At least 109 records · Page 6

EVALUATION OF ALTERNATIVE FILTER MEDIA FOR THE ROTARY MICROFILTER

SRS is currently developing and testing several processes to treat high level radioactive liquid waste. These processes include the Integrated Salt Disposition Process (ISDP), the Salt Waste Processing Facility (SWPF), and the Small Column Ion Exchange Process (SCIX). Each of these processes has a solid-liquid separation process that limits its throughput. SRNL researchers identified and tested the rotary microfilter as a technology to increase solid-liquid separation throughput. The testing showed significant improvement in filter flux with the rotary microfilter over the baseline crossflow filter (i.e., 2.5-6.5X during scoping tests, as much as 10X in actual waste tests, and approximately 3X in pilot-scale tests). SRNL received funding from DOE EM-21, and subsequently DOE EM-31 to develop the rotary microfilter for high level radioactive service. The work has included upgrading the rotary microfilter for radioactive service, testing with simulated SRS waste streams, and testing it with simulated Hanford waste streams. While the filtration rate is better than that obtained during testing of crossflow filters, the authors believe the rotary microfilter throughput can be improved by using a better filter membrane. The rotary microfilter membrane is made of stainless steel (Pall PMM050). Previous testing, funded by DOE EM-21, showed that asymmetric filters composed of a ceramic membrane on top of a stainless steel support produced higher filter flux than 100% stainless steel symmetric filters in crossflow filter tests. In that testing, the Pall Accusep and Graver filters produced 13-21% larger filter flux than the baseline 0.1 {micro}m Mott filter. While the improvement in flux is not as dramatic as the improvement of the rotary filter over a crossflow filter, a 13-21% increase could reduce the lifetime of a 30 year process by 4-6 years, with significant cost savings. Subsequent rotary filter testing showed the Pall PMM050 stainless steel filter membrane produced higher flux than the Mott filter media in bench-scale and pilot-scale testing. The Accusep and Graver filter media were not evaluated in that testing, because they are not available as flat sheets. The Accusep filter was developed at ORNL and licensed to Pall Corporation. This filter has a stainless steel support structure with a zirconium oxide ceramic membrane. The pore size is 0.1 {micro}m absolute. The Graver filter has a stainless steel support structure with a titanium dioxide ceramic membrane. The pore size is 0.07 {micro}m absolute. SRNL and ORNL are working together to develop filter media similar to the Accusep and Graver media, and to test them in a bench-scale filtration apparatus to attempt to improve the throughput of the rotary microfilter. This report describes the effort.

36 MATERIALS SCIENCE↗

LITERATURE REVIEW OF BORIC ACID SOLUBILITY DATA

A new solvent system is being evaluated for use in the Modular Caustic-Side Solvent Extraction Unit (MCU) and in the Salt Waste Processing Facility (SWPF). The new system replaces the current dilute nitric acid strip solution with 0.01 M boric acid. This literature study is performed to determine if there is a potential for boric acid to crystallize in the lines with emphasis on the transfer lines to the Defense Waste Processing Facility. This report focuses on the aqueous phase chemistry of boric acid under conditions relevant to MCU and SWPF. Operating and transfer conditions examined for the purpose of this review include temperatures between 13 C (McLeskey, 2008) and 45 C (Fondeur, 2007) and concentrations from 0 to 3M in nitric acid as well as exposure of small amounts of entrained boric acid in the organic phase to the sodium hydroxide caustic wash stream. Experiments were also conducted to observe any chemical reactions and off-gas generation that could occur when 0.01 M boric acid solution mixes with 3 M nitric acid solution and vice versa. Based on the low concentration (0.01M) of boric acid in the MCU/SWPF strip acid and the moderate operating temperatures (13 C to 45 C), it is unlikely that crystallization of boric acid will occur in the acid strip solution under process or transfer conditions. Mixing experiments of boric and nitric acid show no measurable gas generation (< 1 cc of gas per liter of solution) under similar process conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Next Generation Solvent Development for Caustic-Side Solvent Extraction of Cesium

