NOAA-20 VIIRS polarization effect and its correction

The follow-on Visible Infrared Imaging Radiometer Suite (VIIRS) housed in the NOAA-20 satellite was launched on 18 November 2017. It has 22 spectral bands, among which 14 are reflective solar bands (RSBs) covering the wavelength range from 411 to 2258 nm. Prelaunch polarization sensitivity measurements have revealed that NOAA-20 VIIRS RSBs are much more sensitive to polarization of the incident light than its predecessor, the VIIRS on the Suomi National Polar-orbiting Partnership. For the short wavelength bands, i.e., M1–M4, the polarization sensitivities are out of specifications, especially for band M1, for which the polarization factors can be as large as ∼6%. The polarization effect induces striping in imagery along the track and radiometric bias both along the scan and along the track, resulting in much larger uncertainties in the environmental data records (EDR). In this paper, the polarization effect correction algorithms are described and applied to the NOAA-20 VIIRS RSBs for ocean scenes where the top-of-atmosphere radiance can be separated into the ocean normalized water-leaving radiance, the basis of the ocean color EDR, and the sunlight reflected by the atmosphere, which can be mostly described by the Rayleigh scattering radiance. The errors of the sensor data records (SDR or Level-1B radiance) due to the polarization effect can be as large as ∼1% for bands M1 and M2, and those in the ocean normalized water-leaving radiances are about 13% and 10% for wavelengths at 411 nm (band M1) and 445 nm (band M2), respectively. The polarization effect also induces strong striping in both NOAA-20 VIIRS RSB SDR and normalized water-leaving radiances. It is demonstrated that with the polarization correction applied, the aforementioned errors and artifacts are successfully removed.

NOAA-20↗

Suomi National Polar-Orbiting Partnership Visible Infrared Imaging Radiometer Suite Polarization Sensitivity Analysis

The Visible Infrared Imaging Radiometer Suite (VIIRS) is one of five instruments onboard the Suomi National Polar-Orbiting Partnership (SNPP) satellite that launched from Vandenberg Air Force Base, California, on October 28, 2011. It is a whiskbroom radiometer that provides +/-56.28deg scans of the Earth view. It has 22 bands, among which 14 are reflective solar bands (RSBs). The RSBs cover a wavelength range from 410 to 2250 nm. The RSBs of a remote sensor are usually sensitive to the polarization of incident light. For VIIRS, it is specified that the polarization factor should be smaller than 3% for 410 and 862 nm bands and 2.5% for other RSBs for the scan angle within +/-45deg. Several polarization sensitivity tests were performed prelaunch for SNPP VIIRS. The first few tests either had large uncertainty or were less reliable, while the last one was believed to provide the more accurate information about the polarization property of the instrument. In this paper, the measured data in the last polarization sensitivity test are analyzed, and the polarization factors and phase angles are derived from the measurements for all the RSBs. The derived polarization factors and phase angles are band, detector, and scan angle dependent. For near-infrared bands, they also depend on the half-angle mirror side. Nevertheless, the derived polarization factors are all within the specification, although the strong detector dependence of the polarization parameters was not expected. Compared to the Moderate Resolution Imaging Spectroradiometer on both Aqua and Terra satellites, the polarization effect on VIIRS RSB is much smaller.

Polar-Orbiting↗

MODIS and VIIRS On-Orbit Calibration and Characterization Using Observations from Spacecraft Pitch Maneuvers

Two MODIS instruments (Terra and Aqua) and two VIIRS instruments (S-NPP and JPSS-1) are currently operated inspace, continuously making global earth observations in the spectral range from visible (VIS) to long-wave infrared(LWIR). These observations have enabled a broad range of environmental data records to be generated and distributed insupport of both operational and scientific community. Despite extensive pre-launch calibration and characterizationperformed for both MODIS and VIIRS instruments and routine on-orbit calibration activities carried out using their onboardcalibrators (OBC), various spacecraft maneuvers have also been designed and implemented to further enhance thesensor on-orbit calibration and data quality. This paper focuses on the use of observations made during spacecraft pitchmaneuvers of MODIS and VIIRS in support of their on-orbit characterization of thermal emissive bands (TEB) responseversus scan-angle (RVS). In the case of Terra MODIS, lunar observations made from instrument nadir view duringspacecraft pitch maneuvers are used to compare with that made regularly through instrument space view (SV) port toevaluate on-orbit changes in RVS and band-to-band registration (BBR) for the reflective solar bands (RSB). In additionto results derived from spacecraft pitch maneuvers performed for MODIS and VIIRS, discussion is provided on theadvantages, challenges, and lessons for future considerations and improvements.

