Search NASA⌕ Search

SEARCH · Search NASA

Results for “Relative permeability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Composite Crew Module (CCM) Permeability Characterization

In January 2007, the NASA Administrator chartered the NASA Engineering and Safety Center (NESC) to form an Agency team to design and build a composite crew module in 18 months in order to gain hands-on experience in anticipation that future exploration systems may be made of composite materials. One of the conclusions from this Composite Crew Module Primary Structure assessment was that there was a lack of understanding regarding the ability for composite pressure shells to contain consumable gases, which posed a technical risk relative to the use of a metallic design. After the completion of the Composite Crew Module test program, the test article was used in a new program to assess the overall leakage/permeability and identify specific features associated with high leak rates. This document contains the outcome of the leakage assessment.

Kirsch, Michael T.↗

An Initial Non-Equilibrium Porous-Media Model for CFD Simulation of Stirling Regenerators

The objective of this paper is to define empirical parameters (or closwre models) for an initial thermai non-equilibrium porous-media model for use in Computational Fluid Dynamics (CFD) codes for simulation of Stirling regenerators. The two CFD codes currently being used at Glenn Research Center (GRC) for Stirling engine modeling are Fluent and CFD-ACE. The porous-media models available in each of these codes are equilibrium models, which assmne that the solid matrix and the fluid are in thermal equilibrium at each spatial location within the porous medium. This is believed to be a poor assumption for the oscillating-flow environment within Stirling regenerators; Stirling 1-D regenerator models, used in Stirling design, we non-equilibrium regenerator models and suggest regenerator matrix and gas average temperatures can differ by several degrees at a given axial location end time during the cycle. A NASA regenerator research grant has been providing experimental and computational results to support definition of various empirical coefficients needed in defining a noa-equilibrium, macroscopic, porous-media model (i.e., to define "closure" relations). The grant effort is being led by Cleveland State University, with subcontractor assistance from the University of Minnesota, Gedeon Associates, and Sunpower, Inc. Friction-factor and heat-transfer correlations based on data taken with the NASAlSunpower oscillating-flow test rig also provide experimentally based correlations that are useful in defining parameters for the porous-media model; these correlations are documented in Gedeon Associates' Sage Stirling-Code Manuals. These sources of experimentally based information were used to define the following terms and parameters needed in the non-equilibrium porous-media model: hydrodynamic dispersion, permeability, inertial coefficient, fluid effective thermal conductivity (including themal dispersion and estimate of tortuosity effects}, and fluid-solid heat transfer coefficient. Solid effective thermal conductivity (including the effect of tortuosity) was also estimated. Determination of the porous-media model parameters was based on planned use in a CFD model of Infinia's Stirling Technology Demonstration Convertor (TDC), which uses a random-fiber regenerator matrix. The non-equilibrium porous-media model presented is considered to be an initial, or "draft," model for possible incorporation in commercial CFD codes, with the expectation that the empirical parameters will likely need to be updated once resulting Stirling CFD model regenerator and engine results have been analyzed. The emphasis of the paper is on use of available data to define empirical parameters (and closure models) needed in a thermal non-equilibrium porous-media model for Stirling regenerator simulation. Such a model has not yet been implemented by the authors or their associates. However, it is anticipated that a thermal non-equilibrium model such as that presented here, when iacorporated in the CFD codes, will improve our ability to accurately model Stirling regenerators with CFD relative to current thermal-equilibrium porous-media models.

Tew, Roy↗

Material condition assessment with eddy current sensors

Eddy current sensors and sensor arrays are used for process quality and material condition assessment of conducting materials. In an embodiment, changes in spatially registered high resolution images taken before and after cold work processing reflect the quality of the process, such as intensity and coverage. These images also permit the suppression or removal of local outlier variations. Anisotropy in a material property, such as magnetic permeability or electrical conductivity, can be intentionally introduced and used to assess material condition resulting from an operation, such as a cold work or heat treatment. The anisotropy is determined by sensors that provide directional property measurements. The sensor directionality arises from constructs that use a linear conducting drive segment to impose the magnetic field in a test material. Maintaining the orientation of this drive segment, and associated sense elements, relative to a material edge provides enhanced sensitivity for crack detection at edges.

