Search NASA⌕ Search

SEARCH · Search NASA

Results for “Renewable Thermal Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Stability and control of power systems with high penetrations of inverter-based resources: An accessible review of current knowledge and open questions

As power system renewable energy penetrations increase, the ways in which key renewable technologies such as wind and solar photovoltaics (PV) differ from thermal generators become more apparent. Many studies have examined the variability and uncertainty of such generators and described how generation and load can be balanced for a wide variety of annual energy penetrations, at timescales from seconds to years. Another important characteristic of these resources is asynchronicity, the result of using inverters to interface the prime energy source with the power system as opposed to synchronous generators. Unlike synchronous generators, whose frequency of alternating current (AC) injection is physically coupled to the rotation of the machine itself, inverter based asynchronous generators do not share the same physical coupling with the generated frequency. These subtle differences impact the operations of power systems developed around the characteristics of synchronous generators. In this paper we review current knowledge and open research questions concerning the interplay between asynchronous inverter-based resources (IBRs) and cycle- to second-scale power system dynamics, with a focus on how stability and control may be impacted or need to be achieved differently when there are high instantaneous penetrations of IBRs across an interconnection. This work does not seek to provide a comprehensive review of the latest developments, but is instead intended to be accessible to any reader with an engineering background and an interest in power systems and renewable energy. As such, the paper includes basic material on power electronics, control schemes for IBRs, and power system stability; and uses this background material to describe potential impacts of IBRs on power system stability, operational challenges associated with large amounts of distributed IBR generation, and modern power system simulation trends driven by IBR characteristics.

14 SOLAR ENERGY↗

Optimal operation and sizing of pumped thermal energy storage for net benefits maximization

Abstract Current trends in the modern grid are leading to the development and deployment of energy storage to help integrate increasing variable renewable energy sources into the grid. This paper studies a pumped thermal energy storage (PTES) system for multiple grid services including energy arbitrage, frequency regulation, spinning and non‐spinning reserve, and resource adequacy. Optimal dispatch methods are proposed for individual services as well as value stacking from multiple services to maximize the economic benefits. Assessment results demonstrate the superiority of value stacking. Specifically, the study shows the maximum revenue from an individual grid service with a 30‐MWh PTES system was $522,520, while the value stacking could increase the benefits to $678,477. In addition, sensitivity analyses were conducted to explore the cost‐effectiveness of a PTES system with different combinations of power transfer limits and energy capacity. It was found that the power transfer limit had a greater impact than the energy capacity on the benefits. The proposed method could help determine the optimal duration of a future PTES system.

25 ENERGY STORAGE↗

A Critical Exploration of the Efficiency Impacts of Demand Response From HVAC in Commercial Buildings

Increasing quantities of renewable energy generation has yielded a need for greater energy storage capacity in power systems. Thermal storage in variable air volume (VAV) heating, ventilation, and air conditioning (HVAC) in commercial buildings has been identified as an inexpensive source of grid storage, but the true costs are not known. Recent literature explores the inefficiency associated with providing grid services from these HVAC-based demand response (DR) resources by employing a battery analogy to calculate round-trip efficiency (RTE). Results vary significantly across studies and in some cases reported efficiencies are strikingly low. This article has three objectives to address these prior results. First, we synthesize and expand on insights into existing literature by systematically exploring the potential causes for the discrepancies in results. We reinforce previous work indicating baseline modeling may drive differences across studies and deduce that control accuracy plays a role in the major differences between experiments and simulation. Second, we discuss why the RTE metric is problematic for DR applications, discuss another proposed metric, additional energy consumption (AEC), and propose an extension, which we call uninstructed energy consumption (UEC), to evaluate DR performance. Finally, we explore the merits of different metrics using experimental data and highlight UEC's reduced sensitivity to the characteristics of the DR signal than previously proposed metrics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Assessment of High Efficiency Variable Speed Air-Source Heat Pump in Cold Climate Applications

