A Neutron Activation Gamma Ray Spectrometer for Planetary Surface Analysis
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
A portable neutron spectrometer, nSpec, has been developed for passive interrogation of fast neutrons ( 1 MeV) from neutron sources. The design of the system includes four EJ-301 liquid scintillation cells, a custom stand, and tungsten caps for gamma-ray shielding. Data acquisition settings were optimized to provide a dynamic range of up to > 15 MeV neutron energy. Additionally, the detector response matrix was characterized using a time-of-flight method based on gamma-ray tagged neutron emission from 252 Cf. The spectrum unfolding was characterized using measured and simulated spectra of AmBe and 252 Cf with the GRAVEL and MLEM methods. Monte Carlo methods were used to examine the uncertainty propagation and determine sufficient counts for a measurement.
Fluxes and spectra of electrons and protons in atmosphere measured by spectrometer experiments on Gemini spacecraft
The Cosmic-Ray Veto detector for the muon-to-electron conversion experiment at Fermilab consists of four plastic scintillating counter layers read out by silicon photo-multipliers through embedded wavelength-shifting fibers. In order to increase the light yield in the most critical regions of the Cosmic-Ray Veto detector for improved background rejection, a 1.8 mm diameter fiber is being used in many of the detector's critical modules instead of the previously planned 1.4 mm diameter fiber. This paper reports the testing procedure and light properties of thirty-four 1.8 mm fiber spools, with measurements performed using a custom-built scanner. We compare these new results with previously published data from the 1.4 mm diameter fiber used for regions of the cosmic-ray veto where the increased light yield is not required. In addition, measurements of fiber aging were performed.
For this study, a new characterization of the detector response for the EJ301 liquid scintillator based nSpec system has been conducted at the Los Alamos Neutron Science Center. The new characterization was accomplished in two orders of magnitude less time and with better statistics than the previous characterization. The new and old characterization methods were compared by conducting both types of characterization on two detectors (one EJ301 and one EJ301D). The two methods show consistent results and compare well to results previously published in the literature; however, the results from the characterization of the original nSpec detector show discrepancies that have been identified as being caused by oxygen being absorbed into the detector due to a leak. The new characterized detector response shows improved spectrum unfolding performance than the previous characterization. The cross talk of the detector system was also characterized as a function of incident neutron energy and found to have a negligible impact on spectrum unfolding results. Alternative materials (EJ301D and stilbene) were also characterized in a first step towards an upgraded system. The different materials show little difference in unfolding performance, but the comparison is ongoing. A SiPM based stilbene detector was used to evaluate the use of SiPMs in a future system upgrade. The SiPM provides adequate performance, but the custom SiPM readout results in a much longer pulse width than PMT based systems. The measured light output of the SiPM based stilbene compares well with the results in literature. Future work will look at additional materials (deuterated stilbene and organic glass) and optimizing the SiPM readout to decrease the pulse width.
Deuterated stilbene is an organic scintillator that is a desirable material for fast neutron spectroscopy using spectrum unfolding techniques without requiring time-of-flight information. Due to the crystal structure of the material, some anisotropy of the light output exists, which is dependent on the direction of heavy charged particle recoil relative to the crystal structure. The anisotropy of trans-stilbene (hereafter referred to as stilbene) has been well characterized in previous work, but for deuterated stilbene, the anisotropy has only been partially characterized along the a and b crystal axes, while the artificial c' axis, which shows the largest anisotropy in stilbene, has not been characterized until this publication. Here, in this work, two deuterated stilbene crystals were characterized with neutron energies up to 35 MeV at the Los Alamos Neutron Science Center. For one of the crystals, the response is characterized along the a, b, and c' axes. This characterization shows a distinct anisotropy along the axes in deuterated stilbene, which is very similar to that found in regular stilbene, such that the a axis is the brightest, while the b' and c' axes are approximately 3% and 20%–35% lower relative to the a axis.
The dependence on applied electric field (0–40 kV/cm) of the scintillation light produced by fast electrons and α particles stopped in liquid helium in the temperature range of 0.44 K to 3.12 K is reported. For both types of particles, the reduction in the intensity of the scintillation signal due to the applied field exhibits an apparent temperature dependence. Using an approximate solution of the Debye-Smoluchowski equation, we show that the apparent temperature dependence for electrons can be explained by the time required for geminate pairs to recombine relative to the detector signal integration time. This finding indicates that the spatial distribution of secondary electrons with respect to their geminate partners possesses a heavy, non-Gaussian tail at larger separations and has a dependence on the energy of the primary ionization electron. Here, we discuss the potential application of this result to pulse shape analysis for particle detection and discrimination.
