Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAFIR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Indium Hybridization of Large Format TES Bolometer Arrays to Readout Multiplexers for Far-Infrared Astronomy

The advance of new detector technologies combined with enhanced fabrication methods has resulted in an increase in development of large format arrays. The next generation of scientific instruments will utilize detectors containing hundreds to thousands of elements providing a more efficient means to conduct large area sky surveys. Some notable detectors include a 32x32 x-ray microcalorimeter for Constellation-X, an infrared bolometer called SAFIRE to fly on the airborne observatory SOFIA, and the sub-millimeter bolometer SCUBA-2 to be deployed at the JCMT which will use more than 10,000 elements for two colors, each color using four 32x40 arrays. Of these detectors, SCUBA-2 is farthest along in development and uses indium hybridization to multiplexers for readout of the large number of elements, a technology that will be required to enable the next generation of large format arrays. Our current efforts in working toward large format arrays have produced GISMO, the Goddard IRAM Superconducting 2-Millimeter observer. GISMO is a far infrared instrument to be field tested later this year at the IRAM 30 meter telescope in Spain. GISMO utilizes transition edge sensor (TES) technology in an 8x16 filled array format that allows for typical fan-out wiring and wire-bonding to four 1x32 NIST multiplexers. GISMO'S electrical wiring is routed along the tops of 30 micron walls which also serve as the mechanical framework for the array. This architecture works well for the 128 element array, but is approaching the limit for routing the necessary wires along the surface while maintaining a high fill factor. Larger format arrays will benefit greatly from making electrical connections through the wafer to the backside, where they can be hybridized to a read-out substrate tailored to handling the wiring scheme. The next generation array we are developing is a 32x40 element array on a pitch of 1135 microns that conforms to the NIST multiplexer, already developed for the SCUBA-2 instrument This architecture will utilize electrical connections that route from the TES to the support frame and through the wafer. The detector chip will then be hybridized to the NIST multiplexer via indium bump bonding. In our development scheme we are using substrates that allow for diagnostic testing of electrical continuity across the entire array and we are testing our process to minimize or eliminate any contact resistance at metal interfaces. Our goal is hybridizing a fully functional 32x40 array of TES bolometers to a NIST multiplexer. The following work presents our current progress toward enabling this technology.

Miller, Timothy M.↗

Lightweight Magnetic Cooler With a Reversible Circulator

A design of a highly efficient and lightweight space magnetic cooler has been developed that can continuously provide remote/distributed cooling at temperatures in the range of 2 K with a heat sink at about 15 K. The innovative design uses a cryogenic circulator that enables the cooler to operate at a high cycle frequency to achieve a large cooling capacity. The ability to provide remote/distributed cooling not only allows flexible integration with a payload and spacecraft, but also reduces the mass of the magnetic shields needed. The active magnetic regenerative refrigerator (AMRR) system is shown in the figure. This design mainly consists of two identical magnetic regenerators surrounded by their superconducting magnets and a reversible circulator. Each regenerator also has a heat exchanger at its warm end to reject the magnetization heat to the heat sink, and the two regenerators share a cold-end heat exchanger to absorb heat from a cooling target. The circulator controls the flow direction, which cycles in concert with the magnetic fields, to facilitate heat transfer. Helium enters the hot end of the demagnetized column, is cooled by the refrigerant, and passes into the cold-end heat exchanger to absorb heat. The helium then enters the cold end of the magnetized column, absorbing heat from the refrigerant, and enters the hot-end heat exchanger to reject the magnetization heat. The efficient heat transfer in the AMRR allows the system to operate at a relatively short cycle period to achieve a large cooling power. The key mechanical components in the magnetic cooler are the reversible circulator and the magnetic regenerators. The circulator uses non-contacting, self-acting gas bearings and clearance seals to achieve long life and vibration- free operation. There are no valves or mechanical wear in this circulator, so the reliability is predicted to be very high. The magnetic regenerator employs a structured bed configuration. The core consists of a stack of thin GGG disks alternating with thin polymer insulating films. The structured bed reduces flow resistance in the regenerator and therefore the pumping work by the cryogenic circulator. This magnetic cooler will enable cryogenic detectors for sensing infrared, x-ray, gamma-ray, and submillimeter radiation in future science satellites, as well as the detector systems in the Constellation-X (Con-X) and the Single Aperture Far-Infrared observatory (SAFIR). Scientific ap p - lica tions for this innovation include cooling for x-ray micro calorimeter spectrometers used for microanalysis, cryogenic particle detectors, and superconducting tunnel junction de tectors for biomolecule mass spectrometry. The cooler can be scaled to provide very large cooling capacities at very low temperatures, ideal for liquid helium and liquid hydrogen productions.