Xiong, Xiaoxiong↗

N20 VIIRS RSB Calibration Algorithms and Results: Collection 2.0

The NOAA-20 (N20) satellite, previously the Joint Polar Satellite System-1 satellite, was launched on November 18, 2017. One of the five major scientific instruments aboard the satellite is the Visible Infrared Imaging Radiometer Suite (VIIRS). VIIRS scans the Earth’s surface in 22 spectral bands, 14 of which are the reflective solar bands (RSBs) with band center wavelengths from 0.412 to 2.25μm. VIIRS regularly performs on-orbit radiometric calibration of its RSBs, primarily through the observations of the onboard solar diffuser (SD). The on-orbit change of the SD’s bidirectional reflectance distribution function, known as the H-factor, is determined by the onboard SD stability monitor (SDSM). Since the H-factor exhibits angular dependence, obtaining the H-factor along the SD to the telescope direction is a challenge for the NOAA-20 VIIRS. Recently, Collection 2.0 of the NASA Land Science Investigator-led Processing Systems (SIPS) products were released. As a part of this reprocessing effort, we made two major improvements in the N20 VIIRS RSB radiometric calibration. One is the improved SD and SDSM attenuation screen transmittance functions, obtained by using calibration data collected during both the yaw maneuver and a small portion of regular orbits, resulting in a higher quality H-factor for the SDSM view. Another is the use of the H-factor for the telescope view, derived from the H-factor for the SDSM view, by using the results for the SNPP VIIRS. In June 2019, we delivered a set of mission-long N20 VIIRS Collection 2.0 RSB radiometric calibration look-up-tables. These tables have been employed by the NASA Land SIPS group to reprocess the entire time series of the NOAA-20 VIIRS products. In this paper, we discuss the Collection 2.0 NOAA-20 VIIRS RSB calibration algorithms and results.

N20 VIIRS↗

On-Orbit Performance of MODIS Solar Diffuser Stability Monitor

Moderate Resolution Imaging Spectroradiometer (MODIS) is currently operated on both the Terra and Aqua spacecraft. It collects data in 20 reflective solar bands (RSB) and 16 thermal emissive bands. MODIS RSB calibration is reflectance based via an on-board solar diffuser (SD). On-orbit changes in the SD bidirectional reflectance factor are tracked by an onboard solar diffuser stability monitor (SDSM). The SDSM functions as an independent ratioing radiometer with nine filtered detectors, covering wavelengths in the visible (VIS) and near-infrared (NIR) spectral regions. A brief overview of SDSM design functions, on-orbit operations, and performance for both Terra and Aqua MODIS is provided. In addition to the SD on-orbit degradation at different wavelengths, the changes in SDSM detector responses and their potential impact on tracking SD on-orbit degradation are examined. After more than 12 years of on-orbit operation, Aqua MODIS SD has shown degradation varying from 0.6% at 0.94 microns to 19.0% at 0.41 microns. Due to more frequent solar exposure and longer operation time, the Terra MODIS SD has experienced a much larger degradation, varying from 2.3% at 0.94 microns to 48.0% at 0.41 microns. For both Terra and Aqua MODIS, the SD has experienced more degradation at shorter wavelengths. Meanwhile, the SDSM detector responses have also experienced wavelength-dependent degradation. The largest change in the SDSM detector responses, however, occurred at longer NIR wavelengths. Since launch, the SDSM systems on both Terra and Aqua MODIS have continued their nominal operations, enabling critical parameters to be derived in support of the RSB on-orbit calibration. The calibration strategies developed for and lessons learned from MODIS SDSM operations, and a preliminary performance comparison with the S-NPP VIIRS SDSM are discussed.

