Search NASA⌕ Search

SEARCH · Search NASA

Results for “Relative positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Effects of Temperature on the Interactions of Helium-Vacancy Clusters with Gliding Edge Dislocations in α-Fe

The interaction of helium-vacancy (He-V) clusters with a gliding a/2<111>{110} edge dislocation in a-Fe is investigated by molecular dynamics methods under a constant strain rate at temperatures of 100 to 600 K. A number of small HenVm (n/m = 0~4) clusters initially placed at different positions relative to the slip plane are comparatively studied. The results show that the interaction of He-V clusters with gliding edge dislocations depends on the helium-to-vacancy (He/V) ratio, the position of the clusters relative to the slip plane, the cluster size, and also temperature. The obstacle strength of the He-V clusters relevant to the dislocation motion generally increases with increasing He/V ratio at the same temperature, but decreases slightly with increasing temperature for the same He-V cluster. One of the interesting results is that He-V clusters do not move along with the dislocation, even at 600 K.

a-Fe↗

A multicenter study to quantify systematic variations and associated uncertainties in source positioning with commonly used HDR afterloaders and ring applicators for the treatment of cervical carcinomas

Purpose: The reconstruction of radiation source position in the treatment planning system is a key part of the applicator reconstruction process in high dose rate (HDR) brachytherapy treatment of cervical carcinomas. The steep dose gradients, of as much as 12%/mm, associated with typical cervix treatments emphasize the importance of accurate and precise determination of source positions. However, a variety of methodologies with a range in associated measurement uncertainties, of up to ±2.5 mm, are currently employed by various centers to do this. In addition, a recent pilot study by Awunor et al. [“Direct reconstruction and associated uncertainties of {sup 192}Ir source dwell positions in ring applicators using gafchromic film in the treatment planning of HDR brachytherapy cervix patients,” Phys. Med. Biol. 58, 3207–3225 (2013)] reported source positional differences of up to 2.6 mm between ring sets of the same type and geometry. This suggests a need for a comprehensive study to assess and quantify systematic source position variations between commonly used ring applicators and HDR afterloaders across multiple centers. Methods: Eighty-six rings from 20 European brachytherapy centers were audited in the form of a postal audit with each center collecting the data independently. The data were collected by setting up the rings using a bespoke jig and irradiating gafchromic films at predetermined dwell positions using four afterloader types, MicroSelectron, Flexitron, GammaMed, and MultiSource, from three manufacturers, Nucletron, Varian, and Eckert & Ziegler BEBIG. Five different ring types in six sizes (Ø25–Ø35 mm) and two angles (45° and 60°) were used. Coordinates of irradiated positions relative to the ring center were determined and collated, and source position differences quantified by ring type, size, and angle. Results: The mean expanded measurement uncertainty (k = 2) along the direction of source travel was ±1.4 mm. The standard deviation associated with the source position reproducibility was within ±1.0 mm for all afterloaders. Maximum source positional variations of 2.1 and 3.9, 1.8 and 5.4, and 2.3 and 3.4 mm were observed at standard treatment positions for the Ø26, Ø30, and Ø32 mm sized 45° and 60° rings, respectively. Mean positional differences between a majority of the rings were within ±1.0 mm. Mean positional differences between a majority of the intracenter ring sets were within the expanded measurement uncertainty. When comparing the 45°–60° source paths, mean differences of 1.6, 0.9, and 0.9 mm were observed across the Ø26, Ø30 (MicroSelectron), and Ø32 mm (GammaMed) rings, respectively. When comparing to manufacturer source path models, maximum offsets of 1.9 and 2.1, 2.6 and 2.3, and 0.8 and 1.6 mm were observed for the Ø26, Ø30 (MicroSelectron), and Ø30 mm (Flexitron) sized 45° and 60° rings, respectively. When comparing the audit to ring commissioning data of participating centers, mean differences of up to 2.4 mm were observed. Conclusions: A majority of the audited rings showed a good degree of manufacturer consistency; however, substantial positional variation observed between some rings emphasizes the importance of commissioning each ring before clinical use. Differences observed between audit and commissioning data also indicate some variation in source treatment positions across centers.