This report summarizes the FY 2010 and 2011 accomplishments at Oak Ridge National Laboratory (ORNL) in developing the Next Generation Caustic-Side Solvent Extraction (NG-CSSX) process, referred to commonly as the Next Generation Solvent (NGS), under funding from the U.S. Department of Energy, Office of Environmental Management (DOE-EM), Office of Technology Innovation and Development. The primary product of this effort is a process solvent and preliminary flowsheet capable of meeting a target decontamination factor (DF) of 40,000 for worst-case Savannah River Site (SRS) waste with a concentration factor of 15 or higher in the 18-stage equipment configuration of the SRS Modular Caustic-Side Solvent Extraction Unit (MCU). In addition, the NG-CSSX process may be readily adapted for use in the SRS Salt Waste Processing Facility (SWPF) or in supplemental tank-waste treatment at Hanford upon appropriate solvent or flowsheet modifications. Efforts in FY 2010 focused on developing a solvent composition and process flowsheet for MCU implementation. In FY 2011 accomplishments at ORNL involved a wide array of chemical-development activities and testing up through single-stage hydraulic and mass-transfer tests in 5-cm centrifugal contactors. Under subcontract from ORNL, Argonne National Laboratory (ANL) designed a preliminary flowsheet using ORNL cesium distribution data, and Tennessee Technological University confirmed a chemical model for cesium distribution ratios (DCs) as a function of feed composition. Inter laboratory efforts were coordinated with complementary engineering tests carried out (and reported separately) by personnel at Savannah River National Laboratory (SRNL) and Savannah River Remediation (SRR) with helpful advice by Parsons Engineering and General Atomics on aspects of possible SWPF implementation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SME Acceptability Determination For DWPF Process Control (U)

The statistical system described in this document is called the Product Composition Control System (PCCS). K. G. Brown and R. L. Postles were the originators and developers of this system as well as the authors of the first three versions of this technical basis document for PCCS. PCCS has guided acceptability decisions for the processing at the Defense Waste Processing Facility (DWPF) at the Savannah River Site (SRS) since the start of radioactive operations in 1996. The author of this revision to the document gratefully acknowledges the firm technical foundation that Brown and Postles established to support the ongoing successful operation at the DWPF. Their integration of the glass propertycomposition models, developed under the direction of C. M. Jantzen, into a coherent and robust control system, has served the DWPF well over the last 20+ years, even as new challenges, such as the introduction into the DWPF flowsheet of auxiliary streams from the Actinide Removal Process (ARP) and other processes, were met. The purpose of this revision is to provide a technical basis for modifications to PCCS required to support the introduction of waste streams from the Salt Waste Processing Facility (SWPF) into the DWPF flowsheet. An expanded glass composition region is anticipated by the introduction of waste streams from SWPF, and property-composition studies of that glass region have been conducted. Jantzen, once again, directed the development of glass property-composition models applicable for this expanded composition region. The author gratefully acknowledges the technical contributions of C.M. Jantzen leading to the development of these glass property-composition models. The integration of these models into the PCCS constraints necessary to administer future acceptability decisions for the processing at DWPF is provided by this sixth revision of this document.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation Of Chemical Additives For Glycolate Destruction In The Recycle Collection Tank

Savannah River National Laboratory (SRNL) has completed a work scope in support of the Savannah River Remediation (SRR) Nitric-Glycolic flowsheet. Glycolic acid will replace formic acid as a reducing agent in the pre-processing of High-Level Waste sludge performed at the Defense Waste Processing Facility (DWPF). Glycolic acid will perform the same function as formic acid, namely reduction of mercury and adjustment of feed rheology and melter oxidation/reduction potential, while significantly reducing the potential for hydrogen generation in DWPF processing. Development testing has demonstrated glycolic acid virtually eliminates hydrogen production in the pre-processing steps. The Nitric-Glycolic flowsheet significantly improves DWPF’s ability to address Savannah River Site’s key challenge - the incorporation of effluent received from the Salt Waste Processing Facility (SWPF). SWPF will deliver significant effluent volume to DWPF, resulting in a concurrent increase in DWPF effluent returned to the Concentration, Storage and Transfer Facilities (CSTF). This work scope demonstrates that glycolate can be destroyed under the Nitric-Glycolic flowsheet prior to returning the DWPF recycle stream to CSTF. To avoid potential flammability issues due to thermolysis of glycolate in CSTF, SRR tasked SRNL to quantify and mitigate glycolate returns via DWPF recycle stream. The development of a strategy for glycolic mitigation initiated with a system’s engineering workshop. Various chemical and/or physical solutions for how to and where to destroy glycolate were considered – consistent with DWPF operational capabilities and process requirements. The workshop identified chemical oxidation of glycolate within the DWPF Recycle Collection Tank (RCT)a as the most promising option with sodium permanganate and Fenton’s reagent (metallic ion catalyzed hydrogen peroxide) as the two most promising oxidants.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of chemical additives for glycolic destruction in the recycle collection tank

