Requirements for Large Eddy Simulation Computations of Variable-Speed Power Turbine Flows

Variable-speed power turbines (VSPTs) operate at low Reynolds numbers and with a wide range of incidence angles. Transition, separation, and the relevant physics leading to them are important to VSPT flow. Higher fidelity tools such as large eddy simulation (LES) may be needed to resolve the flow features necessary for accurate predictive capability and design of such turbines. A survey conducted for this report explores the requirements for such computations. The survey is limited to the simulation of two-dimensional flow cases and endwalls are not included. It suggests that a grid resolution necessary for this type of simulation to accurately represent the physics may be of the order of Delta(x)+=45, Delta(x)+ =2 and Delta(z)+=17. Various subgrid-scale (SGS) models have been used and except for the Smagorinsky model, all seem to perform well and in some instances the simulations worked well without SGS modeling. A method of specifying the inlet conditions such as synthetic eddy modeling (SEM) is necessary to correctly represent the inlet conditions.

Grid↗

A Dynamic Nonlinear Subgrid-Scale Model for Large-Eddy Simulation of Complex Turbulent Flows

We present a new dynamic nonlinear subgrid-scale (SGS) model for large-eddy simulations (LES) and apply it to compute a flow involving pressure gradients, surface curvature and separation, for which data from a direct numerical simulation are available for comparison. The model, inspired by the triple model idea of Bardina et al. (“Improved Turbulence Models Based on Large Eddy Simulation of Homogeneous, Incompressible, Turbulent Flows,” Report No. TF-19, Thermosciences Division, Department of Mechanical Engineering, Stanford University, 1983), includes a Galilean-invariant term called the modified Leonard stress tensor, and two nonlinear terms comprised of the products of the strain-rate and rotation-rate tensors for an improved representation of the subgrid-scale dissipation, backscatter and anisotropy effects. The model does not employ any ad hoc averaging or clipping procedures, and does not require the specification of a characteristic length scale; hence, it naturally avoids the ambiguities associated with defining a proper length scale for anisotropic grids. Results from the wall-resolved LES of flow past a Gaussian bump using the new model demonstrate improved prediction of skin-friction, flow separation, mean flow profiles and turbulent quantities when compared to implicit LES as well as explicit LES using the Vreman SGS model on the same grid.

Turbulence↗

Droop Control-Based Dispatch of an Islanded Microgrid with Multiple Grid-Forming Sources: Preprint

Before rotating fossil-fuel based synchronous generators (SGs) are phased out in line with renewable goals, grid-forming (GFM) inverters are expected to parallel with SGs. Primary droop control allows them share power without communication, however, it is necessary to dispatch GFM inverters and/or SG with desired output power for better energy management (e.g., one GFM inverter needs to charge the battery due to low state-of-the charge). Therefore, this paper develops analytic approach to dispatch GFM inverters and SG with desired output power by shifting the droop intercept up/down while maintain the same frequency operating point for improved transient stability. This concept is demonstrated through pure hardware setup with two off-the-shelf inverters and one diesel generator under islanded microgrid, and we also provide insight on real-world implementation of the proposed concept.

droop control↗

AMOS: Generic Planetary Mission Ops

The spacecraft control community is focusing increasing attention on various forms of architectures. Studies on software architectures and related technologies have been commissioned by DOD programs. The purpose of planning a series of annual workshops is to bring together participants working in the Spacecraft Ground System (SGS) domain. The overall intent of these workshops is to expedite the transition to common consensus-based open software architectures for SGSs.

workshops SGS technologies↗

A comparative TEA of a two-step process using chemical solvents for producing an ultra-sweet natural gas

Here, a comprehensive Techno-Economic Analysis (TEA) was performed to evaluate the economic feasibility of a novel two-step process (TSP) developed in Aspen Plus V12.1 to desulfurize and decarbonize a raw natural gas containing (2 mol% H 2 S and 5 mol% CO 2 ) into an ultra-sweet natural gas containing (1.72 ppmv H 2 S and 4.19 ppmv CO 2 ). The raw natural gas flow rate used in the TSP was 117.74 kg/s at 60 °C and 50 bar. The TSP combines an H 2 S desulfurization step using potassium carbonate (K 2 CO 3 ) and a CO 2 capture step using 3 different chemical solvents, monoethanolamine (MEA), sodium glycinate (SGS), and potassium glycinate (PGS). Both steps employ fixed-bed absorbers packed with Mellapak 250Y structured packing. The hydraulics and mass transfer characteristics for the TSP were calculated, indicating normal operation with higher gas-side (k G ) than liquid-side (k L ) mass transfer coefficients. The TEA of TSP indicated that PGS had the most promising economic feasibility among the 3 solvents as it exhibited the lowest Levelized Cost of CO 2 capture (LCOC) of $\$$47.54/ton.CO 2 at a Capital Expenditure (CAPEX) of $\$$24.98 million, and an Operating Expenditure (OPEX) of $\$$12.20 million/year. Also, the TSP could produce one MMSCF of ultra-sweet natural gas at a total cost of $\$$339.55.

