Search NASA⌕ Search

SEARCH · Search NASA

Results for “STRESS MEASUREMENT, X-RAY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Using X-ray radiography to study oxygen flow in a proton exchange membrane electrolyzer operating under balanced pressure conditions

Of the various water electrolyzer technologies, the proton exchange membrane electrolyzer (PEMWE) is one of the best solutions for producing clean hydrogen without releasing CO 2 . In order to allow for widespread use of clean hydrogen, it is necessary to decrease its cost, which is intrinsically related to system operation. Current PEMWE plants operate in differential mode, directly pressurizing hydrogen and benefiting from thermodynamic compression, which increases overall system efficiency. However, high differential pressure above 30 bar can cause membrane stress, resulting in membrane creeping and failure. Pressurizing the water and operating at balanced pressure allows hydrogen to be produced at higher pressures while preserving the integrity of the membrane and porous layers. Nevertheless, the impact of pressurizing water on PEMWE performance must be better understood to maximize performance under balanced pressure conditions. Here, this study examined the impact of water pressure on two-phase flow. A high-pressure electrolyzer setup was developed to perform operando X-ray radiography and examine oxygen transport with high temporal resolution. The imaging segmentation process, developed to capture bubble properties in the channel, was applied to a specific experiment. The results clearly showed that as pressure increased up to 30 bars, the initial bubbly flow transitioned to slug flow, which led to channel saturation with oxygen. This work demonstrates that two-phase flow in an electrolyzer can be studied using X-ray radiography, which has the advantages of fast measurements and the ability to probe dense materials, such as those required for pressurized electrolyzers.

Balanced high pressure operation↗

Combining synchrotron X-ray diffraction, mechanistic modeling and machine learning for in situ subsurface temperature quantification during laser melting

Laser melting, such as that encountered during additive manufacturing, produces extreme gradients of temperature in both space and time, which in turn influence microstructural development in the material. Qualification and model validation of the process itself and the resulting material necessitate the ability to characterize these temperature fields. However, well established means to directly probe the material temperature below the surface of an alloy while it is being processed are limited. To address this gap in characterization capabilities, a novel means is presented to extract subsurface temperature-distribution metrics, with uncertainty, from in situ synchrotron X-ray diffraction measurements to provide quantitative temperature evolution data during laser melting. Temperature-distribution metrics are determined using Gaussian process regression supervised machine-learning surrogate models trained with a combination of mechanistic modeling (heat transfer and fluid flow) and X-ray diffraction simulation. The trained surrogate model uncertainties are found to range from 5 to 15% depending on the metric and current temperature. The surrogate models are then applied to experimental data to extract temperature metrics from an Inconel 625 nickel superalloy wall specimen during laser melting. The maximum temperatures of the solid phase in the diffraction volume through melting and cooling are found to reach the solidus temperature as expected, with the mean and minimum temperatures found to be several hundred degrees less. The extracted temperature metrics near melting are determined to be more accurate because of the lower relative levels of mechanical elastic strains. However, uncertainties for temperature metrics during cooling are increased due to the effects of thermomechanical stress.

36 MATERIALS SCIENCE↗

Plating and Stripping of Lithium Metal Stabilized by a Block Copolymer Electrolyte: Local Current Density Measurement and Modeling

Here, plating and stripping of lithium protrusions in lithium metal symmetric cells containing a solid block copolymer electrolyte was studied as a function of time in 3D using time-resolved X-ray tomography. These measurements enabled determination of the spatial variation in current densities at the plating and stripping electrodes. The initial interelectrode distance was 27 μm. Correlation functions were calculated to reveal the relationships between current densities at the two electrodes and local electrolyte thickness. Current densities at opposing electrode locations during protrusion growth is uncorrelated until the local interelectrode distance decreases to less than 6 μm, just before the cell shorts. Mass balance was used to determine the area from which lithium ions that form a protrusion were stripped. Computational modeling of the plating and stripping process reveals the interplay between electrochemical and mechanical driving forces and their effect on nonuniform current distribution. Model predictions were compared with experiments without resorting to any adjustable parameters. The computed correlation functions were in qualitative agreement with experiments. Finally, the model was used to calculate contour plots of electrochemical potential within the electrolyte, shedding light on how geometry, salt concentration, interelectrode distance, and mechanical stress influence local rates of electrochemical reaction.