This project was part of an effort by ComEd's emerging technology program to evaluate the energy saving potential of new energy efficiency technologies. The focus of this technology assessment was to determine energy and peak demand savings potentials of a high efficiency variable speed, air-source, split system heat pump designed for cold climate applications. The results of this technology assessment will be used by CLEAResult to develop a new energy efficiency measure for Commonwealth Edison Company's incentive programs. The project utilized the National Renewable Energy Laboratory's (NREL) Thermal Test Facility to experimentally characterize cooling and heating performance of a high efficiency heat pump split system under varying outdoor climate conditions. The selected climate conditions represented summer and low temperature winter conditions in ComEd's service territory. The laboratory experimentation results were used to develop equipment performance curves required by EnergyPlus hourly simulation engine. Using typical meteorological year 3 weather data for the Chicago O'Hare airport, hourly building simulations (using the EnergyPlus engine) was utilized to estimate the annual energy savings of the high efficiency heat pump in comparison to a standard efficiency unit in the following U.S. Department of Energy (DOE) building codes program energy prototypes: Single-family residence; Strip mall; and Low-rise office.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the Economic Value of Underground Thermal Storage for Hybrid Geothermal Power

Solutions are needed to address resource adequacy in the electric power system for highly decarbonized systems. The storage duration, the length of time a storage device can provide continuous output at its rated capacity, must be sufficient to receive full credit toward resource adequacy. Longer peaks and high fractions of variable renewable generation have increased the required duration to potentially seasonal durations. Underground Thermal Energy Storage (UTES) can be adapted to a hybrid storage power plant or heating and cooling applications to satisfy the need for long-duration storage. In this study, we use the Renewable Energy Deployment System (ReEDS) capacity expansion model to evaluate the increase in value for an enhanced geothermal system (EGS) resources by adding UTES. In modeled scenarios, using geothermal without storage as a baseline we compare the increase in economic value for plants with a range of storage characteristics. The added value of a hybrid storage plant changes depending on assumptions including the length of storage duration, efficiency, and ability to charge storage from the grid during periods of low energy prices. Relating proposed characteristics for geothermal UTES hybrids to the modeled economic value provides insight into economically viable costs for developing UTES as well as what combination of technology characteristics and future energy and policy assumptions drive significant value increases.

capacity expansion model↗

Thermal Management of Wide-Bandgap Semiconductor Amplifiers Used for Plasma Heating and Control

Princeton Fusion Systems (PFS) has designed, built, and tested a Load Switch printed circuit board (PCB) to demonstrate the capabilities of 2 kV silicon carbide (SiC) cascodes in development by Qorvo towards plasma heating and control applications. Initial tests have been conducted at low power (~100 W) for validation with thermal finite element analysis (FEA) modeling performed by the National Renewable Energy Laboratory (NREL). Comparisons of experimental data with the thermal modeling results, along with considerations for operating in plasma systems, will be discussed.

CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SU↗

Performance of an Isobaric Hybrid Compressed Air Energy Storage System at Minimum Entropy Generation

Efficient, large-scale, and cost-effective energy storage systems provide a means of managing the inherent intermittency of renewable energy sources and drastically increasing their utilization. Compressed air energy storage (CAES) and its derivative architectures have received much attention as a viable solution; however, optimization objectives for these systems have not been thoroughly investigated in the literature. In this work, a hybrid thermal and compressed air energy storage (HT-CAES) system is investigated that mitigates the shortcomings of the otherwise attractive conventional CAES systems and its derivatives—shortcomings such as strict geological locations, low energy densities, and the production of greenhouse gas emissions. The HT-CAES system allows a portion of the available energy to operate a compressor and the remainder to be converted and stored in the form of heat through joule/resistive heating in a high-temperature, sensible, thermal energy storage medium. Internally reversible and irreversible HT-CAES system assumptions were investigated, in addition to regenerative and non-regenerative design configurations. Several system optimization criteria were examined—including maximum energy efficiency, maximum exergy efficiency, maximum work output, and minimum entropy generation—with a focus on whether the latter may lead to conclusive design guidelines in a real system. It is shown that an HT-CAES system designed based on a minimum entropy generation objective may operate at a lower energy and exergy efficiency as well as lower output power than otherwise achievable. Furthermore, optimization objective equivalence is shown to be limited to certain design conditions.

