Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Steady State Temperature Profile in a Cylinder Heated by Microwaves

A new theory has been developed to calculate the steady state temperature profile in a cylindrical sample positioned along the entire axis of a cylindrical microwave cavity. Temperature profiles where computed for- alumina rods of various radii contained in a cavity excite in one of the TM(sub OnO) modes with n = 1, 2 or 3. Calculations where also performed with a concentric outer cylindrical tube surrounding the rod to investigate hybrid heating. The parameters studies of the sample center and surface temperature where performed as a function of the total power transmitted into the cavity. Also, the total hemispherical emissivity was varied at boundaries of the rod, surrounding tube, and cavity walls. The result are discussed in the context of controlling the average rod temperature and the temperature distribution in the rod during microwave processing.

Jackson, H. W.↗

Compact femtosecond electron diffractometer with 100 keV electron bunches approaching the single-electron pulse duration limit

We present the design and implementation of a highly compact femtosecond electron diffractometer working at electron energies up to 100 keV. We use a multi-body particle tracing code to simulate electron bunch propagation through the setup and to calculate pulse durations at the sample position. Our simulations show that electron bunches containing few thousands of electrons per bunch are only weakly broadened by space-charge effects and their pulse duration is thus close to the one of a single-electron wavepacket. With our compact setup, we can create electron bunches containing up to 5000 electrons with a pulse duration below 100 fs on the sample. We use the diffractometer to track the energy transfer from photoexcited electrons to the lattice in a thin film of titanium. This process takes place on the timescale of few-hundred femtoseconds and a fully equilibrated state is reached within 1 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

hpMCA: A Python-based Graphical Program for Energy Dispersive X-Ray Diffraction Data Collection and Analysis

Energy-dispersive X-ray diffraction (EDXD) at synchrotron beamlines is commonly used for the study of material properties under high pressure and/or high temperature. Experimenters typically rely on the availability of robust data collection and analysis at a beamline, but this has become increasingly difficult, especially with the introduction of multi-element detectors that generate complex, multi-dimensional data sets. These data sets have energy resolution, and they can also be resolved in relation to sample position, diffraction angle, or different external stimuli. We report a new Python-based graphical program, hpMCA, for EDXD data collection and analysis that streamlines the experimental process for the beamline users. The program features a user-friendly interface, capability for online viewing and analyzing data from multi-element energy-dispersive detectors, and includes features useful for working with samples under high pressure and/or high temperature, such as crystal phase identification, real-time unit cell lattice refinement, and pressure determination based on an equation of state.

data analysis software↗

Automated Liquid Microjunction Surface Sampling-HPLC-MS/MS Analysis of Drugs and Metabolites in Whole-Body Thin Tissue Sections

A fully automated liquid extraction-based surface sampling system utilizing a commercially available autosampler coupled to high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) detection is reported. Discrete spots selected for droplet-based sampling and automated sample queue generation for both the autosampler and MS were enabled by using in-house developed software. In addition, co-registration of spatially resolved sampling position and HPLC-MS information to generate heatmaps of compounds monitored for subsequent data analysis was also available in the software. The system was evaluated with whole-body thin tissue sections from propranolol dosed rat. The hands-free operation of the system was demonstrated by creating heatmaps of the parent drug and its hydroxypropranolol glucuronide metabolites with 1 mm resolution in the areas of interest. The sample throughput was approximately 5 min/sample defined by the time needed for chromatographic separation. The spatial distributions of both the drug and its metabolites were consistent with previous studies employing other liquid extraction-based surface sampling methodologies.

drug metabolism↗

Scanning structural mapping at the Life Science X-ray Scattering Beamline

This work describes the instrumentation and software for microbeam scattering and structural mapping at the Life Science X-ray Scattering (LiX) beamline at NSLS-II. Using a two-stage focusing scheme, an adjustable beam size between a few micrometres and a fraction of a millimetre is produced at the sample position. Scattering data at small and wide angles are collected simultaneously on multiple Pilatus detectors. A recent addition of an in-vacuum Pilatus 900k detector, with the detector modules arranged in a C-shaped configuration, has improved the azimuthal angle coverage in the wide-angle data. As an option, fluorescence data can be collected simultaneously. Fly scans have been implemented to minimize the time interval between scattering patterns and to avoid unnecessary radiation damage to the sample. For weakly scattering samples, an in-vacuum sample environment has been developed here to minimize background scattering. Data processing for these measurements is highly sample-specific. To establish a generalized data process workflow, first the data are reduced to reciprocal coordinates at the time of data collection. The users can then quantify features of their choosing from these intermediate data and construct structural maps. As examples, results from in-vacuum mapping of onion epidermal cell walls and 2D tomographic sectioning of an intact poplar stem are presented.