60 APPLIED LIFE SCIENCES↗

SU-F-J-43: Positional Variation of Implanted Fiducial Markers Over the Course of Image Guided Radiotherapy for Pancreatic Cancer

Purpose: Pancreas is a soft-tissue organ, implanted fiducials can change positions due to migration or tissue deformation. This study quantified positional variation of fiducials in IGRT for pancreatic cancer. Methods: 20 patients had at least 3 gold fiducials implanted in pancreas under EUS guidance. Patients had 4D-CT simulation for gated treatment. Daily gated OBI kV images (Turebeam) were used for positional alignment with fiducials for total of 25 or 28 fractions. Relative distances among 3 fiducials (d{sub 1–} {sub 2}, d{sub 1–3}, d{sub 2–3}) were measured from 4D-CT end-of-expiration phase bin; and from gated kV images in first, mid, and last fraction (n=180). Results: The median duration between implant and simulation was 11 (range 0–41) days. The median duration between simulation and first fraction was 17 (range 8–24) days. The median relative distance was 12 (range 4–78) mm for d{sub 1–2}, 24 (range 6–80) mm for d{sub 1–3}, and 19 (range 5–63) mm for d{sub 2–3}. The median deviation was 1 mm for d{sub 1–2}, d{sub 1–3}, d{sub 2–3} between simulation and first fraction, first and mid fraction, mid and last fraction (n=180). Two patients (10%) had deviation >= 5 mm (5, 11 mm) between simulation and first fraction. One patient (5%) had deviation >= 5 mm (11 mm) between first and mid fraction. No patient (0%) had deviation >= 5 mm between mid and last fraction. In all 3 cases with deviation >=5 mm, only one fiducial was significantly deviated. No clear evidence that deviation size was associated with time interval between implant and first fraction. Conclusion: Implanted gold fiducials were quite stable over time in their relative positions in pancreas. Our data suggested at least 3 fiducials are needed. In cases that one fiducial was significantly deviated in daily kV images, this fiducial should be excluded in image guidance.

60 APPLIED LIFE SCIENCES↗

Two-epoch Orbit Estimation for Wide Binaries Resolved in Hipparcos and Gaia

The Hipparcos catalog and its Double and Multiple System Annex (DMSA) lists 4099 components with individual proper motions and coordinates on the epoch 1991.25. Many of these long-period binary stars are also present in Gaia Data Release 2 (DR2). Using the available relative positions and proper motions separated by 24.25 yr, the equations of relative orbital motion can be solved for the two epoch eccentric anomalies, orbital period, and eccentricity. This method employs elimination of the linear Thiele–Innes unknowns and nonlinear optimization of the remaining condition equations. The quality of these solutions is compromised by the insufficient condition and modest precision of the Hipparcos astrometric data, as revealed by Monte Carlo simulations with artificially perturbed data points. The presence of multiple systems and optical pairs can also perturb the results. Limited experiments with artificial data indicate that useful estimates can be obtained with a 25 yr epoch difference for wide binaries with orbital periods up to ~500 yr. The prospects of this method dramatically improve with the proposed next-generation space astrometry missions such as Gaia-NIR and Theia, especially when additional conditions are included from astrometric or spectroscopic measurements. An ancillary catalog of cross-identification and astrometric information for 1295 double-star pairs cross-matched in Gaia DR2 and Hipparcos is also published.

