Search NASA⌕ Search

SEARCH · Search NASA

Results for “SHIELDING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A Proposal for Standardized MMOD Shielding for Robotic Spacecraft

NASA robotic spacecraft are required to assess the potential for small debris induced failure for all disposal-critical components. Additional shielding might then be necessary in order to meet the acceptable risk requirement for the overall mission. Traditionally this requirement had been met with little or no additional shielding. Since the introduction of a high density debris population in ORDEM 3.0, some missions, especially those in higher portions of Low Earth Orbit, have needed additional MMOD-specific shielding in order for the mission to meet the requirement. This is a costly design effort when performed late in the project life cycle, which adds unexpected mass to the spacecraft components during the integration phase, and could disrupt thermal management. A proposal is discussed to develop a more cost-effective approach to MMOD-shielding, which can be employed earlier in the hardware design phase. The development and adoption of standardized shielding assemblies allows early tailoring of the shielding around a component, so that the mass is accounted for, as well as the small particle penetration risk, at a point in the design phase when the cost and schedule impact are more manageable. A set of several assemblies can be developed with a range of protection thresholds, in order to control mass where less shielding is needed. Such shielding assemblies would be developed in collaboration with blanket assembly specialists and thermal control engineers to ensure manufacturability and thermal performance challenges are known and acceptable. One clear benefit of such an approach is that hypervelocity testing can be performed on each of the standard shield assemblies to refine and confirm their performance prior to use.The challenges inherent in designing supplemental MMOD shielding will be discussed, including variations in the orbital debris environment and performance prediction. The benefits of a standardized shielding approach and example applications will also be presented.

Hull, Scott M.↗

Adaptive planning using megavoltage fan-beam CT for radiation therapy with testicular shielding

This study highlights the use of adaptive planning to accommodate testicular shielding in helical tomotherapy for malignancies of the proximal thigh. Two cases of young men with large soft tissue sarcomas of the proximal thigh are presented. After multidisciplinary evaluation, preoperative radiation therapy was recommended. Both patients were referred for sperm banking and lead shields were used to minimize testicular dose during radiation therapy. To minimize imaging artifacts, kilovoltage CT (kVCT) treatment planning was conducted without shielding. Generous hypothetical contours were generated on each 'planning scan' to estimate the location of the lead shield and generate a directionally blocked helical tomotherapy plan. To ensure the accuracy of each plan, megavoltage fan-beam CT (MVCT) scans were obtained at the first treatment and adaptive planning was performed to account for lead shield placement. Two important regions of interest in these cases were femurs and femoral heads. During adaptive planning for the first patient, it was observed that the virtual lead shield contour on kVCT planning images was significantly larger than the actual lead shield used for treatment. However, for the second patient, it was noted that the size of the virtual lead shield contoured on the kVCT image was significantly smaller than the actual shield size. Thus, new adaptive plans based on MVCT images were generated and used for treatment. The planning target volume was underdosed up to 2% and had higher maximum doses without adaptive planning. In conclusion, the treatment of the upper thigh, particularly in young men, presents several clinical challenges, including preservation of gonadal function. In such circumstances, adaptive planning using MVCT can ensure accurate dose delivery even in the presence of high-density testicular shields.

61 RADIATION PROTECTION AND DOSIMETRY↗

The effects of low- Z shielding on uranium isotope discrimination using the time-emission profiles of long-lived delayed neutrons