03 NATURAL GAS↗

Development of an innovative process for post-combustion CO 2 capture to produce high-value NaHCO 3 nanomaterials

An innovative post-combustion process using aqueous sodium glycinates solutions (SGS) for CO 2 capture from a split flue gas stream emitted from the 600 MWe coal power plant, used in the Wolverine Clean Energy Venture (WCEV) project, was developed in Aspen Plus v.10. The flue gas flow rate used in the process was 12.43 kg/s (at 353.15 K and 101.33 kPa) and contained 0.0023 and 13.33 mol% of SO 2 and CO 2 , respectively. The overall process includes 5 main units designed to remove all SO 2 and capture more than 90 mol% of CO 2 in the flue gas stream, while producing high-value, salable sodium bicarbonate (NaHCO 3 ) nanomaterials to offset the total process costs. The hydraulics, mass transfer characteristics, and process performance obtained using Aspen Plus were discussed. Also, the capital expenditure (CAPEX), operating expenditure (OPEX), and Levelized cost of CO 2 capture (LCOC) were calculated to assess the feasibility of this process. Further, the hydraulics in the SO 2 washing and CO 2 capture units showed a pressure drop of 12 and 1 kPa, respectively, and the behaviors of the liquid holdup and normalized packing specific wetted surface area were similar in both units. The gas-side mass transfer coefficients were orders of magnitude greater than the liquid-side mass transfer coefficients. The process was able to capture 2.352 kg/s of CO 2 and produce 4.486 kg/s of valuable NaHCO 3 nanomaterials. Also, the calculated CAPEX, OPEX, and LCOC of the process for a 30-year plant lifetime were ($\$ $4,450,552), (233.00 $\$ $/h) and (35.49 $\$ $/ton of CO 2 captured), respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A crisis for the verification and validation of turbulence simulations

Three algorithms have been proposed for solution of the Rayleigh–Taylor turbulent mixing problem. They are based upon three different physical principles governing the Euler equations for fluid flow. The principles serve to select the physically relevant solution from among many nonunique solutions. The admissibility principle is in dispute. The three different algorithms, expressing the three physical admissibility principles can be formulated in terms of the three energy dissipation rates or the entropy production rates, as selected by the size of the sub grid scale coefficients. These have maximal values or less than maximal values. The resulting solutions are markedly different. We find strong validation evidence that supports the maximum rate principle, based on a review of prior results and on new results presented here. We review experimental data used for validation and sufficient to discriminate among the three. We present a new analysis of this data. We show that the hypothesized long wave length perturbations in the initial conditions are not significant, so that validation can be based on this data in a straight forward manner. One of the algorithms is labeled direct numerical simulation, but is not, and as a consequence, the two algorithms with less than maximal SGS coefficients are variants of one another. Finally recommendations for the numerical modeling of the deflagration to detonation transition in type Ia supernova are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Accident event progression, gaps, and key performance indicators for steam generator tube rupture events in water-cooled SMRs: A review

According to historical records of reactor-related incidents, a steam generator tube rupture (SGTR) is one of the most common occurrences at operating pressurized water reactors (PWRs). Such design-basis accidents (DBAs) could lead to a direct path for radionuclides to be released to the atmosphere via the safety and relief valves, making assessments of radionuclide discharge from operating nuclear power plants (NPPs) into the environment crucial for ensuring safety. In such analyses, the primary focus has been on the extent of radioactive release, not the potential damage to the core. Moreover, significant and timely intervention by operators is needed during the initial stages of SGTRs in order to avert overfilling of the SGs, as well as to restrict the dissemination of radioactive materials. Determining the event sequence and phases that occur during an SGTR incident in an advanced passive (e.g., AP1000) water-cooled nuclear reactor is crucial for implementing effective passive safety systems (PSSs) for a specific water-cooled small modular reactor (SMR) design. Here this study provides a comprehensive review of the accident event progression, associated physical phenomena, knowledge gaps, and key performance indicators that must be evaluated and assessed in thermal-hydraulics models, based on relevant test data, respectively.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Statistically Steady State Large-Eddy Simulations Forced by an Idealized GCM: 1. Forcing Framework and Simulation Characteristics