79 ASTRONOMY AND ASTROPHYSICS↗

Sustainability impact assessment to improve food security of smallholders in Tanzania

The objective of this paper was to assess the sustainability impacts of planned agricultural development interventions, so called upgrading strategies (UPS), to enhance food security and to identify what advantages and risks are assessed from the farmer's point of view in regards to social life, the economy and the environment. We developed a participatory methodological procedure that links food security and sustainable development. Farmers in four different case study villages in rural Tanzania chose their priority UPS. For these UPS, they assessed the impacts on locally relevant food security criteria. The positive impacts identified were mainly attributed to increased agricultural production and its related positive impacts such as increased income and improved access to necessary means to diversify the diet. However, several risks of certain UPS were also indicated by farmers, such as increased workload, high maintenance costs, higher competition among farmers, loss of traditional knowledge and social conflicts. We discussed the strong interdependence of socio-economic and environmental criteria to improve food security for small-scale farmers and analysed several trade-offs in regards to UPS choices and food security criteria. We also identified and discussed the advantages and challenges of our methodological approach. In conclusion, the participatory impact assessment on the farmer level allowed a locally specific analysis of the various positive and negative impacts of UPS on social life, the economy and the environment. We emphasize that only a development approach that considers social, economic and environmental challenges simultaneously can enhance food security.

54 ENVIRONMENTAL SCIENCES↗

SU-F-T-644: Reproducibility of Target Position Using Moderate Voluntary Breath- Hold During Liver Stereotactic Ablative Radiotherapy

Purpose: To evaluate the reproducibility of target position using moderate voluntary breath-hold during liver stereotactic ablative radiotherapy (SABR). Methods: Two patients who underwent liver SABR on a Varian TrueBeam STx linac were used for this study. Fiducial markers were placed in and around the target in the liver as surrogates for the target position and motion. GTVs were contoured by assessing tumor extent on contrast enhanced CT. The PTV was created from the GTV by adding 2 mm margins to account for the residual motion during breath-holds. A portable biofeedback system was used to facilitate the breath-hold to a reproducible position. The Varian RPM system was used for gating the linac. Proceeding each treatment, orthogonal kV pairs were taken, and alignment to nearby bony anatomy was performed. Then the breath-hold CBCT was acquired to align the fiducial markers. On-line fluoroscopy was used to fine-tune the breath-hold gating thresholds to correlate with the positions of the fiducial markers. The inter-fraction reproducibility of the target was evaluated by the offsets of the daily breath-hold CBCTs from the paired kV matches as a direct measure of the target position relative to the bony anatomy. The intra-fraction reproducibility of the target position was assessed by the gated window of the RPM marker block for each fraction. Results: The absolute mean offsets between the CBCT and paired kV matches in the vertical, longitudinal, and lateral directions were 0.06 cm, 0.10 cm, and 0.06 cm for patient 1, and 0.37 cm, 0.62 cm, and 0.09 cm for patient 2. The gated window of the RPM marker block for the breath-hold for each fraction was within 0.63 ± 0.16 cm and 0.59 ± 0.12 cm for patients 1 and 2, respectively. Conclusion: Moderate voluntary breath-hold showed good inter- and intra-fraction reproducibility of target position during liver SABR.

60 APPLIED LIFE SCIENCES↗

Micro-Hall position sensing of magnetic nanowires.

The Hall voltage output of a micro-Hall magnetic sensor depends on the relative position of a magnetic nanowire with respect to its sensing area. Following this idea, we performed analytical calculations which show that, under certain conditions, these devices can track the position of a magnetic nanowire with subnanometer resolution. Our results suggest that micro-Hall sensors can be utilized to provide a direct electronic readout of the position of magnetic nanowires in their applications as biomolecular manipulators or dynamic components in micro- and nanoscale devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Daily Alignment Results of In-Room Computed Tomography-Guided Stereotactic Body Radiation Therapy for Lung Cancer