Characteristic radiation signals can often be obscured or distorted by relatively small amounts of shielding, as is the case for highly-enriched uranium (HEU). Methods that can detect and identify special nuclear material (SNM) even in the presence of shielding are therefore of high value in many nuclear security and nonproliferation applications. It has been previously shown that the buildup and decay time profiles of long-lived delayed neutron emission from induced fission are unique and can be used to successfully discriminate between uranium isotopes and infer enrichment without the need for a calibration standard. Because the long-lived delayed neutron precursors exhibit decay times on the order of tens of seconds, their time profiles are not sensitive to the delays associated with scattering or diffusion in shielding materials, which occur on much shorter time scales. The use of capture-based neutron detectors can also mitigate the effects of shielding, because unlike recoil-based detectors, they do not have a low-energy detection threshold, so that neutrons that lose their energy in the shielding are still detectable. In this work, the effects of low-Z shielding on the discrimination of uranium isotopes using delayed neutron time profile measurements are investigated for the first time. Furthermore, the delayed neutron buildup and decay time profiles of polyethylene-shielded HEU and depleted uranium objects are measured using two different capture-gated detector designs. The recorded profiles show good agreement with the shapes predicted from six-group delayed neutron models even with the shielding in place, and the enrichment of the HEU and DU objects was estimated accurately to within 5%. While this method shows potential for discriminating and characterizing extreme cases of enrichment when a moderate amount of shielding is present, simulation results suggest that significant limitations exist for intermediate enrichment levels due to distortions to the delayed neutron time profile caused by neutron reflection in the shielding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Shield Design for the Double-D Coil-Based Wireless Charging System

In this work, magnetic field emission (MFE) of the high-power double-D (DD) coil-based wireless charging system is investigated and a shielding technique is proposed. The MFE pattern produced by the DD coils is significantly different from the MFE of the unipolar (e.g., circular, square, or rectangular) coils, and the traditional aluminum shield does not suppress the MFE from the DD coils. This study shows that a conventional aluminum shield increases the MFE, and a magnetic shield effectively suppresses the MFE of the DD coils. Therefore, a magnetic shield consisting of high-permeability magnetic material, such as ferrites, nanocrystalline, etc., is proposed for the DD pads. The shielding effectiveness of the proposed shield is evaluated through finite element analysis and verified through experiments. An 11 kW DD coil-based wireless charging system was used to test the proposed shielding technique. The experimental results show that a traditional aluminum shield increased the MFE by 29.8%, and the proposed magnetic shield suppressed the MFE by 50.5%.

42 ENGINEERING↗

Challenges and Opportunities Specific to Microreactors: Compact and Light-Weight Shielding During Operation and Transportation

The problem of designing a shield for a mobile microreactor has been addressed. The principal challenges encountered in this endeavor are the dual goals of increasing radiation protection and decreasing weight. It is recognized that these two goals are contradictory. Increasing shielding naturally increases weight. Conversely, decreasing weight naturally calls for decreasing material inventory, including possibly decreasing shield mass. The operational and regulatory drivers for shielding and transportation constraints are identified and summarized. The main constraints pertain to volume, mass, radiation dose, material feasibility and availability, and decommissioning expectations. The latter are limits on residual contamination and dose rates after the reactor is removed. Progress toward solving the challenge of shielding a transportable microreactor is made by considering a tungsten tetraboride (WB4) shell surrounding the reactor vessel. The shield and a generic microreactor were modeled using the MCNP code. It was determined that the presence of a 16-cm-thick WB4 shield reduces the dose equivalent rate during operations to 3.6 mrem/h just outside of a concrete vault and dome and soil berm surrounding the reactor, which is very near the occupational dose rate limits. Without the WB4 layer, the dose rate at the same location outside the berm would be 120 mrem/h. Most importantly, the presence of the WB4 shield substantially protects the surrounding concrete and soil from activation, thus decreasing the duration of administrative control for the site following removal of the reactor from 16 to 3.4 years. At that point, the site may be decommissioned and returned to unrestricted public access. A limitation on the incorporation of a WB4 shield as an intrinsic component of a microreactor is that it results in a design that is transportable only by using the largest road conveyances and that the load would require special permits for transit through the U.S. highway system. New directions for further improvements and possibly more effective solutions to the shielding problem of a mobile microreactor are discussed in the conclusion section.