Savannah River National Laboratory (SRNL) has completed a work scope in support of the Savannah River Remediation (SRR) Nitric-Glycolic flowsheet. Glycolic acid will replace formic acid as a reducing agent in the pre-processing of High-Level Waste sludge performed at the Defense Waste Processing Facility (DWPF). Glycolic acid will perform the same function as formic acid, namely reduction of mercury and adjustment of feed rheology and melter oxidation/reduction potential, while significantly reducing the potential for hydrogen generation in DWPF processing. Development testing has demonstrated glycolic acid virtually eliminates hydrogen production in the pre-processing steps. The Nitric-Glycolic flowsheet significantly improves DWPF’s ability to address Savannah River Site’s key challenge - the incorporation of effluent received from the Salt Waste Processing Facility (SWPF). SWPF will deliver significant effluent volume to DWPF, resulting in a concurrent increase in DWPF effluent returned to the Concentration, Storage and Transfer Facilities (CSTF). This work scope demonstrates that glycolate can be destroyed under the Nitric-Glycolic flowsheet prior to returning the DWPF recycle stream to CSTF. To avoid potential flammability issues due to thermolysis of glycolate in CSTF, SRR tasked SRNL to quantify and mitigate glycolate returns via DWPF’s recycle stream. The development of a strategy for glycolic mitigation was initiated with a system’s engineering workshop. Various chemical and/or physical solutions for how and where to destroy glycolate were considered – consistent with DWPF’s operational capabilities and process requirements. The workshop identified chemical oxidation of glycolate within the DWPF Recycle Collection Tank (RCT) a as the most promising option with sodium permanganate and Fenton’s reagent (metallic ion catalyzed hydrogen peroxide) as the two most promising oxidants.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Frit 625 Manufacturability Study

Based on the anticipated higher sodium concentration salt stream coming to the Defense Waste Processing Facility (DWPF) from the Salt Waste Processing Facility (SWPF), there may be a future need to reduce the alkali concentration in the frit depending on the composition of the sludge in Tank 40. SWPF is projected to start operating in late 2019. Thus, a lower alkali frit is beneficial for Sludge Batch (SB9) processing. Lower alkali frits may also be needed for Sludge Batch 10 (SB10) and later batches to ensure that the composition of the material in the Slurry Mix Evaporator (SME) is acceptable relative to the Product Composition Control System (PCCS) models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Selection of Glasses in Support of the Sludge Batch 9 Sulfate Solubility Limit for Coupled Operation with the Salt Waste Processing Facility

For Sludge Batches 3 through 8, the sulfate (SO 4 2- )solubility limit for the Defense Waste Processing Facility (DWPF) has been determined by laboratory-scale crucible testing. In preparation for Sludge Batch 9 (SB9) processing, a comparison demonstrated that minor compositional differences existed between the Sludge Batch 8 (SB8)-Frit 803 and SB9-Frit 803 glass composition regions for sludge-only and coupled operations with the Actinide Removal Process (ARP) and Modular Caustic Side Solvent Extraction Unit (MCU). Thus, no experimental testing was necessary and the SB8 SO 4 2- limit of 0.65 wt.% was recommended for SB9 processing. This previous SB9 assessment did not address coupled processing with streams from the Salt Waste Processing Facility (SWPF), which is anticipated to start operations in November 2019. These high activity streams will include monosodium titanate (MST) and sludge solids from the Sludge Solids Receipt Tank (SSRT) as well as Cs-containing strip effluent (SE). The incorporation of these SWPF streams is expected to reach TiO 2 concentrations in glass greater than 2 wt.% based on single and double MST strike scenarios. In support of coupled operation with SWPF, the DWPF Product Composition Control System was revised and allows a TiO 2 concentration of up to 6 wt.% (minus measurement uncertainty) in glass. For the SB8-Frit 803 SO 4 2- solubility study, the maximum TiO 2 concentration evaluated was 0.94 wt.%. Since the influence of increased TiO 2 on the retention of SO 4 2- in the SB9 glass region is unknown, a test matrix of ten glass compositions has been proposed to determine whether the 0.65 wt.% SO 4 2- limit is still appropriate for SB9 coupled operation with SWPF. This report documents the development of a test matrix that will support this study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Permanganate Oxidation of Defense Waste Processing Facility (DWPF) Recycle Collection Tank (RCT) Simulants – Protocol Runs for Nominal and Chemical Process Cell (CPC) Foamover Conditions