36 MATERIALS SCIENCE↗

Investigation of Nanoparticle Degradation in Hydrogen Fuel Cell Systems through Automated Electron Microscopy

Proton exchange membrane fuel cells (PEMFC) are promising devices for the deployment of hydrogen-powered heavy-duty vehicles, providing a higher efficiency for similar driving range and fueling time than the existing ones. However, PEMFCs still encounter durability challenges mainly due to catalyst degradation in the cathode. Mitigating these performance losses requires a better understanding of the degradation mechanisms under heavy-duty accelerated stress tests (ASTs) [1]. Scanning transmission electron microscopy (STEM) combined with energy dispersive X-ray spectroscopy (EDS) are key tools for the analysis of Pt and PtCo nanoparticle size, spatial distribution and composition [2]. Electron tomography is also used to determine the rate and type of degradation of catalyst nanoparticles as a function of their position on the carbon support. In this work, automated data acquisition software, paired with a custom Python code, have been used to study the effect of different accelerated stress tests (ASTs) on nanoparticle coarsening [2]. Figure 1 shows high-angle annular dark-field (HAADF)-STEM images and EDS maps comparing the cathodes of membrane electrode assemblies (MEAs) following an electrocatalyst AST performed under H2/N2 with that of the heavy-duty AST performed under H2/air. We will discuss how AST conditions affect considerably the spatial distribution of the nanoparticles across the electrode between the membrane and microporous layer. Although the median particle size increased more in the MEA aged under the heavy-duty AST, as determined using a high-throughput image analysis, the quantitative EDS measurements demonstrate that the electrocatalyst AST resulted in more Pt and Co dissolution from the cathode, which is another important indicator of electrocatalyst degradation. We will further present the impact of the relative humidity (% RH) on the degradation mechanisms demonstrated using the same approach. Electron tomography has been used to distinguish the Pt nanoparticles residing on the carbon support surface (exterior) from those within the pore structure (interior) in order to determine the relative stability of interior and exterior nanoparticles. As shown in Figure 2, we will compare the Pt catalyst particle size at the beginning of test (BOT) and end of test (EOT), and discuss the importance of automating the electron tomography workflow, i.e. acquisition, reconstruction, and visualization, to increase sampling and determine the standard deviation of these measurement. The outlook for utilizing low-dose cryo-tomography for limiting damage to the catalyst, support, and especially proton-conducting ionomer will also be discussed [3].

Amichi, Lynda↗

Microstructural and rheological training and memory of nanocolloidal soft glasses under cyclic shear

An intrinsic feature of disordered and out-of-equilibrium materials, such as glasses, is the dependence of their properties on their history. An important example is rheological memory, in which disordered solids obtain properties based on their deformation history. Here, in this study, we employ x-ray photon correlation spectroscopy with in situ rheometry to characterize memory formation in a nanocolloidal soft glass due to cyclic shear. During a cycle, particles undergo irreversible displacements composed of a combination of shear-induced diffusion and heterogeneous, residual strain fields. At lower shear amplitudes, the displacements resemble a random walk in which the directions in each cycle are independent of those in preceding cycles, while at high amplitude, the irreversible displacements in consecutive cycles become correlated. The magnitudes of the displacements decrease with each cycle before reaching a steady state where the microstructure has been trained to achieve enhanced reversibility even at shear amplitudes well above yielding and despite the presence of thermal fluctuations. At amplitudes below and near yielding, these decreases are monotonic, while well above yielding, they are nonmonotonic, suggesting evidence of shear banding. Accompanying this microstructural training are corresponding decreases in the dissipation during each cycle and the magnitude of the residual stress toward steady-state values. Memory of the training is revealed by measurements in which the amplitude of the shear is changed after steady state is reached. The magnitude of the particle displacements, as well as the dissipation and the change in residual stress, vary nonmonotonically with the new shear amplitude, having minima near the training amplitude, thereby revealing correlated microscopic and macroscopic signatures of memory.