Goldfine, Neil J.↗

Late Effects of Heavy Ion Irradiation on Ex Vivo Osteoblastogenesis and Cancellous Bone Microarchitecture

Prolonged spaceflight causes degeneration of skeletal tissue with incomplete recovery even after return to Earth. We hypothesize that heavy ion irradiation, a component of Galactic Cosmic Radiation, damages osteoblast progenitors and may contribute to bone loss during long duration space travel beyond the protection of the Earth's magnetosphere. Male, 16 week old C57BL6/J mice were exposed to high LET (56 Fe, 600MeV) radiation using either low (5 or 10cGy) or high (50 or 200cGy) doses at the NASA Space Radiation Lab and were euthanized 3 - 4, 7, or 35 days later. Bone structure was quantified by microcomputed tomography (6.8 micron pixel size) and marrow cell redox assessed using membrane permeable, free radical sensitive fluorogenic dyes. To assess osteoblastogenesis, adherent marrow cells were cultured ex vivo, then mineralized nodule formation quantified by imaging and gene expression analyzed by RT PCR. Interestingly, 3 - 4 days post exposure, fluorogenic dyes that reflect cytoplasmic generation of reactive nitrogen/oxygen species (DAF FM Diacetate or CM H2DCFDA) revealed irradiation (50cGy) reduced free radical generation (20-45%) compared to sham irradiated controls. Alternatively, use of a dye showing relative specificity for mitochondrial superoxide generation (MitoSOX) revealed an 88% increase compared to controls. One week after exposure, reactive oxygen/nitrogen levels remained lower(24%) relative to sham irradiated controls. After one month, high dose irradiation (200 cGy) caused an 86% decrement in ex vivo nodule formation and a 16-31% decrement in bone volume to total volume and trabecular number (50, 200cGy) compared to controls. High dose irradiation (200cGy) up regulated expression of a late osteoblast marker (BGLAP) and select genes related to oxidative metabolism (Catalase) and DNA damage repair (Gadd45). In contrast, lower doses (5, 10cGy) did not affect bone structure or ex vivo nodule formation, but did down regulate iNOS by 0.54 - 0.58 fold. Thus, both low and high doses of heavy ion irradiation cause time dependent, adaptive changes in redox state within marrow cells but only high doses (50, 200cGy) inhibit osteoblastogenesis and cause cancellous bone loss. We conclude space radiation has the potential to cause persistent damage to bone marrow derived stem and progenitor cells for osteoblasts despite adaptive changes in cellular redox state.

Tran, Luan Hoang↗

Relationship between proton motive force and potassium ion transport in Halobacterium halobium envelope vesicles

The permeability of Halobacterium halobium vesicle membranes to potassium ions was investigated, and possible mechanisms for the regulation of the gradient of protons by the transmembrane movement of these ions were studied. The lack of a potassium ion diffusion potential in the absence of valinomycin, light-induced electrical potentials in excess of the chemical potential difference for potassium ions, and direct measurements of potassium ion influx during illumination show that the membranes are relatively impermeable to these ions. As a result of sodium ion extrusion during illumination, chlorine ions and water must be lost and the vesicles collapse. The light-induced collapse of vesicles is diminished only if the influx of potassium ions is increased.

Lanyi, J. K.↗

Intracellular localization of a group II chaperonin indicates a membrane-related function