Savannah River National Laboratory (SRNL) has completed a work scope in support of the Savannah River Remediation (SRR) Nitric-Glycolic flowsheet. Glycolic acid will replace formic acid as a reducing agent in the pre-processing of High-Level Waste sludge performed at the Defense Waste Processing Facility (DWPF). Glycolic acid will perform the same function as formic acid, namely reduction of mercury and adjustment of feed rheology and melter oxidation/reduction potential, while significantly reducing the potential for hydrogen generation in DWPF processing. Development testing has demonstrated glycolic acid virtually eliminates hydrogen production in the pre-processing steps. The Nitric-Glycolic flowsheet significantly improves DWPF’s ability to address one of the Savannah River Site’s key challenges - the incorporation of effluent received from the Salt Waste Processing Facility (SWPF). SWPF will deliver significant effluent volume to DWPF, resulting in a concurrent increase in DWPF effluent returned to the Concentration, Storage and Transfer Facilities (CSTF). This work scope demonstrates that glycolate can be destroyed under the Nitric-Glycolic flowsheet prior to returning the DWPF recycle stream to CSTF. To avoid potential flammability issues due to thermolysis of glycolate in CSTF, SRR tasked SRNL to quantify and mitigate glycolate returns via DWPF’s recycle stream. The development of a strategy for glycolic mitigation was initiated with a system’s engineering workshop. Various chemical and/or physical solutions for how and where to destroy glycolate were considered – consistent with DWPF’s operational capabilities and process requirements. The workshop identified chemical oxidation of glycolate within the DWPF Recycle Collection Tank (RCT) as the most promising option. (The RCT collects offgas condensate from pre-processing, vitrification, and other unit operations performed in DWPF and is the singular return vessel delivering recycle effluent back to CSTF.) A series of down-select experimental tests were performed that showed sodium permanganate was the most effective oxidant. This work was performed to identify an appropriate operational protocol for DWPF implementation. Building upon the downselect experiments, the work targeted an improved description of suitable RCT conditions prior to the strike (pH, etc.), permanganate addition rate, and destruction reaction kinetics. Data collected were also used to determine the best expression of reaction stoichiometry and the effective minimum permanganate addition required.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of the Supplementary Analyses of Salt Batch 10 and 11 Samples

Supplementary analyses of material from the Interim Salt Disposition Project (ISDP) Salt Batch (SB) 10 and Salt Batch 11 (SB11) samples were analyzed beyond what is described in previous reports. These additional analyses are required to verify these materials meet Salt Waste Processing Facility (SWPF) Waste Acceptance Criteria (WAC) feed requirements. The stored SB10 and SB11 samples have been analyzed without filtering and the results found to be very similar to the previous filtered analyses performed for SB10 and SB11. The only result of significant difference is the wt% insoluble solids result for the SB11 sample. It would appear the newer method of analyzing larger volumes gives more accurate measurements for solutions with low quantities of solids.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analytical Results from Salt Batch 10 Routine DSSHT and SEHT Monthly Samples

Strip Effluent (SE) Hold Tank (SEHT) and Decontaminated Salt Solution (DSS) Hold Tank (DSSHT) samples from several “microbatches” of the Integrated Salt Disposition Project (ISDP) “macrobatch” Salt Batch 10 have been analyzed for 238 Pu, 90 Sr, 137 Cs, cations (via Inductively Coupled Plasma Emission Spectroscopy - ICPES), and in some cases anions (via Ion Chromatography Anions - IC-A). The analytical results from the current microbatch samples are similar to those from previous macrobatches. In the Modular Caustic-Side Solvent Extraction Unit (MCU), the Cs removal continues to exceed process requirements. The bulk chemistry of the DSSHT and SEHT samples do not show any signs of unusual behavior except for slightly elevated amounts of sodium in the SE samples. This summary represents the final Salt Batch processed through MCU prior to commencement of process and transfer line tie-ins to support the startup of the Salt Waste Processing Facility (SWPF).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impacts of the Addition of Sodium Reactor Experiment (SRE) and DR-3 Fuel from H-Canyon to Tank 40 on Acid Stoichiometry and Hydrogen Production