Chen, Yihao [Johns Hopkins Univ., Baltimore, MD (U↗

Four-dimensional microstructurally small fatigue crack growth in cyclically loaded nickel superalloy specimen

Here, we nondestructively image a low-solvus high refractory (LSHR) nickel base specimen microstructure during cyclic loading to characterize crack propagation during the microstructurally small crack (MSC) growth regime. Micro-computed tomography (uCT) is used to characterize the material density and identify crack interfaces, while high-energy diffraction microscopy (HEDM) provides snapshots of the microstructural orientation field changes. From these measurements, data are computationally reconstructed and coregistered to describe the specimen’s configuration before load, before crack nucleation, and throughout the crack propagation/loading process. An MSC forms at a FIB-cut notch, which was previously placed to concentrate stress at the center of the specimen gauge, and propagates along a facet parallel to the local {1 1 1} crystallographic plane. Analysis of available crystallographic slip directions and measured point-to-point disorientation axes indicate probable single and coplanar slip activity along FCC octahedral planes within this region. Similar analyses of other crack propagation facets reveal generally slower growth along directions favoring zig-zag cross and codirectional cross slip, which are often disfavored at room temperature.

36 MATERIALS SCIENCE↗

Aligned Conjugated Polymer Nanofiber Networks in an Elastomer Matrix for High-Performance Printed Stretchable Electronics

Conjugated polymer films are promising in wearable X-ray detection. However, achieving optimal film microstructure possessing good electrical and detection performance under large deformation via scalable printing remains challenging. Herein, we report bar-coated high-performance stretchable films based on a conjugated polymer P(TDPP-Se) and elastomer SEBS blend by optimizing the solution-processing conditions. The moderate preaggregation in solution and prolonged growth dynamics from a solvent mixture with limited dissolving capacity is critical to forming aligned P(TDPP-Se) chains/crystalline nanofibers in the SEBS phase with enhanced π–π stacking for charge transport and stress dissipation. The film shows a large elongation at break of >400% and high mobilities of 5.29 cm 2 V –1 s –1 at 0% strain and 1.66 cm 2 V –1 s –1 over 500 stretch–release cycles at 50% strain, enabling good X-ray imaging with a high sensitivity of 1501.52 μC Gy air –1 cm –2 . Finally, our work provides a morphology control strategy toward high-performance conjugated polymer film-based stretchable electronics.

36 MATERIALS SCIENCE↗

Coregistered positron emission particle tracking (PEPT) and X-ray computed tomography (CT) for engineering flow measurements

Increasingly, fully 3D experimental measurements of flow in complex engineering geometries are required to validate computational fluid dynamics models that support and inform reactor design and licensing. One barrier to such measurements is the complexity of typical reactor components and subsequent lack of optical access in these systems. To overcome this, the deployment of coregistered positron emission particle tracking (PEPT) and X-ray computed tomography (CT) is explored for flow measurement in reactor thermal hydraulic components and model (scaled) systems. Through this methodology, fully 3D flow information (via PEPT) and detailed internal geometry (via CT) are captured in opaque systems such as pipes, rod bundles, packed beds, etc. The reconstructed flow field and geometry can then be overlain to reveal detailed flow features around internal structures within a given test section. This is enabled through the use of a combined preclinical PET/CT scanner with overlapping PET and CT fields of view. Such measurements are useful for characterizing flow inside such intricate nuclear thermal hydraulic components as core geometries and heat exchangers, among others, and providing valuable 3D validation data for CFD models. In this work, basic tests of this 3D flow/geometry mapping are presented, and the implications of such measurements are discussed. Further, preliminary measurements are made with both point sources and flow in a simple pipe flow geometry to evaluate the capabilities of this technique. PEPT and CT features are coregistered with up to 0.1 mm precision, and pipe flow mean velocity and Reynolds stresses are reconstructed with similar accuracy to previous PEPT demonstrations. The utility of PEPT/CT is shown herein, and suggestions for future measurements are made.