Chaperonins are protein complexes that are believed to function as part of a protein folding system in the cytoplasm of the cell. We observed, however, that the group II chaperonins known as rosettasomes in the hyperthermophilic archaeon Sulfolobus shibatae, are not cytoplasmic but membrane associated. This association was observed in cultures grown at 60 degrees C and 76 degrees C or heat-shocked at 85 degrees C by using immunofluorescence microscopy and in thick sections of rapidly frozen cells grown at 76 degrees C by using immunogold electron microscopy. We observed that increased abundance of rosettasomes after heat shock correlated with decreased membrane permeability at lethal temperature (92 degrees C). This change in permeability was not seen in cells heat-shocked in the presence of the amino acid analogue azetidine 2-carboxylic acid, indicating functional protein synthesis influences permeability. Azetidine experiments also indicated that observed heat-induced changes in lipid composition in S. shibatae could not account for changes in membrane permeability. Rosettasomes purified from cultures grown at 60 degrees C and 76 degrees C or heat-shocked at 85 degrees C bind to liposomes made from either the bipolar tetraether lipids of Sulfolobus or a variety of artificial lipid mixtures. The presence of rosettasomes did not significantly change the transition temperature of liposomes, as indicated by differential scanning calorimetry, or the proton permeability of liposomes, as indicated by pyranine fluorescence. We propose that these group II chaperonins function as a structural element in the natural membrane based on their intracellular location, the correlation between their functional abundance and membrane permeability, and their potential distribution on the membrane surface.

Cell Membrane/physiology/ultrastructure↗

Late Effects of Heavy-Ion Irradiation on Ex Vivo Osteoblastogenesis and Cancellous Bone Microarchitecture

Prolonged spaceflight causes degeneration of skeletal tissue with incomplete recovery even after return to Earth. We hypothesize that heavy-ion irradiation, a component of Galactic Cosmic Radiation, damages osteoblast progenitors and may contribute to bone loss during long duration space travel beyond the protection of the Earth's magnetosphere. Male, 16 week-old C57BL6/J mice were exposed to high-LET (56-Fe, 600MeV) radiation using either low (5 or 10cGy) or high (50 or 200cGy) doses at the NASA Space Radiation Lab and were euthanized 3-4, 7, or 35 days later. Bone structure was quantified by microcomputed tomography (6.8 μm pixel size) and marrow cell redox assessed using membrane permeable, free radical-sensitive fluorogenic dyes. To assess osteoblastogenesis, adherent marrow cells were cultured ex vivo, then mineralized nodule formation quantified by imaging and gene expression analyzed by RT-PCR. Interestingly, 3-4 days post-exposure, fluorogenic dyes that reflect cytoplasmic generation of reactive nitrogen/oxygen species (DAF-FM Diacetate or CM-H2DCFDA) revealed irradiation (50cGy) reduced free radical generation (20-45%) compared to sham-irradiated controls. Alternatively, use of a dye showing relative specificity for mitochondrial superoxide generation (MitoSOX) revealed an 88% increase compared to controls. One week after exposure, reactive oxygen/nitrogen levels remained lower (24%) relative to sham-irradiated controls. After one month, high dose irradiation (200 cGy) caused an 86% decrement in ex vivo nodule formation and a 16-31% decrement in bone volume to total volume and trabecular number (50, 200cGy) compared to controls. High dose irradiation (200cGy) up-regulated expression of a late osteoblast marker (BGLAP) and select genes related to oxidative metabolism (Catalase) and DNA damage repair (Gadd45). In contrast, lower doses (5, 10cGy) did not affect bone structure or ex vivo nodule formation, but did down-regulate iNOS by 0.54-0.58 fold. Thus, both low- and high-doses of heavy-ion irradiation cause time-dependent, adaptive changes in redox state within marrow cells but only high doses (50, 200cGy) inhibit osteoblastogenesis and cause cancellous bone loss. We conclude space radiation has the potential to cause persistent damage to bone marrow-derived stem and progenitor cells for osteoblasts despite adaptive changes in cellular redox state.

LATE EFFECTS OF HEAVY-ION IRRADIATION↗

The interaction of hydrogen with metal alloys

Hydrogen diffusion coefficients were measured for several alloys, and these were determined to be about the same at 25 C for all alloys investigated. The relation of structure, both metallurgical and crystallographic, to the observed hydrogen distribution on charging was investigated, as well as the role of hydride formation in the hydrogen resistance of metal alloys. An attempt was made to correlate the structures and compositions of metal alloys as well as other parameters with the ratios of their notched tensile strengths in hydrogen to that in helium, R(H2/He), which are believed to represent a measure of their hydrogen resistance. Evidence supports the belief that hydrogen permeability and hydrogen resistance are increased by smaller grain sizes for a given alloy composition.

