Search NASA⌕ Search

SEARCH · Search NASA

Results for “Refilling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Simultaneous 100-kHz Acetone Planar Laser-Induced Fluorescence and OH* Chemiluminescence in a Linear Non-Premixed Detonation Channel

Reactant mixing and combustion are investigated in an optically accessible, self-excited linear detonation combustor. The mixing field is captured using 100 kHz planar laser-induced fluorescence (PLIF) imaging of acetone as a tracer in the fuel supply, while 100 kHz chemiluminescence imaging of excited-state hydroxyl (OH*) radicals simultaneously resolves the evolution of the detonation wave. Time sequences are acquired over multiple detonation cycles in each test, with acetone-PLIF images collected along multiple orthogonal planes to reveal the complex three-dimensional topography of the fuel distribution. The instantaneous and phase averaged acetone-PLIF images enable measurement of key fuel injection characteristics, such as the injector recovery time, fuel jet velocity, and refill height for a range of operating conditions. Instantaneous and phase-averaged measurements of acetone-PLIF with the time-coincident OH* chemiluminescence images also reveal a number key features, such as fuel stratification and weak detonation in the injector near field, incomplete combustion and deflagration behind the detonation wave, vitiation and deflagration of reactants ahead of the detonation wave, and fuel and oxidizer recovery time mismatch leading to combustion inefficiency. These measurements significantly enhance the ability to obtain detailed information on the intracycle and intercycle spatiotemporal evolution of the reactant refill process and its coupled effects on the detonation wave structure and propagation.

Propulsion↗

Testing and validation of the microbial environment of the NASA rodent spaceflight habitat water delivery system.

Sterilized, deionized water within a closed, self-sufficient system has been used in NASA spaceflight rodent studies for several decades. Within the specialized spaceflight rodent habitat, water is delivered through a compression spring-loaded bag system to maintain positive pressure. Refill of the drinking water occurs every 30 days by direct transfer of potable water from aboard the International Space Station (ISS). This enables long term use without a weekly water change out, which meets spaceflight requirements, but contrasts with the general guidelines for the sanitation of water delivery systems. Even though the water is iodinated to minimize microbial growth, rodents are fed a special diet of high moisture nutrient-rich food bars based on the AIN-93 diet that may contribute to microbial growth in this water system. We designed a ground study to assess the quality of drinking water that is given to rodents throughout a mission. We conducted the ground test using 20 female C57BL/6J mice housed in this specialized habitat to mimic the timeline of a 90-day mission as well as the environmental conditions (temperature, humidity, and pCO2) within the ISS. We used a novel sampling method to test water at 2-week intervals for the 90-days, and also after each 30-day refill of the water delivery system. Mice in standard vivarium cages with water bottles were also included for comparison to the habitat. The results showed that overall microbial load remained close to zero for the duration, while total organic compound concentrations increased from 1370g/L to 10650g/L over the course of 90 days but remained below the level of concern. Inorganic ions and pH were also found to be at acceptable levels. Overall, we conclude that this system is effective in delivering clean, potable water to rodents for the 90-day duration of current missions to the ISS.

water↗

Advanced Diagnostics for Megahertz Imaging of Mixing, Fuel Spray, and Combustion Processes for Rotating Detonation Combustors

Recent advancements in megahertz rate, high-power, burst-mode laser technology are leveraged to perform and explore imaging measurements that spatially and temporally resolve the mixing, combustion, and detonation flow field in two laboratory-scale rotating detonation combustors (RDCs). In a non-premixed annular RDC, multiple imaging diagnostics are explored to investigate gaseous and liquid injector behavior, the detonation wave structure, and the propellant refill. In one instance, OH planar laser-induced fluorescence (OH-PLIF) imaging is performed up to a 2 MHz repetition rate to track the combustion products and reaction zone locations. In the same annular RDC, a single liquid fuel jet is injected, and laser-based 355-nm imaging of the fuel spray is performed up to a 1 MHz repetition rate. For this configuration, the annular RDC is used as a detonation driver to impose periodic detonation waves to interact with the fuel spray. Moreover, in this annular RDC, a range of tracer-based laser imaging measurements are explored to time-resolve the unsteady oxidizer air recovery and refill process. In a non-premixed linear RDC, planar imaging measurements of the fuel mixing are performed up to a 200 kHz repetition rate using PLIF of a tracer in the fuel supply. The fuel mixing imaging helps explain the origin of the observed pre and post wave burning, detonation structure, and enables quantifying injector recovery timescales. This paper will provide a high-level broad survey of diagnostics applied in these RDCs, lessons learned, and interesting observations.