25 ENERGY STORAGE↗

Study of Storage Requirements and Costs for Shaping Renewables and Nuclear Energy (FY23 Summary Report)

To decarbonize electricity generation primarily by using wind and solar resources, it is likely that additional low (or zero) carbon dioxide (CO 2 ) alternatives will be required for ensuring a reliable electricity supply. This study extends the work and modeling framework that we consolidated in FY 2022, by assessing the zero-CO 2 pathways of a Texas power system in which the availability of variable renewable energy (VRE), nuclear energy, and energy storage types (i.e., battery and thermal energy storage [TES]) are considered the sole resources available for expansion. Using the Risk Analysis Virtual Environment (RAVEN) and Holistic Energy Resource Optimization Network (HERON) frameworks, this study investigates the market of two nuclear energy technologies (i.e., large light-water reactors [LWRs] and LWR-type small modular reactors [SMRs]) under two plausible storage coupling scenarios (i.e., electric coupling and direct thermal coupling). We also explore optimal environments for nuclear energy deployment, and identify key performance characteristics that make nuclear energy economically viable in areas with significant intermittent energy sources. Our analysis encompasses 24 cases. We model the least-cost grid systems, highlight the potential for a coupled LWR-TES approach, and utilize SMRs to achieve deep decarbonization in an affordable, technically feasible manner. We also examine seasonal variations in balancing electricity supply and demand, and account for varying performance, costs, and grid constraints. Overall, the findings of our modeling afford valuable insights for supporting future technology investment decisions in the energy sector.

25 ENERGY STORAGE↗

A Configuration Based Pumped Storage Hydro Model in the MISO Day-Ahead Market

Pumped storage hydro units (PSHU) can provide flexibility to power systems. This becomes particularly valuable in recent years with the increasing shares of intermittent renewable resources. However, due to emphasis on thermal generation in the current market practices, the flexibility from PSHUs have not been fully explored and utilized. This paper proposes a configuration based pumped storage hydro (PSH) model for the day-ahead market, in order to enhance the use of PSH resources in the system. A strategic design of incorporating and fully optimizing PSHUs in the day-ahead market is presented. Here, we show the compactness of the proposed model. Numerical studies are presented in an illustrative test system and the Midcontinent Independent System Operator (MISO) system.

13 HYDRO ENERGY↗

Phase change materials for thermal energy storage: A perspective on linking phonon physics to performance

Thermal energy storage is being actively investigated for grid, industrial, and building applications for realizing an all-renewable energy world. Phase change materials (PCMs), which are commonly used in thermal energy storage applications, are difficult to design because they require excellent energy density and thermal transport, both of which are difficult to predict from simple physics-based models. In this Perspective, we describe recent advances in the understanding of the equilibrium and transport properties of PCM materials that can help accelerate technology development. We then emphasize how the microscopic phonon picture of both liquids and solids enables a better understanding of novel PCM systems and their predictive power. Here, we then show how this microscopic picture can be used to understand kinetic processes, such as supercooling, and how it can impact the thermal power output in thermal energy storage systems.

