Search NASA⌕ Search

SEARCH · Search NASA

Results for “Rehabilitation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Icing of flow conditioners in a closed-loop wind tunnel

Described are the results of an experiment which determined whether flow conditioning screens and honeycombs would ice up in a closed-loop icing wind tunnel when placed downstream of the heat exchanger and upstream of the spray bars. The experiment was performed in the Icing Research Tunnel (IRT) at NASA Lewis Research Center. The investigation involved two separate tests: one to find the icing characteristics of flow conditioners in the IRT, and the second to find the icing characteristics of flow conditioners in the proposed rehabilitation of the Altitude Wind Tunnel (AWT). Both experiments showed that the heat exchanger removed nearly all of the icing cloud so that icing of the flow conditioners would cause no serious tunnel performance degradation during the course of a day's run. Only extremely cold conditions caused frost formation on the flow conditioners. The significance of this frost formation was minimized because frost buildup on the heat exchanger caused a much more severe pressure drop than did icing of the flow conditioners.

Newton, James E.↗

Bone and muscle - The structural system in long duration space missions

Losses of bone mineral and muscle mass have been observed, and in varying degrees measured, following all long duration missions in space. These observations portend an unacceptable threat to the crews' ability to return to earth, without protracted rehabilitation, following periods of a year or more in microgravity. The impact to crew capabilities and productivity in space is not well understood. Past research has dealt with bone loss and muscle atrophy as two separate problems with little discernible relationship. This paper reviews the available information on both and suggests a combined structural approach for future research.

Buchanan, Paul↗

Clinical applications of computerized thermography

Computerized or digital, thermography is a rapidly growing diagnostic imaging modality. It has superseded contact thermography and analog imaging thermography which do not allow effective quantization. Medical applications of digital thermography can be classified in two groups: static and dynamic imaging. They can also be classified into macro thermography (resolution greater than 1 mm) and micro thermography (resolution less than 100 microns). Both modalities allow a thermal resolution of 0.1 C. The diagnostic power of images produced by any of these modalities can be augmented by the use of digital image enhancement and image recognition procedures. Computerized thermography has been applied in neurology, cardiovascular and plastic surgery, rehabilitation and sports medicine, psychiatry, dermatology and ophthalmology. Examples of these applications are shown and their scope and limitations are discussed.

Anbar, Michael↗

Telerobotics - Problems and research needs

With major emphasis on simulation, a university laboratory telerobotics facility permits problems to be approached by groups of graduate students. Helmet-mounded displays provide realism; the slaving of the display to the human operator's viewpoint gives a sense of 'telepresence' that may be useful for prolonged tasks. Using top-down three-dimensional model control of distant images allows distant images to be reduced to a few parameters to update the model used for display to the human operator in a preview mode to circumvent, in part, the communication delay. Also, the model can be used as a format for supervisory control and permit short-term local autonomous operations. Image processing algorithms can be made simpler and faster without trying to construct sensible images from the bottom. Control studies of telerobots lead to preferential manual control modes and basic paradigms for human motion and thence, perhaps, to redesign of robotic control, trajectory path planning, and rehabilitation prosthetics.

Stark, Lawrence↗

Programmable Cadence Timer

Electronic metronome paces users through wide range of exercise routines. Conceptual programmable cadence timer provides rhythmic aural and visual cues. Timer automatically changes cadence according to program entered by the user. It also functions as clock, stopwatch, or alarm. Modular pacer operated as single unit or as two units. With audiovisual module moved away from base module, user concentrates on exercise cues without distraction from information appearing on the liquid-crystal display. Variety of uses in rehabilitative medicine, experimental medicine, sports, and gymnastics. Used in intermittent positive-pressure breathing treatment, in which patient must rhythmically inhale and retain medication delivered under positive pressure; and in incentive spirometer treatment, in which patient must inhale maximally at regular intervals.

Hall, William A.↗

Liquid water content and droplet size calibration of the NASA Lewis Icing Research Tunnel

The icing research tunnel at the NASA Lewis Research Center underwent a major rehabilitation in 1986 to 1987, necessitating recalibration of the icing cloud. The methods used in the recalibration, including the procedure used to establish a uniform icing cloud and the use of a standard icing blade technique for measurement of liquid water content are described. PMS Forward Scattering Spectrometer and Optical Array probes were used for measurement of droplet size. Examples of droplet size distributions are shown for several median volumetric diameters. Finally, the liquid water content/droplet size operating envelopes of the icing tunnel are shown for a range of airspeeds and are compared to the FAA icing certification criteria.

Ide, Robert F.↗

Perception-action relationships reconsidered in light of spatial display instruments

Spatial display instruments convey information about both the identity and the location of objects in order to assist surgeons, astronauts, pilots, blind individuals, and others in identification, remote manipulations, navigation, and obstacle avoidance. Scientists believe that these instruments have not reached their full potential and that progress toward new applications, including the possibility of restoring sight to the blind, will be accelerated by advancing the understanding of perceptual processes. This stimulating challenge to basic researchers was advanced by Paul Bach-Y-Rita (1972) and by the National Academy of Science (1986) report on Electronic Aids for the Blind. Although progress has been made, new applications of spatial display instruments in medicine, space, aviation, and rehabilitation await improved theoretical and empirical foundations.

