Search NASA⌕ Search

SEARCH · Search NASA

Results for “Referrer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Case Report: Differential diagnosis of hematuria in the emergency department: emphasizing double J stent-inferior vena cava fistula

Introduction Hematuria, a common clinical indicator of genitourinary tract pathology, arises from diverse etiologies including calculi, infections, malignancies, trauma, and iatrogenic causes. Initial evaluation requires hemodynamic assessment, identification of underlying causes, and urinary drainage optimization. This report highlights a rare case of iatrogenic hematuria secondary to double-J stent migration into the inferior vena cava. Case presentation A Chinese male presented with acute left flank pain and gross hematuria persisting for 4 h. Diagnostic imaging revealed a left ureteral stone, prompting double-J stent placement at a local hospital. Despite intervention, hematuria worsened, necessitating abdominal CT. Imaging identified proximal migration of the left double-J stent into the inferior vena cava, with no evidence of vascular injury. Due to concerns regarding inadequate drainage and infection risk, conservative management without catheter clamping was initiated prior to referral. Definitive treatment involved ureteroscopic stent removal under direct visualization at our institution, resulting in rapid symptom resolution. Conclusion This case emphasizes three critical clinical insights: (1) Persistent postoperative hematuria warrants consideration of iatrogenic causes, particularly following urologic device placement. (2) Imaging modalities, especially CT, are indispensable for detecting atypical stent migration. (3) Comprehensive history-taking must include prior urologic interventions to guide differential diagnosis. While double-J stent migration into major vessels remains exceptionally rare, its recognition prevents delayed management of potentially life-threatening complications. Clinicians should maintain heightened vigilance for device-related hematuria in patients with refractory symptoms post-procedurally, ensuring prompt imaging evaluation and multidisciplinary intervention when indicated.

Qi, Wenqi↗

“CY1” Chondrites Produced by Impact Dehydration of the CI Chondrite Parent Body

The recently proposed Yamato-type (CY) chondrites share significant similarities with CI chondrites and Ryugu. We present major and trace elemental, Re–Os, and mass-independent Ti, Cr, and Fe isotope data for seven CY chondrites. The elemental data along with isotopic compositions reveal two distinct lithologies, here designated as CY1 and CY2, potentially originating from two different parent bodies. Although sharing similarities with CM chondrites, CY2 chondrites have distinct Cr isotope compositions, arguing against a close genetic relationship. The CY1 lithology exhibits elemental abundances similar to CI chondrites/Ryugu as well as Fe, Ti, and Cr isotope compositions that closely overlap with those of CI chondrites/Ryugu. This suggests that CI chondrites, CY1 chondrites, and Ryugu accreted in the same region of the solar system and may even originate from the same parent body. In fact, we find that the reduced water content and certain volatile element abundances alongside increased sulfide content and mass-dependent O isotope enrichments observed in CY1 compared to CI chondrites could be attributed to an impact-induced heating event on the CI parent body. This impact likely disrupted the CI parent body, resulting in the ejection of both CI and CY1 lithologies. Furthermore, given that there are presently only five known CI meteorite specimens, the close chemical composition between CY1 and CI chondrites substantially expands the data set for comparisons and referrals to the bulk solar system composition for nonvolatile elements. Finally, we propose that the “CY1” chondrites could be called “CI1T,” while the designation “CY” chondrites could be restricted to “CY2” samples.

Zhu, Ke 朱柯 [China University of Geosciences (Wuhan↗

Screening and Brief Interventions for Alcohol Use During Pregnancy: Practices Among US Primary Care Clinicians, DocStyles 2019