Microreactor↗

SU-F-T-82: Dosimetric Evaluation of a Shield Used for Hemi-Body Skin Electron Irradiation

Purpose: We had several mycosis fungoides patients with a limited disease to about half of the skin surface. A custom-made plywood shield was used to protect the non-targeted skin region with our total skin electron irradiation (TSEI) technique. We report a dosimetric evaluation for our “hemi-body” skin electron irradiation technique. Methods: The technique is similar to our clinical total skin electron irradiation (TSEI), performed with a six-pair dual field (Stanford technique) at an extended source-to-skin distance (SSD) of 377 cm, with the addition of a plywood shield placed 50 cm from the patient. The shield is made of three layers of standard 5/8″ thick plywood (total thickness of 4.75 cm) that are clamped securely on an adjustable-height stand. Gafchromic EBT3 films were used in assessing the shield’s transmission factor and the extend of the dose penumbra region. To verify the dose delivered for hemi-body skin radiation in a real patient treatment, in-vivo dosimetry using Gafchromic EBT3 films were performed. Film pieces were taped on the patient skin to measure the dose received during the first two fractions, placed on the forehead and upper body (shielded region); and also at the level of pelvic area, left thigh, and left ankle. Results: The shield transmission factor was found to be 10%, and the width of the penumbra (80-to-20% dose fall-off) was about 12 cm. In-vivo dosimetry of a real case confirmed the expected shielded area dose. Conclusion: Hemi-Body skin electron irradiation at an extended SSD is feasible with the addition of a plywood shield at a distance from patient skin. The penumbra dose region and the shield’s transmission factor should be evaluated prior to clinical use. We have treated several hemi-body skin patients with our custom-made plywood shield, the current patient measurements are representative of these for other patients as well.

60 APPLIED LIFE SCIENCES↗

ADVANTG Shielding Analysis for Closure Operations in an Open-Mode Repository

en-mode repository concepts could require worker entry into access drifts after placement of fuel casks in order to perform activities related to backfill, plug emplacement, routine maintenance, or performance confirmation. An ideal emplacement-drift shielding configuration would minimize dose to workers while maximizing airflow through the emplacement drifts. This paper presents a preliminary investigation of the feasibility and effectiveness of radiation shielding concepts that could be employed to facilitate worker operations in an open-mode repository. The repository model for this study includes pressurized-water reactor fuel assemblies (60 GWd/MTU burnup, 40 year post-irradiation cooldown) in packages of 32 assemblies. The closest fuel packages are 5 meters from dosimetry voxels in the access drift. The unshielded dose to workers in the access drift is 73.7 rem/hour. Prior work suggests that open-mode repository concepts similar to this one would require 15 m3/s of ventilation airflow. Shielding concepts considered here include partial concrete plugs, labyrinthine shields, and stainless steel photon attenuator grids. Maximum dose to workers in the access drift was estimated for each shielding concept using MCNP5 with variance reduction parameters generated by ADVANTG. Because airflow through the shielding is important for open-mode repositories, a semi-empirical estimate of the head loss due to each shielding configuration was also calculated. Airflow and shielding performance vary widely among the proposed shielding configurations. Although the partial plug configuration had the best airflow performance, it allowed dose rates 1500 greater than the specified target. Labyrinthine shielding concepts yield doses on the order of 1 mrem/hour with configurations that impose 3 to 11 J/kg head loss. Adding 1 cm lead lining to the airflow channels of labyrinthine designs further reduces the worker dose by 65% to 95%. Photon-attenuator concepts may reduce worker dose to as low as 29 mrem/hour with head loss on the order of 1.9 J/kg.

advantg↗

An experimental investigation of reducing advanced turboprop cabin noise by wing shielding

An experimental investigation was undertaken to determine if wing shielding could reduce the noise impacting the fuselage of an advanced turboprop airplane. Four wings were tested behind two eight-bladed propeller models. Significant shielding of the propeller noise was observed and a particular wing-propeller geometry was identified to provide the most shielding. Specifically, an up-inboard rotation would be needed for a low-wing airplane and a down-inboard rotation for a high-wing airplane. As the axial Mach number was increased, the position where the shielding starts moved farther downstream. This shift in the start of shielding was roughly a straight line with respect to Mach number between M = 0.7 and M = 0.8. At M = 0.85 the start of shielding does not shift any farther downstream. A simple barrier noise-reduction model gave the same trends with transducer positions as did the data, and, if corrected for Mach number shift, the model might be used to provide estimates of the wing shielding. Besides providing a barrier to the noise reaching the shielded area, the wing also reflects some of the noise back onto the unshielded area. This can make the noise difference between the unshielded and shielded areas of the fuselage larger than would be expected by simple wind shielding.