3D flow measurement↗

Phase Transformations Driving Biaxial Stress Reduction During Wake-Up of Ferroelectric Hafnium Zirconium Oxide Thin Films

Biaxial stress is identified to play an important role in the polar orthorhombic phase stability in hafnium oxide-based ferroelectric thin films. However, the stress state during various stages of wake-up has not yet been quantified. In this work, the stress evolution with field cycling in hafnium zirconium oxide capacitors is evaluated. The remanent polarization of a 20 nm thick hafnium zirconium oxide thin film increases from 9.80 to 15.0 µC cm –2 following 10 6 field cycles. This increase in remanent polarization is accompanied by a decrease in relative permittivity that indicates that a phase transformation has occurred. The presence of a phase transformation is supported by nano-Fourier transform infrared spectroscopy measurements and scanning transmission electron microscopy that show an increase in ferroelectric phase content following wake-up. The stress of individual devices field cycled between pristine and 10 6 cycles is quantified using the sin 2 (ψ) technique, and the biaxial stress is observed to decrease from 4.3 ± 0.2 to 3.2 ± 0.3 GPa. The decrease in stress is attributed, in part, to a phase transformation from the antipolar Pbca phase to the ferroelectric Pca2 1 phase. This work provides new insight into the mechanisms controlling and/or accompanying polarization wake-up in hafnium oxide-based ferroelectrics.

36 MATERIALS SCIENCE↗

Multimodal Defect Imaging of Pure Tungsten Components Fabricated via Electron Beam Powder Bed Fusion

The utilization of additive manufacturing (AM) techniques for refractory materials in high-temperature environments has significantly expanded because of the ability to fabricate geometrically complex components. Electron beam powder bed fusion (EB-PBF), which provides lower residual stress, a cleaner vacuum environment, and better efficiency for high melting point, is one of the best-suited AM methods to produce advanced refractory components. However, the property variation attributed to the heterogeneous microstructure and process-induced defects has hindered the widespread adoption of EB-PBF-produced material like tungsten. While numerous in-situ monitoring and defect detection methods have been demonstrated for EB-PBF, a workflow that compares and evaluates process-induced abnormalities from different imaging perspectives is still limited. This study examines a feature-embedded tungsten component manufactured via the EB-PBF process to demonstrate the defect detection capabilities of a multimodal defect imaging workflow. The predefined and process-induced defects are evaluated by harnessing various imaging techniques, including in-situ electron imaging, layerwise near-infrared (NIR) imaging, post-build high-energy x-ray computed tomography (CT), and conventional destructive metallography. The results highlight the strengths and limitations of distinctive defect imaging techniques concerning specific defect types, sizes, and conditions. It was found that electron imaging can provide more abnormal detection capabilities while maintaining a higher measuring accuracy, against the conventional metallography in this case study, compared with NIR and CT imaging techniques.

36 MATERIALS SCIENCE↗

Male Runners With Lower Energy Availability Have Impaired Skeletal Integrity Compared to Nonathletes

Abstract Context Female athletes, particularly runners, with insufficient caloric intake for their energy expenditure [low energy availability (EA) or relative energy deficiency] are at risk for impaired skeletal integrity. Data are lacking in male runners. Objective To determine whether male runners at risk for energy deficit have impaired bone mineral density (BMD), microarchitecture, and estimated strength. Design Cross-sectional. Setting Clinical research center. Participants 39 men (20 runners, 19 controls), ages 16–30 years. Main Outcome Measures Areal BMD (dual-energy x-ray absorptiometry); tibia and radius volumetric BMD and microarchitecture (high-resolution peripheral quantitative computed tomography); failure load (microfinite element analysis); serum testosterone, estradiol, leptin; energy availability. Results Mean age (24.5 ± 3.8 y), lean mass, testosterone, and estradiol levels were similar; body mass index, percent fat mass, leptin, and lumbar spine BMD Z-score (−1.4 ± 0.8 vs −0.8 ± 0.8) lower (P < .05); and calcium intake and running mileage higher (P ≤ .01) in runners vs controls. Runners with EA <median had lower lumbar spine (−1.5 ± 0.7, P = .028), while runners with EA ≥median had higher hip (0.3 ± 0.7 vs −0.4 ± 0.5, P = .002), BMD Z-scores vs controls. After adjusting for calcium intake and running mileage, runners with EA <median had lower mean tibial total and trabecular volumetric BMD, trabecular bone volume fraction, cortical porosity, and apparent modulus vs controls (P < .05). Appendicular lean mass and serum estradiol (R ≥ 0.45, P ≤ .046), but not testosterone, were positively associated with tibial failure load among runners. Conclusions Despite weight-bearing activity, skeletal integrity is impaired in male runners with lower caloric intake relative to exercise energy expenditure, which may increase bone stress injury risk. Lower estradiol and lean mass are associated with lower tibial strength in runners.