Danford, M. D.↗

Progress of the LASL dry hot rock geothermal energy project

The possibilities and problems of extracting energy from geothermal reservoirs which do not spontaneously yield useful amounts of steam or hot water are discussed. The system for accomplishing this which is being developed first is a pressurized-water circulation loop intended for use in relatively impermeable hot rock. It will consist of two holes connected through the hot rock by a very large hydraulic fracture and connected at the surface through the primary heat exchanger of an energy utilization system. Preliminary experiments in a hole 2576 ft (0.7852 km) deep, extending about 470 ft (143 m) into the Precambrian basement rock underlying the Jemez Plateau of north-central New Mexico, revealed no unexpected difficulties in drilling or hydraulically fracturing such rock at a temperature of approximately 100 C, and demonstrated a permeability low enough so that it appeared probable that pressurized water could be contained by the basement rock. Similar experiments are in progress in a second hole, now 6701 ft (2.043 km) deep, about 1.5 miles (2.4 km) south of the first one.

Smith, M. C.↗

Sensible heat flux - Radiometric surface temperature relationship for eight semiarid areas

Measurements of sensible heat flux, radiometric surface temperature, air temperature, and wind speed made at eight semiarid rangeland sites were used to investigate the sensible heat flux-aerodynamic resistance relationship. The individual sites covered a wide range of vegetation (0.1-4 m tall) and cover (3%-95% bare soil) conditions. Mean values of k/B, a quantity related to the resistance of heat versus momentum transfer at the surface, for the individual sites varied between 3.5 and 12.5. A preliminary test of the utility of an excess resistance based on the mean value of k/B showed that the difference between the mean estimated and measured sensible heat fluxes varied +/- 60 W/sq m for the eight semiarid sites. For the eight sites the values of k/B were plotted against the roughness Reynolds number. The plot showed considerable scatter with values ranging between and beyond the theoretical curves for bluff rough and permeable rough surfaces.

Stewart, J. B.↗

A Study to Analyze the Permeation of High Density Gases and Propellant Vapors Through Single Layer Teflon or Teflon Structure Materials and Laminations

This report contains the results of a fifteen month analytical and experimental study of the leakage rate of the pressurant gases (N2, He) and the propellant vapors (N2O4,N2H4) through bladder structures consisting of two layers of Teflon separated by a metallic foil diffusion barrier containing microscopic or larger holes. Results were obtained for the steady state leakage rate through circular holes and long rectangular openings in the barrier for arbitrary thicknesses of the two Teflon layers. The effect of hole shape and relative hole position on the leakage rate were studied. The transient problem was analyzed and it was shown that steady state calculations are adequate for estimating the leakage rate. A computer program entitled "Diffusion Analyzer Program" was developed to calculate the leakage rate, both transient and steady state. Finally, the analytical results were compared to experimentally determined values of the leakage rate through a model laminated bladder structure. The results of the analysis are in good agreement with experiment. The experimental effort (Part II of the Bladder Permeation Program) measured the solubility, diffusion coefficient and permeability of helium, nitrogen and nitrogen tetroxide vapor through Teflon TFE and FEP membranes. Data were obtained in the temperature range of 25 to 100 C at pressures ranging from near vacuum to about 20 atmospheres. Results of the experimental effort were compared with the limited data previously reported. As a verification to the applicability of results to actual bladder systems, counter diffusion tests were performed with a laminated sample containing aluminum foil with a selected group of holes.

Johnson, R. L.↗

Evaluating Plant Suberin Mutants for Enhanced Water and Nutrient Uptake to Increase Biomass Production Under Elevated CO2 Concentrations