Dittmar, J. H.↗

An experimental investigation of reducing advanced turboprop cabin noise by wing shielding

An experimental investigation was undertaken to determine if wing shielding could reduce the noise impacting the fuselage of an advanced turboprop airplane. Four wings were tested behind two eight-bladed propeller models. Significant shielding of the propeller noise was observed and a particular wing-propeller geometry was identified to provide the most shielding. Specifically, an up-inboard rotation would be needed for a low-wing airplane and a down-inboard rotation for a high-wing airplane. As the axial Mach number was increased, the position where the shielding starts moved farther downstream. This shift in the start of shielding was roughly a straight line with respect to Mach number between M = 0.7 and M = 0.8. At M = 0.85 the start of shielding does not shift any farther downstream. A simple barrier noise-reduction model gave the same trends with transducer positions as did the data, and, if corrected for Mach number shift, the model might be used to provide estimates of the wing shielding. Besides providing a barrier to the noise reaching the shielded area, the wing also reflects some of the noise back onto the unshielded area. This can make the noise difference between the unshielded and shielded areas of the fuselage larger than would be expected by simple wind shielding.

Dittmar, J. H.↗

EMI Shields made from intercalated graphite composites

Electromagnetic interference (EMI) shielding typically makes up about twenty percent of the mass of a spacecraft power system. Graphite fiber/polymer composites have significantly lower densities and higher strengths than aluminum, the present material of choice for EMI shields, but they lack the electrical conductivity that enables acceptable shielding effectiveness. Bromine intercalated pitch-based graphite/epoxy composites have conductivities fifty times higher than conventional structural graphite fibers. Calculations are presented which indicate that EMI shields made from such composites can have sufficient shielding at less than 20% of the mass of conventional aluminum shields. EMI shields provide many functions other than EMI shielding including physical protection, thermal management, and shielding from ionizing radiation. Intercalated graphite composites perform well in these areas also. Mechanically, they have much higher specific strength and modulus than aluminum. They also have shorter half thicknesses for x-rays and gamma radiation than aluminum. Thermally, they distribute infra-red radiation by absorbing and re-radiating it rather than concentrating it by reflection as aluminum does. The prospects for intercalated graphite fiber/polymer composites for EMI shielding are encouraging.

Gaier, James R.↗

GCR Transport in the Brain: Assessment of Self-Shielding, Columnar Damage, and Nuclear Reactions on Cell Inactivation Rates