Haines, Melanie S. (ORCID:0000000310024754)↗

Probing Fundamental Mechanisms of Plastic Deformation with High Energy X-rays (Final Progress Report)

Overall, substantial progress was made on developing BCDI techniques in the direction of imaging defects in multi-crystal samples. Section 2.1 describes a new method to reconstruct the 3D atomic displacement field within a grain from multiple coherently resolved diffraction peaks. The key development is the ability to recover a best fit to the grain shape at the same time as the internal displacement (strain) variation with no prior knowledge of the microstructure. This is complemented by the development of a method, Sec. 2.2, to separate out sets of Laue reflections that belong to a single grain (and thus be able to index its orientation) in the commonly encountered situation in which the beam illuminates several grains in a given location. This is essential for enabling collection of coherent diffraction data (at APS 34-ID-C) from neighboring grains. All experiments depend on the quality of samples used. Although good progress has been made with thin film samples, we are working with a broader range of geometries. A new sample design uses a high-Z metal (e.g., Pt) deposited in a sub-micron trench in a low-Z metal (e.g., Al) so that the grain size is prevented from exceeding the current limit for BCDI. We also report in section 3.1 on successfully applying NF-HEDM to a fine-grain Mg sample that would normally be considered out of scope for the method. This represents progress towards being able to map out polycrystalline samples in 3D before performing BCDI on individual grains. We further report in section 3.2 on preliminary NF-HEDM characterization of a sample of UO2 that has sub-micron grains; the data imply the capability of mapping fine-grain polycrystals at 1-ID-E, again for the purposes of BCDI in the bulk. Lastly, our plan is to load grains in polycrystalline samples by inducing thermal stress. We also report the experimental measurements of the Ti- 6Al-4V alloy obtained at the European Synchrotron Radiation Facility (ESRF), which had been indexed and mapped via HEDM at APS in section 9. As discussed below, however, technique development pre-occupied the team throughout the project which meant that we did not make any significant progress towards answering the original hypotheses as stated in the proposal. In summary, we assert that we have made good progress in methods and samples and future work taking advantage of this progress is likely to obtain and analyze BCDI data from multiple adjacent grains in 3D polycrystals. Obtaining such data depends on re-gaining access to the Advanced Photon Source, which is anticipated in late summer or the Fall. In all cases, work has involved close collaboration with faculty, staff, postdocs and students from Brigham Young University (BYU), the Los Alamos National Laboratory and APS beamlines 1-ID and 34-ID.

36 MATERIALS SCIENCE↗

Refined room-temperature equation of state of Bi up to 260 GPa

At room temperature, bismuth undergoes several structural transitions with increasing pressure before taking on a body-centered cubic (bcc) phase at approximately 8 GPa. The bcc structure is stable to the highest measured pressure and its simplicity, along with its high compressibility and atomic number, makes it an enticing choice as a pressure calibrant. Here, we present three data sets on the compression of bismuth in a diamond anvil cell in a neon pressure medium, up to a maximum pressure of about 260 GPa. The use of a soft pressure medium reduces deviatoric stress when compared to previous work. With an expanded pressure range, a higher point density, and a decreased uniaxial stress component, we are able to provide more reliable equation of state parameters. We also conduct density functional theory electronic-structure calculations that confirm that the bcc phase is energetically favored at high pressure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Examining polymer‐protein biophysical interactions with small‐angle x‐ray scattering and quartz crystal microbalance with dissipation