25 ENERGY STORAGE↗

Concrete Thermal Energy Storage Enabling Flexible Operation without Coal Plant Cycling

The work described in this report is responsive to the Office of Fossil Energy program “Energy Storage for Fossil Power Generation.” The pilot plant built as a result of this project demonstrated the feasibility and performance of a concrete thermal energy storage (CTES) system integrated with a supercritical coal power plant. The 10 MWh electrical (>25 MWh thermal) CTES unit, developed by Storworks Power, was designed to enable flexible operation of coal plants without cycling damage. The project's key technical achievements showcase a significant advancement in energy storage technology. A modular CTES system using 42 “Bolderblocs” units was successfully designed and constructed at Alabama Power’s Plant Gaston Unit 5, with each block containing embedded stainless-steel coils in specialized, cost-effective high-temperature concrete. The system interfaced seamlessly with the plant's 3500 psig (241 barg), 1000°F (538°C) supercritical steam, demonstrating operational flexibility. Over 86 full cycles, the CTES exhibited rapid charging and discharging capabilities, effectively mimicking steam turbine feed conditions and handling varying load profiles and storage durations. Performance validation confirmed the system's ability to consistently meet design target steam conditions of 75 bar-a and ~400°C for nominal baseline discharge. The concrete material withstood repeated thermal cycling without degradation, validating earlier lab-scale tests. Integration of balance of plant components, including a condensate management system with storage tank and air-cooled condenser, minimized plant interfaces and water consumption. A robust control scheme ensured safe, automated operation across various scenarios. Key learnings from the project were invaluable: 1. Initial concrete drying and commissioning procedures were refined for future deployments, enhancing efficiency in subsequent installations. 2. System flexibility exceeded expectations, with rapid response to changing conditions. 3. Design improvements were identified including optimized insulation and piping that will enhance overall system efficiency in future deployments 4. Full cycle thermal roundtrip efficiencies exceeded 88%. While the roundtrip electrical efficiency was somewhat limited by known challenges using input steam, such constraints may be mitigated by swapping steam for hot air as thermal input. 5. A summary of key performance parameters for the pilot test and predicted performance of a full scale commercial system with specified improvements determined from the pilot are shown in Section 8. The project faced challenges, including COVID-19 delays and host plant availability constraints. However, these were overcome through adaptive planning and execution. The successful management of these obstacles demonstrated the resilience and adaptability of the project team and the robustness of the CTES technology. This successful pilot demonstrates the potential for CTES to enhance coal plant flexibility, supporting grid stability as renewable penetration increases. The validated design and operational data provide a solid foundation for scaling up to utility-scale implementations, potentially transforming how thermal plants operate in evolving energy landscapes. The system's ability to rapidly respond to changing grid conditions while maintaining high efficiency makes it a promising solution for balancing intermittent renewable energy sources. Furthermore, the project highlighted the potential for even greater efficiencies in future iterations. The use of air as an input medium could potentially eliminate the limitations observed with steam input, opening new possibilities for energy storage applications beyond coal plant integration. In conclusion, this pilot project not only achieved its primary goals but also uncovered additional benefits and potential applications of the CTES technology. It represents a significant step forward in addressing the challenges of grid stability and flexibility in an increasingly renewable-driven energy landscape.

01 COAL, LIGNITE, AND PEAT↗

Impact of molten salt inflow on the temperature distribution in thermal energy storage tanks at startup for central receiver concentrating solar power plants

Concentrating Solar Power (CSP) systems with molten salt thermal energy storage (TES) tanks are one of the most promising, renewable-based energy conversion technologies for larger-scale power generation. The TES tank is one of the most critical components in CSP plants due to its high-temperature operation (up to 565 °C), daily thermal cycling, and intermittent solar radiation conditions. The plant startup is one of the most challenging operation conditions that could lead to damaging thermal gradients due to low salt inventory levels. In this study an analytical model for the sparger ring was developed and integrated with a detailed computational fluid dynamics model of a commercial-scaled molten salt tank. The integrated model allows an accurate representation of the tank operation to evaluate the effect of molten salt inflow on the mixing process. The tank filling process during plant startup was analyzed considering sparger rings with variations in design features, including inlet orifice configurations, number of orifices, direction of the inlets, and orifice diameter. The results demonstrated that higher temperature gradients are obtained in the tank floor during the plant startup. A sparger ring configuration with a predetermined orifice inlet inclination (30°, 45° and 60°) leads to significant temperature differences in the floor, between 57 °C and 62 °C, but better homogeneity in the temperature of the salt inventory. Lower salt inflow velocities result in a more homogeneous floor temperature, with maximum temperature differences under 38 °C. The sparger ring configuration with 52 orifices of 1-in. diameter and vertical flow showed better homogeneity in the temperature differences as a function of the salt level and lower temperature gradients in the tank floor. Because large temperature gradients in the tank's floor have been identified as one of the main factors contributing to tank failures, assessing various sparger ring design features is fundamental to determining proper inflow conditions that lead to low-temperature gradients and reducing failure susceptibility.

