Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCINTILLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Highly lead-loaded red plastic scintillators as an X-ray imaging system for the Laser Mega Joule

The scope of this project intends to record spatially resolved images of core shape and size of a DT micro-balloon during Inertial Confinement Fusion (ICF) experiments at Laser Mega Joule facility (LMJ). We need to develop an X-ray imaging system which can operate in the radiative background generated by an ignition shot of ICF. The scintillator is a part of the imaging system and has to gather a compromise of scintillating properties (scintillating efficiency, decay time, emission wavelength) so as to both operate in the hard radiative environment and to allow the acquisition of spatially resolved images. Inorganic scintillators cannot be used because no compromise can be found regarding the expected scintillating properties, most of them are not fast enough and emit blue light. Organic scintillators are generally fast, but present low X-ray absorption in the 10 to 40 keV range, that does not permit the acquisition of spatially resolved images. To this aim, we have developed highly lead-loaded and red-fluorescent fast plastic scintillators. Such a combination is not currently available via scintillator suppliers, since they propose only blue-fluorescent plastic scintillators doped with up to 12%w Pb. Thus, incorporation ratio up to 27%w Pb has been reached in our laboratory, which can afford a plastic scintillator with an outstanding Z{sub eff} close to 50. X-rays in the 10 to 40 keV range can thus be detected with a higher probability of photoelectric effect than for classic organic scintillators, such as NE102. The strong orange-red fluorescence can be filtered, so that we can eliminate residual Cerenkov light, generated by {gamma}-ray absorption in glass parts of the imaging system. Decay times of our scintillators evaluated under UV excitation were estimated to be in the range 10 to 13 ns. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of new Polysiloxane Based Liquid Scintillators

In the last decade, attention toward neutron detection has been growing in the scientific community, driven by new requirements in different fields of application ranging from homeland security to medical and material analysis, from research physics, to nuclear energy production. So far neutron detection, with particular attention to fast neutrons, has been mainly based on organic liquid scintillators, owing to their good efficiency and pulse shape discrimination (PSD) capability. Most of these liquids have however some main drawbacks given by toxicity, flammability, volatility and sensitivity to dissolved oxygen that limits the duration and the quality of their performances with worse handiness and increased costs. Phenyl-substituted polysiloxanes could address most of these issues, being characterized by low toxicity, low volatility and low flammability. Their optical properties can be tailored by changing the phenyl distribution and concentration thus allowing to increase the solubility of organic dyes, to modify the fluorescence spectra and to vary the refractive index of the medium. Furthermore, polysiloxanes have been recently exploited for the production of plastic scintillators with very good chemical and thermal stability and very good radiation hardness and the development of polysiloxane liquid scintillators could allow to combine these interesting properties with the supremacy of liquid scintillators as regarding PSD over plastics. For these reasons, the properties of several phenyl-substituted polysiloxane with different phenyl amounts and different viscosities have been investigated, with particular attention to the scintillation response and the pulse shape discrimination capability, and the results of the investigation are reported in this work. More in details, the scintillation light yield towards gamma rays ({sup 60}Co and {sup 137}Cs) of several polysiloxane liquids has been analyzed and compared with the light yield of a commercial non-toxic liquid scintillator (EJ309). The results have been related to the optical characterization of these materials, especially as regarding the fluorescence response, and the best performing material (1,1,5,5-Tetraphenyl 1,3,3,5-Tetramethyl Trisiloxane) showed a scintillation light-yield only slightly lower than EJ309, proving to be a promising candidate for the production of an efficient polysiloxane based liquid scintillator. The results as regarding the neutron-gamma pulse shape discrimination capability of the best performing materials are also reported in this work and the scintillation decay time of these materials are compared to the results of fluorescence lifetime analysis. PSD tests have been performed at CN accelerator in Legnaro National Laboratories with a 2.2 MeV pulsed neutron beam using TOF procedure and the pulses have been analyzed in order to evidence the PSD capability of every sample. The reported results pave the way to the development of a new promising class of non-toxic liquid scintillating materials for neutron detection, with good light output and interesting PSD characteristics. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Boron-Based Neutron Scintillator Screens for Neutron Imaging