Combustion↗

Advanced Diagnostics For Megahertz Imaging Of Mixing, Fuel Spray, And Combustion Processes For Rotating Detonation Combustors

Recent advancements in megahertz rate, high-power, burst-mode laser technology are leveraged to perform and explore imaging measurements that spatially and temporally resolve the mixing, combustion, and detonation flow field in two laboratory-scale rotating detonation combustors (RDCs). In a non-premixed annular RDC, multiple imaging diagnostics are explored to investigate gaseous and liquid injector behavior, the detonation wave structure, and the propellant refill. In one instance, OH planar laser-induced fluorescence (OH-PLIF) imaging is performed up to a 2 MHz repetition rate to track the combustion products and reaction zone locations. In the same annular RDC, a single liquid fuel jet is injected, and laser-based 355-nm imaging of the fuel spray is performed up to a 1 MHz repetition rate. For this configuration, the annular RDC is used as a detonation driver to impose periodic detonation waves to interact with the fuel spray. Moreover, in this annular RDC, a range of tracer-based laser imaging measurements are explored to time-resolve the unsteady oxidizer air recovery and refill process. In a non-premixed linear RDC, planar imaging measurements of the fuel mixing are performed up to a 200 kHz repetition rate using PLIF of a tracer in the fuel supply. The fuel mixing imaging helps explain the origin of the observed pre and post wave burning, detonation structure, and enables quantifying injector recovery timescales. This paper will provide a high-level broad survey of diagnostics applied in these RDCs, lessons learned, and interesting observations.

Combustion↗

Embolism recovery strategies and nocturnal water loss across species influenced by biogeographic origin

Abstract Drought‐induced tree mortality is expected to increase in future climates with the potential for significant consequences to global carbon, water, and energy cycles. Xylem embolism can accumulate to lethal levels during drought, but species that can refill embolized xylem and recover hydraulic function may be able to avoid mortality. Yet the potential controls of embolism recovery, including cross‐biome patterns and plant traits such as nonstructural carbohydrates (NSCs), hydraulic traits, and nocturnal stomatal conductance, are unknown. We exposed eight plant species, originating from mesic (tropical and temperate) and semi‐arid environments, to drought under ambient and elevated CO 2 levels, and assessed recovery from embolism following rewatering. We found a positive association between xylem recovery and NSCs, and, surprisingly, a positive relationship between xylem recovery and nocturnal stomatal conductance. Arid‐zone species exhibited greater embolism recovery than mesic zone species. Our results indicate that nighttime stomatal conductance often assumed to be a wasteful use of water, may in fact be a key part of plant drought responses, and contribute to drought survival. Findings suggested distinct biome‐specific responses that partially depended on species climate‐of‐origin precipitation or aridity index, which allowed some species to recover from xylem embolism. These findings provide improved understanding required to predict the response of diverse plant communities to drought. Our results provide a framework for predicting future vegetation shifts in response to climate change.

54 ENVIRONMENTAL SCIENCES↗

Transmission Nuclear Resonance Fluorescence Measurements of 238U in Thick Targets

Transmission nuclear resonance fluorescence measurements were made on targets consisting of Pb and depleted U with total areal densities near 86 g/cm2. The 238U content n the targets varied from 0 to 8.5percent (atom fraction). The experiment demonstrates the capability of using transmission measurements as a non-destructive technique to identify and quantify the presence of an isotope in samples with thicknesses comparable to he average thickness of a nuclear fuel assembly. The experimental data also appear to demonstrate the process of notch refilling with a predictable intensity. Comparison of measured spectra to previous backscatter 238U measurements indicates general agreement in observed excited states. Two new 238U excited states and possibly a third state have also been observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Peptide assembly-driven metal-organic framework (MOF) motors for micro electric generators

Peptide–metal–organic framework (Pep-MOF) motors, whose motions are driven by anisotropic surface tension gradients created via peptide self-assembly around frameworks, can rotate microscopic rotors and magnets fast enough to generate an electric power of 0.1 μW. Finally, a new rigid Pep-MOF motor can be recycled by refilling the peptide fuel into the nanopores of the MOF.

