discovered, then feel free to create a new pull request with the additions. Generic BuildingSync information is available on the DOE website and the project website. BuildingSync Examples - These examples are kept up to date and show a wide range of implementations. Any new update to BuildingSync is required to pass validation on these example files. BuildingSync Use Case Validator allows for users to determine if their instance complies with a specific use case for BuildingSync by checking if the required elements are implemented in an uploaded instance. An API is also provided for automated integration into other tools. Also, the website contains an easy way to view the entirety of the schema and how elements relate to the Building Exchange Data Exchange Specification. The Validator is open sourced here Use Case TestSuite provides a Python package for easier generation of BuildingSync use cases. BuildingSync use cases depend on the generation of schematron documents, which is time-consuming and difficult to implement well. The TestSuite allows users to define a use case using a more palatable CSV template, which it then turns into a Schematron document. The source code is available here. BuildingSync to OpenStudio/EnergyPlus. The translator is open sourced here. This project will translate a Level 1 (and partial Level 2) ASHRAE Energy Audit to a fully defined OpenStudio and EnergyPlus model. This project is in early Beta testing and any feedback is welcome!

Long, Nicholas [National Renewable Energy Lab. (NR↗

Human Stability While Exercising on a VIS Device in Zero Gravity

BACKGROUND: A Vibration Isolation and Stabilization (VIS) system is being designed for use with the European Enhanced Exploration Exercise Device (E4D) [1]. The exercise bar is attached to cables that extend and retract through openings in the E4D platform, which the subject stands on while exercising. Since the E4D is mounted on a moving VIS device, the whole system moves under the subject’s feet. While tension in the cables does help stabilize a crew member in 0g by bracing him or her against the moving platform, flexible cables do not offer full support against falling. This raises the question of whether various exercises that are successfully performed in 1g on a stationary device can be performed without losing balance in 0g on a moving device. Quantifying stability conditions and establishing stability requirements for exercise countermeasure systems is a long-standing challenge and this work helped to inform this specific need for integrated E4D/VIS flight project development. METHODS AND RESULTS: A simplified stability analysis can be attempted based on platform accelerations generated by the VIS device simulation. In this type of analysis, the subject is conceived as standing on the platform in 0g while being held down to it by the tension in the cables. If the sideways acceleration of the platform is such that the cables cannot generate a sufficient moment relative to, e.g., the heels or the toes of the subject to overcome the tipping moment from the inertial forces on the accelerated subject’s body, the subject becomes unstable. This approach, which we refer to as the ‘static’ approximation, indicated failure of all the exercises that were considered in the comprehensive VIS analysis of the E4D. It was realized, however, that platform accelerations are not externally imposed but are themselves induced by the motion of the subject’s body during exercise, and a model calculation confirmed that this drastically altered the tipping moment on the subject, with the potential to even switch the direction in which the body would tip over. This made it imperative to consider in a coupled manner both the motion of the exercising subject’s body and the induced VIS platform motion while considering stability. The coupled dynamics requirement was met by the VIS simulation incorporating time-dependent human mass properties atop the platform and driven by the inertial forces from the prescribed subject motion relative to the platform based on motion-capture recorded human trajectories in 1g on a stationary E4D [2]. To analyze simulation results, a stability criterion was also needed. We do not know how to account for the human ‘control system’ that would take visual and vestibular cues as inputs as the platform moves in 0g. We thus chose to follow an approach we had previously used to analyze the dynamic feasibility of performing a task in lunar gravity along the human body trajectory recorded in 1g [3]. In this approach, one analyzes the center of pressure (COP) between the shoes and the ground (or platform) and checks if the COP remains within the convex hull of the footprints on the ground (or platform), commonly referred to as base of support (BOS). Since pressure is vertical and, in the absence of foot restraints, positive, the COP going outside the BOS indicates that the trajectory recorded in 1g is not dynamically feasible in microgravity and/or on the moving platform of the device. The outcome of the COP-based analysis was that some of the key exercises, especially the deadlift and the back squat exercises, were found to be dynamically feasible for at least some number of the exercise cycles, this number increasing with the cable tension. While this type of stability analysis does not account for the likely alteration of the exercise trajectory from its 1g form in space, it does show that there exist at least some realistic trajectories that pass the dynamic feasibility criterion. This adds confidence that, with further adjustment by the subject of the exercise form in 0g on a moving device, a number of exercises can be performed without losing balance.