36 MATERIALS SCIENCE↗

FaNGaS: a New Instrument for Fast Neutron Gamma Spectroscopy at FRM II Research Reactor at Garching

For the identification and quantification of actinides in radioactive packages, the non-destructive method of Prompt-Gamma Activation Analysis (PGAA) is applied. To investigate the inelastic (n, n 'γ) scattering, a new instrumentation was installed at the FRM II research reactor. It is designed to exploit the 10{sup 8} cm{sup -2}s{sup -1} neutrons at an average neutron energy of 1.9 MeV delivered by the SR10 beam line. The outgoing prompt γ-rays are measured utilizing a 50% efficiency HPGe detector. Since the cross sections are expected to be low for such a process, two related factors had to be taken into account for the design of the instrumentation: the high beam intensity at the sample position and the high signal-to-background ratio seen by the detector. Eventual low energy neutrons due to the multiple scatterings through the beam line can be minimized using collimators in the beam tube. This has also an effect to a prior neutrons and photons background reduction of the experimental environment. A higher efficiency of the counting can be achieved by the lowering of background at the detector. In this case, a heavy shielding for both neutrons and photons, is designed around the detector while optimizing the sample-detector distance. Monte-Carlo simulation studies were conducted to effectively design the fast neutron beam collimators and the detector shield. A detailed description of the setup characterization and results from simulations and experimental measurements will be discussed through this contribution. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Search of strong lens systems in the Dark Energy Survey using convolutional neural networks

We present our search for strong lens, galaxy-scale systems in the first data release of the Dark Energy Survey (DES), based on a color-selected parent sample of 18 745 029 luminous red galaxies (LRGs). We used a convolutional neural network (CNN) to grade this LRG sample with values between 0 (non-lens) and 1 (lens). Our training set of mock lenses is data-driven, that is, it uses lensed sources taken from HST-COSMOS images and lensing galaxies from DES images of our LRG sample. A total of 76 582 cutouts were obtained with a score above 0.9, which were then visually inspected and classified into two catalogs. The first one contains 405 lens candidates, of which 90 present clear lensing features and counterparts, while the other 315 require more evidence, such as higher resolution imaging or spectra, to be conclusive. A total of 186 candidates are newly identified by our search, of which 16 are among the 90 most promising (best) candidates. The second catalog includes 539 ring galaxy candidates. This catalog will be a useful false positive sample for training future CNNs. For the 90 best lens candidates we carry out color-based deblending of the lens and source light without fitting any analytical profile to the data. This method is shown to be very efficient in the deblending, even for very compact objects and for objects with a complex morphology. Finally, from the 90 best lens candidates, we selected 52 systems with one single deflector to test an automated modeling pipeline that has the capacity to successfully model 79% of the sample within an acceptable computing runtime.

79 ASTRONOMY AND ASTROPHYSICS↗

Relationship of Imaging Frequency and Planning Margin to Account for Intrafraction Prostate Motion: Analysis Based on Real-Time Monitoring Data