Purpose: To determine the extent of interfractional setup errors and day-to-day organ motion errors by assessing daily bone alignment results and changes in soft tissue tumor position during hypofractionated, in-room computed tomography (CT)-guided stereotactic body radiation therapy (SBRT) of lung cancer. Methods and Materials: Daily alignment results during SBRT were analyzed for 117 tumors in 112 patients. Patients received 40-50 Gy of SBRT in four to five fractions using an integrated CT-LINAC system. The free-breathing CT scans acquired during treatment setup were retrospectively realigned to match with each of the bony references and the gross tumor volume (GTV) defined on the reference CT by rigid-body registration, and the daily deviations were calculated. Results: The mean magnitude ({+-} SD) three-dimensional shift from the initial skin marks to the final bone-aligned positions was 9.4 {+-} 5.7 mm. The mean daily GTV deviation from the bone position was 0.1 {+-} 3.8 mm in the anterior-posterior direction, -0.01 {+-} 4.2 mm in the superior-inferior direction, and 0.2 {+-} 2.5 mm in the lateral direction. A clinically noteworthy trend (net change >5 mm in any direction) in GTV position relative to the bone was observed in 23 cases (20%). Conclusions: Soft tissue target position can change significantly beyond the motion envelope defined in the original internal target volume in four-dimensional CT-based treatment planning for SBRT of lung cancer. Additional margin should be considered for adequate coverage of interfractional changes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Heat- and light-induced transformations of Yb trapping sites in an Ar matrix

The low-lying electronic states of Yb isolated in a solid Ar matrix grown at 4.2 K are characterized through absorption and emission spectroscopy. Yb atoms are found to occupy three distinct thermally stable trapping sites labeled “red,” “blue,” and “violet” according to the relative positions of the absorption features they produce. Classical simulations of the site structure and relative stability broadly reproduced the experimentally observed matrix-induced frequency shifts and thus identified the red, blue, and violet sites as due to respective single substitutional (SS), tetravacancy (TV), and hexavacancy (HV) occupation. Prolonged excitation of the {sup 1}S → {sup 1}P transition was found to transfer the Yb population from HV sites into TV and SS sites. The process showed reversibility in that annealing to 24 K predominantly transferred the TV population back into HV sites. Population kinetics were used to deduce the effective rate parameters for the site transformation processes. Experimental observations indicate that the blue and violet sites lie close in energy, whereas the red one is much less stable. Classical simulations identify the blue site as the most stable one.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetically coupled pressure sensor

Measurement of pressure of a fluid in a vessel using a cantilever spring in the vessel; a magnet connected to the cantilever spring in the vessel; an electromagnet outside of the vessel operatively connected to the magnet and the cantilever spring in the vessel, wherein the electromagnet induces movement of the magnet and the cantilever spring in the vessel, and wherein the movement is related to the pressure of the fluid in the vessel; a receiving coil operatively positioned relative to the magnet, wherein movement of the cantilever spring and the magnet in the vessel creates an electromotive response in the coil; and a controller analyzer connected to the receiving coil, wherein the controller analyzer uses the electromotive response in the coil for measuring the pressure of the fluid in the vessel.

Kotovsky, Jack↗

Magnetically coupled pressure sensor

Measurement of pressure of a fluid in a vessel using a cantilever spring in the vessel; a magnet connected to the cantilever spring in the vessel; an electromagnet outside of the vessel operatively connected to the magnet and the cantilever spring in the vessel, wherein the electromagnet induces movement of the magnet and the cantilever spring in the vessel, and wherein the movement is related to the pressure of the fluid in the vessel; a receiving coil operatively positioned relative to the magnet, wherein movement of the cantilever spring and the magnet in the vessel creates an electromotive response in the coil; and a controller analyzer connected to the receiving coil, wherein the controller analyzer uses the electromotive response in the coil for measuring the pressure of the fluid in the vessel.

Kotovsky, Jack↗

Chapter 6: CPV Tracking and Trackers

This chapter explains the functional requirements of a concentrator photovoltaic (CPV) sun tracker. It derives the design specifications of a CPV tracker. The chapter presents taxonomy of trackers describing the most common tracking architectures, based on the number of axes, their relative position, and the foundation and placing of tracking drives. It deals with the structural issues related to tracker design, mainly related to structural flexure and its impact on the system's acceptance angle. The chapter analyzes the auto-calibrated sun tracking control, by describing the state of the art and its development background. It explores the sun tracking accuracy measurement with a practical example. The chapter discusses tracker manufacturing and tracker field works. It reviews survey of different types of tracker designs obtained from different manufacturers. Finally, the chapter deals with IEC62817, the technical standard developed for CPV sun trackers.