In digital neutron imaging, the neutron scintillator screen is a limiting factor of spatial resolution and neutron capture efficiency and must be improved to enhance the capabilities of digital neutron imaging systems. Commonly used neutron scintillators are based on 6 LiF and gadolinium oxysulfide neutron converters. This work explores boron-based neutron scintillators because 10 B has a neutron absorption cross-section four times greater than 6Li, less energetic daughter products than Gd and 6 Li, and lower γ-ray sensitivity than Gd. These factors all suggest that, although borated neutron scintillators may not produce as much light as 6 Li-based screens, they may offer improved neutron statistics and spatial resolution. This work conducts a parametric study to determine the effects of various boron neutron converters, scintillator and converter particle sizes, converter-to-scintillator mix ratio, substrate materials, and sensor construction on image quality. The best performing boron-based scintillator screens demonstrated an improvement in neutron detection efficiency when compared with a common 6 LiF/ZnS scintillator, with a 125% increase in thermal neutron detection efficiency and 67% increase in epithermal neutron detection efficiency. The spatial resolution of high-resolution borated scintillators was measured, and the neutron tomography of a test object was successfully performed using some of the boron-based screens that exhibited the highest spatial resolution. For some applications, boron-based scintillators can be utilized to increase the performance of a digital neutron imaging system by reducing acquisition times and improving neutron statistics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of scintillator-based detectors for few-ten-keV high-spatial-resolution x-ray imaging

Purpose: High-spatial-resolution x-ray imaging in the few-ten-keV range is becoming increasingly important in several applications, such as small-animal imaging and phase-contrast imaging. The detector properties critically influence the quality of such imaging. Here the authors present a quantitative comparison of scintillator-based detectors for this energy range and at high spatial frequencies. Methods: The authors determine the modulation transfer function, noise power spectrum (NPS), and detective quantum efficiency for Gadox, needle CsI, and structured CsI scintillators of different thicknesses and at different photon energies. An extended analysis of the NPS allows for direct measurements of the scintillator effective absorption efficiency and effective light yield as well as providing an alternative method to assess the underlying factors behind the detector properties. Results: There is a substantial difference in performance between the scintillators depending on the imaging task but in general, the CsI based scintillators perform better than the Gadox scintillators. At low energies (16 keV), a thin needle CsI scintillator has the best performance at all frequencies. At higher energies (28–38 keV), the thicker needle CsI scintillators and the structured CsI scintillator all have very good performance. The needle CsI scintillators have higher absorption efficiencies but the structured CsI scintillator has higher resolution. Conclusions: The choice of scintillator is greatly dependent on the imaging task. The presented comparison and methodology will assist the imaging scientist in optimizing their high-resolution few-ten-keV imaging system for best performance.

60 APPLIED LIFE SCIENCES↗

SU-E-T-763: Towards the Mechanical Doping of Plastic Scintillators

Purpose: The doping of plastic scintillators with high-Z elements changes the radiation interaction cross section of the medium and therefore changes the intrinsic response of the detector. The selection of doped plastic scintillators available commercially is limited. This research aims to develop a novel methodology for the mechanical doping of plastic scintillating materials. The ultimate goal of this project is to use doped scintillators of varying intrinsic behavior to unfold the LET (energy) spectrum of any radiation beam. Methods: Commercially available BC408 plastic scintillator was obtained and crushed into uniform powder (using ball mill). Two separate materials were tested for light output signal: uncrushed scintillator and scintillating powder bound by glue. Commercially available U301 UV-hardening glue was used. Scintillation response was measured by creating a thin housing of black acrylic that allowed light from each scintillator to be guided to an optical fiber via a taper. The optical fiber was connected to a PMT; signal was measured using an electrometer. Tests were conducted to determine if crushing+bonding distorted linearity and energy dependence of detector response. Linearity was tested for by irradiating (uncrushed and crushed+glued) for varying durations ensuring signal scaled accordingly; this was done using 300kV x-rays and 6MeV electrons. The effect on energy dependence was examined by obtaining a signal ratio (100kV vs. 300kV; 6MeV vs. 18MeV) for both uncrushed and crushed+glued scintillating material. Results: Crushing and binding with U301 glue did not have an effect on linearity. Energy dependence was changed by 20.3%; crushing+bonding decreased the sensitivity at low energy radiation. Conclusion: This work indicates that crushing and binding of plastic scintillating material does not change the linearity of its response to radiation but does have an effect on the energy dependence. Future work involves addition of high-Z dopants (W, Mo, Pb) and characterization of the detector response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced inorganic halide ceramic scintillators