MODIS↗

Positional Dependence of SNPP VIIRS Solar Diffuser BRDF Change Factor: An Empirical Approach

The Earth-observing Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi National Polar-orbiting Partnership satellite regularly performs on-orbit radiometric calibration of its reflective solar bands (RSBs), primarily through observations of an onboard sunlit solar diffuser (SD). The on-orbit change of the SD bidirectional reflectance distribution function (BRDF) value, quantified by a numerical factor called the H-factor, is determined by the onboard SD stability monitor. Our previous study showed that the H-factor is solar angle and view direction dependent. In this study, we determine the dependence of the H-factor on the detector SD view footprint location. We fit an empirical model to the NASA Collection 1 SNPP VIIRS Level 1B (L1B) spectral reflectance difference across the detectors in an RSB over uniform Earth scenes of the Libya 4 desert and deep convective clouds. We apply the model predicted SD positional dependent H-factor to calibrate the RSBs. Under this new calibration scheme, the original unreal striping is removed from the homogeneous Libya 4 desert and the deep convective cloud images, as well as the original unreal striping from the Dunhuang desert image. The SD positional dependent H-factor has been used to calculate the SNPP VIIRS RSB radiometric correction factor for the NASA Collection 2.0 SNPP VIIRS L1B products.

SNPP VIIRS↗

Initial Investigation of the Angular Dependence of the NOAA-20 VIIRS Solar Diffuser BRDF Change Factor

The NOAA-20 (formerly the Joint Polar Satellite System-1) satellite was launched on November 18, 2017. One of the five scientific instruments aboard the NOAA-20 satellite (N20) is the Visible Infrared Imaging Radiometer Suite (VIIRS). The VIIRS scans the earth surface in 22 spectral bands, of which 14 are denoted as the reflective solar bands (RSBs) with design band central wavelengths from 412 to 2250 nm. The VIIRS regularly performs on-orbit radiometric calibration of its RSBs, primarily through observations of an onboard sunlit solar diffuser (SD). The on-orbit change of the SD bidirectional reflectance distribution function (BRDF) value, denoted as the H-factor, is determined by an onboard solar diffuser stability monitor (SDSM). We have shown that the H-factor for the SD on the VIIRS instrument on the Suomi National Polar-orbiting Partnership (SNPP) satellite is both incident and outgoing sunlight direction dependent. This angular dependence profoundly affects the on-orbit radiometric calibration process and results. Here, we give preliminary results for the angular dependence for the N20 VIIRS SD H-factor, and compare the dependence with that for the SNPP VIIRS.

radiometric calibration↗

Deconvolution of SNPP VIIRS Solar Diffuser Bidirectional Reflectance Distribution Function On-orbit Change Factor

The Earth-observing Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi National Polar-orbiting Partnership satellite regularly calibrates its reflective solar bands (RSBs), primarily through observing an onboard sunlit solar diffuser (SD). The on-orbit change of the value of the SD bidirectional reflectance distribution function (BRDF) is quantified by a numerical factor, called the H-factor, and is determined by the onboard SD stability monitor (SDSM). Because the spectral response function of an SDSM detector spreads in wavelength, the directly measured H-factor is the true H-factor convolved with the spectral response function. To find the true H-factor, we use the traditional direct method and an innovative iterative approach to separately deconvolve the measured H-factor. Our iterative approach relies on two properties of the SDSM detector spectral response function: the central peak width is narrow enough so that the H-factor does not change much over the peak width, and the dominance of the spectral response function’s integral with respect to the wavelength over the width. The iterative approach is more accurate, of a smaller noise impact, much more flexible in terms of interpolation and extrapolation of function values, and faster. We have used deconvolved H-factors to calibrate the NASA SNPP VIIRS RSB Collections 1 and 2 Level-1B products.