14 SOLAR ENERGY↗

Point Adversarial Self-Mining: A Simple Method for Facial Expression Recognition

In this article, we propose a simple yet effective approach, called point adversarial self mining (PASM), to improve the recognition accuracy in facial expression recognition (FER). Unlike previous works focusing on designing specific architectures or loss functions to solve this problem, PASM boosts the network capability by simulating human learning processes: providing updated learning materials and guidance from more capable teachers. Specifically, to generate new learning materials, PASM leverages a point adversarial attack method and a trained teacher network to locate the most informative position related to the target task, generating harder learning samples to refine the network. The searched position is highly adaptive since it considers both the statistical information of each sample and the teacher network capability. Other than being provided new learning materials, the student network also receives guidance from the teacher network. After the student network finishes training, the student network changes its role and acts as a teacher, generating new learning materials and providing stronger guidance to train a better student network. Here, the adaptive learning materials generation and teacher/student update can be conducted more than one time, improving the network capability iteratively. Extensive experimental results validate the efficacy of our method over the existing state of the arts for FER.

97 MATHEMATICS AND COMPUTING↗

SU-F-J-137: Intrafractional Change of the Relationship Between Internal Fiducials and External Breathing Signal in Pancreatic Cancer Stereotactic Body Radiation Therapy

Purpose: The use of respiratory gating for management of breathing motion during stereotactic body radiation therapy (SBRT) relies on a consistent relationship between the breathing signal and the actual position of the internal target. This relationship was investigated in patients treated for pancreatic cancer. Methods: Four patients with pancreatic cancer undergoing SBRT that had implanted fiducials in the tumor were included in this study. Treatment plans were generated based on the exhale phases (30–70%) from the pre-treatment 4DCT. The margin between the internal target volume (ITV) and the planning target volume was three mm. After patient setup using cone-beam CT, simultaneous fluoroscopic imaging and breathing motion monitoring were used during at least three breathing cycles to verify the fiducial position and to optimize the gating window. After treatment, fluoroscopic images were acquired for verification purposes and exported for retrospective analyses. Fiducial positions were determined using a template-matching algorithm. For each dataset, we established a linear relationship between the fiducial position and the anterior-posterior (AP) breathing signal. The relationships before and after treatment were compared and the dose distribution impact evaluated. Results: Seven pre- and post-treatment fluoroscopic pairs were available for fiducial position analyses in the superior-inferior (SI) and left-right (LR) directions, and five in the AP direction. Time between image acquisitions was typically six to eight minutes. An average absolute change of 1.2±0.7 mm (range: 0.1–1.7) of the SI fiducial position relative to the external signal was found. Corresponding numbers for the LR and AP fiducial positions were 0.9±1.0 mm (range: 0.2–3.0) and 0.5±0.4 mm (range: 0.2–1.2), respectively. The dose distribution impact was small in both the ITV and organs-at-risk. Conclusion: The relationship change between fiducial position and external breathing signal has been observed to be about 1 mm in four pancreas SBRT patients, leading to small dose distribution impact. Pettersson and Cervino are funded by a Varian Medical Systems grant.

60 APPLIED LIFE SCIENCES↗

Variance control in weak-value measurement pointers

The variance of an arbitrary pointer observable is considered for the general case that a complex weak value is measured using a complex valued pointer state. For the typical cases where the pointer observable is either its position or momentum, the associated expressions for the pointer's variance after the measurement contain a term proportional to the product of the weak value's imaginary part with the rate of change of the third central moment of position relative to the initial pointer state just prior to the time of the measurement interaction when position is the observable--or with the initial pointer state's third central moment of momentum when momentum is the observable. These terms provide a means for controlling pointer position and momentum variance and identify control conditions which, when satisfied, can yield variances that are smaller after the measurement than they were before the measurement. Measurement sensitivities which are useful for estimating weak-value measurement accuracies are also briefly discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structure of a monoclinic polymorph of human carbonic anhydrase II with a doubled a axis

