At least 109 records · Page 6

Stress relaxation of high strength A-286 bolts in simulated storage at room temperature

It was concluded that thermally activated relaxation of the type customarily encountered at high temperatures was not expected to occur at the low temperatures where long time NERVA storage conditions will prevail. Instances where relaxation occurred by a different mechanism at such moderate temperatures were also reported. Twelve simulated bolted flange test specimens were prepared. Parameters that were varied among the twelve specimens were the flange material, the bolt shank diameter, and the bolt loading in terms of percent of yield strength.

Sampson, R. C.↗

Light-induced stress relief to improve flaw tolerance in network polymers

We demonstrate the ability to use photoactivated stress relaxation to improve flaw tolerance in network polymers. Unlike most self-healing polymers, which effectively close flaws by locally introducing healing agents (such as uncured resins), here light is used to relax elevated stresses around a flaw before it reaches a critical state, which reduces the threat that the flaw poses to the structural integrity of the material. In this study, we fabricate specimens with well-defined flaws and uniaxially stretch them to failure. By irradiating the specimens with UV light (365 nm) before failure, the nominal strain at failure is increased by 70% and the corresponding nominal stress is increased by 30% compared with nonirradiated specimens. To better understand the phenomena that occur at the multiaxial stress state at the flaw, we model the photomechanics using a recently developed finite element approach that accurately describes the light propagation, photochemistry, radical-induced network evolution, and the mechanical behavior of the material. Model predictions agree well with the experimental results and elucidate the role that photoinduced stress relaxation has on improving flaw tolerance.

36 MATERIALS SCIENCE↗

Internal strain analysis of ceramics using scanning laser acoustic microscopy

Quantitative studies of material behavior characteristics are essential for predicting the functionality of a material under its operating conditions. A nonintrusive methodology for measuring the in situ strain of small dimeter (to 11 microns) ceramic fibers under uniaxial tensile loading and the local internal strains of ceramics and ceramic composites under flexural loading is introduced. The strain measurements and experimentally observed mechanical behavior are analyzed in terms of the microstructural development and fracture behavior of each test specimen evaluated. Measurement and analysis of Nicalon silicon carbide (SiC) fiber (15 microns diameter) indicate that the mean elastic modulus of the individual fiber is 185.3 GPa. Deviations observed in the experimentally determined elastic modulus values between specimens were attributed to microstructural variations which occur during processing. Corresponding variations in the fracture surface morphology were also observed. The observed local mechanical behavior of a lithium alumino-silicate (LAS) glass ceramic, a LAS/SiC monofilament composite, and a calcium alumino-silicate (CAS)/SiC fully reinforced composite exhibits nonlinearities and apparent hysteresis due to the subcritical mechanical loading. Local hysteresis in the LAS matrices coincided with the occurrence of multiple fracture initiation sites, localized microcracking, and secondary cracking. The observed microcracking phenomenon was attributed to stress relaxation of residual stresses developed during processing, and local interaction of the crack front with the microstructure. The relaxation strain and stress predicted on apparent mechanical hysteresis effects were defined and correlated with the magnitude of the measured fracture stress for each specimen studied. This quantitative correlation indicated a repeatable measure of the stress at which matrix microcracking occurred for stress relief of each material system. Stress relaxation occurred prior to the onset of steady state cracking conditions. The relaxation stress occurred at 18.5 percent of the fracture stress in LAS and 11.0 percent of the yield stress in CAS/SiC. The relaxation stress ratio was dependent upon the dominant fracture mode of the LAS/SiC specimens. Relaxation stress ratios greater than 0.30 were observed for specimens which fractured due to shear at the fiber matrix interface; specimens which fracture due to tensile cracking had relaxation stress ratios less than 0.30. The stress relaxation ratio appeared to be a specific characteristic of the glass ceramic material. The measured stress relaxation for LAS indicated a measure of the inherent residual stresses in the material due to processing and suggested localized toughening mechanisms for brittle material structures.