SNPP VIIRS↗

SNPP VIIRS RSB Earth View Reflectance Uncertainty

The Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi National Polar-orbiting Partnership (SNPP) satellite uses its 14 reflective solar bands to passively collect solar radiant energy reflected off the Earth. The Level 1 product is the geolocated and radiometrically calibrated top-of- the-atmosphere solar reflectance. The absolute radiometric uncertainty associated with this product includes contributions from the noise associated with measured detector digital counts and the radiometric calibration bias. Here, we provide a detailed algorithm for calculating the estimated standard deviation of the retrieved top-of-the-atmosphere spectral solar radiation reflectance.

VIIRS↗

GEO-LEO Reflective Band Inter-Comparison with BRDF and Atmospheric Scattering Corrections

The inter-comparison of the reflective solar bands (RSB) between the instruments onboard a geostationary orbit satellite and a low Earth orbit satellite is very helpful in assessing their calibration consistency. Himawari-8 was launched 7 October 2014 and GOES-R was launched on 19 November 2016. Unlike previous GOES instruments, the Advanced Himawari Imager (AHI) on Himawari-8 and the Advanced Baseline Imager (ABI) on GOES-R have onboard calibrators for the RSB. Independent assessment of calibration is nonetheless important to enhance their product quality. MODIS (Moderate Resolution Imaging Spectroradiometer) and VIIRS (Visible Infrared Imaging Radiometer Suite) can provide good references for sensor calibration. In this work, the inter-comparison between AHI and VIIRS is performed over a pseudo-invariant target. The use of stable and uniform calibration sites provides comparison with accurate adjustment for band spectral difference, reduction of impact from pixel mismatching, and consistency of BRDF (Bidirectional Reflectance Distribution Function) and atmospheric correction. The site used is the Strzelecki Desert in Australia. Due to the difference in solar and view angles, two corrections must be applied in order to compare the measurements. The first is the atmospheric scattering correction applied to the top of atmosphere reflectance measurements. The second correction is applied to correct the BRDF effect. The atmospheric correction is performed using a vector version of the Second Simulation of a Satellite Signal in the Solar Spectrum (6SV) model and the BRDF correction is performed using a semi-empirical model. Our results show that AHI band 1 (0.47 microns) has a good agreement with VIIRS band M3 within 0.15 percent. AHI band 5 (1.61 microns) shows the largest difference (5.09 percent) with VIIRS band M10, while AHI band 5 shows the least difference (1.87 percent) in comparison with VIIRS band I3. The methods developed in this work can also be directly applied to assess GOES-16/ABI (Geostationary Operational Environment Satellite16 / Advanced Baseline Imager) calibration consistency, a topic we will address in the future.

The inter-comparison of the reflective solar bands↗

SNPP VIIRS RSB on-orbit radiometric calibration algorithms Version 2.0 and the performances. Part II: The performances

In Part I (Lei et. al, submitted to J. of Appl. Rem. Sens.),we gave detailed reviews of the algorithms Version 2.0 used for the on-orbit radiometric calibration of the reflective solar bands (RSBs) of the first Visible Infrared Imaging Radiometer Suite instrument. These algorithms improve the accuracy of the measured on-orbit change factor of the solar diffuser bidirectional reflectance distribution function, the H-factor, and reveal that the H-factor is angle dependent. With the help of lunar observations and the improved H-factor, the algorithms give more accurate values for the RSB detector on-orbit F-factor changes (F-factor is a correction factor to the initially retrieved scene spectral radiance). In this paper we review the RSB radiometric calibration performances. We show the H-factor temporal trend, the estimated uncertainty of the retrieved H-factor, and the F-factor temporal trend. Additionally we show the detector signal-to-noise ratio (SNR), the estimated uncertainty of the top-of-the-atmosphere solar spectral reflectance, the reflectance temporal trend for the Libya 4 desert, and the differences in the reflectances among the SNPP and the NOAA-20 VIIRS, and the Aqua MODIS. Our results show that although the SNRs trend downwards, they exceed the requirements by large margins. The reflectances from the Libya 4 desert show that the SNPP VIIRS’ reflectance is higher than those of the Aqua MODIS and the NOAA-20 VIIRS.