Chen, Weibo↗

Electrical NEP in Hot-Electron Titanium Superconducting Bolometers

We are presenting the current progress on the titanium (Ti) hot-electron transition-edge devices. The ultimate goal of this work is to develop a submillimeter Hot-Electron Direct Detector (HEDD) with the noise equivalent power NEP = 10(sup -1) - 10(sup -20) W/Hz(sup 1/2) for the moderate resolution spectroscopy and Cosmic Microwave Background (CMB) studies on future space telescope (e.g., SPICA, SAFIR, SPECS, CMBPol) with cryogenically cooled (approximately 4-5 K) mirrors. Recently, we have achieved the extremely low thermal conductance (approximately 20 fW/K at 300 mK and approximately 0.1 fW/K at 40 mK) due to the electron-phonon decoupling in Ti nanodevices with niobium (Nb) Andreev contacts. This thermal conductance translates into the "phonon-noise" NEP approximately equal to 3 x 10(sup -21) W/Hz(sup 1/2) at 40 mK and NEP approximately equal to 3 x 10(sup -19) W/Hz(sup 1/2) at 300 mK. These record data indicate the great potential of the hot-electron detector for meeting many application needs. Beside the extremely low phonon-noise NEP, the nanobolometers have a very low electron heat capacitance that makes them promising as detectors of single THz photons. As the next step towards the practical demonstration of the HEDD, we fabricated and tested somewhat larger than in Ref.1 devices (approximately 6 micrometers x 0.35 micrometers x 40 nm) whose critical temperature is well reproduced in the range 300-350 mK. The output electrical noise measured in these devices with a low-noise dc SQUID is dominated by the thermal energy fluctuations (ETF) aka "phonon noise". This indicates the high electrothermal loop gain that effectively suppresses the contributions of the Johnson noise and the amplifier (SQUID) noise. The electrical NEP = 6.7 x 10(sup -18) W/Hz(sup 1/2) derived from these measurements is in good agreement with the predictions based on the thermal conductance data. The very low NEP and the high speed (approximately microns) are a unique combination not found in other detectors.

transition-edge sensor↗

Evaluation of a High-Resolution Numerical Weather Prediction Model’s Simulated Clouds Using Observations from CloudSat, GOES-13 and in Situ Aircraft

This study aimed to assess tropical cloud properties predicted by Environment and Climate Change Canada’s Global Environmental Multiscale (GEM)modelwhen run with the Milbrandt–Yau double-moment cloud microphysical scheme and one-way nesting that culminated at a (∼300 km)2 inner domain with 0.25 km horizontal grid spacing. The assessment utilized satellite and in situ data collected during the High Ice Water Content (HIWC) and High Altitude Ice Crystals (HAIC) projects for a mesoscale convective system on 16May 2015 over French Guiana.Data fromCloud- Sat’s cloud-profiling radar and GOES-13’s imager were compared to data either simulated directly by GEM or produced by operating on GEM’s cloud data with both the CFMIP (Cloud Feedback Model Intercomparison Project) Observation Simulator Package (COSP) instrument simulator and a three-dimensional Monte Carlo solar radiative transfer model. In situ observations were made from research aircraft – Canada’s National Research Council Convair-580 and the French SAFIRE Falcon-20 – whose flight paths were aligned with CloudSat’s ground-track. Spatial and temporal shifts of clouds simulated by GEM compared well to GOES-13 imagery. There are, however, differences between simulated and observed amounts of high and low cloud. While GEM did well at predicting ranges of ice-water content (IWC) near 11 km altitude (Falcon-20), it produces too much graupel and snow near 7 km (Convair-580). This produced large differences between CloudSat’s and COSP-generated radar reflectivities and two-way attenuations. On the other hand, CloudSat’s inferred values of IWC agree well with in situ samples at both altitudes. Generally, GEM’s visible reflectances exceeded GOES-13’s on account of having produced too much low-level liquid cloud. It is expected that GEM’s disproportioning of cloud hydrometeors will improve once it includes a better representation of secondary ice production.