Radiation shield design is driven by the need to limit radiation risks while optimizing risk reduction with launch mass/expense penalties. Both limitation and optimization objectives require the development of accurate and complete means for evaluating the effectiveness of various shield materials and body-self shielding. For galactic cosmic rays (GCR), biophysical response models indicate that track structure effects lead to substantially different assessments of shielding effectiveness relative to assessments based on LET-dependent quality factors. Methods for assessing risk to the central nervous system (CNS) from heavy ions are poorly understood at this time. High-energy and charge (HZE) ion can produce tissue events resulting in damage to clusters of cells in a columnar fashion, especially for stopping heavy ions. Grahn (1973) and Todd (1986) have discussed a microlesion concept or model of stochastic tissue events in analyzing damage from HZE's. Some tissues, including the CNS, maybe sensitive to microlesion's or stochastic tissue events in a manner not illuminated by either conventional dosimetry or fluence-based risk factors. HZE ions may also produce important lateral damage to adjacent cells. Fluences of high-energy proton and alpha particles in the GCR are many times higher than HZE ions. Behind spacecraft and body self-shielding the ratio of protons, alpha particles, and neutrons to HZE ions increases several-fold from free-space values. Models of GCR damage behind shielding have placed large concern on the role of target fragments produced from tissue atoms. The self-shielding of the brain reduces the number of heavy ions reaching the interior regions by a large amount and the remaining light particle environment (protons, neutrons, deuterons. and alpha particles) may be the greatest concern. Tracks of high-energy proton produce nuclear reactions in tissue, which can deposit doses of more than 1 Gv within 5 - 10 cell layers. Information on rates of cell killing from GCR, including patterns of cell killing from single particle tracks. can provide useful information on expected differences between proton and HZE tracks and clinical experiences with photon irradiation. To model effects on cells in the brain, it is important that transport models accurately describe changes in the GCR due to interactions in the cranium and proximate tissues. We describe calculations of the attenuated GCR particle fluxes at three dose-points in the brain and associated patterns of cell killing using biophysical models. The effects of the brain self-shielding and bone-tissue interface of the skull in modulating the GCR environment are considered. For each brain dose-point, the mass distribution in the surrounding 4(pi) solid angle is characterized using the CAM model to trace 512 rays. The CAM model describes the self-shielding by converting the tissue distribution to mass-equivalent aluminum, and nominal values of spacecraft shielding is considered. Particle transport is performed with the proton, neutron, and heavy-ion transport code HZETRN with the nuclear fragmentation model QMSFRG. The distribution of cells killed along the path of individual GCR ions is modeled using in vitro cell inactivation data for cells with varying sensitivity. Monte Carlo simulations of arrays of inactivated cells are considered for protons and heavy ions and used to describe the absolute number of cell killing events of various magnitude in the brain from the GCR. Included are simulations of positions of inactivated cells from stopping heavy ions and nuclear stars produced by high-energy ions most importantly, protons and neutrons.

Shavers, M. R.↗

Performance of Whipple Shields at Impact Velocities above 9 km/s

Whipple shields were first proposed as a means of protecting spacecraft from the impact of micrometeoroids in 1947 [1] and are currently in use as micrometeoroid and orbital debris shields on modern spacecraft. In the intervening years, the function of the thin bumper used to shatter or melt threatening particles has been augmented and enhanced by the use of various types and configurations of intermediate layers of various materials. All shield designs serve to minimize the threat of a spall failure or perforation of the main wall of the spacecraft as a result of the impact of the fragments. With increasing use of Whipple shields, various ballistic limit equations (BLEs) for guiding the design and estimating the performance of shield systems have been developed. Perhaps the best known and most used are the "new" modified Cour-Palais (Christiansen) equations [2]. These equations address the three phases of impact: (1) ballistic (<3 km/s), where the projectile is moving too slowly to fragment and essentially penetrates as an intact projectile; (2) shatter (3 to 7 km/s), where the projectile fragments at impact and forms an expanding cloud of debris fragments; and (3) melt/vaporization (>7 km/s), where the projectile melts or vaporizes at impact. The performance of Whipple shields and the adequacy of the BLEs have been examined for the first two phases using the results of impact tests obtained from two-stage, light-gas gun test firings. Shield performance and the adequacy of the BLEs has not been evaluated in the melt/vaporization phase until now because of the limitations of launchers used to accelerate projectiles with controlled properties to velocities above 7.5 km/s. A three-stage, light-gas gun, developed at the University of Dayton Research Institute (UDRI) [3], is capable of launching small, aluminum spheres to velocities above 9 km/s. This launcher was used to evaluate the ballistic performance of two Whipple shield systems, various thermal protection system materials, and other spacecraft-related materials to the impact of 1.6-mm- to 2.6-mm-diameter, 2017-T4 aluminum spheres at impact velocities ranging from 8.91 km/s to 9.28 km/s. Test results, details of the shield systems, and nominal ballistic limits for the two Whipple shields are shown in Figures 1 and 2.