on-orbit calibration↗

Twenty Years of Terra MODIS Spectral Performance using the Spectro-Radiometric Calibration Assembly

The Moderate Resolution Imaging Spectroradiometer (MODIS) instrument on-board the Terra spacecraft has provided valuable Earth data to the science community for the last 20 years. Equipped with several on-board calibrators (OBCs), MODIS has continued to operate nominally since its launch in December 1999. The Spectro-Radiometric Calibration Assembly (SRCA) is one such OBC that is able to provide on-orbit measurements of the MODIS reflective solar bands (RSBs) in radiometric, spatial and spectral modes. While the SRCA is operating in spectral mode, it is able to monitor the center wavelength (CW), bandwidth (BW) and in-band relative spectral response (RSR) of most RSBs. Prelaunch measurements of the CWs, BWs and RSRs of the RSBs were performed at the system level using the Spectral measurement Assembly (SpMA). Using both the prelaunch measurements and the measurements obtained on-orbit using the SRCA, the changes in the spectral response of the MODIS reflective bands can be monitored throughout the mission. This paper will provide a brief description of the spectral calibration approach and report on-orbit changes in these spectral performance parameters and their uncertainties over the last 20 years. It will also address changes to the SRCA operation on-orbit and their impact on measured spectral calibration results. Despite two decades in orbit, the spectral responses for most Terra MODIS reflective bands continue to remain within their design specifications.

MODIS↗

Product of the SNPP VIIRS SD Screen Transmittance and the SD BRDF (RSB) From Both Yaw Maneuver and Regular On-Orbit Data

To assure data quality, the Earth-observing Visible Infrared Imaging Radiometer Suite (VIIRS) regularly performs on-orbit radiometric calibrations of its 22 spectral bands. The primary calibration radiance source for the reflective solar bands (RSBs) is a sunlit solar diffuser (SD). During the calibration process, sunlight goes through a perforated plate (the SD screen) and then strikes the SD. The SD scattered sunlight is used for the calibration, with the spectral radiance proportional to the product of the SD screen transmittance and the SD bidirectional reflectance distribution function (BRDF). The BRDF is decomposed to the product of its value at launch and a numerical factor quantifying its change since launch. Therefore, the RSB calibration requires accurate knowledge of the product of the SD screen transmittance and the BRDF (RSB; launch time). Previously, we calculated the product with yaw maneuver data and found that the product had improved accuracy over the prelaunch one. With both yaw maneuver and regular on orbit data, we were able to improve the accuracy of the SDSM screen transmittance and the product for the solar diffuser stability monitor SD view. In this study, we use both yaw maneuver and a small portion of regular on-orbit data to determine the product for the RSB SD view.