36 MATERIALS SCIENCE↗

Hydraulic conductance, resistance, and resilience: how leaves of a tropical epiphyte respond to drought

Premise Because of its broad range in the neotropical rainforest and within tree canopies, the tank bromeliad Guzmania monostachia was investigated as a model of how varying leaf hydraulic conductance ( K leaf ) could help plants resist and recover from episodic drought. The two pathways of K leaf , inside and outside the xylem, were also examined to determine the sites and causes of major hydraulic resistances within the leaf. Methods We measured leaf hydraulic conductance for plants in the field and laboratory under wet, dry, and rewetted conditions and applied physiological, anatomical, and gene expression analysis with modeling to investigate changes in K leaf . Results After 7 d with no rain in the field or 14 days with no water in the glasshouse, K leaf decreased by 50% yet increased to hydrated values within 4 d of tank refilling. Staining to detect embolism combined with modeling indicated that changes outside the xylem were of greater importance to K leaf than were changes inside the xylem and were associated with changes in intercellular air spaces (aerenchyma), aquaporin expression and inhibition, and cuticular conductance. Conclusions Low values for all conductances during drying, particularly in pathways outside the xylem, lead to hydraulic resilience for this species and may also contribute to its broad environmental tolerances.

North, Gretchen B.↗

Modelling tree stem-water dynamics over an Amazonian rainforest

A novel tree stem-water model was developed to capture the dynamics of stem-water storage and its contribution to daily transpiration. The module was incorporated into the Community Land Model (CLM), where it was used to test model sensitivity to stem-water content for an evergreen rainforest site in Amazonia, that is, the BR-Sa3 eddy covariance site. With the inclusion of the stem-water storage, CLM produced greater dry-season latent heat flux that was closer to observations, facilitated by easier canopy access to a nearby stem-water source, rather than solely dependent on soil water. The simulated stem-water content also showed seasonal variations in magnitude, along with the seasonal variations in sap flow rate. Stored stem-water of a single mature tree was estimated to contribute 20–80 kg/day of water to transpiration during the wet season and 90–110 kg/day during the dry season, thereby partially replacing soil water and maintaining plant transpiration during the dry season. Diurnally, stem-water content declined as water was extracted for transpiration in the morning and then was refilled from soil water beginning in the afternoon and through the night. The dynamic discharge and recharge of stem storage was also shown to be regulated by multiple environmental drivers. Furthermore, our study indicates that the inclusion of stem capacitance in CLM significantly improves model simulations of dry-season water and heat fluxes, in terms of both magnitude and timing.

54 ENVIRONMENTAL SCIENCES↗

SERENA: Particle Instrument Suite for Determining the Sun-Mercury Interaction from BepiColombo

The ESA-JAXA BepiColombo mission to Mercury will provide simultaneous measurements from two spacecraft, offering an unprecedented opportunity to investigate magnetospheric and exospheric particle dynamics at Mercury as well as their interactions with solar wind, solar radiation, and interplanetary dust. The particle instrument suite SERENA (Search for Exospheric Refilling and Emitted Natural Abundances) is flying in space on-board the BepiColombo Mercury Planetary Orbiter (MPO) and is the only instrument for ion and neutral particle detection aboard the MPO. It comprises four independent sensors: ELENA for neutral particle flow detection, Strofio for neutral gas detection, PICAM for planetary ions observations, and MIPA, mostly for solar wind ion measurements. SERENA is managed by a System Control Unit located inside the ELENA box. In the present paper the scientific goals of this suite are described, and then the four units are detailed, as well as their major features and calibration results. Finally, the SERENA operational activities are shown during the orbital path around Mercury, with also some reference to the activities planned during the long cruise phase.

79 ASTRONOMY AND ASTROPHYSICS↗

PowderJet: Spherical metal powder production via multi-orifice droplet-on-demand metal jetting

Leading metal additive manufacturing techniques, such as laser powder bed fusion and directed energy deposition, rely on high-quality spherical metal powders. However, traditional powder production methods like gas atomization face limitations, including low in-spec yield, asphericity, and internal porosity. We introduce PowderJet, a powder production platform that uses electromagnetic pulses to eject liquid metal droplets from a multi-orifice nozzle. Unlike stochastic methods, PowderJet tightly controls powder size, distribution, and purity through a droplet-on-demand approach. We detail the system’s design, operation, and performance using a combined experimental and computational fluid dynamics (CFD) framework. Initial results with Al4008 and Cu110 alloys demonstrate successful production, yielding unsieved aluminum powder batches with a mean diameter of 200 µm and a narrow size distribution (15 µm standard deviation). The produced powders are highly spherical, achieving a roundness > 0.95. PowderJet operates with a small melt volume (3 mL) and supports continuous refilling, enabling production rates between 30 and 140 cm³/hr depending on jetting frequency, number of orifices and particle size. CFD simulations show that future systems could achieve rates exceeding 1000 cm³/hr for particle sizes as small as 40 µm. PowderJet’s high yield of in-spec powder makes it ideal for producing precious or hazardous materials that are inefficient to manufacture using conventional methods. This platform offers a scalable, precise, and efficient solution for producing high-quality powders tailored for advanced manufacturing applications.