Spaceflight cabin environments such as the International Space Station (ISS) typically have elevated CO2(1500-7000 μmol mol-1), which can affect plant growth and development. On earth, findings from FACE (Free-Air CO2Enrichment) and climate change studies have shown that plants grown at elevated (~ 700 μmol mol-1) CO2contain reduced levels of essential elements such as nitrogen, zinc, and iron. We hypothesized that spacecraft environments with elevated CO2 might likewise result in less nutritious crops for human consumption. Literature showed that quantitative differences in root suberin content could determine the permeability of the internal plant tissues to both water and solutes. To evaluate if there was a correlation between growth under elevated CO2and root suberin content we grew Arabidopsis thaliana, wild type (WT)(col-0), esb1(Enhanced Suberin 1) and horst1(Hydroxylase of Root Suberized Tissue)under ambient (~ 420± 25μmol mol-1) and elevated (800 ± 25, 1600 ± 25, 4000 ± 25 μmol mol-1) CO2concentrations. Comparing the growth of esb1and horst1plants to WT under ambient and elevated CO2concentrations, esb1showed significantly (P-value < 0.05) lower total fresh biomass whereas the horst1exhibited no significant difference. RNA sequencing revealed genes related to water uptake or nutrient availability stress upregulated due to the exposure to 800 and 1600 μmol mol-1CO2.Comparing the elemental composition of leaf tissue between WT and horst1plants grown under elevated CO2,we found an overall decrease in elemental composition for WT, whereas horst1showed an average increase of 30-60 % in the elemental contentsat1600 μmol mol-1compared to plants grown at ambient CO2. In conclusion, our results showed that horst1like modification to edible crops could improve the nutritional (elemental) content to supplement astronaut’s diet.

Anirudha R Dixit↗

Isolation of Resistance-Bearing Microorganisms

To better exploit the principles of gas transport and mass transport during the processes of cell seeding of 3D scaffolds and in vitro culture of 3D tissue engineered constructs, the oscillatory cell culture bioreactor provides a flow of cell suspensions and culture media directly through a porous 3D scaffold (during cell seeding) and a 3D construct (during subsequent cultivation) within a highly gas-permeable closed-loop tube. This design is simple, modular, and flexible, and its component parts are easy to assemble and operate, and are inexpensive. Chamber volume can be very low, but can be easily scaled up. This innovation is well suited to work with different biological specimens, particularly with cells having high oxygen requirements and/or shear sensitivity, and different scaffold structures and dimensions. The closed-loop changer is highly gas permeable to allow efficient gas exchange during the cell seeding/culturing process. A porous scaffold, which may be seeded with cells, is fixed by means of a scaffold holder to the chamber wall with scaffold/construct orientation with respect to the chamber determined by the geometry of the scaffold holder. A fluid, with/without biological specimens, is added to the chamber such that all, or most, of the air is displaced (i.e., with or without an enclosed air bubble). Motion is applied to the chamber within a controlled environment (e.g., oscillatory motion within a humidified 37 C incubator). Movement of the chamber induces relative motion of the scaffold/construct with respect to the fluid. In case the fluid is a cell suspension, cells will come into contact with the scaffold and eventually adhere to it. Alternatively, cells can be seeded on scaffolds by gel entrapment prior to bioreactor cultivation. Subsequently, the oscillatory cell culture bioreactor will provide efficient gas exchange (i.e., of oxygen and carbon dioxide, as required for viability of metabolically active cells) and controlled levels of fluid dynamic shear (i.e., as required for viability of shear-sensitive cells) to the developing engineered tissue construct. This bioreactor was recently utilized to show independent and interactive effects of a growth factor (IGF-I) and slow bidirectional perfusion on the survival, differentiation, and contractile performance of 3D tissue engineering cardiac constructs. The main application of this system is within the tissue engineering industry. The ideal final application is within the automated mass production of tissue- engineered constructs. Target industries could be both life sciences companies as well as bioreactor device producing companies.