Lei, Ning↗

Performance of MODIS Thermal Emissive Bands On-orbit Calibration Algorithms

Two nearly identical copies of the Moderate Resolution Imaging Spectroradiometer (MODIS) are currently operated on-board the Terra and Aqua spacecrafts, launched in December 1999 and May 2002, respectively. Together, they have produced an unprecedented amount of science data products, which are widely used for the studies of changes in the Earth's system of land, oceans, and atmosphere. MODIS is a cross-track scanning radiometer, which uses a two-sided scan mirror and collects data continuously over a wide scan angle range (+/-55 degree relative to the instrument nadir) each scan of 1.47 seconds. It has 36 spectral bands with wavelengths ranging from visible (VIS) to long-wave infrared (LWIR). MODIS bands 1-19 and 26 are the reflective solar bands (RSB) and bands 20-25 and 27-36 are the thermal emissive bands (TEB). MODIS was developed and designed with improvements made over its heritage sensors (such as AVHRR and Landsat) and, in particular, with more stringent calibration requirements. Because of this, MODIS was built with a set of state-of-art on-board calibrators (OBC), which include a solar diffuser (SD), a solar diffuser stability monitor (SDSM), a blackbody (BB), a spectroradiometric calibration assembly (SRCA), and a space view (SV) port. With the exception of view angle differences, MODIS OBC measurements and the Earth View (EV) observations are made via the same optical path. MODIS TEB have a total of 160 individual TEB detectors (10 per band), which are located on two cold focal plane assemblies (CFPA). For nominal on-orbit operation, the CFPA temperature is controlled at 83K via a passive radiative cooler. For the TEB, the calibration requirements at specified typical scene radiances are less than or equal to 1% with an exception for the fire detection (low gain) band. MODIS TEB on-orbit calibration is performed on a scan-by-scan basis using a quadratic calibration algorithm, and data collected from sensor responses to the onboard BB and SV. The BB serves as the thermal calibration source and the SV provides measurements for the sensor's background and offsets. MODIS on-board BB is a v-grooved plate with its temperature measured using 12 platinum resistive thermistors (PRT) uniformly embedded in the BB substrate. All the BB thermistors were characterized pre-launch with reference to the NIST temperature standards. Unlike typical BB operations in many heritage sensors, which have no temperature control capability, the MODIS on-board BB can be operated at any temperatures between instrument ambient (about 270K) and 315K and can also be varied continuously within this range. This feature has significantly enhanced the MODIS' capability of tracking and updating the TEB nonlinear calibration coefficients over its entire mission. Following a brief description of MODIS TEB on-orbit calibration methodologies and its onboard BB operational activities, this paper provides a comprehensive performance assessment of MODIS TEB quadratic calibration algorithm. It examines the scan-by-scan, orbit-by-orbit, daily, and seasonal variations of detector responses and associated impact due changes in the CFPA and instrument temperatures. Specifically, this paper will analyze the contribution by each individual thermal emissive source term (BB, scan cavity, and scan mirror), the impact on the Level 1 B data product quality due to pre-launch and on-orbit calibration uncertainties. A comparison of Terra and Aqua TEB on-orbit performance, lessons learned, and suggestions for future improvements will also be made.

Xiong, Xiaoxiong↗

MODIS Solar Diffuser On-orbit Performance

MODIS is a key instrument for the NASA Earth Observing System (EOS), currently operated on both the Terra and Aqua missions. Each MODIS instrument has 20 reflective solar bands (RSBs) and 16 thermal emissive bands (TEBs). MODIS RSB on-orbit calibration is reflectance based using an on-board solar diffuser (SD). The SD bi-directional reflectance factors (BRFs) were characterized pre-launch using reference diffuser samples, which are traceable to NIST reflectance standards. The SD BRF on-orbit degradation (or change) is tracked by another onboard device, called the solar diffuser stability monitor (SDSM). The SDSM is operated during each scheduled SD calibration event, making alternate observations of direct sunlight and the diffusely reflected sunlight from the SD. The time series of the ratios of SDSM's SD view to its Sun view provide SD degradation information. This paper presents and compares the Terra and Aqua MODIS SD on-orbit performance. Results show that the SD on-orbit degradation depends on the amount of solar exposure of the SD plate. In addition, it is strongly wavelengthdependent, with a larger degradation rate at shorter wavelengths. For Terra MODIS, an SD door anomaly occurred in May 2003 that led to a decision to fix the door permanently at an "open" position. Since then, the SD degradation rate has significantly increased due to more frequent solar exposure. As expected, the SD on-orbit performance directly impacts the RSB calibration performance. The lessons learned from MODIS on-orbit calibration will provide useful insights into the development and operation of future SD calibration systems.