Christiansen, Eric L.↗

Radiation Shielding of Lunar Regolith/Polyethylene Composites and Lunar Regolith/Water Mixtures

Space radiation is a complex mixed field of ionizing radiation that can pose hazardous risks to sophisticated electronics and humans. Mission planning for lunar exploration and long duration habitat construction will face tremendous challenges of shielding against various types of space radiation in an attempt to minimize the detrimental effects it may have on materials, electronics, and humans. In late 2009, the Lunar Crater Observation and Sensing Satellite (LCROSS) discovered that water content in lunar regolith found in certain areas on the moon can be up to 5.6 +/-2.8 weight percent (wt%) [A. Colaprete, et. al., Science, Vol. 330, 463 (2010). ]. In this work, shielding studies were performed utilizing ultra high molecular weight polyethylene (UHMWPE) and aluminum, both being standard space shielding materials, simulated lunar regolith/ polyethylene composites, and simulated lunar regolith mixed with UHMWPE particles and water. Based on the LCROSS findings, radiation shielding experiments were conducted to test for shielding efficiency of regolith/UHMWPE/water mixtures with various percentages of water to compare relative shielding characteristics of these materials. One set of radiation studies were performed using the proton synchrotron at the Loma Linda Medical University where high energy protons similar to those found on the surface of the moon can be generated. A similar experimental protocol was also used at a high energy spalation neutron source at Los Alamos Neutron Science Center (LANSCE). These experiments studied the shielding efficiency against secondary neutrons, another major component of space radiation field. In both the proton and neutron studies, shielding efficiency was determined by utilizing a tissue equivalent proportional counter (TEPC) behind various thicknesses of shielding composite panels or mixture materials. Preliminary results from these studies indicated that adding 2 wt% water to regolith particles could increase shielding of the regolith materials by about 6%. The findings may be utilized to extend the possibilities of potential candidate materials for lunar habitat structures, will potentially impact the design criteria of future human bases on the moon, and provide some guidelines for future space mission planning with respect to radiation exposure and risks posed on astronauts.

Johnson, Quincy F.↗

Flexible Shields for Protecting Spacecraft Against Debris

A report presents the concept of Flexshield a class of versatile, lightweight, flexible shields for protecting spacecraft against impacts by small meteors and orbiting debris. The Flexshield concept incorporates elements of, but goes beyond, prior spacecraft-shielding concepts, including those of Whipple shields and, more recently, multi-shock shields and multi-shock blankets. A shield of the Flexshield type includes multiple outer layers (called bumpers in the art) made, variously, of advanced ceramic and/or polymeric fibers spaced apart from each other by a lightweight foam. As in prior such shields, the bumpers serve to shock an impinging hypervelocity particle, causing it to disintegrate vaporize, and spread out over a larger area so that it can be stopped by an innermost layer (back sheet). The flexibility of the fabric layers and compressibility of the foam make it possible to compress and fold the shield for transport, then deploy the shield for use. The shield can be attached to a spacecraft by use of snaps, hook-and-pile patches, or other devices. The shield can also contain multilayer insulation material, so that it provides some thermal protection in addition to mechanical protection.

Christiansen, Eric L.↗

Hot Cell Window Shielding Analysis Using MCNP

The Idaho National Laboratory Materials and Fuels Complex nuclear facilities are undergoing a documented safety analysis upgrade. In conjunction with the upgrade effort, shielding analysis of the Fuel Conditioning Facility (FCF) hot cell windows has been conducted. This paper describes the shielding analysis methodology. Each 4-ft thick window uses nine glass slabs, an oil film between the slabs, numerous steel plates, and packed lead wool. Operations in the hot cell center on used nuclear fuel (UNF) processing. Prior to the shielding analysis, shield testing with a gamma ray source was conducted, and the windows were found to be very effective gamma shields. Despite these results, because the glass contained significant amounts of lead and little neutron absorbing material, some doubt lingered regarding the effectiveness of the windows in neutron shielding situations, such as during an accidental criticality. MCNP was selected as an analysis tool because it could model complicated geometry, and it could track gamma and neutron radiation. A bounding criticality source was developed based on the composition of the UNF. Additionally, a bounding gamma source was developed based on the fission product content of the UNF. Modeling the windows required field inspections and detailed examination of drawings and material specifications. Consistent with the shield testing results, MCNP results demonstrated that the shielding was very effective with respect to gamma radiation, and in addition, the analysis demonstrated that the shielding was also very effective during an accidental criticality.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Structural Design and Thermal Analysis for Thermal Shields of the MICE Coupling Magnets