Venkateswaran, Kasthuri, J.↗

Oscillating Cell Culture Bioreactor

To better exploit the principles of gas transport and mass transport during the processes of cell seeding of 3D scaffolds and in vitro culture of 3D tissue engineered constructs, the oscillatory cell culture bioreactor provides a flow of cell suspensions and culture media directly through a porous 3D scaffold (during cell seeding) and a 3D construct (during subsequent cultivation) within a highly gas-permeable closed-loop tube. This design is simple, modular, and flexible, and its component parts are easy to assemble and operate, and are inexpensive. Chamber volume can be very low, but can be easily scaled up. This innovation is well suited to work with different biological specimens, particularly with cells having high oxygen requirements and/or shear sensitivity, and different scaffold structures and dimensions. The closed-loop changer is highly gas permeable to allow efficient gas exchange during the cell seeding/culturing process. A porous scaffold, which may be seeded with cells, is fixed by means of a scaffold holder to the chamber wall with scaffold/construct orientation with respect to the chamber determined by the geometry of the scaffold holder. A fluid, with/without biological specimens, is added to the chamber such that all, or most, of the air is displaced (i.e., with or without an enclosed air bubble). Motion is applied to the chamber within a controlled environment (e.g., oscillatory motion within a humidified 37 C incubator). Movement of the chamber induces relative motion of the scaffold/construct with respect to the fluid. In case the fluid is a cell suspension, cells will come into contact with the scaffold and eventually adhere to it. Alternatively, cells can be seeded on scaffolds by gel entrapment prior to bioreactor cultivation. Subsequently, the oscillatory cell culture bioreactor will provide efficient gas exchange (i.e., of oxygen and carbon dioxide, as required for viability of metabolically active cells) and controlled levels of fluid dynamic shear (i.e., as required for viability of shear-sensitive cells) to the developing engineered tissue construct. This bioreactor was recently utilized to show independent and interactive effects of a growth factor (IGF-I) and slow bidirectional perfusion on the survival, differentiation, and contractile performance of 3D tissue engineering cardiac constructs. The main application of this system is within the tissue engineering industry. The ideal final application is within the automated mass production of tissue- engineered constructs. Target industries could be both life sciences companies as well as bioreactor device producing companies.

Freed, Lisa E.↗

Carbon Dioxide Control System for a Mars Space Suit Life Support System

Carbon dioxide (CO2) control during Extravehicular Activities (EVAs) on Mars will be challenging. Lithium hydroxide (LiOH) canisters have impractical logistics penalties, and regenerable metal oxide (MetOx) canisters weigh too much. Cycling bed systems and permeable membranes that are regenerable in space vacuum cannot vent on Mars due to the high partial pressure of CO2 in the atmosphere. Although sweep gas regeneration is under investigation, the feasibility, logistics penalties, and failure modes associated with this technique have not been fully determined. TDA Research, Inc. is developing a durable, high-capacity regenerable adsorbent that can remove CO2 from the space suit ventilation loop. The system design allows sorbent regeneration at or above 6 torr, eliminating the potential for Martian atmosphere to leak into the regeneration bed and into the ventilation loop. Regeneration during EVA eliminates the consumable requirement related to the use of LiOH canisters and the mission duration limitations imposed by MetOx system. The concept minimizes the amount of consumable to be brought from Earth and makes the mission more affordable, while providing great operational flexibility during EVA. The feasibility of the concept has been demonstrated in a series of bench-scale experiments and a preliminary system analysis. Results indicate that sorbent regeneration can be accomplished by applying a 14 C temperature swing, while regenerating at 13 torr (well above the Martian atmospheric pressure), withstanding over 1,000 adsorption/regeneration cycles. This paper presents the latest results from these sorbent and system development efforts.

Alptekin, Gokhan↗

Recent Developments to the Porous Microstructure Analysis (PuMA) Software

Introduction The Porous Microstructure Analysis (PuMA) software is an open source framework for image-based simulation, primarily used to determine effective properties based on material microstructure. PuMA was originally developed for the study of NASA thermal protection materials; however, many of the solvers in PuMA have applicability to a broad range of materials science applications. PuMA version 3.2 computes material surface area, pore diameters, effective thermal conductivity, continuum and rarefied tortuosity, and permeability. For anisotropic materials, PuMA can estimate material orientation and compute anisotropic thermal conductivity and elasticity. In this talk, a brief overview of the PuMA software and underlying methods will be presented, as well as some recent and ongoing developments, including the use of immersed boundary methods for image-based simulation and the development of a new weave segmentation tool, called TomoSAM. Cut-Cell method for heat and mass transfer For simulations on complex microstructures, traditional unstructured meshing techniques often prove to be difficult and time-intensive. Voxel-based solvers, which represent the surface as a staircase structure, are relatively simple to implement but can lose accuracy when feature resolution is poor. In this work, we present a novel 3D cut-cell method for solving the variable coefficient Poisson equation on complex microstructures, suitable for the determination of effective thermal conductivity or tortuosity of a material. The method uses a Marching Cubes/Marching Squares surface reconstruction to create cut-cells and determine geometric quantities. A flux-correction method is extended to 3D, with least squares gradient reconstruction, to solve for the boundary fluxes in the cut-cells. Verification cases show the solver achieves globally 2nd order accuracy on complex microstructures. TomoSAM TomoSAM, a module of the PuMA software, has been developed as a plugin for 3D Slicer, a software platform used for 3D image processing and visualization. It utilizes the Segment Anything Model (SAM), a deep learning model capable of identifying objects and generating image masks based on minimal user input. This feature enables efficient segmentation of complex 3D datasets, particularly of woven materials, from tomography or similar imaging methods, reducing the need for manual segmentation.