Purpose: Correction for intrafraction prostate motion becomes important for hypofraction treatment of prostate cancer. The purpose of this study was to estimate an ideal planning margin to account for intrafraction prostate motion as a function of imaging and repositioning frequency in the absence of continuous prostate motion monitoring. Methods and Materials: For 31 patients receiving intensity modulated radiation therapy treatment, prostate positions sampled at 10 Hz during treatment using the Calypso system were analyzed. Using these data, we simulated multiple, less frequent imaging protocols, including intervals of every 10, 15, 20, 30, 45, 60, 90, 120, 180, and 240 seconds. For each imaging protocol, the prostate displacement at the imaging time was corrected by subtracting prostate shifts from the subsequent displacements in that fraction. Furthermore, we conducted a principal component analysis to quantify the direction of prostate motion. Results: Averaging histograms of every 240 and 60 seconds for all patients, vector displacements of the prostate were, respectively, within 3 and 2 mm for 95% of the treatment time. A vector margin of 1 mm achieved 91.2% coverage of the prostate with 30 second imaging. The principal component analysis for all fractions showed the largest variance in prostate position in the midsagittal plane at 54° from the anterior direction, indicating that anterosuperior to inferoposterior is the direction of greatest motion. The smallest prostate motion is in the left-right direction. Conclusions: The magnitudes of intrafraction prostate motion along the superior-inferior and anterior-posterior directions are comparable, and the smallest motion is in the left-right direction. In the absence of continuous prostate motion monitoring, and under ideal circumstances, 1-, 2-, and 3-mm vector planning margins require a respective imaging frequency of every 15, 60, and 240 to account for intrafraction prostate motion while achieving adequate geometric target coverage for 95% of the time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

General guide concepts for compact, high-brilliance neutron moderators

The trend in neutron sciences is toward integrating compact, high-brightness moderators into new or upgraded facilities. Transporting neutrons from the source to the sample position with a phase-space distribution tailored to specific requirements is crucial to leverage high source brilliance. Here we have investigated four guide concepts using Monte Carlo ray tracing simulations: Montel beamline with nested Kirkpatrick–Baez mirrors, curved-tapered beamline with a bender and straight sections, straight-elliptical beamline, and curved-elliptical beamline. The straight-elliptical (curved-elliptical) beamline features two half-ellipse guides connected by a straight (non-straight) guide section. The neutron transport efficiency and phase space homogeneity have been quantitatively compared. Our results show that the straight-elliptical beamline performs best because of few neutron bounces on the guide surface with small reflection angles, minimizing flux loss. The Montel beamline provides the best spatial confinement of neutrons within the desired region; however, there is a high thermal-neutron loss due to large reflection angles. The curved-tapered beamline suffers from significant flux loss due to high bounces, and it shows a non-uniform angular distribution related to broad ranges of bounces and reflection angles. The non-straight guide section of the curved-elliptical beamline increases the phase space inhomogeneity, leading to a spatially non-uniform beam profile. The results apply to general neutron instruments that require transporting thermal and cold neutrons from a compact, high-brilliance moderator to the sample location with a moderate phase-space volume.

47 OTHER INSTRUMENTATION↗

An Overview of the Hybrid Illinois Device for Research and Applications Material Analysis Test-stand (HIDRA-MAT)

The Hybrid Illinois Device for Research and Applications (HIDRA) at the University of Illinois at Urbana-Champaign is a toroidal plasma device that enables fusion plasma-material interaction testing with both stellarator and tokamak plasmas. HIDRA’s long-pulse steady state stellarator plasmas provide a testbed for plasma facing component (PFC) plasma exposures. The HIDRA Material Analysis Test-stand (HIDRA-MAT) is a material characterization module attached to HIDRA that is being designed and fabricated to include thermal desorption spectroscopy and laser induced breakdown spectroscopy systems for in-vacuo PFC characterization. A specialized rotatable sample holder positions the sample for liquid metal droplet application from a liquid metal droplet injector on HIDRA-MAT. Early experiments look to investigate the effect liquid lithium has on porous tungsten samples’ retention of H, D, and He after plasma exposure. Preliminary results from a dual residual gas analyzer system show the ability to differentiate D2 and He in HIDRA-MAT. Finally, this work aims to advance the understanding of liquid metal PFCs and further the design and development of new fusion PFCs and technologies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Linear Reciprocating Tribometer for In Situ Neutron Reflectometry of Soft Matter

Neutron reflectometry is a technique for measuring structure near planar interfaces that has been previously used to non-destructively characterize the polymer density of hydrated, dilute, and soft materials. Previous investigations have conducted neutron reflectometry measurements of liquids, gels, emulsion, and polymer solutions at rest, in compression, and subject to shear stress. However, correlating structure with tribological properties of soft materials presents significant experimental challenges for prior instruments due to wall slip, sample thickness, and structural heterogeneity (e.g., depth-wise gradients). A linear reciprocating tribometer offers several advantages for in situ neutron reflectometry studies, including uniform velocity profiles, constant shear stress over large regions of interest, and independent control of normal force and sliding velocity during measurements. This work outlines basic considerations for the design of a custom linear reciprocating tribometer that operates in a neutron beamline and includes commissioning measurements. The tribometer is designed to compress soft and hydrated materials against linearly reciprocating silicon disks. The three key design considerations for this tribometer are (1) safety, (2) neutron transmission, and (3) sample positioning. This instrument design will enable in situ studies of soft matter and illuminate the role of interfacial structure on tribological phenomena.

