Soft-short management and remediation in 10-year-old NiCds in Geo orbit
After 10 years in Geo orbit, during the spring 1993 eclipse season, soft shorts occurred in cells of two of the three batteries on the F2R spacecraft On battery #1, the cell soft short turned suddenly into a hard short; the resulting sudden 1.2V fall in battery voltage and rise in temperature was observed via telemetry. On battery #3, the deleterious impact of its soft short increased day by day, manifesting itself as a drop in battery voltage part-way through each eclipse, causing high loading on the remaining good battery. This paper reports how by planned charge management, including applying (against-the-book) overcharge ratios (C/D) exceeding 1.75, the battery #3 cell soft short was 'built down' until the cell voltage fade ceased. The problem with the battery #3 soft-shorted cell was fought with partial success throughout the latter half of the fall 93 season, and the lessons learned were applied to alleviate the problem during the spring 94 and fall 94 eclipse seasons. The life of the spacecraft was successfully prolonged until it was retired in March 1995.