Abstract Polymer‐protein hybrids can be deployed to improve protein solubility and stability in denaturing environments. While previous work used robotics and active machine learning to inform new designs, further biophysical information is required to ascertain structure–function behavior. Here, we show the value of tandem small‐angle x‐ray scattering (SAXS) and quartz crystal microbalance with dissipation (QCMD) experiments to reveal detailed polymer‐protein interactions with horseradish peroxidase (HRP) as a test case. Of particular interest was the process of polymer‐protein complex formation under thermal stress whereby SAXS monitors formation in solution while QCMD follows these dynamics at an interface. The radius of gyration ( R g ) of the protein as measured by SAXS does not change significantly in the presence of polymer under denaturing conditions, but thickness and dissipation changes were observed in QCMD data. SAXS data with and without thermal stress were utilized to create bead models of the potential complexes and denatured enzyme, and each model fit provided insight into the degree of interactions. Additionally, QCMD data demonstrated that HRP deforms by spreading upon surface adsorption at low concentration as shown by longer adsorption times and smaller frequency shifts. In contrast, thermally stressed and highly inactive HRP had faster adsorption kinetics. The combination of SAXS and QCMD serves as a framework for biophysical characterization of interactions between proteins and polymers which could be useful in designing polymer‐protein hybrids.

60 APPLIED LIFE SCIENCES↗

Applied in-plane strain effects on the polarization response of ferroelectric hafnium zirconium oxide thin films

The influence of biaxial stress on the maximum and remanent polarizations of 10 nm thick hafnium zirconium oxide thin films in metal–ferroelectric–metal capacitor structures has been quantified. In the as-prepared state with a nominal biaxial tensile strain of 0.20% and no applied extrinsic stress, remanent and maximum polarizations of 7.6 and 13.1 μC/cm 2 , respectively, were measured using a 2 MV/cm applied electric field. Reducing the intrinsic strain by 0.111% through the application of a compressive uniaxial stress results in a decrease in the remanent and maximum polarizations to 6.8 and 12.2 μC/cm 2 , respectively. Here, the polarization dependence on strain is nearly linear between these values. The observed variation in polarization with strain is consistent with strain impacting ferroelastic switching whereby in-plane tension increases the fraction of the short polar axis orienting out-of-plane, hence increasing out-of-plane polarization. In contrast, reducing the in-plane strain through compression results in an increase in the fraction of the long non-polar axis orienting out-of-plane, thereby decreasing out-of-plane polarization.

36 MATERIALS SCIENCE↗

Strain-induced topological transitions in epitaxial films of cadmium arsenide

Strain in epitaxial thin films can have a profound influence on their electronic bands. Here, we investigate the influence of epitaxial strains on the electronic states of (001)-oriented cadmium arsenide (Cd 3 As 2 ) thin films, which are two-dimensional topological insulators. Cd 3 As 2 films were grown coherently on Al 1−x In x Sb buffer layers with varying degrees of lattice mismatch to Cd 3 As 2 , producing in-plane stresses that ranged from compressive to tensile. Using magneto-transport measurements of the Landau levels of the lowest subbands, we show that films under compression remain in the two-dimensional topological insulator state, while a sufficiently large tensile stress induces a transition to a topologically trivial phase. These results qualitatively agree with expectations from theoretical models for these films. At the topological transition, the gap avoids completely closing, and we discuss possible origins.

36 MATERIALS SCIENCE↗

Effect of thermal aging on microstructure and stress corrosion cracking behavior of Alloy 152 weldment