Research in ceramic scintillators has steadily progressed alongside the research in bulk single crystal scintillator growth. As interest in faster scintillation material production with lower cost increases, more research on scintillating ceramics is needed. Research targeting optimization of optically transparent ceramics that can rival bulk-grown crystals grown may lower cost, increase yield, increase volume, and improve energy resolution in applications and systems currently using sodium iodide and alike. Ceramic scintillators that are dense (>5 g/cm 3 ), have high effective Z (>60), are bright (>40,000 photons/MeV), and are not sensitive to moisture as well as those that can be handled without protection are desired. Ultra-fast ceramic materials are also of interest. This paper presents an equipment design and technique to produce inorganic halide ceramic scintillators Cs 2 HfCl 6 (CHC) and Tl 2 HfCl 6 (THC). Improvements and optimization of CHC and THC ceramic scintillator fabrication are gauged by monitoring the energy resolution and peak position of 137 Cs full energy peak at 662 keV. With a 1-inch diameter CHC ceramic scintillator, energy resolution of 5.4% (FWHM) and light yield of 20,700 ph/MeV are achieved, while with a 16-mm diameter THC ceramic scintillator, energy resolution of 5.1% (FWHM) and light yield of 27,800 ph/MeV are achieved. Decay times of 0.6 μs (21%) and 3.0 μs (79%) are measured for CHC and 0.3 μs (13%) and 1.0 μs (87%) for THC. Here, both ceramic CHC and THC scintillators have similarly good proportionality data when compared to their single crystal counterparts.

36 MATERIALS SCIENCE↗

SU-E-T-782: Using Light Output From Doped Plastic Scintillators to Resolve the Linear Energy Transfer Spectrum of Clinical Electron Beams

Purpose: This research seeks to develop a portable, clinically-suitable linear energy transfer (LET) detector. In radiotherapy, absorbed dose is commonly used to measure the amount of delivered radiation, though, it is not a good indicator of actual biological damage. LET is the energy absorbed per unit length by a medium along charged particle’s pathway; studies have shown that LET correlates well with relative biological effectiveness (RBE). Methods: According to Birks’ law, light output of plastic scintillators is stopping-power dependent. This dependency can be varied through doping by various high-Z elements. By measuring light output signals of differently doped plastic scintillators (represented by column vector S, where each row corresponds to different scintillator material), the fluence of charged particles of a given LET (represented by column vector Φ, where each row corresponds to different LET bins) can be unfolded by S=R*Φ where R is system response matrix (each row represents a different scintillator, each column corresponds to different electron LET). Monte Carlo (MC) GEANT4.10.1 was used to evaluate ideal detector response of BC408 scintillating material doped with various concentrations of several high Z dopants. Measurements were performed to validate MC. Results: Signal for 1%-lead doped BC408 and the non-doped scintillator was measured experimentally by guiding light emitted by the scintillator (via in-house made taper, fiber system) to a PMT and then an electrometer. Simulations of 1%Pb-doped scintillator to non-doped scintillator revealed 9.3% reduction in light output for 6 MeV electrons which compared well (within uncertainty) with measurements showing 10% reduction (6MeV electrons). Conclusion: Measurements were used to validate MC simulation of light output from doped scintillators. The doping of scintillators is a viable technique to induce LET dependence. Our goal is to use this effect to resolve the LET spectrum of an incident beam.

60 APPLIED LIFE SCIENCES↗

Scintillator Efficiency Study with MeV X-Rays

We have investigated scintillator efficiency for MeV radiographic imaging. This paper discusses the modeled detection efficiency and measured brightness of a number of scintillator materials. An optical imaging camera records images of scintillator emission excited by a pulsed x-ray machine. The efficiency of various thicknesses of monolithic LYSO:Ce (cerium-doped lutetium yttrium orthosilicate) are being studied to understand brightness and resolution trade-offs compared with a range of micro-columnar CsI:Tl (thallium-doped cesium iodide) scintillator screens. The micro-columnar scintillator structure apparently provides an optical gain mechanism that results in brighter signals from thinner samples. The trade-offs for brightness versus resolution in monolithic scintillators is straightforward. For higher-energy x-rays, thicker materials generally produce brighter signal due to x-ray absorption and the optical emission properties of the material. However, as scintillator thickness is increased, detector blur begins to dominate imaging system resolution due to the volume image generated in the scintillator thickness and the depth of field of the imaging system. We employ a telecentric optical relay lens to image the scintillator onto a recording CCD camera. The telecentric lens helps provide sharp focus through thicker-volume emitting scintillators. Stray light from scintillator emission can also affect the image scene contrast. We have applied an optical light scatter model to the imaging system to minimize scatter sources and maximize scene contrasts.