Alcohol use during pregnancy can cause birth defects and developmental disabilities. From 2018 through 2020, 13.5% of pregnant women reported current drinking. The US Preventive Services Task Force recommends evidence-based tools (eg, AUDIT-C and SASQ) for implementing screening and brief interventions to reduce excessive alcohol use among adults, including pregnant people, for whom any alcohol use is considered excessive. We used DocStyles 2019 data to conduct a cross-sectional analysis to examine current screening and brief intervention practices that primary care clinicians conduct among pregnant patients; clinicians’ confidence levels in conducting screening, brief interventions, and referral to treatment; and the documentation of brief interventions in the medical record. A total of 1,500 US adult medicine clinicians completed the entire survey. Among the respondents who conduct screening (N = 1,373) and brief interventions (N = 1,357) in their practice, nearly all reported implementing screening (94.6%) and brief interventions (94.9%) with their pregnant patients for alcohol use, but fewer than half felt confident about conducting their screening practices (46.5%). Two-thirds (64%) reported using a tool that met the criteria recommended by the US Preventive Services Task Force (USPSTF). Over half documented brief interventions in electronic health record notes (51.7%) or designated space (50.7%). Pregnancy presents a unique opportunity for clinicians to incorporate screening into routine obstetric care and encourage behavior change among patients. Most providers reported always screening their pregnant patients for alcohol use, but fewer used evidence-based USPSTF-recommended screening tools. Increased clinician confidence in screening and brief intervention, the use of standardized screening tools tailored to pregnant people, and maximal use of electronic health record technology may enhance the benefits of their application to alcohol use, which ultimately can reduce adverse outcomes associated with alcohol use during pregnancy.

60 APPLIED LIFE SCIENCES↗

What is KASC ?

The organization and functions of the Knowledge Availability System Center are discussed. The KASC is defined as a nonprofit, computerized information center at the University of Pittsburgh. The KASC provides literature searching and referral services designed to identify useful scientific and technical data to its clients. Two types of service are provided: (1) the retrospective search, in which entire reference files are searched, and (2) the current awareness service which provides information on new developments and work being done in related fields. It is stated that the services provided by KASC will reduce duplication of expensive research and aid the movement of new knowledge across industrial, regional, and disciplinary boundaries.

Source record↗

Register of experts for information on mechanics of structural failure

A list of approximately 150 experts from approximately 60 organizations who have published results of theoretical and/or experimental research related to six problem areas in the mechanics of structural failure is presented. Each author included is listed by organizational affiliation, address and principal field of expertise. The initial criteria for the selection of names for the register are recent contributions to the literature, participation in or support of relevant research programs, and referral by peers. The purpose of the register is to present, in easy reference form, sources for dependable information regarding failure modes and mechanisms of aerospace structures. The Register includes two indexes: an alphabetical listing of the experts and an alphabetical listing of the organizations with whom they are affiliated.

Carpenter, J. L., Jr.↗

Register of experts for information on mechanics of structural failure

This register is comprised of a list of approximately 300 experts from approximately 90 organizations who have published results of theoretical and/or experimental research related to six problem areas in the mechanics of structural failure: (1) life prediction for structural materials, (2) fracture toughness testing, (3) fracture mechanics analysis; (4) hydrogen embrittlement; (5) protective coatings; and (6) composite materials. The criteria for the selection of names for the register are recent contributions to the literature, participation in or support of relevant research programs, and referral by peers. Each author included is listed by organizational affiliation, address, and principal field of expertise. The purpose of the register is to present, in easy reference form, sources for dependable information regarding failure modes and mechanisms of aerospace structures. The register includes two indexes; an alphabetical listing of the experts and an alphabetical listing of the organizations with whom they are affiliated.

Carpenter, J. L., Jr.↗

Remote-area health care delivery through space technology - STARPAHC

A joint NASA/HEW project called Space Technology Applied to Rural Papage Advanced Health Care (STARPAHC) has been developed to deliver quality health care to inhabitants of remote geographical areas. The system consists of a hospital-based support control center, a fixed clinic, a mobile clinic, and a referral center with access to specialists via television links to the control center. A strategically located relay station routes television, voice, and data transmissions between system elements. A model system has been installed on the Papage Indian Reservation in Arizona, and is undergoing a 2-year evaluation. The system has been shown to be both effective and cost-efficient, and applications of the concept are planned for future manned spacecraft flights.