Qu, Zhipeng↗

Residential HVAC Fault Data Collection Plan – Refrigerant Undercharge and Overcharge Faults

Heating, ventilation, and air-conditioning (HVAC) systems can develop faults due to poor installation practices or gradual wear and tear, leading to decreased HVAC system’s efficiency, compromised thermal comfort, and shortened equipment lifespan (EERE, 2018). Automated fault detection and diagnosis (AFDD) technologies offer a solution by identifying energy-wasting HVAC faults, such as inadequate indoor airflow and incorrect refrigerant charge, and guiding technicians to enhance system efficiency. In the realm of residential HVAC, AFDD can be implemented through various fault detection and diagnosis capabilities, sensor configurations, and target applications. These technologies typically fall into three categories: smart diagnostic tools, original equipment manufacturer (OEM)-embedded tools, and add-on tools. Smart diagnostic tools employ temporarily installed sensors to directly measure HVAC system characteristics, while OEM-embedded tools utilize factory-installed sensors to identify faults or assess system performance. However, both these types of AFDD technologies are often only accessible for high-end HVAC equipment or require additional sensor installation by qualified technicians, resulting in high investment costs and limited applicability for low-income residential buildings. On the other hand, add-on tools rely solely on data from smart thermostats and meters to detect faults by continuously analyzing equipment runtime or energy usage. As smart thermostat and meter costs decrease and their prevalence increases, these tools can be readily deployed in low-income residential buildings. However, they possess limited capabilities as they rely solely on basic trend analysis. Enhancing such tools with advanced machine learning algorithms can significantly improve their effectiveness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydronic Shell: An Affordable Solution for Multifamily Deep Energy Retrofit

Approximately 42% of multi-family buildings in the United States have do not have insulation as required by the building codes. Envelope retrofits of these buildings are needed to improve their thermal performance, provide thermal resilience, and enable a pathway to electrification of space heating systems. Hydronic shell (HS) is a retrofit technique where a stud wall layer is added to a masonry wall along with a convective coil and a fan coil unit fitted in the façade cavity which can provide both heating and cooling to the space. The HS system serves a dual purpose of 1) retrofitting the building envelope and 2) retrofitting the HVAC system and enabling electrification of space heating. The electrification of space heating is possible from the installation of a combination of hydronic system/fan coil unit system which uses a central heat pump as a source of heating water in the cavity between the existing wall and retrofit insulation layer. This study evaluates the performance of the HS system at varying outdoor conditions mimicked by a climate chamber and hot water supply temperature from a water bath. During the ramp-up period, the indoor chamber temperature could be increased from 66 ºF to 69.5 ºF within an hour using heating water at 120 ºF when the outdoor chamber temperature was at 0 ºF. When the indoor chamber temperature was maintained within a deadband, variation in cavity air temperature was mostly influenced by the duration when water was flowing through the cavity convector. It was seen from the testing that the hydronic system alone without use of fan in the system is able to maintain the space temperature at coldest outdoor condition used in the experiment (0 ºF) even at lowest hot water supply temperature chosen (90 ºF). During the ramp-down period, the fastest decline in temperature took 6.4 hours from temperature to drop from 69.6 ºF to 66 ºF which shows tremendous potential of thermal resilience and peak load shifting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying and Optimizing the Energy Benefits of Mass Timber Construction

The International Mass Timber Alliance (IMTA) is a global organization of industry leaders, engineers, scientists, and associations dedicated to advancing mass timber construction. Its mission is to generate and disseminate scientific data supporting the development of standardized construction and energy efficient practices that promote the adoption of mass timber worldwide. IMTA collaborated with Oak Ridge National Laboratory (ORNL) to leverage ORNL’s expertise in building envelope modeling and testing to evaluate how mass timber construction can reduce peak heating and cooling demand, lower overall energy use, and improve resilience during power outages. A previous study of 80 mass timber buildings in Finland found measured energy use up to 50% lower than predicted by simulation. This project aimed to validate and extend those findings for U.S. buildings through analytical modeling, laboratory testing, and full-scale building evaluations. The research focused on the thermal performance of low-embodied-energy wall assemblies, such as cross-laminated timber (CLT) panels and log walls, with particular attention to the effects of thermal inertia on indoor comfort and energy performance. While mass timber’s structural and fire-resistance properties are well documented, its whole-building thermal behavior has received limited attention. Field data, simulation results, and resilience testing from this study will inform future modeling practices, design guidelines, and construction practices by quantifying the unique thermal and demand-flexibility benefits of mass timber construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prediction of directional reflectance of a corn field under stress