scintillator, radiography, CCD camera, hard x-ray,↗

Kinetic Monte Carlo simulations of scintillation processes in NaI(Tl)

Developing a comprehensive understanding of the processes that govern the scintillation behavior of inorganic scintillators provides a pathway to optimize current scintillators and allows for the science-driven search for new scintillator materials. Recent experimental data on the excitation density dependence of the light yield of inorganic scintillators presents an opportunity to incorporate parameterized interactions between excitations in scintillation models and thus enable more realistic simulations of the nonproportionality of inorganic scintillators. Therefore, a kinetic Monte Carlo (KMC) model of elementary scintillation processes in NaI(Tl) is developed in this work to simulate the kinetics of scintillation for a range of temperatures and Tl concentrations as well as the scintillation efficiency as a function of excitation density. The ability of the KMC model to reproduce available experimental data allows for elucidating the elementary processes that give rise to the kinetics and efficiency of scintillation observed experimentally for a range of conditions.

Kerisit, Sebastien N.↗

Systems and methods for assaying a radioactive gas, and related scintillation cells

A radioactive gas assay system comprises a scintillation cell production assembly, a detector assembly, a computer assembly, and a scintillation cell destruction assembly. The scintillation cell production assembly is configured to produce a scintillation cell comprising a glass scintillator shell containing a volume of radioactive gas. The detector assembly is configured to receive the scintillation cell and to detect photons emitted thereby. The computer assembly is configured to receive data from the detector assembly to automatically calculate an absolute activity of the volume of radioactive gas of the scintillation cell and radiation detection efficiencies of the detector assembly. The scintillation cell destruction assembly is configured to receive the scintillation cell and to rupture the substantially non-porous glass scintillator shell to release the volume of radioactive gas. A method of assaying a radioactive gas, and a scintillation cell are also described.

Robinson, Troy A.↗

Radiation hard gallium oxide scintillators for high count rate radiation detection

Despite decades of materials research, the availability of appropriate crystalline radiation-hard scintillators with ultrafast decay times (~10ns) and high light yields (>2000 ph/MeV) are still limited. In this study, we demonstrate the potential of gallium oxide (β-Ga 2 O 3 ) based scintillators for high count rate applications. The low-cost rugged β-Ga 2 O 3 scintillators were grown using the optical float zone (FZ) technique. Several dopants and growth atmospheres were used to demonstrate the balance between ultrafast primary decay time and the light yield of the scintillators. Light yields as high as 6446 ± 716 ph/MeV were obtained with 18.3 ns decay time for 662 keV gamma rays. Decay times as fast as 12ns were obtained with a 3212 ± 357 ph/MeV light yield. An excellent 662 keV gamma energy resolution of 7% was obtained using the β-Ga 2 O 3 :Ce crystals. Even with these excellent scintillation properties, the gamma radiation hardness of β-Ga 2 O 3 crystals was better than the leading radiation-hard lead tungstate (PbWO 4 ) crystals. Twenty-six scintillators fabricated from the grown β-Ga 2 O 3 crystals were tested for radiation hardness with a 60 Co gamma irradiation rate of 14 krad/h with a total radiation dose of 2 Mrad. The scintillation properties of these crystals remained unaffected. To date, no other scintillator has demonstrated such high radiation resistance. Furthermore, these FZ-grown low-cost, non-hygroscopic, and high-density β-Ga 2 O 3 scintillators can replace the existing scintillators in many applications ranging from nuclear and high energy physics experiments to nuclear security.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Absolute light yield of the EJ-204 plastic scintillator

The absolute light yield of a scintillator, defined as the number of scintillation photons produced per unit energy deposited, is a useful quantity for scintillator development, research, and applications. Yet, literature data on the absolute light yield of organic scintillators are limited. The goal of this work is to assess the suitability of the EJ-204 plastic scintillator from Eljen Technology to serve as a reference standard for measurements of the absolute light yield of organic scintillators. Four EJ-204 samples were examined: two manufactured approximately four months prior and stored in high-purity nitrogen, and two aged approximately eleven years and stored in ambient air. The scintillator response was measured using a large-area avalanche photodiode calibrated using low energy $γ$-ray and X-ray sources. The product of the quantum efficiency of the photodetector and light collection efficiency of the housing was characterized using an experimentally-benchmarked optical photon simulation. The average absolute light yield of the fresh samples, 9100 ± 400 photons per MeV, is lower than the manufacturer-reported value of 10400 photons per MeV. Moreover, the aged samples demonstrated significantly lower light yields, deviating from the manufacturer specification by as much as 26%. These results are consistent with recent work showcasing environmental aging in plastic scintillators and suggest that experimenters should use caution when deploying plastic scintillators in photon counting applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of the design of thick, segmented scintillators for megavoltage cone-beam CT using a novel, hybrid modeling technique