Belasco, N.↗

Determination of some dominant parameters of the global dynamic sea surface topography from GEOS-3 altimetry

The 1977 altimetry data bank is analyzed for the geometrical shape of the sea surface expressed as surface spherical harmonics after referral to the higher reference model defined by GEM 9. The resulting determination is expressed as quasi-stationary dynamic SST. Solutions are obtained from different sets of long arcs in the GEOS-3 altimeter data bank as well as from sub-sets related to the September 1975 and March 1976 equinoxes assembled with a view to minimizing seasonal effects. The results are compared with equivalent parameters obtained from the hydrostatic analysis of sporadic temperature, pressure and salinity measurements of the oceans and the known major steady state current systems with comparable wavelengths. The most clearly defined parameter (the zonal harmonic of degree 2) is obtained with an uncertainty of + or - 6 cm. The preferred numerical value is smaller than the oceanographic value due to the effect of the correction for the permanent earth tide. Similar precision is achieved for the zonal harmonic of degree 3. The precision obtained for the fourth degree zonal harmonic reflects more closely the accuracy expected from the level of noise in the orbital solutions.

Mather, R. S.↗

HAL/S language specification. Version IR-542

The formal HAL/S language specification is documented with particular referral to the essentials of HAL/S syntax and semantics. The language is intended to satisfy virtually all of the flight software requirements of NASA programs. To achieve this, HAL/S incorporates a wide range of features, including applications oriented data types and organizations, real time control mechanisms, and constructs for systems programming tasks.

Source record↗

A methodology for evaluation of an interactive multispectral image processing system

Because of the considerable cost of an interactive multispectral image processing system, an evaluation of a prospective system should be performed to ascertain if it will be acceptable to the anticipated users. Evaluation of a developmental system indicated that the important system elements include documentation, user friendliness, image processing capabilities, and system services. The criteria and evaluation procedures for these elements are described herein. The following factors contributed to the success of the evaluation of the developmental system: (1) careful review of documentation prior to program development, (2) construction and testing of macromodules representing typical processing scenarios, (3) availability of other image processing systems for referral and verification, and (4) use of testing personnel with an applications perspective and experience with other systems. This evaluation was done in addition to and independently of program testing by the software developers of the system.

Kovalick, William M.↗

TRENDS: A flight test relational database user's guide and reference manual

This report is designed to be a user's guide and reference manual for users intending to access rotocraft test data via TRENDS, the relational database system which was developed as a tool for the aeronautical engineer with no programming background. This report has been written to assist novice and experienced TRENDS users. TRENDS is a complete system for retrieving, searching, and analyzing both numerical and narrative data, and for displaying time history and statistical data in graphical and numerical formats. This manual provides a 'guided tour' and a 'user's guide' for the new and intermediate-skilled users. Examples for the use of each menu item within TRENDS is provided in the Menu Reference section of the manual, including full coverage for TIMEHIST, one of the key tools. This manual is written around the XV-15 Tilt Rotor database, but does include an appendix on the UH-60 Blackhawk database. This user's guide and reference manual establishes a referrable source for the research community and augments NASA TM-101025, TRENDS: The Aeronautical Post-Test, Database Management System, Jan. 1990, written by the same authors.

Bondi, M. J.↗

National Center for Standards and Certification Information: Service and programs

The National Center for Standards and Certification Information (NCSCI) provides information on U.S., foreign and international voluntary standards, government regulations, and conformity assessment procedures for non-agricultural products. The Center serves as a referral service and focal point in the United States for information on standards and standards-related information. NCSCI staff respond to inquiries, maintain a reference collection of standards and standards-related documents, and serve as the U.S. inquiry point for information to and from foreign countries.

Overman, Joanne↗

An Expertise Recommender using Web Mining

This report explored techniques to mine web pages of scientists to extract information regarding their expertise, build expertise chains and referral webs, and semi automatically combine this information with directory information services to create a recommender system that permits query by expertise. The approach included experimenting with existing techniques that have been reported in research literature in recent past , and adapted them as needed. In addition, software tools were developed to capture and use this information.