H-Canyon plans to discard Sodium Reactor Experiment (SRE) material that is currently stored in Tanks 16.3 and 16.4. Savannah River Remediation (SRR) determined that a portion of the SRE material can be added to Sludge Batch 9 (SB9) in Tank 40 and the remainder will be added to Sludge Batch 10 (SB10) that is currently being prepared in Tank 51. A processing flowsheet for both the nitric-formic acid flowsheet and the nitric-glycolic acid flowsheet were previously developed for SB9 sludge-only and coupled operation with the Actinide Removal Process – Modular Caustic Side Solvent Extraction Unit (ARP-MCU) and the Salt Waste Processing Facility (SWPF). Due to the compositional change in Tank 40 after the addition of SRE material, it is necessary to determine the influence on the acid stoichiometry operating window and hydrogen production for SB9 processing. An assessment was completed to address the influence of an addition of SRE and DR-3 Fuel from H-Canyon on the chemistry of Tank 40, the defined acid stoichiometry window (with and without SWPF streams) for the nitric-formic and nitric-glycolic acid flowsheets, and the resulting influence of the hydrogen production. Hydrogen production during the SRAT/SME cycles consists of thermolytic, radiolytic, and catalytic hydrogen. For the nitric-formic acid flowsheet, catalytic hydrogen dominates the hydrogen production during DWPF operation mode for the SRAT and SME vessels. This report was written to summarize that assessment. No SRNL testing is needed prior to adding up to 7,100 additional gallons of SRE and DR-3 Fuel from H-Canyon to Tank 40. Also, the addition of SRE will not exceed the Shielded Cells reported values for catalytic hydrogen for either the nitric-formic acid flowsheet (Technical Safety Requirement (TSR) limit of 0.15 lb/h) or the nitric-glycolic acid flowsheet (TSR limit 0.024 lb/h). The addition of the ARP stream from SWPF and the use of the nitric-glycolic acid flowsheet are both expected to decrease hydrogen generation, leading to a larger safety margin in the CPC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 49H Solids Disturbance Analysis

Tank 49H will serve as the feed tank for the Salt Waste Processing Facility (SWPF). Transfers into Tank 49H may disturb solids that have settled to the bottom of the tank, resulting in feed that may exceed the insoluble solids content limit of 1200 mg/L from the SWPF Waste Acceptance Criteria (WAC). During a transfer into Tank 49H, material that free falls from the Tank 49H B4 downcomer and passes through the supernate could potentially disturb the solids on the bottom of the tank and scour or suspend solids from a settled solids layer or turbid region. The scope of this task is to perform fluid flow analysis to determine the impact of a “plunging jet” through the B4 downcomer on solids in Tank 49H and to determine a minimum liquid level to be maintained in Tank 49H prior to transfers that will minimize disturbing the solids and exceeding the SWPF WAC limits for insoluble solids carryover to SWPF.

54 ENVIRONMENTAL SCIENCES↗

Tank 49H Solids Disturbance Analysis

Tank 49H will serve as the feed tank for the Salt Waste Processing Facility (SWPF). Transfers into Tank 49H may disturb solids that have settled to the bottom of the tank, resulting in feed that may exceed the insoluble solids content limit of 1,200 mg/L from the SWPF Waste Acceptance Criteria (WAC). During a transfer into Tank 49H, material that free falls into Tank 49H through a downcomer and passes through the supernate could potentially disturb the solids on the bottom of the tank and scour or suspend solids from a settled solids layer or turbid region. A previous analysis and report evaluated the potential to disturb solids when transferring into Tank 49H through the B4 riser and recommended a minimum tank level of 120 inches to prevent disturbing any solids in the bottom of the tank. The scope of this task is to perform additional fluid flow analysis to determine the impact of a “plunging jet” through the C3 downcomer on solids in Tank 49H and to determine a minimum liquid level to be maintained in Tank 49H prior to transfers that will minimize disturbing the solids and exceeding the SWPF WAC limits for insoluble solids carryover to SWPF since the C3 riser downcomer is at a lower elevation and farther away from the B5 transfer pump than the B4 downcomer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Antifoam Development for Eliminating Flammability Hazards and Decreasing Cycle Time in the Defense Waste Processing Facility