42 ENGINEERING↗

New insights into water bonding during early tricalcium silicate hydration with quasielastic neutron scattering

New information on the water bonding during the first 36 h of hydration of tricalcium silicate was obtained using the high neutron flux at the sample position of the time-of-flight spectrometer (TOFTOF), FRM II in Garching, Germany, together with {sup 29}Si NMR and X-ray diffraction measurements. A rapid increase in the amount of constrained water was observed at the beginning of the induction period. This is attributed to the formation of an early C-S-H with a large specific surface area (around 800 m{sup 2}/g). During subsequent hydration, the amount of constrained water, as given by the total surface area of the hydration products, is controlled by (a) the formation of new metastable early C-S-H which increases total surface area and (b) polymerisation processes which reduce total surface area. The relative contribution of these processes varies during hydration.

36 MATERIALS SCIENCE↗

Molecular characterization of Cryptococcus neoformans and Cryptococcus gattii from environmental sources and genetic comparison with clinical isolates in Apulia, Italy

Highlights: • Meta-analysis of data recorded during environmental surveys of Cryptococcus spp in Apulia. • Olive trees can be an alternative ecological niche for C. neoformans and C. gattii. • Correlation clinical cases with possible new environmental sources of infection. The present study investigated the environmental distribution of Cryptococcus neoformans and C. gattii species complex molecular types, mating types and sequence types in Apulia, a region of Southern Italy. A total of 2078 specimens from arboreal and animal sources were analyzed. The percentage of positive samples was similar among both arboreal and animal specimens: 4.2% vs. 5.1% for C. neoformans species complex and 0.6% vs. 1.4% for C. gattii species complex. Molecular typing identified 78 isolates as VNI (76 αA and two aA), one as AD-hybrid αADa, and 16 as VGI aB. VNI isolates presented 10 different sequence types (STs) and VGI isolates two. The most frequent STs among C. neoformans and C. gattii species complex isolates were ST23 (51%) and ST156 (90%), respectively. Comparison with molecular types and STs results obtained from 21 clinical isolates collected in Apulia showed that one C. neoformans VNI clinical isolate shared an identical sequence type of one arboreal isolate (ST61) and that one C. gattii VGI clinical isolate matched with the main ST (ST156) present in the environment. In addition, molecular type VNIV was found only among clinical isolates and was absent in the investigated environmental area. In conclusion, the present study identified which C. neoformans and C. gattii species complex genotypes are circulating in Apulia, defined their ecological niches and revealed the relationship with clinical cases. It represents a basal study for addressing future investigations and public health interventions in the region.

54 ENVIRONMENTAL SCIENCES↗

Antibody-independent Targeted Quantification of TMPRSS2-ERG Fusion Protein Products in Prostate Cancer

Fusions between the transmembrane protease serine 2 (TMPRSS2) and ETS related gene (ERG) represent one of the most specific biomarkers that define a distinct molecular subtype of prostate cancer. The studies on TMPRSS2-ERG gene fusions have seldom been performed at the protein level, primarily due to the lack of high-quality antibodies or an antibody-independent method that is sufficiently sensitive for detecting the truncated ERG protein products resulting from TMPRSS2-ERG gene fusions and alternative splicing. Herein, we applied a recently developed PRISM (high-pressure high-resolution separations with intelligent selection and multiplexing)-SRM (selected reaction monitoring) strategy for quantifying ERG protein in prostate cancer cell lines and tumors. The highly sensitive PRISM-SRM assays led to confident detection of 6 unique ERG peptides in either the TMPRSS2-ERG positive cell lines or tissues but not in the negative controls, indicating that ERG protein expression is highly correlated with TMPRSS2-ERG gene rearrangements. Significantly, our results demonstrated for the first time that at least two groups of ERG protein isoforms were simultaneously expressed at variable levels in TMPRSS2-ERG positive samples as evidenced by concomitant detection of two mutually exclusive peptides. Three peptides shared across almost all fusion protein products were determined to be the most abundant peptides, and hence can be used as “signature” peptides for detecting ERG overexpression resulting from TMPRSS2-ERG gene fusion. These PRISM-SRM assays provide valuable tools for studying TMPRSS2-ERG gene fusion protein products, thus improving our understanding of the role of TMPRSS2-ERG gene fusion in the biology of prostate cancer.