Using large-eddy simulations (LES) systematically has the potential to inform parameterizations of subgrid-scale (SGS) processes in general circulation models (GCMs), such as turbulence, convection, and clouds. Here we show how LES can be run to emulate grid columns of GCMs to generate a library of LES across a cross-section of dynamical regimes. The LES setup replicates the thermodynamic and water budgets in GCM grid columns. Resolved horizontal and vertical transports of heat and water and large-scale pressure gradients from the GCM are prescribed as forcing in the LES. The LES satisfies the same (slab-ocean) surface boundary conditions as the GCM, leaving the LES temperatures free to adjust. Radiative transfer is treated in a unied but highly idealized manner (a semi-gray atmosphere without cloud radiative effects) in both the GCM and LES. We show that the LES with these forcing and boundary conditions reaches statistically steady states without nudging to reference profiles. These steady states provide a training dataset for developing GCM parameterizations. The same LES setup also provides a good basis for studying the cloud response to global warming.

54 ENVIRONMENTAL SCIENCES↗

Small-Signal Stability Support from Dynamically Configurable Grid-Forming/Following Inverters for Distribution Systems

The growth of inverter-based resources (IBRs) in modern power systems can challenge system stability since they do not natively provide inertia, prompting a need to develop new methods to address the potential instabilities. In this paper, a dynamically configurable grid-forming (GFM) and grid-following (GFL) control is proposed, which enables inverters to flexibly transition to support system needs. The operation mode transition between GFM and GFL controls is adopted as an additional degree of control flexibility to adjust the small-signal stability margin. In addition, a holistic and detailed small-signal model for a distribution feeder that captures the dynamics from both synchronous generators (SGs) and IBRs is also derived and used to evaluate the effectiveness of the proposed GFM/GFL controls to augment the system small-signal stability margin. Case studies with varying levels of IBRs were implemented in MATLAB/Simulink to demonstrate the effectiveness of the proposed approach.

grid-following control↗

Quantitative Small-Signal Stability Analysis of Grid-Forming Inverters in Large-Scale Power Systems

In this paper, the challenges induced by the integration of inverter-based resources (IBRs) into existing power systems are discussed. Although the grid-forming (GFM) control has been used to enhance system performance in multiple sections of electric power systems (e.g., transmission and distribution systems, microgrids, among others), the coupling mechanism between GFM inverter and various types of other components in modern power systems should be clearly explored. Existing analyses mainly focus on qualitative investigations that verify the effectiveness of deploying GFM inverters for stability enhancement. A holistic system-level quantitative analysis is still missing to verify the detailed benefits of GFM inverters and their interactions with other generation units (e.g., synchronous generators [SGs], conventional grid-following [GFL] inverters, synchronous condensers, among others). To fill in the technical gaps, a holistic small-signal model of the entire system with both rotating generation units and IBRs is established along with the customized power flow analysis for varying steady-state operating points. Further, a quantitative method is proposed to identify the impacts of GFM inverters on system performance with an emphasis on a quantifiable stability margin and a complete modal analysis at the system level. Finally, a realistic test system is used to verify the proposed approach.

grid-following↗

Structural Impact of Grid-Forming Inverters on Power System Coherency

This paper addresses the following fundamental research question: how does the integration of grid-forming inverters (GFMs) replacing conventional synchronous generators (SGs) impact the slow coherent eigen-structure and the low frequency oscillatory behavior of future power systems? Due to time-scale separated dynamics, generator states inside a coherent area synchronize over a fast time-scale due to stronger coupling, while the areas themselves synchronize over a slower time scale. Our mathematical analysis shows that due to the large-scale integration of GFMs, the weighted Laplacian structure of the frequency dynamics is preserved, however, the entries of the Laplacian may be significantly modified based on the location and penetration levels of the GFMs. This can impact and potentially significantly alter the coherency structure of the system. We have validated our findings with numerical results using the IEEE 68-bus test system.

Mukherjee, Sayak [BATTELLE (PACIFIC NW LAB)]↗

Frequency Shaping Control for Weakly-Coupled Grid-Forming IBRs

Here, we consider the problem of controlling the frequency of low-inertia power systems via inverter-based resources (IBRs) that are weakly connected to the grid. We propose a novel grid-forming control strategy, the so-called frequency shaping control, that aims to shape the frequency response of synchronous generators (SGs) to load perturbations so as to efficiently arrest sudden frequency drops. Our solution relaxes several existing assumptions in the literature and is able to navigate trade-offs between peak power requirements and maximum frequency deviations. Finally, we analyze the robustness to imperfect knowledge of network parameters, while particularly highlighting the importance of accurate estimation of these parameters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coherency-Aware Learning Control of Inverter-Dominated Grids: A Distributed Risk-Constrained Approach