The crystal structure of human carbonic anhydrase II with a doubled a axis from that of the usually observed monoclinic cell has been determined and refined to 1.4 Å resolution. The two molecules comprising the asymmetric unit are related by a noncrystallographic translation of ½ along a, but one of the molecules has two alternate orientations related by a rotation of approximately 2°. The crystal structure of human carbonic anhydrase II with a doubled a axis from that of the usually observed monoclinic unit cell has been determined and refined to 1.4 Å resolution. The diffraction data with h = 2n + 1 were systematically weaker than those with h = 2n. Consequently, the scaling of the data, structure solution and refinement were challenging. The two molecules comprising the asymmetric unit are related by a noncrystallographic translation of ½ along a, but one of the molecules has two alternate positions related by a rotation of approximately 2°. This rotation axis is located near the edge of the central β-sheet, causing a maximum distance disparity of 1.7 Å between equivalent atoms on the diametrically opposite side of the molecule. The crystal-packing contacts are similar to two sequential combined unit cells along a of the previously determined monoclinic unit cell. Abnormally high final R{sub cryst} and R{sub free} values (20.2% and 23.7%, respectively) are not unusual for structures containing pseudo-translational symmetry and probably result from poor signal to noise in the weak h-odd data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Climate, soil and plant functional types as drivers of global fine-root trait variation

Ecosystem functioning relies heavily on below-ground processes, which are largely regulated by plant fine-roots and their functional traits. However, our knowledge of fine-root trait distribution relies to date on local- and regional-scale studies with limited numbers of species, growth forms and environmental variation. We compiled a world-wide fine-root trait dataset, featuring 1115 species from contrasting climatic areas, phylogeny and growth forms to test a series of hypotheses pertaining to the influence of plant functional types, soil and climate variables, and the degree of manipulation of plant growing conditions on species fine-root trait variation. Most particularly, we tested the competing hypotheses that fine-root traits typical of faster return on investment would be most strongly associated with conditions of limiting versus favourable soil resource availability. We accounted for both data source and species phylogenetic relatedness. We demonstrate that: (i) Climate conditions promoting soil fertility relate negatively to fine-root traits favouring fast soil resource acquisition, with a particularly strong positive effect of temperature on fine-root diameter and negative effect on specific root length (SRL), and a negative effect of rainfall on root nitrogen concentration; (ii) Soil bulk density strongly influences species fine-root morphology, by favouring thicker, denser fine-roots; (iii) Fine-roots from herbaceous species are on average finer and have higher SRL than those of woody species, and N 2 -fixing capacity positively relates to root nitrogen; and (iv) Plants growing in pots have higher SRL than those grown in the field. Synthesis. This study reveals both the large variation in fine-root traits encountered globally and the relevance of several key plant functional types and soil and climate variables for explaining a substantial part of this variation. Climate, particularly temperature, and plant functional types were the two strongest predictors of fine-root trait variation. High trait variation occurred at local scales, suggesting that wide-ranging below-ground resource economics strategies are viable within most climatic areas and soil conditions.

54 ENVIRONMENTAL SCIENCES↗

Theoretical study of influencing factors on the dispersion of bulk band-gap edges and the surface states in topological insulators Bi{sub 2}Te{sub 3} and Bi{sub 2}Se{sub 3}

The dispersion of the band-gap edge states in bulk topological insulators Bi{sub 2}Te{sub 3} and Bi{sub 2}Se{sub 3} is considered within density functional theory. The dependences of this dispersion both on the approximation used for an exchange-correlation functional at fixed unit cell parameters and atomic positions and on these parameters and positions that are obtained upon structural relaxation performed using a certain approximated functional are analyzed. The relative position of the Dirac point of topologically protected surface states and the valence band maximum in the surface electronic structure of the topological insulators is discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