Purpose: Active matrix flat-panel imagers (AMFPIs) incorporating thick, segmented scintillators have demonstrated order-of-magnitude improvements in detective quantum efficiency (DQE) at radiotherapy energies compared to systems based on conventional phosphor screens. Such improved DQE values facilitate megavoltage cone-beam CT (MV CBCT) imaging at clinically practical doses. However, the MV CBCT performance of such AMFPIs is highly dependent on the design parameters of the scintillators. In this paper, optimization of the design of segmented scintillators was explored using a hybrid modeling technique which encompasses both radiation and optical effects. Methods: Imaging performance in terms of the contrast-to-noise ratio (CNR) and spatial resolution of various hypothetical scintillator designs was examined through a hybrid technique involving Monte Carlo simulation of radiation transport in combination with simulation of optical gain distributions and optical point spread functions. The optical simulations employed optical parameters extracted from a best fit to measurement results reported in a previous investigation of a 1.13 cm thick, 1016μm pitch prototype BGO segmented scintillator. All hypothetical designs employed BGO material with a thickness and element-to-element pitch ranging from 0.5 to 6 cm and from 0.508 to 1.524 mm, respectively. In the CNR study, for each design, full tomographic scans of a contrast phantom incorporating various soft-tissue inserts were simulated at a total dose of 4 cGy. Results: Theoretical values for contrast, noise, and CNR were found to be in close agreement with empirical results from the BGO prototype, strongly supporting the validity of the modeling technique. CNR and spatial resolution for the various scintillator designs demonstrate complex behavior as scintillator thickness and element pitch are varied—with a clear trade-off between these two imaging metrics up to a thickness of ∼3 cm. Based on these results, an optimization map indicating the regions of design that provide a balance between these metrics was obtained. The map shows that, for a given set of optical parameters, scintillator thickness and pixel pitch can be judiciously chosen to maximize performance without resorting to thicker, more costly scintillators. Conclusions: Modeling radiation and optical effects in thick, segmented scintillators through use of a hybrid technique can provide a practical way to gain insight as to how to optimize the performance of such devices in radiotherapy imaging. Assisted by such modeling, the development of practical designs should greatly facilitate low-dose, soft tissue visualization employing MV CBCT imaging in external beam radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward “super-scintillation” with nanomaterials and nanophotonics

Abstract Following the discovery of X-rays, scintillators are commonly used as high-energy radiation sensors in diagnostic medical imaging, high-energy physics, astrophysics, environmental radiation monitoring, and security inspections. Conventional scintillators face intrinsic limitations including a low extraction efficiency of scintillated light and a low emission rate, leading to efficiencies that are less than 10 % for commercial scintillators. Overcoming these limitations will require new materials including scintillating nanomaterials (“nanoscintillators”), as well as new photonic approaches that increase the efficiency of the scintillation process, increase the emission rate of materials, and control the directivity of the scintillated light. In this perspective, we describe emerging nanoscintillating materials and three nanophotonic platforms: (i) plasmonic nanoresonators, (ii) photonic crystals, and (iii) high-Q metasurfaces that could enable high performance scintillators. We further discuss how a combination of nanoscintillators and photonic structures can yield a “super scintillator” enabling ultimate spatio-temporal resolution while enabling a significant boost in the extracted scintillation emission.

Carr Delgado, Hamish↗

Scintillator array for radiation detection

A radiation detector includes a photodetector and a scintillator coupled thereto. The scintillator is formed of a scintillator material comprising an organic glass scintillator (OGS) material and at least one of a polymer additive or a plasticizer additive. The scintillator emits light when radiation is received at the scintillator, and the light is received by the photodetector. The radiation detector can further include a frame that has an interior cavity that holds the scintillator in position with respect to the photodetector, such that the light emitted by the scintillator is transmitted to the photodetector. The scintillator can be formed by casting amorphous scintillator material in the interior cavity of the frame. The frame can then be coupled to the photodetector to form the radiation detector.