14 SOLAR ENERGY↗

One System, Many Models: Designing a Surrogate Model for Sulfur Thermal Energy Storage: Preprint

Industrial process heating (IPH) relies primarily on thermal energy generated by fossil fuel combustion to produce, treat, and alter manufactured goods. Thermal energy storage (TES) helps reduce the carbon footprint of IPH systems by facilitating the utilization of renewable and waste heat sources. A promising new TES technology uses elemental sulfur as the heat-storage medium. The design of sulfur TES systems can be evaluated with the aid of computational fluid dynamics (CFD). However, the computational cost of such CFD efforts is prohibitive to comprehensive optimizations over design parameters. To reduce this computational cost, machine learning (ML) models can be developed to act as surrogates for CFD. In this paper, we describe the process of building and evaluating surrogate ML models for facilitating optimization of sulfur TES systems for IPH. To enforce the thermodynamic relationship between the two modeled quantities, we develop a hybrid model for sulfur temperature using both direct predictions of temperature and calculations of temperature from predictions of the heat transfer coefficient. The hybrid model enforces this constraint at the expense of the slightly reduced accuracy compared to two disjoint models. The overall high accuracy observed in our model evaluation demonstrates the usefulness of such surrogate modeling for studying TES systems. This work contributes to the field of TES surrogate modeling by offering a novel accurate hybrid approach to predicting simultaneously the heat transfer coefficient and temperature of the heat storage medium.

computational fluid dynamics↗

Influence of Diffuse and Ground-Reflected Irradiance on the Spectral Modeling of Solar Reference Cells

Thermal Energy Storage (TES) is a key component for solar thermal applications to bridge the gap between the demand for thermal energy and the supply of solar energy, whose availability depends on the time of day and season. Thus, cost-effective packed-bed thermal containers filled with a solid storage medium have been proposed for high-temperature sensible heat storage as materials are abundant and relatively cheap. Thus, it is necessary to investigate their performance and temperature profiles during the charge-discharge cycle. Several models are available for this purpose. Typically, the more detailed a model, the greater the computational effort required to solve it, and hence a time-efficient model is needed to prevent excessively long computation times for long-term analysis. At the more basic level, the common Hughes E-NTU model and the less realistic simplified Infinite-NTU model are very important for their less time and computational effort. In this paper, the appropriateness of employing the Infinite-NTU model was evaluated to investigate the performance of a typical and scalable rock-bed TES as a case study. The results presented provide a methodology to quickly test the validity of the model and predict the temperature profile for the case under study. Accordingly, such simple charge-discharge cycle thermal performance predictions are important to plan, design, and rapidly deploy a reliable and economical solar thermal system for the supply of valuable heat to high-temperature demanding applications of power generation and industrial processes as part of a rapid shift towards non-polluting renewable energy. Keywords: Solar Thermal, TES, Packed-bed, NTU model, Temperature profile

PV modeling↗

Using concentrating-solar-power plants as economic carbon-free capacity resources