Environmental Molecular Sciences Laboratory↗

The intermediate energy X-ray beamline at the APS

In this work, we report the optical design of the Intermediate Energy X-ray (IEX) beamline at the APS, which has been optimized to study emergent phenomena via angle-resolved photoemission spectroscopy (ARPES) and resonant soft X-ray scattering (RSXS). Driven by the scientific requirements of these two techniques the beamline consists of two separate branchlines sharing the same source, heat absorbing optics and monochromator, but each having its own refocusing optics. The ARPES branch is optimized for a very high “resolving power” and a small spot at the sample; whereas, the RSXS branch is designed for high flux and a low beam divergence at the sample. The very high “resolving power” in the ARPES branch is achieved by using a monochromator which consists of a plane mirror and a variable line spacing grating that focuses the beam at all photon energies. A flux higher than 10 10 photons/s at a “resolving power” better than 5×10 4 will be available at the sample position of the ARPES beamline on a spot size (FWHM) smaller than 21×4 μm 2 (hor.×ver.) for photon energies between 250 and 1660 eV. A second grating will increase the flux by more than a factor of 10 at a “resolving power” of 10 4 . The flux expected at the RSXS branch for energies between 250 eV and 1900 eV is higher than 4×10 12 photons/s at “resolving power” around 2.5×10 3 . The expected spot in this branch is sub-millimeter and the beam divergence is less than 0.3 mrad (FWHM).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-temperature chemical expansion of Pr0.1Ce0.9O2-δ thin films determined by Differential Laser Doppler Vibrometry

The chemical expansion of thin-film praseodymium-cerium oxide solid solutions (Pr 0.1 Ce 0.9 O 2-δ , PCO10) is investigated at temperatures ranging from 500 °C to 800 °C and oxygen activities down to about 10 -22 . Differential Laser Doppler Vibrometry (D-LDV) in combination with periodic electrochemical pumping of oxygen is used to detect very small displacements of the sample surface. With decreasing pumping frequency, the film approaches chemical equilibrium, which is nearly reached at 700 °C below 0.01 Hz. D-LDV enables direct measurement of film thickness changes as well as the bending of the underlying substrates due electrochemically induced lateral mechanical stress. The substrate bending is found to be more than an order of magnitude larger than the film thickness change, increasing the detection limit by the same factor. The thickness change of the thin film is calculated from the measured displacement of the sample surface and compared with directly measured values. Thin-film literature data available for low oxygen activities up to 650 °C agree with our measurements. In addition, the thickness change of the film is determined from the displacement at different sample positions, which validates previous measurements. Finally, thin film chemical expansion is found to be larger by a factor of about 2 than the corresponding bulk value in agreement with predictions from a mechanical model that the out-of-plane expansion of a constrained film is increased.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sputter deposition of ultrathick Bi coatings onto rotating substrates for inertial confinement fusion

Sputter-deposited Bi is a potential candidate material for the production of inertial confinement fusion (ICF) hohlraums, which are sphero-cylindrical canisters that serve as the housing for hydrogen-fuel-filled capsules in ICF implosions. The fabrication of hohlraums involves deposition onto rotating sphero-cylindrical substrates and, hence, requires an understanding of oblique angle deposition phenomena. Here, we systematically study the effect of dynamic substrate tilt on properties of Bi films deposited onto rotating planar substrates. Results show that film morphology, porosity, and electrical resistivity depend on substrate tilt. In comparison with films deposited onto substrates adhered to a stationary sample holder, films deposited on rotating substrates have more uniform microstructure with fewer void defects. Based on Monte Carlo simulations, these changes in film morphology and microstructure are attributed to averaging and geometric effects related to sample position and rotation. In conclusion, the fabrication of an ∼ 50-µm-thick Bi film on a rotating sphero-cylindrical mandrel demonstrates a significant step toward the production of Bi hohlraums.

Bismuth↗