A superconducting coupling magnet made from copper matrix NbTi conductors operating at 4 K will be used in the Muon Ionization Cooling Experiment (MICE) to produce up to 2.6 T on the magnet centerline to keep the muon beam within the thin RF cavity indows. The coupling magnet is to be cooled by two cryocoolers with a total cooling capacity of 3 W at 4.2 K. In order to keep a certain operating temperature margin, the most important is to reduce the heat leakage imposed on cold surfaces of coil cold mass assembly. An ntermediate temperature shield system placed between the coupling coil and warm vacuum chamber is adopted. The shield system consists of upper neck shield, main shields, flexible connections and eight supports, which is to be cooled by the first stage cold heads of two ryocoolers with cooling capacity of 55 W at 60 K each. The maximum temperature difference on the shields should be less than 20 K, so the thermal analyses for the shields with different thicknesses, materials, flexible connections for shields' cooling and structure design for heir supports were carried out. 1100 Al is finally adopted and the maximum temperature difference is around 15 K with 4 mm shield thickness. The paper is to present detailed analyses on the shield system design.

42 ENGINEERING↗

The Simons Observatory: Magnetic Shielding Measurements for the Universal Multiplexing Module

The Simons Observatory (SO) includes four telescopes that will measure the temperature and polarization of the cosmic microwave background using over 60,000 highly sensitive transition-edge bolometers (TES). These multichroic TES bolometers are read out by a microwave RF SQUID multiplexing system with a multiplexing factor of 910. Given that both TESes and SQUIDs are susceptible to magnetic field pickup and that it is hard to predict how they will respond to such fields, it is important to characterize the magnetic response of these systems empirically. This information can then be used to limit spurious signals by informing magnetic shielding designs for the detectors and readout. This paper focuses on measurements of magnetic pickup with different magnetic shielding configurations for the SO universal multiplexing module (UMM), which contains the SQUIDs, associated resonators, and TES bias circuit. The magnetic pickup of a prototype UMM was tested under three shielding configurations: no shielding (copper packaging), aluminum packaging for the UMM, and a tin/lead-plated shield surrounding the entire dilution refrigerator 100 mK cold stage. We also present measurements of the pickup in the UMM when aluminum feedhorns are installed. The measurements show that the aluminum packaging outperforms the copper packaging by a shielding factor of 8-10, and adding the tin/lead-plated 1K shield further increases the relative shielding factor in the aluminum configuration by 1-2 orders of magnitude. Furthermore, the addition of feedhorns provides a factor of 30 improvement when the tin/lead shield is not installed and a factor of 5 improvement when it is.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Flexible 3D printed silicones for gamma and neutron radiation shielding

Here, resin formulations for direct ink write (DIW) additive manufacturing (AM) were developed for facile customization to shield radiation signatures consisting of a range of gamma radiation and neutron energies in a variety of applications. The resin developed in this work has been formulated to accommodate very high loadings of shielding filler materials: up to 40 wt% bismuth (Bi) metal for gamma radiation shielding, and up to 60 wt% boron-10 ( 10 B) metal for neutron shielding. We report the first instance of a printable resin containing 60 wt% 10 B, which remains flexible after curing despite the high solids content. We demonstrate that these resins can not only tolerate formulation modulation for radiation profile-matched shielding, but they can also be printed in a variety of geometries such that mechanical properties of the printed shield are readily tuned to specific applications. In contrast, most existing shielding materials are rigid, bulky, and do not allow for the complex shapes and mechanical flexibility needed in high-usage applications. This work demonstrates the successful development of a tunable resin for additively manufactured, flexible radiation shielding material, containing high loadings of shielding filler, which can be utilized in harsh radiation environments associated with nuclear materials.

61 RADIATION PROTECTION AND DOSIMETRY↗