Atomization↗

Solar-driven efficient methane catalytic oxidation over epitaxial ZnO/La 0.8 Sr 0.2 CoO 3 heterojunctions

Gas flaring in oil/gas drilling and gas leakage in natural gas power plant lead to significant energy loss and environmental burden. Here, solar-driven efficient methane oxidation was demonstrated under high velocity continuous flow over the ZnO/La 0.8 Sr 0.2 CoO 3 (ZnO/LSCO) heterojunctions. The ZnO/LSCO heterojunctions enable a unique epitaxial hetero-interface, which effectively regulates the electron transfer between Zn 3d -O 2p hybrid orbital in ZnO and Co e g orbital in LSCO and promotes the rapid generation and refill of oxygen vacancy with unpaired electron (V o ), thus enhancing the activity and mobility of surface lattice oxygen in ZnO/LSCO. Under solar illumination, the synergy of photothermal and photocatalytic effect boosts the reversible electron transfer in the interface, which further activates surface lattice oxygen, resulting in a ~2 times higher methane oxidation activity. Such a solar-driven system not only enables a promising pathway for emitted methane utilization, but also provides an advanced catalyst design concept of epitaxial interface construction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical modeling of a 2K J-T heat exchanger used in Fermilab Vertical Test Stand VTS-1

Fermilab Vertical Test Stand-1 (VTS-1) is in operation since 2007 for testing the superconducting RF cavities at 2 K. This test stand has single layer coiled finned tubes heat exchanger before J-T valve. A finite difference based thermal model has been developed in Engineering Equation Solver (EES) to study its thermal performance during filling and refilling to maintain the constant liquid level of test stand. The model is also useful to predict its performance under other various operating conditions and will be useful to design the similar kind of heat exchanger for future needs. Present paper discusses the different operational modes of this heat exchanger and its thermal characteristics under these operational modes. Results of this model have also been compared with the experimental data gathered from the VTS-1 heat exchanger and they are in good agreement with the present model.

2 Kelvin J-T Heat Exchanger↗

A hybrid Li-air battery with buckypaper air cathode and sulfuric acid electrolyte

We demonstrate a type of carbon nanotube based buckypaper cathode in a hybrid electrolyte Li-air battery (HyLAB) that showed outstanding discharging performances. The HyLAB has sulfuric acid as the catholyte and a large active electrode area (10 cm(2)). The active cathode layer was made from a buckypaper with 5 wt.% Pt supported on carbon nanotubes (Pt/CNTs) for oxygen reduction and evolution. A similar cathode was constructed with a catalyst of 5 wt.% Pt supported on carbon black (Pt/CB). It is demonstrated that sulfuric acid can achieve high discharging current densities while maintaining relatively high cell potentials. The cell with Pt/CNTs showed a much better performance than with Pt/CB at high current densities. The HyLAB with Pt/CNTs achieved a discharging capacity of 306 mAh/g and a cell voltage of 3.15 V at 0.2 mA/cm(2). The corresponding specific energy is 1067 Wh/kg based on the total weight of the sulfuric acid. Slow decrease in performance was observed, but it can be recovered by refilling the cell with new electrolyte after continuous discharging of more than 75 h. A charge-discharge experiment at 0.2 mA/cm(2) showed that the cell was rechargeable with a capacity of more than 300 mAh/g. (c) 2012 Elsevier Ltd. All rights reserved.