Here, this letter investigates the importance of integrating the coherency knowledge for designing controllers to dampen sustained oscillations in wide-area power networks with significant penetration of inverter-interfaced resources. Coherency is a fundamental property of power systems, where time-scale separation in frequency dynamics leads to clustered behavior among generators of different groups. Large-scale penetration of inverter-driven low inertia resources replacing conventional synchronous generators (SGs) can lead to perturbation in the coherent partitioning; hence, integrating such information is of utmost importance for oscillation control designs. We present the coherency-aware design of a distributed output feedback-based reinforcement learning method that additionally incorporates risk constraints to capture the uncertainties related to net-load fluctuations. The use of domain-aware coherency information has produced improved training and oscillation performance than the coherency-agnostic control design, hence proving to be effective in controller design. Finally, we validated the proposed method with numerical experiments on the benchmark IEEE 68-bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing Frequency Stability Constraint for Unit Commitment Problem Considering High Penetration of Renewables

As zero-carbon electricity systems become the trend of future grid, the system inertia provided by conventional synchronous generators (SGs) keeps decreasing. The resultant lower system inertia will inevitably cause frequency stability problem, especially in the first few seconds following disturbance. To tackle this challenge, this paper proposes a frequency stability constraint for power systems unit commitment problem by considering the fast frequency responses (FFRs) from inverter-based resources (IBRs). Our developed frequency stability constraint is grounded on an analytical frequency nadir estimation framework that considers both SG and IBR dynamics. The accuracy of our frequency nadir estimation framework is validated by most severe N-1 contingency simulation result in a real island system. Then, the adaptive inertia frequency stability constraint is derived by performing sensitivity analysis with our frequency nadir estimation framework. Finally, we demonstrate the effectiveness of our developed frequency stability constraint with one year day-ahead unit commitment results of the island system.

fast frequency response↗

Fault-Tolerant Decentralized Control for Large-Scale Inverter-Based Resources for Active Power Tracking

Integration of inverter-based resources (IBRs) which lack the intrinsic characteristics such as the inertial response of the traditional synchronous-generator (SG)-based sources presents a new challenge in the form of analyzing the grid stability under their presence. While the dynamic composition of IBRs differs from that of the SGs, the control objective remains similar in terms of tracking the desired active power. This letter presents a decentralized primal-dual-based fault-tolerant control framework for the power allocation in IBRs. Overall, a hierarchical control algorithm is developed with a lower level addressing the current control and the parameter estimation for the IBRs and the higher level acting as the reference power generator to the low level based on the desired active power profile. The decentralized network-based algorithm adaptively splits the desired power between the IBRs taking into consideration the health of the IBRs transmission lines. The proposed framework is tested through a simulation on the network of IBRs and the high-level controller performance is compared against the existing framework in the literature. The proposed algorithm shows significant performance improvement in the magnitude of power deviation and settling time to the nominal value under faulty conditions as compared to the algorithm in the literature.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Permitting A Coal-Fired 4-MMt/yr CCS Project in North Dakota, USA

Paper presented at 16th International Conference on Greenhouse Gas Control Technologies (GHGT-16), October 23–27, 2022, Lyon, France. As part of the U.S. Department of Energy’s CarbonSAFE Program, the Energy & Environmental Research Center (EERC), in partnership with Minnkota Power Cooperative, Inc. (Minnkota), conducted commercial-scale site characterization and permitting of two deep saline formations for the geologic storage of anthropogenic CO 2 emissions. Captured as part of Minnkota’s Tundra SGS (secure geologic storage) project, these storage horizons would collectively and permanently store an annual average of 4 million metric tons (MMt) of CO 2 .

20 FOSSIL-FUELED POWER PLANTS↗

Simulating Atmospheric Boundary Layer Turbulence with Nek5000/RS

We present large-eddy-simulation (LES) modeling approaches for the simulation of atmospheric boundary layer turbulence that are of direct relevance to wind energy production. In this report, we study a GABLS benchmark problem using high-order spectral element code Nek5000/RS, which is supported under the DOE’s Exascale Computing Project (ECP) Center for Efficient Exascale Discretizations (CEED) project, targeting application simulations on various acceleration-device based exascale computing platforms [1, 2]. We demonstrate our newly developed subgrid-scale (SGS) models based on high-pass filter (HPF), mean-field eddy viscosity (MFEV), and Smagorinsky (SMG) with no-slip and traction boundary conditions, provided with low-order statistics, convergence and turbulent structure analysis. The model fidelity and scaling performance of Nek5000/RS on DOE’s leadership computing platforms in comparison to those of AMR-Wind, a block-structured second-order finite-volume code with adaptive-mesh-refinement capabilities, are discussed in [3].

17 WIND ENERGY↗