Carlson, Joseph↗

Scintillator array for radiation detection

A radiation detector includes a photodetector and a scintillator coupled thereto. The scintillator is formed of a scintillator material comprising an organic glass scintillator (OGS) material and at least one of a polymer additive or a plasticizer additive. The scintillator emits light when radiation is received at the scintillator, and the light is received by the photodetector. The radiation detector can further include a frame that has an interior cavity that holds the scintillator in position with respect to the photodetector, such that the light emitted by the scintillator is transmitted to the photodetector. The scintillator can be formed by casting amorphous scintillator material in the interior cavity of the frame. The frame can then be coupled to the photodetector to form the radiation detector.

Carlson, Joseph↗

Comparative analysis of new crystal and plastic scintillators for fast and thermal neutron detection

This paper considers scintillation and physical properties of efficient organic scintillators tested as single crystals and as components of plastics with pulse shape discrimination (PSD). For the first time, single crystals of 9,9-dimethyl-2-phenyl-9H-fluorene (PhF) were grown for studies of the basic scintillation properties of this new compound. Comparison to classical organic crystals, like anthracene, trans-stilbene, and p-terphenyl, and to more recently introduced organic glass showed that the new crystal belongs to a group of the most efficient scintillators, with light output exceeding that of trans-stilbene and PSD comparable to that of p-terphenyl. Furthermore, additional studies were conducted to evaluate scintillation performance and physical properties, like hardness and dye leaching, of plastic scintillators prepared with PhF, organic glass, and liquid diisopropylnaphthalene (DIPN) that were considered as examples for potential replacement of PPO (2,5-diphenyloxazole) in current commercial PSD plastic scintillators. Comparison of the highest performing plastic scintillators prepared with these dyes shows that PhF formulations produced a record light output (LO) increase of 69 % relative to EJ-200. Similar improvements obtained with 6 Li-loaded formulations showed that future development of PSD plastics should not be limited to use of PPO but must involve the search and exploration of new efficient dyes that may lead to discovery of much brighter organic scintillators with improved physical properties required for fast and thermal neutron detection, fast neutron spectroscopy, and antineutrino detection applications.

9,9-dimethyl-2-phenyl-9H-fluorene↗

Energy dependent response of plastic scintillation detectors to photon radiation of low to medium energy

Purpose: Plastic scintillation detectors are promising candidates for the dosimetry of low- to medium-energy photons but quantitative knowledge of their energy response is a prerequisite for their correct use. The purpose of this study was to characterize the energy dependent response of small scintillation detectors (active volume <1 mm{sup 3}) made from the commonly used plastic scintillator BC400. Methods: Different detectors made from BC400 were calibrated at a number of radiation qualities ranging from 10 to 280 kV and at a {sup 60}Co beam. All calibrations were performed at the Physikalisch-Technische Bundesanstalt, the National Metrology Institute of Germany. The energy response in terms of air kerma, dose to water, and dose to the scintillator was determined. Conversion factors from air kerma to dose to water and to dose to the scintillator were derived from Monte Carlo simulations. In order to quantitatively describe the energy dependence, a semiempirical model known as unimolecular quenching or Birks’ formula was fitted to the data and from this the response to secondary electrons generated within the scintillator material BC400 was derived. Results: The detector energy response in terms of air kerma differs for different scintillator sizes and different detector casings. It is therefore necessary to take attenuation within the scintillator and in the casing into account when deriving the response in terms of dose to water from a calibration in terms of air kerma. The measured energy response in terms of dose to water for BC400 cannot be reproduced by the ratio of mean mass energy-absorption coefficients for polyvinyl toluene to water but shows evidence of quenching. The quenching parameter kB in Birks’ formula was determined to be kB = (12.3 ± 0.9) mg MeV{sup −1} cm{sup −2}. Conclusions: The energy response was quantified relative to the response to {sup 60}Co which is the common radiation quality for the calibration of therapy dosemeters. The observed energy dependence could be well explained with the assumption of ionization quenching as described by Birks’ formula. Plastic scintillation detectors should be calibrated at the same radiation quality that they will be used at and changes of the spectrum within the application need to be considered. The authors results can be used to evaluate the range of validity of a given calibration.

60 APPLIED LIFE SCIENCES↗