D Frenkel↗

MODELING MID-INFRARED DIAGNOSTICS OF OBSCURED QUASARS AND STARBURSTS

We analyze the link between active galactic nuclei (AGNs) and mid-infrared flux using dust radiative transfer calculations of starbursts realized in hydrodynamical simulations. Focusing on the effects of galaxy dust, we evaluate diagnostics commonly used to disentangle AGN and star formation in ultraluminous infrared galaxies (ULIRGs). We examine these quantities as a function of time, viewing angle, dust model, AGN spectrum, and AGN strength in merger simulations representing two possible extremes of the ULIRG population: one is a typical gas-rich merger at z {approx} 0, and the other is characteristic of extremely obscured starbursts at z {approx} 2-4. This highly obscured burst begins star-formation-dominated with significant polycyclic aromatic hydrocarbon (PAH) emission, and ends with a {approx}10{sup 9} yr period of red near-IR colors. At coalescence, when the AGN is most luminous, dust obscures the near-infrared AGN signature, reduces the relative emission from PAHs, and enhances the 9.7 {mu}m absorption by silicate grains. Although generally consistent with previous interpretations, our results imply none of these indicators can unambiguously estimate the AGN luminosity fraction in all cases. Motivated by the simulations, we show that a combination of the extinction feature at 9.7 {mu}m, the PAH strength, and a near-infrared slope can simultaneously constrain the AGN fraction and dust grain distribution for a wide range of obscuration. We find that this indicator, accessible to the James Webb Space Telescope, may estimate the AGN power as tightly as the hard X-ray flux alone, thereby providing a valuable future cross-check and constraint for large samples of distant ULIRGs.

79 ASTRONOMY AND ASTROPHYSICS↗

Transactive Energy System Deployment Over Insecure Communication Links

Here, in this paper, the privacy and security issues associated with the transactive energy system (TES) deployment over insecure communication links are addressed. In particular, it is ensured that 1) individual agents’ bidding information is kept private throughout hierarchical market-based interactions; and 2) any extraneous data injection attack can be quickly and easily detected. An implementation framework is proposed to enable the cryptography-based enhancement of privacy and security for the deployment of any general hierarchical systems including TESs. Under the proposed framework, a unified cryptography-based approach is developed to achieve both privacy and security simultaneously. Specifically, privacy preservation is realized by an enhanced Paillier encryption scheme, where a block design is proposed to significantly improve computational efficiency. Attack detection is further achieved by an enhanced Paillier digital signature scheme, where a stamp-concatenation mechanism is proposed to enable detection of data replace and reorder attacks. Simulation results verify the effectiveness of the proposed cyber-resilient design for transactive energy systems. Note to Practitioners—This paper is motivated by addressing the issues of cyber resiliency for practically deploying transactive energy system (TES) but it is also applicable to the problem of enhancing the privacy and security for any general hierarchical control systems. TES is an emerging control approach that engages energy suppliers and customers through market operations and uses the price to optimally allocate energy resources. While it has been shown to be promising for power system applications, the underlying market-based interactions raise significant concerns of privacy (data leakage) and security (data tampering). However, existing TES works only focus on the coordination mechanism instead of privacy and security issues. This paper proposes a new cryptography-based TES design for practical deployment. Specifically, to protect privacy, individual supply and demand amounts to be exchanged are all encrypted in a particular way such that the original amounts cannot be inferred from the encrypted amounts, while the desired computation for setting the market clearing price can be carried out over the encrypted amounts, thus generating an encrypted result which, when decrypted, matches that of the same computation over the original amounts. To achieve security, for each exchanged data, its sender generates a particular digital signature which is exchanged together with the data. This enables the receiver to automatically detect the integrity by checking whether a mathematical relationship holds for the pair of data and signature. In our future research, we will investigate more challenging scenarios where some suppliers and customers themselves could be corrupted and purposely submit distorted amounts.