Xiong, Xiaoxiong↗

Assessment of MODIS and VIIRS Solar Diffuser On-Orbit Degradation

Both MODIS and VIIRS instruments use a solar diffuser (SD) for their reflective solar bands (RSB) on-orbit calibration. On-orbit changes in SD bi-directional reflectance factor (BRF) are tracked by a solar diffuser stability monitor (SDSM) using its alternate measurements of the sunlight reflected off the SD panel and direct sunlight through a fixed attenuation screen. The SDSM calibration data are collected by a number of filtered detectors, covering wavelengths from 0.41 to 0.94 micrometers. In this paper we describe briefly the Terra and Aqua MODIS and S-NPP VIIRS SDSM on-orbit operation and calibration activities and strategies, provide an overall assessment of their SDSM on-orbit performance, including wavelength-dependent changes in the SDSM detector responses and changes in their SD BRF, and discuss remaining challenging issues and their potential impact on RSB calibration quality. Due to different launch dates, operating configurations, and calibration frequencies, the Terra and Aqua MODIS and S-NPP VIIRS SD have experienced different amount of SD degradation. However, in general the shorter the wavelength, the larger is the SD on-orbit degradation. On the other hand, the larger changes in SDSM detector responses are observed at longer wavelengths in the near infrared (NIR).

MODIS↗

Suomi-NPP VIIRS Solar Diffuser Stability Monitor Performance

When illuminated by the Sun, the onboard solar diffuser (SD) panel provides a known spectral radiance source to calibrate the reflective solar bands of the Visible Infrared Imaging Radiometer Suite on the Suomi-NPP satellite. The SD bidirectional reflectance distribution function (BRDF) degrades over time due to solar exposure, and this degradation is measured using the SD stability monitor (SDSM). The SDSM acts as a ratioing radiometer, comparing solar irradiance measurements off the SD panel to those from a direct Sun view. We discuss the design and operations of the SDSM, the SDSM data analysis, including improvements incorporated since launch, and present the results through 1000 days after launch. After 1000 days, the band-dependent H-factors, a quantity describing the relative degradation of the BRDF of the SD panel since launch, range from 0.716 at 412 nanometers to 0.989 at 926 nanometers. The random uncertainty of these H-factors is about 0.1 percent, which is confirmed by the similar standard deviation values computed from the residuals of quadratic exponential fits to the H-factor time trends. The SDSM detector gains have temperature sensitivity of up to about 0.36 percent per kelvin, but this does not affect the derived H-factors. An initial error in the solar vector caused a seasonal bias to the H-factors of up to 0.5 percent. The total exposure of the SD panel to UV light after 1000 orbits is equivalent to about 100 hours of direct sunlight illumination perpendicular to the SD panel surface.

Fulbright, Jon↗

An Overall Assessment of JPSS-2 VIIRS Radiometric Performance Based on Pre-Launch Testing

The Visible Infrared Imaging Radiometer Suite (VIIRS) on-board the second Joint Polar Satellite System (JPSS) completed its sensor level testing in February 2018. The JPSS-2 (J2) mission is scheduled to launch in 2022 and will be very similar to its two predecessor missions, the Suomi National Polar-orbiting Partnership (SNPP) mission, launched on 28 October 2011 and JPSS-1 (renamed NOAA-20) launched on 18 November 2017. VIIRS instrument has 22 spectral bands covering the spectrum between 0.4 and 12.6 μm: 14 reflective solar bands (RSB), 7 thermal emissive bands (TEB) and one day-night band (DNB). It is a cross-track scanning radiometer capable of providing global measurements through observations at two spatial resolutions, 375 m and 750 m at nadir for the imaging bands and moderate bands, respectively. This paper will provide an overview of J2 VIIRS characterization methodologies and calibration performance during the pre-launch testing phases performed by the National Aeronautics and Space Administration (NASA) VIIRS Characterization Support Team (VCST) to evaluate the at-launch baseline radiometric performance and generate the parameters needed to populate the sensor data record (SDR) Look-Up-Tables (LUTs). Our analysis results confirmed the good performance of J2 VIIRS, in general as good as previous VIIRS instruments and all non-compliances are expected to have low impact on data quality. Key sensor performance metrics include the signal to noise ratio (SNR), radiance dynamic range, reflective and emissive bands calibration performance, polarization sensitivity, spectral performance, response versus scan-angle (RVS) and scattered light response. A set of performance metrics generated during the pre-launch testing program will be compared to both the SNPP and JPSS-1 VIIRS sensors.

Oudrari, Hassan↗