Deep decarbonization of electricity systems raises concerns about the need for generating capacity that can maintain reliable energy supply. Given this concern, we explore the ability of concentrating-solar-power plants with thermal energy storage to provide a carbon-free source of such capacity. We develop an approach to assessing the capacity contribution of concentrating-solar-power plants that considers future systems. Such considerations are important, because of potential differences in net-load patterns compared to today (e.g., due to higher renewable-energy penetrations). Using historical data spanning an 18-year period, we demonstrate that concentrating-solar-power plants with thermal energy storage can provide this necessary capacity with little impact on their financial viability. We examine the impact of myopic decisions and imperfect foresight of future system conditions on the operation of concentrating-solar-power plants and the resultant impact on their capacity contributions. We find that imperfect foresight can have limited impacts on such a use of concentrating-solar-power plants, so long as proper forecasting techniques are developed and used. Overall, our work shows that concentrating-solar-power plants with thermal energy storage may have a role to play in delivering reliable electricity supply in a decarbonized energy system.

14 SOLAR ENERGY↗

The Best of Both Worlds: Combined Thermal and Battery Storage for Widespread Building Decarbonization

To meet 2050 decarbonization targets, widespread building electrification is a critical complement to clean power generation. Behind-the-meter storage (BTMS) (e.g., battery electric energy storage [EES] and thermal energy storage [TES]) integrated with buildings or building end uses to store and supply energy at optimal times can minimize burdens associated with operation, planning, and upgrades to the electrical grid sometimes triggered by building electrification. Such BTMS systems can serve the dual purpose of providing enhanced resilience at the building and grid level, and support the deployment of renewable generation needed for wide-scale decarbonization. While TES can cost-effectively shed and shift thermal loads, it cannot generally backup or shift non-thermal building end uses. EES, by contrast, is more expensive, but applicable to all end uses (i.e., thermal and electrical loads). Combined together, these storage systems can be traded off against one another to perform optimally in meeting demand flexibility, decarbonization goals, and energy resilience of the buildings at a lower total system cost. This paper proposes a framework to define BTMS benefits, provides four illustrative electrification scenarios using TES and EES, and discusses the combined TES/EES benefits with building energy modeling results. The paper also highlights potential barriers to adoption of BTMS and a path forward.

buildings↗

Synergistic Heat Pumped Thermal Storage and Flexibly Carbon Capture System

As the U.S. grid evolves toward a lower-carbon system, fossil generation assets need to operate in energy markets with high variable renewable energy (VRE) penetration while also decreasing carbon emissions. Current carbon capture and storage (CCS) technologies suffer from high capital cost and an inability to operate flexibly during periods of oscillating demand. The ARPA-E FLECCS Program Phase 1 was created to fund designing and optimizing innovative CCS processes that enable flexibility on a high-VRE grid. To address this need, the Colorado State University (CSU) Team won funding to design a synergized system of thermal energy storage, power generation, and flexible carbon capture to enable breakthrough system performance that achieves an LCOE <$75/MWh with >99% capture rate. This approach will target new or existing natural gas combined cycle power plants. The proposed design utilizes novel hot and cold thermal energy storage (TES) technologies that store low-cost, off-peak electricity as thermal energy to power CCS solvent regeneration and boost plant output during periods of peak demand. The design provides an overall optimized net present value (NPV) by maximizing low carbon power to grid while prices are highest using Storworks Power’s concrete TES technology. The team also capitalizes on decades of ION Clean Energy’s (ION) development in low cost and flexible pioneering solvent technology, which has proven reductions in energy consumption and overall cost of 28% and 38%, respectively, compared with state-of-the-art CCS.

20 FOSSIL-FUELED POWER PLANTS↗

Integration of Heat Pumps With Solar Thermal Systems for Energy Storage

This chapter considers the combination of solar thermal systems with an energy storage device known as a Carnot Battery which charges thermal storage with a heat pump or electric heater. Integrating these systems can provide a variety of advantages, such as dispatchable renewable power generation and electricity storage services. In this chapter a variety of methods for hybridizing these systems are described, and ideal cycle analysis is used to assess their relative merits.

Carnot Battery↗