Integral and differential energy spectra of secondary cosmic ray photons between 0.2 and 12 GeV measured with balloon borne lead scintillator sandwich spectrometer
Lunar gamma radiation data measured by Lunik X with scintillation gamma spectrometer
Rapid assay for thymidylate synthetase as specific and sensitive measure of enzyme activity
F layer irregularities transverse scale measurements by two-frequency scintillation-ratio technique yielding 600-700 m scales in auroral zone
Integral tests of evaluated ENDF/B high-energy cross sections have been made by comparing measured and calculated neutron leakage flux spectra from spheres of various materials. An Am-Be (alpha,n) source was used to provide fast neutrons at the center of the test spheres of Be, CH2, Pb, Nb, Mo, Ta, and W. The absolute leakage flux spectra were measured in the energy range 0.5 to 12 MeV using a calibrated NE213 liquid scintillator neutron spectrometer. Absolute calculations of the spectra were made using version 3 ENDF/B cross sections and an S sub n discrete ordinates multigroup transport code. Generally excellent agreement was obtained for Be, CH2, Pb, and Mo, and good agreement was observed for Nb although discrepancies were observed for some energy ranges. Poor comparative results, obtained for Ta and W, are attributed to unsatisfactory nonelastic cross sections. The experimental sphere leakage flux spectra are tabulated and serve as possible benchmarks for these elements against which reevaluated cross sections may be tested.
The activities of cosmogenic isotopes Al-26 and Na-22 in two samples taken from different depths of the lunar regolith core returned by the Luna 16 automatic station were measured by scintillation gamma spectrometer. The measured activities, when recalculated to the time of sampling of the lunar surface material, are: Al-26 - 62 + or - 8 and 54 + or - 9; Na-22 - 42 + or - 8 and 48 + or - 9. Depthwise distributions of the activities of these isotopes in lunar rocks of different types indicate the presence of a considerable depth gradient of activity near the surface caused by the fall off in the fluxes of primary and secondary cosmic radiation. The absence of this gradient in the measured samples, along with data on the tracks and content of inert gases, as well as the granulometric characteristics of the regolith indicate that the surficial layer of the regolith at the sampling site underwent mixing.
Using a scintillation gamma spectrometer with shielding against anticoincidences, the content of the natural radioelements (K, U, and Th) and long-lived cosmogenic radioisotopes (Al-26, Na-22, and Mn-54) in a sample of Sea of Fertility regolith was determined. Based on the content data of natural radioelements, an attempt was made to classify this sample in the scale of petrochemical types of terrestrial rocks arranged in accordance with their silicic content and alkalinity. Within the frame of reference of calcium-uranium systematics of lunar samples, a comparison was made of the K/U ratio obtained for the Sea of Fertility sample with analogous data for other regions of the moon. Also discussed are problems on the depthwise distribution of cosmogenic radioisotopes along the regolith profile.
The inelastic interaction mean free paths lambda of 5, 10, and 15 GeV/c pions were measured by determining the distribution of first interaction locations in a modular tungsten-scintillator ionization spectrometer. In addition to commonly used interaction signatures of a few (2-5) particles in two or three consecutive modules, a chi2 distribution is used to calculate the probability that the first interaction occurred at a specific depth in the spectrometer. This latter technique seems to be more reliable than use of the simpler criteria. No significant dependence of lambda on energy was observed. In tungsten, lambda for pions is 206 plus or minus 6 g/sq cm.
The inelastic-interaction mean free paths (lambda) of 5-, 10-, and 15-GeV/c pions have been measured by determining the distribution of first-interaction locations in a modular tungsten-scintillator ionization spectrometer. In addition to commonly used interaction signatures of a few (2-5) particles in two or three consecutive modules, a chi-squared distribution is employed to calculate the probability that the first interaction occurred at a specific depth in the spectrometer. This latter technique seems to be more reliable than use of the simpler criteria. No significant dependence of lambda on energy has been observed. In tungsten, lambda for pions is 206 (plus or minus 6) g/sq cm.
Source search campaigns involve the measurement of consecutive background gamma-ray spectra obtained with a mobile detector-spectrometer, such as tellurium-doped sodium iodide NaI(Tl) scintillator detector-spectrometer. Counts are measured with NaI(Tl) detector in short acquisition intervals, such as one second. Detection of isotopes in search data is challenging because of the low signal-to-noise ratio (S/N) of the spectral lines and highly varying background due to naturally occurring radioactive material (NORM). In this work, we investigate the performance of the detection of orphan Cs-137, Am-241, and I-131 isotopes in a gamma ray data set obtained in a search survey. Isotopic detection is performed with a Hopfield Neural Network (HNN), which implements an auto-associative memory by matching incoming measurements to the closest one of its memory-stored signature patterns. HNN is trained on examples of spectra of calibrated isotopic sources with well-resolved spectral lines. During testing, HNN processes spectra with partially complete or distorted isotopic lines. The performance of the HNN detection algorithm is benchmarked with Precision, Recall, and F1 scores. Test results demonstrate the potential of HNN to detect the isotope of interest with high accuracy (F1 > 90%) for all isotopes in this study.
This report discusses the quality and performance of currently available PbWO crystals of relevance to high-resolution electromagnetic calorimetry, e.g. detectors for the Neutral Particle Spectrometer at Jefferson Lab or those planned for the Electron–Ion Collider. Since the construction of the Compact Muon Solenoid (CMS) at the Large Hadron Collider (LHC) and early PANDA (The antiProton ANnihilations at DArmstadt) electromagnetic calorimeter (ECAL) the worldwide availability of high quality PbWO 4 production has changed dramatically. We report on our studies of crystal samples from SICCAS/China and CRYTUR/Czech Republic that were produced between 2014 and 2019.