Shebilske, Wayne L.↗

Liquid water content and droplet size calibration of the NASA Lewis Icing Research Tunnel

The icing research tunnel at the NASA Lewis Research Center underwent a major rehabilitation in 1986 to 1987, necessitating recalibration of the icing cloud. The methods used in the recalibration, including the procedure used to establish a uniform icing cloud and the use of a standard icing blade technique for measurement of liquid water content are described. PMS Forward Scattering Spectrometer and Optical Array probes were used for measurement of droplet size. Examples of droplet size distributions are shown for several median volumetric diameters. Finally, the liquid water content/droplet size operating envelopes of the icing tunnel are shown for a range of airspeeds and are compared to the FAA icing certification criteria.

Ide, Robert F.↗

Dynamic inter-limb resistance exercise device for long-duration space flight

Essential for fitness on Earth, resistive exercise is even more important for astronauts, who must maintain muscle and bone strength in the absence of gravity. To meet this need, designers and scientists at NASA Ames Research Center, Life Science Division, have worked to develop more effective exercise devices for long-duration exposure to microgravity. One of these concepts is the Inter-Limb Resistance Device which allows the subject to exercise one limb directly against another, strengthening muscle groups in the arms, legs, and back. It features a modular harness with an inelastic cable and instrumented pulley. Forces similar to other high resistance exercise equipment are generated. Sensors in the pulley measure force and velocity for performance feedback display and data acquisition. This free-floating apparatus avoids vibration of sensitive experiments on board spacecraft. Compact with low mass, this hardware is also well suited for a 'safe haven' from radiation on board Space Station Freedom, and may prove useful in confined environments on Earth, such as Antarctic stations, submarines, and other underwater habitats. Potential spin-offs of this technology include products for personal strengthening and cardiovascular conditioning, rehabilitation of hospital patients, fitness exercise for the disabled, and retraining after sports injuries.

Schwandt, Douglas F.↗

Shock and vibration isolation for cyclic exercise in spacecraft

A unique feature of undisturbed space flight is vibration and weight free environments not available on Earth. On long flights, exercise and especially locomotor exercise will be required if the crew is to function in a relatively normal fashion and avoid lengthy rehabilitation on return to Earth. Exercise forces in the low frequency range can amount to 2 to 3 times crew body weight in the frequency range most critical to material science. Therefore, the amount of isolation will need to be orders of magnitude greater than present techniques. The following is a brief rationale of the need for these exercises and a description of exercise forces. Current isolation means and their deficiencies will be described, and a method capable of providing the isolation proposed and work to date will be mentioned.

Thornton, W.↗

U.S. commercial space policies - Implications for developing countries

Recent U.S. policy developments on the commercial use of space are summarized and their international implications are considered. Attention is given to successful applications of technology developed in space, including an implantable cancer medication system, an implantable defibrillator, an ultrasonic residual stress monitor, and aquaculture treatment techniques. NASA projects involving bioengineering and rehabilitation applications are summarized, and plans to investigate high-temperature superconductors in space are addressed. Recent agreements entred into by NASA for space commercial studies are reviewed.

Gillam, Isaac T., IV↗

US-USSR telemedicine consultation spacebridge to Armenia and Ufa

The Final Report on the U.S.-U.S.S.R. Telemedicine Consultation Spacebride to Armenia and Ufa is presented. The goal of this activity was to provide expert medical consultation to the Armenian medical personnel in the areas of plastic and reconstructive surgery, physical and psychological rehabilitation, public health, and epidemiology following the devastating earthquake in Dec. 1988. The U.S. and U.S.S.R. implementation teams developed new standards for medical information transmittal as well as protocols and schedules on how to conduct medical consultations. The consultations were provided to the Republic Diagnostic Center in Yerevan, U.S.S.R. by four U.S. medical centers: University of Utah/LDS Hospital, University of Texas, Maryland Institute for Emergency Medical Service Systems, and Uniformed Services University of the Health Sciences.

Source record↗

NASA project 1: Full-body dynamometer

In space, where the body does only a fraction of work it does on earth, muscle atrophy is a major concern. The bones and the muscles will begin to deteriorate after a short stay in weightlessness. Bone decalcification appears to be a major problem with extensive living in microgravity. Resistance exercise is not only essential to prevent muscle atrophy in space, it also helps to keep bone decalcification in check. For a space station, where the astronauts are expected to live for months at a time, exercise is especially important. Experts recommend about an hour and a half to two hours of exercise per day to keep the muscles in good condition in microgravity. The exercises will not only keep the astronauts in excellent physical condition, it will also make it easier for them to readjust to earth's gravity on return. The stationary bicycle and the treadmill have been the astronauts' primary sources of exercise since the 1970's. The major problem with both the stationary bicycle and the treadmill is that while they may keep the leg muscles from deteriorating in microgravity, they do little for muscles in the upper body. The National Aeronautics and Space Administration (NASA) is currently developing a full-body dynamometer (FBD), which will provide the astronauts with a full-body workout. It will also test the astronauts for muscle atrophy and rehabilitate the weakened muscle. The specification and the function structure for the FBD is presented.