97 MATHEMATICS AND COMPUTING↗

NASA's Deep Space Network (DSN) Lunar Exploration Upgrades (DLEU)

In the near future, the National Aeronautics and Space Administration (NASA) will return to the moon beginning the next era of human exploration. NASA’s Space Communications and Navigation (SCaN) program will play a vital role in establishing communications and navigation support to realize the ambitious goals of the Artemis program. SCaN’s overall lunar communications support plan will be covered in a separate 2023 SpaceOps paper: “NASA’s Communications and Navigation Architecture Plans to Support the Return to the Moon and a Sustainable Lunar Presence”. The plan as it currently stands, includes a three-fold approach of lunar relay services, a dedicated set of new ground stations and support through the Deep Space Network (DSN). This paper will have a more granular focus on the DSN and NASA’s plans to upgrade and expand the network to be better suited for human spaceflight on and around the lunar surface. NASA’s Deep Space Network (DSN) will be a critical communications component for the upcoming lunar activities. There will be multiple spacecraft, using different bands, and some of those spacecraft will be transmitting and receiving using multiple bands, requiring DSN support of S-band (2 GHz), X-band (7 GHz up, 8 GHz down), and K-band (22.5 GHz up, 26 GHz down). Since there may be more than one spacecraft in the beamwidth of the DSN antennas, the DSN support will require an extension of the DSN’s capability to support multiple spacecraft using one antenna, expanding it to provide two simultaneous uplinks in the different bands at each antenna. Achieving this requires using new techniques for manufacturing the frequency selective surfaces, called dichroics, which steer the different frequency beams from and to the appropriate transmitting and receiving equipment, along with the addition of a new K-band uplink system. Additionally, due to the relative closeness of the moon from Earth (as opposed to the planetary missions the DSN supports daily), significantly higher data rates on both uplink and downlink are required, specifically up to 20 Mbps on the uplink and 150 Mbps on the downlink, both using Low Density Parity Check (LDPC) error correcting codes. And, again due to the relative closeness of the moon, there is a need for low latency data delivery of the high rate downlink telemetry which requires a change in the current DSN paradigm of delivering higher rate data with higher latency.

deep space network↗

NASA’s Deep Space Network (DSN) Lunar Exploration Upgrades (DLEU)

In the near future, the National Aeronautics and Space Administration (NASA) will returnhumansto the moon beginning the next era of human exploration. NASA’s Space Communications and Navigation (SCaN) program will play a vital role in establishing communications and navigation support to realize the ambitious goals of the Artemis program. SCaN’s overall lunar communications support plan will be covered in a separate 2023 SpaceOps paper: “NASA’s Communications and Navigation Architecture Plans to Support the Return to the Moon and a Sustainable Lunar Presence.” The four-point plan,as it currently stands, includes lunar relay services, a dedicated set of new ground stations, international partner contributions,and supportthrough the Deep Space Network (DSN)and associated upgrades. This paper will have a more granular focus on the DSN and NASA’s plans to upgrade and expand the network to be better suited for human spaceflight on and around the lunar surface. NASA’s Deep Space Network (DSN) will be a critical communications component for the upcoming lunar activities. There will be multiple spacecraft, using different bands, and some of those spacecraft will be transmitting and receiving using multiple bands, requiring DSN support of S-band (2 GHz), X-band (7 GHz up, 8 GHz down), and K-band (22.5 GHz up, 26 GHz down). Since there may be more than one spacecraft in the beamwidth of the DSN antennas, the DSN support will require an extension of the DSN’s capability to support multiple spacecraft using one antenna, expanding it to provide two simultaneous uplinks in the different bands at each antenna. Achieving this requires using new techniques for manufacturing the frequency selective surfaces, called dichroics, which steer the different frequency beams from and to the appropriate transmitting and receiving equipment, along with the addition of a new K-band uplink system. Additionally, due to the relative closeness of the moon from Earth (as opposed to the planetary missionsthe DSN supports daily), significantly higher data rates on both uplink and downlinkare requiredare possible and desirable by the lunar missions, specifically up to 20 Mbps on the uplink and 150 Mbps on the downlink, both using Low Density Parity Check (LDPC) error correcting codes. And, again due to the relative closeness of the moon, there is a need for low latency data delivery of the high rate downlink telemetry which requires a change in the current DSN paradigm of delivering higher rate data with higher latency.

Moon↗

TH-A-207B-00: Shear-Wave Imaging and a QIBA US Biomarker Update

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-01: Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-02: QIBA Ultrasound Elasticity Imaging System Biomarker Qualification and User Testing of Systems

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-00: Advances in Image-Guided Neurointerventions-Clinical Pull and Technology Push

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