Nickel-based Alloy 690 and the associated weld Alloys 52 and 152 are typically used for nozzle penetrations in replacement heads for pressurized water reactor (PWR) vessels, because of their excellent overall resistance to general corrosion and environmental degradation, primarily stress corrosion cracking (SCC). However, many of the existing PWRs are expected to operate for 40-80 years. Likewise, water-cooled small modular reactors (SMRs) will use Ni-Cr alloys and are expected to receive initial operating licenses for 60 years. Hence, the thermal stability of Ni-Cr alloys is a potential concern for the long-term performance of both existing and advanced nuclear power plants, and possibly spent fuel storage containers. The objective of this research is to understand the microstructural changes occurring in high-Cr, Ni-based Alloy 152 weldments during long time exposure to the reactor operating temperatures, and the effect of these changes on the service performance. One area of particular concern is the potential for long range ordering (LRO), i.e. formation of the intermetallic Ni2Cr phase under prolonged exposure to reactor temperatures and/or irradiation, which can increase strength, decrease ductility, and cause dimensional changes or lead to in-service embrittlement of components made with these alloys. Hence, this research focused on the microstructural evolution and the SCC response of Alloy 152 under accelerated thermal aging. The materials studied involved three heats of Alloy 152 used to produce a dissimilar metal weld (DMW) joining an Alloy 690 plate to an Alloy 533 low alloy steel (LAS) plate, thermally aged at three different temperatures (370°C, 400°C and 450°C) for up to 75,000h (equivalent to 60 years of service). The microstructural characterization by means of synchrotron X-ray conducted in small, 0.2 mm - step line scans in the high-deformation regions of the weld root – covering areas spanning from the weld heat affected zone (HAZ) in Alloy 690 to the weld and weld butter on LAS - did not show evidence of LRO in any of the three Alloy 152 heats aged to an equivalent of 60 years of service. Testing in a primary water environment of two heats of Alloy 152 aged at 370°C to a 60-year service equivalent revealed a fatigue and corrosion fatigue crack growth responses similar to those measured on the un-aged alloys. However, the SCC CGR response of the aged samples appears to show a deterioration in performance, confirming our previous observation.

36 MATERIALS SCIENCE↗

Effect of Thermal Aging on Microstructure and Stress Corrosion Cracking Behavior of an Alloy 152 1st Layer Butter Weldment

Nickel-based Alloy 690 and the associated weld Alloys 52 and 152 are typically used for nozzle penetrations in replacement heads for pressurized water reactor (PWR) vessels, because of their excellent overall resistance to general corrosion and environmental degradation, primarily stress corrosion cracking (SCC). However, many of the existing PWRs are expected to operate for 40- 80 years. Likewise, water-cooled small modular reactors (SMRs) will use Ni-Cr alloys and are expected to receive initial operating licenses for 60 years. Hence, the thermal stability of Ni-Cr alloys is critical for the long-term performance of both existing and advanced nuclear power plants, and possibly spent fuel storage containers. The objective of this research is to understand the microstructural changes occurring in high-Cr, Ni-based Alloy 152 weldments during long time exposure to the reactor operating temperatures, and the effect of these changes on the service performance. One area of particular concern is the potential for long range ordering (LRO), i.e. formation of the intermetallic Ni2Cr phase under prolonged exposure to reactor temperatures and/or irradiation, which can increase strength, decrease ductility, and cause dimensional changes or lead to in-service embrittlement of components made with these alloys. Hence, this research focused on the microstructural evolution and the SCC response of Alloy 152 under accelerated thermal aging. The materials studied involved three heats of Alloy 152 used to produce a dissimilar metal weld (DMW) joining an Alloy 690 plate to an Alloy 533 low alloy steel (LAS) plate, thermally aged at three different temperatures (370°C, 400°C and 450°C) for different durations up to 75,000h (equivalent to 60 years of reactor service). The microstructural characterization by means of synchrotron X-ray conducted in small, 0.2 mm - step line scans in the high-deformation regions of the weld root – covering areas spanning from the weld heat affected zone (HAZ) in Alloy 690 to the weld and weld butter on LAS - did not show evidence of LRO in any of the three Alloy 152 heats aged at 370°C and 450°C to an equivalent of 60 years of service. However, the first weld butter layer has high levels of deformation and is highly susceptible to SCC even in its non-aged condition. Nanohardness testing confirmed the extreme hardening with aging (ΔHV ≅ 100) at two locations within this weldment. In absence of LRO, hardening is suspected to be due to thermally-induced Cr carbide precipitation and coarsening. Testing in a primary water environment of the 1st layer of Alloy 152 weld butter aged at 370°C to a 60-year service equivalent revealed a fatigue and corrosion fatigue crack growth responses similar to those measured on the un-aged alloys. Similarly, the SCC CGR response of the aged weld butter does not appear to show a deterioration in performance, however, the difficult-to-test weldment geometry may affect the test results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