Tomography↗

Recent Developments to the Porous Microstructure Analysis (PuMA) Software

The Porous Microstructure Analysis (PuMA) software is an open source framework for image-based simulation, primarily used to determine effective properties based on material microstructure. PuMA was originally developed for the study of NASA thermal protection materials; however, many of the solvers in PuMA have applicability to a broad range of materials science applications. PuMA version 3.2 computes material surface area, pore diameters, effective thermal conductivity, continuum and rarefied tortuosity, and permeability. For anisotropic materials, PuMA can estimate material orientation and compute anisotropic thermal conductivity and elasticity. In this talk, a brief overview of the PuMA software and underlying methods will be presented, as well as some recent and ongoing developments, including the use of immersed boundary methods for image-based simulation and the development of a new weave segmentation tool, called TomoSAM. Cut-Cell method for heat and mass transfer For simulations on complex microstructures, traditional unstructured meshing techniques often prove to be difficult and time-intensive. Voxel-based solvers, which represent the surface as a staircase structure, are relatively simple to implement but can lose accuracy when feature resolution is poor. In this work, we present a novel 3D cut-cell method for solving the variable coefficient Poisson equation on complex microstructures, suitable for the determination of effective thermal conductivity or tortuosity of a material. The method uses a Marching Cubes/Marching Squares surface reconstruction to create cut-cells and determine geometric quantities. A flux-correction method is extended to 3D, with least squares gradient reconstruction, to solve for the boundary fluxes in the cut-cells. Verification cases show the solver achieves globally 2nd order accuracy on complex microstructures. TomoSAM TomoSAM, a module of the PuMA software, has been developed as a plugin for 3D Slicer, a software platform used for 3D image processing and visualization. It utilizes the Segment Anything Model (SAM), a deep learning model capable of identifying objects and generating image masks based on minimal user input. This feature enables efficient segmentation of complex 3D datasets, particularly of woven materials, from tomography or similar imaging methods, reducing the need for manual segmentation.

Tomography↗

Multiplanar Synthetic Arrays and Their Application to Full-Scale Landing Gear Noise Source Identification

Identification and quantification of noise sources generated by the landing gears of large civil transports are critical for the development of viable abatement technologies that can be applied locally to affect solely the source regions. Leveraging validated computational data sets obtained from airframe noise simulations of a full-scale B777-300ER aircraft, a frame-work based on multiplanar synthetic arrays was developed to examine landing gear sources. The position of the arrays relative to the aircraft nose or main landing gears, the number of microphones in each array, and their distribution pattern were judiciously selected to provide adequate spatial resolution of the sources in the primary flyover, sideline, and upstream directions while maintaining reasonable signal-to-noise ratio and beamwidth over a wide frequency range. Overall, seven synthetic arrays with 800 microphones each, for a total of 5,600 microphones, were used in the framework. Fully synchronous synthetic pressure records at each microphone location were obtained from the simulated data sets via a Ffowcs-Williams and Hawkings integral approach, with flow quantities on a permeable data surface enclosing the source regions used as input. Various applications of synthetic multiplanar arrays to acoustic data analysis are presented; the advantages of the framework in properly resolving and identifying the B777 landing gear sources is demonstrated by comparing three-dimensional source distribution maps with those obtained from a synthetic version of the ground-based microphone array used during flight tests of the same aircraft.

airframe noise↗