A vegetative canopy model concept is developed and used to calculate the directional spectral reflectance of a corn field under stress. The problem has been idealized by assuming that the canopy is represented in several layers of uniform but randomly distributed biological components; horizontal and vertical projection of leaves, for example, replaces the actual leaf. An accumulative horizontal projection leads to a quantitative horizontal leaf area index while accumulated vertical projections provide the vertical leaf index area for each layer. The spectral properties of the projections are obtained from the spectral properties of the biological components. These techniques together with soil reflectance data provide a physical description for the vegetative canopy and adequately interprete multispectral scanning data.

Suits, G. H.↗

Application of ERTS-1 data to analysis of agricultural crops and forests in Michigan

The results reported are based on analysis of ERTS Frame 1033-15580 collected over southwestern Lower Michigan on August 25, 1972. Major agricultural crops such as corn and soybeans were approaching maturity at this data and forest canopies were dense. Extensive ground truth information was gathered by detailed field study of test strips. This detailed information was supplemented over larger areas by interpretation of RB-57 and C-47 photography and MSS imagery. Recognition processing of ERTS-1 MSS data was carried out on a digital computer. Fields and forest stands were selected as training sets and test areas. Aerial imagery was essential for locating the positions of these selected areas on ERTS digital tapes. The recognition process was successful for each type of vegetation which had a dense green canopy such as forests, corn, and soybeans. Bare soil was also recognizable as a category.

Safir, G. R.↗

Use of ERTS data for a multidisciplinary analysis of Michigan resources

The author has identified the following significant results. The results of this investigation of ratioing simulated ERTS spectral bands and several non-ERTS bands (all collected by an airborne multispectral scanner) indicate that significant terrain information is available from band-ratio images. Ratio images, which are based on the relative spectral changes which occur from one band to another, are useful for enhancing differences and aiding the image interpreter in identifying and mapping the distribution of such terrain elements as seedling crops, all bare soil, organic soil, mineral soil, forest and woodlots, and marsh areas. In addition, the ratio technique may be useful for computer processing to obtain recognition images of large areas at lower costs than with statistical decision rules. The results of this study of ratio processing of aircraft MSS data will be useful for future processing and evaluation of ERTS-1 data for soil and landform studies. Additionally, the results of ratioing spectral bands other than those currently collected by ERTS-1 suggests that some other bands (particularly a thermal band) would be useful in future satellites.

Andersen, A. L.↗

Economic evaluation of crop acreage estimation by multispectral remote sensing

The author has identified the following significant results. Photointerpretation of S190A and S190B imagery showed significantly better resolution with the S190B system. A small tendancy to underestimate acreage was observed. This averaged 6 percent and varied with field size. The S190B system had adequate resolution for acreage measurement but the color film did not provide adequate contrast to allow detailed classification of ground cover from imagery of a single date. In total 78 percent of the fields were correctly classified but with 56 percent correct for the major crop, corn.

Manderscheid, L. V.↗

Estimation of old field ecosystem biomass using low altitude imagery

Color-infrared photography was used to evaluate the biomass of experimental plots in an old-field ecosystem that was treated with different levels of waste water from a sewage treatment facility. Cibachrome prints at a scale of approximately 1:1,600 produced from 35 mm color infrared slides were used to analyze density patterns using prepared tonal density scales and multicell grids registered to ground panels shown on the photograph. Correlation analyses between tonal density and vegetation biomass obtained from ground samples and harvests were carried out. Correlations between mean tonal density and harvest biomass data gave consistently high coefficients ranging from 0.530 to 0.896 at the 0.001 significance level. Corresponding multiple regression analysis resulted in higher correlation coefficients. The results of this study indicate that aerial infrared photography can be used to estimate standing crop biomass on waste water irrigated old field ecosystems. Combined with minimal ground truth data, this technique could enable managers of wastewater irrigation projects to precisely time harvest of such systems for maximal removal of nutrients in harvested biomass.

Nor, S. M.↗