Lu, Li-Dai↗

Exercise and osteoporosis: Methodological and practical considerations

Physical activity may have important implications for enhancing bone density prior to the initiation of space flight, for preserving bone density during zero gravity, and for rehabilitating the skeleton upon return to Earth. Nevertheless, the beneficial effects of exercise upon the skeleton have not been proven by controlled trials and no consensus exists regarding the type, duration, and intensity of exercise necessary to make significant alterations to the skeleton. The following sections review our current understanding of exercise and osteoporosis, examine some of the methodological shortcomings of these investigations, and make research recommendations for future clinical trials.

Block, Jon E.↗

The value of electrical stimulation as an exercise training modality

Voluntary exercise is the traditional way of improving performance of the human body in both the healthy and unhealthy states. Physiological responses to voluntary exercise are well documented. It benefits the functions of bone, joints, connective tissue, and muscle. In recent years, research has shown that neuromuscular electrical stimulation (NMES) simulates voluntary exercise in many ways. Generically, NMES can perform three major functions: suppression of pain, improve healing of soft tissues, and produce muscle contractions. Low frequency NMES may gate or disrupt the sensory input to the central nervous system which results in masking or control of pain. At the same time NMES may contribute to the activation of endorphins, serotonin, vasoactive intestinal polypeptides, and ACTH which control pain and may even cause improved athletic performances. Soft tissue conditions such as wounds and inflammations have responded very favorably to NMES. NMES of various amplitudes can induce muscle contractions ranging from weak to intense levels. NMES seems to have made its greatest gains in rehabilitation where directed muscle contractions may improve joint ranges of motion correct joint contractures that result from shortening muscles; control abnormal movements through facilitating recruitment or excitation into the alpha motoneuron in orthopedically, neurologically, or healthy subjects with intense sensory, kinesthetic, and proprioceptive information; provide a conservative approach to management of spasticity in neurological patients; by stimulation of the antagonist muscle to a spastic muscle stimulation of the agonist muscle, and sensory habituation; serve as an orthotic substitute to conventional bracing used with stroke patients in lieu of dorsiflexor muscles in preventing step page gait and for shoulder muscles to maintain glenohumeral alignment to prevent subluxation; and of course NMES is used in maintaining or improving the performance or torque producing capability of muscle. NMES in exercise training is our major concern.

Currier, Dean P.↗

Application of dexterous space robotics technology to myoelectric prostheses

Future space missions will require robots equipped with highly dexterous robotic hands to perform a variety of tasks. A major technical challenge in making this possible is an improvement in the way these dexterous robotic hands are remotely controlled or teleoperated. NASA is currently investigating the feasibility of using myoelectric signals to teleoperate a dexterous robotic hand. In theory, myoelectric control of robotic hands will require little or no mechanical parts and will greatly reduce the bulk and weight usually found in dexterous robotic hand control devices. An improvement in myoelectric control of multifinger hands will also benefit prosthetics users. Therefore, as an effort to transfer dexterous space robotics technology to prosthetics applications and to benefit from existing myoelectric technology, NASA is collaborating with the Limbs of Love Foundation, the Institute for Rehabilitation and Research, and Rice University in developing improved myoelectric control multifinger hands and prostheses. In this paper, we will address the objectives and approaches of this collaborative effort and discuss the technical issues associated with myoelectric control of multifinger hands. We will also report our current progress and discuss plans for future work.

Hess, Clifford↗

Selectively lockable knee brace

A knee brace for aiding in rehabilitation of damaged leg muscles includes upper and lower housings, normally pivotable, one relative to the other about the knee joint axis of a patient. The upper housing is attachable to the thigh of the patient above the knee joint, while the lower housing is secured to a stirrup which extends downwardly along the patient's leg and is attached to the patient's shoe. An actuation rod is carried within the lower housing and is coupled to a cable. The upper and lower housings carry cooperative clutch/brake elements which normally are disengaged to permit relative movement between the upper and lower housings. When the cable is extended, the clutch/brake elements engage and lock the housings together. A heel strike mechanism fastened to the stirrup and the heel of the shoe is connected to the cable to selectively extend the cable and lock the brace in substantially any position when the patient places weight on the heel.

Myers, Neill↗

A high performance two degree-of-freedom kinesthetic interface

This summary focuses on the kinesthetic interface of a virtual environment system that was developed at the Newman Laboratory for Biomechanics and Human Rehabilitation at M.I.T. for the study of manual control in both motorically impaired and able-bodied individuals.

Adelstein, Bernard D.↗