Foam, due to the high gas generation rates of boiling and chemical reaction offgasing, requires control measures to prevent the foam from contaminating the condensate and to facilitate efficient plant operation. Antifoam was utilized to minimize foam production during chemical processing in the DWPF and during High-Level Waste (HLW) evaporation at SRS and Hanford. However, the current antifoam used in the SRS DWPF increases flammability risk during chemical processing (generates three flammable degradation products) and while feeding the melter (can decompose to CO/hydrogen). It is also the likely source of methyl functional groups for the organo-mercury present in the tank farm and excessive mercury in Saltstone. Additionally, the planned startup of Salt Waste Processing Facility (SWPF), with much higher throughput, will challenge DWPF to process at higher gas generation rates. DWPF employs Antifoam 747, a superspreader produced by Momentive Performance Materials, as an antifoaming agent during waste processing. During DWPF chemical processing, antifoam must be effective up to boiling (i.e., up to 103°C) and between a pH of 3-13. Antifoam 747 is most effective at a pH range of 6-8 and degrades as pH deviates. In addition, SRNL identified three flammable antifoam degradation products using mass spectrometer (MS) and fourier transform infrared (FTIR) offgas analyzers during simulations. A new antifoam or a new method to control foam is needed to minimize DWPF processing time and reduce the risk of contamination. In addition, testing should be completed to ensure that other antifoams used in HLW processing do not have similar flammability hazards or cause unintended impacts in downstream processing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Assessment of the Materials of Construction for the Transfer Lines and Unit Operations Equipment Associated with the Recycle Diversion Process

The Defense Waste Processing Facility (DWPF) processes and vitrifies radioactive waste that it receives from the Concentration, Storage, and Transfer Facility (CSTF) and Salt Waste Processing Facility (SWPF). As a result of the evaporation of water during both the melter feed preparation and the melter feed vitrification steps in DWPF, a recycle waste stream is generated, neutralized, and sent back to the CSTF. The recycle waste is a dilute water stream originating from the collection of condensate liquids containing some minor sludge and frit solids and other waste components primarily resulting from entrainment into the condensate during foam-over events. The recycle stream volume is significant and is expected to approach 3 million gallons per year once the SWPF reaches full operation. Diverting the bulk of the recycle waste stream from the CSTF is essential for the eventual closure of the waste tanks, and hence the completion of the SRS liquid waste mission.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Evaluation of the Impact of Glycolate and Glycolate Mitigation on the Defense Waste Processing Facility Recycle Diversion Project Flowsheet

The Savannah River Site (SRS) Defense Waste Processing Facility (DWPF) processes radioactive High Level Waste (HLW) sludge solids from the Concentration, Storage, and Transfer Facilities (CSTF); which includes the SRS Tank Farm and Evaporator facilities, and a concentrated Cs-137 laden stream and a Monosodium Titanate (MST) and sludge solids stream from the SRS Salt Waste Processing Facility (SWPF). The waste is chemically adjusted with acids and reductant (currently with 50 wt.% nitric acid and ~90 wt.% formic acid, but eventually formic acid will be substituted with ~70 wt.% glycolic acid), and frit is added so that a durable, borosilicate glass waste form can be produced when the material is vitrified in the melter. As a result of the evaporation of water during both the melter feed preparation and the melter feed vitrification steps in DWPF, a recycle waste stream is generated, neutralized, and sent back to the CSTF. The recycle waste is a dilute aqueous stream originating from the collection of condensate liquids containing some minor sludge, MST, and frit solids and other waste components resulting from melter feed entrainment during foamover events and transfer of volatile species into the condensate. The recycle stream volume is significant and is expected to approach 3 million gallons per year once SWPF reaches full operation, requiring the use of multiple large CSTF tanks for storage. The recycle waste is currently collected in the SRS Tank Farm and periodically evaporated in the 242-16H (2H) Evaporator to conserve storage space.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 49H Solids Disturbance Analysis

Tank 49H will serve as the feed tank for the Salt Waste Processing Facility (SWPF). Transfers into Tank 49H may disturb solids that have settled to the bottom of the tank, resulting in feed that may exceed the insoluble solids content limit of 1,200 mg/L from the SWPF Waste Acceptance Criteria (WAC). During a transfer into Tank 49H, material that free falls into Tank 49H through a downcomer and passes through the supernate could potentially disturb the solids on the bottom of the tank and scour or suspend solids from a settled solids layer or turbid region. A previous analysis and report evaluated the potential to disturb solids when transferring into Tank 49H through the B4 riser and recommended a minimum tank level of 120 inches to prevent disturbing any solids in the bottom of the tank. The scope of this task is to perform additional fluid flow analysis to determine the impact of a “plunging jet” through the C3 downcomer on solids in Tank 49H and to determine a minimum liquid level to be maintained in Tank 49H prior to transfers that will minimize disturbing the solids and exceeding the SWPF WAC limits for insoluble solids carryover to SWPF since the C3 riser downcomer is at a lower elevation and farther away from the B5 transfer pump than the B4 downcomer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