Joshi, Anupam↗

Assessment of internal mammary artery and saphenous vein graft patency and flow reserve using transthoracic Doppler echocardiography

OBJECTIVE: To investigate transthoracic Doppler echocardiography in the identification of coronary artery bypass graft (CABG) flow for assessing graft patency. DESIGN: The initial study group comprised 45 consecutive patients with previous CABG undergoing elective cardiac catheterisation for recurrent ischaemia. The Doppler variables best correlated with angiographic graft patency were then tested prospectively in a further 84 patients (test group). SETTING: Three tertiary referral centres. INTERVENTIONS: Flow velocities in grafts were recorded at rest and during hyperaemia induced by dipyridamole (0.56 mg/kg/4 min), under the guidance of transthoracic colour Doppler flow mapping. Findings on transthoracic Doppler were compared with angiography. MAIN OUTCOME MEASURES: Feasibility of identifying open grafts by Doppler and diagnostic accuracy for Doppler detection of significant (>/= 70%) graft stenosis. RESULTS: In the test group the identification rate for mammary artery grafts was 100%, for saphenous vein grafts to left anterior descending coronary artery 91%, for vein grafts to right coronary artery 96%, and for vein grafts to circumflex artery 90%. Coronary flow reserve (the ratio between peak diastolic velocity under hyperaemia and at baseline) of < 1.9 (95% confidence interval 1.83 to 2.08) had 100% sensitivity, 98% specificity, 87.5% positive predictive value, and 100% negative predictive value for mammary artery graft stenosis. Coronary flow reserve of < 1.6 (95% CI 1.51 to 1.73) had 91% sensitivity, 87% specificity, 85.4% positive predictive value, and 92.3% negative predictive value for significant vein graft stenosis. CONCLUSIONS: Transthoracic Doppler can provide non-invasive assessment of CABG patency.

Multicenter Study↗

Similarity of urinary risk factors among stone-forming patients in five regions of the United States

Study Objective: To compare urinary biochemical risk factors among stone-forming patients in the Southeast (SE) or "stone belt" versus four other regions of the United States. Design: Prospective biochemical survey for regional comparisons. Setting: Referral-based nephrolithiasis clinics, urologists, nephrologists, and family practitioners. Patients: Consecutive sample of 3473 stone-forming patients who submitted 24-hour urine collections for biochemical analyses of stone-forming risk factors. Interventions: None. Subjects taking medication known to interfere with stone-forming risk factors were deleted from the final data compilation. Measurements and Main Results: Overall, the mean values for each urinary parameter spanned a narrow range without significant difference between the five regions. Among "metabolic" factors, 40% in the SE had hypercalciuria (> 6.25 mmol/d), compared to 35%-43% in other regions, and hyperuricosuria (> 4.2 mmol/d) was found in 16% in the SE versus 17%-19% elsewhere. Among "environmental" factors, low urine volume ( < 2 L/d) was found in 77% patients in the SE compared to 69%-78% elsewhere, and high sodium was encountered in 27% in the SE versus 24%-29% elsewhere. No differences were noted in occurrence of other abnormal risk factors: hyperoxaluria, hypocitraturia, low pH, high sulfate, high phosphorus, or low magnesium. Conclusions: Despite expected regional differences in nutritional and environmental influences, the results of this study showed a striking similarity in urinary biochemical risk factor profiles of stone-formers in all five regions of the United States.

NASA Discipline Number 18-10↗

A vestibular phenotype for Waardenburg syndrome?

OBJECTIVE: To investigate vestibular abnormalities in subjects with Waardenburg syndrome. STUDY DESIGN: Retrospective record review. SETTING: Tertiary referral neurotology clinic. SUBJECTS: Twenty-two adult white subjects with clinical diagnosis of Waardenburg syndrome (10 type I and 12 type II). INTERVENTIONS: Evaluation for Waardenburg phenotype, history of vestibular and auditory symptoms, tests of vestibular and auditory function. MAIN OUTCOME MEASURES: Results of phenotyping, results of vestibular and auditory symptom review (history), results of vestibular and auditory function testing. RESULTS: Seventeen subjects were women, and 5 were men. Their ages ranged from 21 to 58 years (mean, 38 years). Sixteen of the 22 subjects sought treatment for vertigo, dizziness, or imbalance. For subjects with vestibular symptoms, the results of vestibuloocular tests (calorics, vestibular autorotation, and/or pseudorandom rotation) were abnormal in 77%, and the results of vestibulospinal function tests (computerized dynamic posturography, EquiTest) were abnormal in 57%, but there were no specific patterns of abnormality. Six had objective sensorineural hearing loss. Thirteen had an elevated summating/action potential (>0.40) on electrocochleography. All subjects except those with severe hearing loss (n = 3) had normal auditory brainstem response results. CONCLUSION: Patients with Waardenburg syndrome may experience primarily vestibular symptoms without hearing loss. Electrocochleography and vestibular function tests appear to be the most sensitive measures of otologic abnormalities in such patients.