Li, YF↗

E-cigarettes as a source of toxic and potentially carcinogenic metals

Background and aims: The popularity of electronic cigarette devices is growing worldwide. The health impact of e-cigarette use, however, remains unclear. E-cigarettes are marketed as a safer alternative to cigarettes. The aim of this research was the characterization and quantification of toxic metal concentrations in five, nationally popular brands of cig-a-like e-cigarettes. Methods: We analyzed the cartomizer liquid in 10 cartomizer refills for each of five brands by Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Results: All of the tested metals (cadmium, chromium, lead, manganese and nickel) were found in the e-liquids analyzed. Across all analyzed brands, mean (SD) concentrations ranged from 4.89 (0.893) to 1970 (1540) μg/L for lead, 53.9 (6.95) to 2110 (5220) μg/L for chromium and 58.7 (22.4) to 22,600 (24,400) μg/L for nickel. Manganese concentrations ranged from 28.7 (9.79) to 6910.2 (12,200) μg/L. We found marked variability in nickel and chromium concentration within and between brands, which may come from heating elements. Conclusion: Additional research is needed to evaluate whether e-cigarettes represent a relevant exposure pathway for toxic metals in users. - Highlights: • Certain brands of cig-a-like e-cigarettes contain high levels of nickel and chromium. • Cig-a-likes contain low levels of cadmium, compared to tobacco cigarettes. • Nickel and chromium in the e-liquid of cig-a-likes may come from nichrome heating coils.

54 ENVIRONMENTAL SCIENCES↗

Are glass fiber particles released during the use of electronic cigarettes? Development of a semi-quantitative approach to detect glass particle emission due to vaping

This study investigated the emission characteristics of glass particles resulting from smoking electronic cigarettes (ECs). First, the most suitable filter for the collection of glass particles was explored by examining the performance (reliability) of various types of filters. A polycarbonate filter was determined as the optimum choice to collect glass particles in EC aerosol. A cartomizer was filled with EC refill solution composed of an equal volume of propylene glycol (PG) and vegetable glycol (VG). To simulate the potential conditions for glass particle emission, EC vaped aerosols were collected at three distinctive puffing intervals: (1) 0–10 puffs, (2) 101–110 puffs, and (3) 201–210 puffs (flow rate of 1 L min{sup −1}, 2 s per puff, and 10 puffs per sample). Glass particles were observed as early as after 100 times puffing from certain products, while after 200 from others. Thus, glass particles were generated by increasing the number of puffs and usage of the EC cartomizer. The analysis of glass particles collected onto polycarbonate filters by scanning electron microscopy (SEM)/energy dispersive X-ray spectroscopy (EDS) confirmed the presence of glass particles in samples collected after puffing 100–200 times. The study demonstrated that the possibility of glass particle emissions from the EC device increased considerably with the increasing number of total puffs.

54 ENVIRONMENTAL SCIENCES↗

Numerical investigation of mass flow rate effects on multiplicity of detonation waves within a H 2 /Air rotating detonation combustor

This paper presents results from numerical simulations of a non-premixed hydrogen-air rotating detonation combustor with radial injection. The fuel and air mass flow rate are varied in order to hold a unity global equivalence ratio. The calculations show that multiple detonation waves co-exist when the mass flow rate is increased. Conditional statistics of the detonation structure and combustion processes suggest similarities across co-existing waves. Quantification of the injection response to the rotation of a detonation indicates that at higher flow rate the refill time is short enough to allow for a quick and well mixed composition prior to the new front passage. Details of the combustion characteristics are analyzed. Finally, the results elucidate the correlation between initial injection conditions and detonation multiplicity on the overall physics within the combustor.

08 HYDROGEN↗

Modeling of hydrogen liquefaction using magnetocaloric cycles with permanent magnets

Hydrogen (H 2 ) is promising alternative to replace fossil fuels, but its transport and storage has been challenging. As H 2 fuel cell vehicles are gaining traction, the infrastructure for storing large amounts of liquid H 2 is needed. However, liquid H 2 would suffer from boil-off loss, and traditional vapor compression refrigeration systems would not be able to economically recover the lost H 2 due to the low efficiencies at cryogenic temperature. Magnetocaloric (MC) refrigeration systems could possess much higher coefficient of performance (COP) at cryogenic temperature compared to the vapor compression ones. Previous work on cryogenic MC systems, however, have only focused on large scale applications which use superconducting magnets to provide a large magnetic field but are prohibitively expensive to operate for small scale applications, such as that of a H 2 refilling station. In this work, we model the performance of a MC refrigeration cycle using 1-Tesla permanent magnets for H 2 liquefaction, with the objective of cooling H 2 from 80 K (using liquid nitrogen as the heat sink) to 20 K (boiling point of hydrogen). We evaluate main performance metrics including the total work input to the refrigeration system, COP, total MCM mass in the system, and total volume of the permanent magnets, etc. Our modeling results indicate that such a permanent magnet-based MC cooling system is feasible for small-scale H 2 liquefaction, with projected COP values significantly higher than those of vapor compression systems. In conclusion, this work provides design guidelines for future experimental efforts on permanent magnet MC cooling systems for cryogenic cooling.

08 HYDROGEN↗