NASA Discipline Neuroscience↗

Estimation of cardiac reserve by peak power: validation and initial application of a simplified index

OBJECTIVES: To validate a simplified estimate of peak power (SPP) against true (invasively measured) peak instantaneous power (TPP), to assess the feasibility of measuring SPP during exercise and to correlate this with functional capacity. DESIGN: Development of a simplified method of measurement and observational study. SETTING: Tertiary referral centre for cardiothoracic disease. SUBJECTS: For validation of SPP with TPP, seven normal dogs and four dogs with dilated cardiomyopathy were studied. To assess feasibility and clinical significance in humans, 40 subjects were studied (26 patients; 14 normal controls). METHODS: In the animal validation study, TPP was derived from ascending aortic pressure and flow probe, and from Doppler measurements of flow. SPP, calculated using the different flow measures, was compared with peak instantaneous power under different loading conditions. For the assessment in humans, SPP was measured at rest and during maximum exercise. Peak aortic flow was measured with transthoracic continuous wave Doppler, and systolic and diastolic blood pressures were derived from brachial sphygmomanometry. The difference between exercise and rest simplified peak power (Delta SPP) was compared with maximum oxygen uptake (VO(2)max), measured from expired gas analysis. RESULTS: SPP estimates using peak flow measures correlated well with true peak instantaneous power (r = 0.89 to 0.97), despite marked changes in systemic pressure and flow induced by manipulation of loading conditions. In the human study, VO(2)max correlated with Delta SPP (r = 0.78) better than Delta ejection fraction (r = 0.18) and Delta rate-pressure product (r = 0.59). CONCLUSIONS: The simple product of mean arterial pressure and peak aortic flow (simplified peak power, SPP) correlates with peak instantaneous power over a range of loading conditions in dogs. In humans, it can be estimated during exercise echocardiography, and correlates with maximum oxygen uptake better than ejection fraction or rate-pressure product.

Non-NASA Center↗

Prognostic significance of electrical alternans versus signal averaged electrocardiography in predicting the outcome of electrophysiological testing and arrhythmia-free survival

OBJECTIVE: To investigate the accuracy of signal averaged electrocardiography (SAECG) and measurement of microvolt level T wave alternans as predictors of susceptibility to ventricular arrhythmias. DESIGN: Analysis of new data from a previously published prospective investigation. SETTING: Electrophysiology laboratory of a major referral hospital. PATIENTS AND INTERVENTIONS: 43 patients, not on class I or class III antiarrhythmic drug treatment, undergoing invasive electrophysiological testing had SAECG and T wave alternans measurements. The SAECG was considered positive in the presence of one (SAECG-I) or two (SAECG-II) of three standard criteria. T wave alternans was considered positive if the alternans ratio exceeded 3.0. MAIN OUTCOME MEASURES: Inducibility of sustained ventricular tachycardia or fibrillation during electrophysiological testing, and 20 month arrhythmia-free survival. RESULTS: The accuracy of T wave alternans in predicting the outcome of electrophysiological testing was 84% (p < 0.0001). Neither SAECG-I (accuracy 60%; p < 0.29) nor SAECG-II (accuracy 71%; p < 0.10) was a statistically significant predictor of electrophysiological testing. SAECG, T wave alternans, electrophysiological testing, and follow up data were available in 36 patients while not on class I or III antiarrhythmic agents. The accuracy of T wave alternans in predicting the outcome of arrhythmia-free survival was 86% (p < 0.030). Neither SAECG-I (accuracy 65%; p < 0.21) nor SAECG-II (accuracy 71%; p < 0.48) was a statistically significant predictor of arrhythmia-free survival. CONCLUSIONS: T wave alternans was a highly significant predictor of the outcome of electrophysiological testing and arrhythmia-free survival, while SAECG was not a statistically significant predictor. Although these results need to be confirmed in prospective clinical studies, they suggest that T wave alternans may serve as a non-invasive probe for screening high risk populations for malignant ventricular arrhythmias.

Non-NASA Center↗