Kent, Renee M.↗

Lithium Deposition-Induced Fracture of Carbon Nanotubes and Its Implication to Solid-State Batteries

The increasing demand for safe and dense energy storage has shifted research focus from liquid electrolyte-based Li-ion batteries toward solid-state batteries (SSBs). However, the application of SSBs is impeded by uncontrollable Li dendrite growth and short circuiting, the mechanism of which remains elusive. Herein, we conceptualize a scheme to visualize Li deposition in the confined space inside carbon nanotubes (CNTs) to mimic Li deposition dynamics inside solid electrolyte (SE) cracks, where the high-strength CNT walls mimic the mechanically strong SEs. We observed that the deposited Li propagates as a creeping solid in the CNTs, presenting an effective pathway for stress relaxation. When the stress-relaxation pathway is blocked, the Li deposition-induced stress reaches the gigapascal level and causes CNT fracture. Mechanics analysis suggests that interfacial lithiophilicity critically governs Li deposition dynamics and stress relaxation. Furthermore, our study offers critical strategies for suppressing Li dendritic growth and constructing high-energy-density, electrochemically and mechanically robust SSBs.

25 ENERGY STORAGE↗

Improved Creep-­Fatigue Models on Advanced Materials for SFR Applications (Final Report)

This report provides an update on the materials performance criteria and methodology relevant to sodium-cooled fast reactors (SFRs). The report is the second deliverable (Level 2) in FY11 (M2A11AN040303) under the work package A-11AN040303 “Materials Performance Criteria and Methodology” as part of the Advanced Structural Materials Program for the Advanced Reactor Concepts. The overall objective of the Materials Performance Criteria and Methodology work project is to evaluate the key requirements for the ASME Code qualification and the Nuclear Regulatory Commission (NRC) approval of advanced structural materials in support of the design and performance of sodium-cooled fast reactors. Advanced materials are a critical element in the development of fast reactor technologies. Enhanced materials performance not only improves safety margins and provides design flexibility, but also is essential for the economics of future advanced fast reactors. Qualification and licensing of advanced materials are prominent needs for the development and implementation of advanced fast reactor technologies. Nuclear structural component designs in the U.S. comply with the ASME Boiler and Pressure Vessel (B&PV) Code Section III (Rules for Construction of Nuclear Facility Components), and the NRC grants licensing. As the SFRs will operate at higher temperatures than the current light water reactors (LWRs), the design of elevated-temperature components must comply with ASME Section III Subsection NH (Class 1 Components in Elevated Temperature Service). A number of technical issues relevant to materials performance criteria and high temperature design methodology in the SFR were identified and presented in earlier reports. A viable approach to resolve these issues and the R&D priority were also recommended. The development of mechanistically based creep-fatigue interaction models for life prediction and reliable data extrapolation was chosen to be the central focus in near-term efforts. Our current focus is on the creep-fatigue damage issue in high-strength ferritic/martensitic steels such as mod.9Cr-1Mo (G91) and NF616 (G92) steels. The current ASME creep-fatigue design rule puts severe limits of fatigue and creep loads for G91 steel, the lead structural material for fast reactors. High-strength ferritic/martensitic steels behave fundamentally differently from austenitic stainless steels, for which the current ASME creep-fatigue design rules were developed. The unique deformation and damage characteristics in G91 steel, e.g. cyclic softening, degradation of creep and rupture strength during cyclic service, demands a new creep-fatigue design procedure that explicitly accounts for the material’s unique creep-fatigue behavior. G92 steel, a variant of G91 steel, is the lead candidate in the Advanced Alloy Development program. There is currently no creep-fatigue design rule available for this advanced alloy. To support the predictive model development and resolve the over-conservative issue with the ASME design rule for G91 steel, we recovered stress relaxation data from thirteen creep-fatigue tests conducted in the late 1980s and early 1990s at Oak Ridge National Laboratory, and conducted extensive data analysis in FY10. Based on this database and available literature data, we have developed a Cyclic Softening Model and a Stress Relaxation Model specifically applied to G91 steel. The Cyclic Softening Model describes the cyclic stress variation as a function of cycle number during creep-fatigue loading, and well captures the cyclic softening effect in G91 steel. The Stress Relaxation Model predicts the stress relaxation curve during the hold time of cyclic loading, and its dependence on the cyclic softening effect of G91 steel. Two creep-fatigue test systems have been set up to conduct model-oriented creep-fatigue experiments. Results from three creep-fatigue experiments on Heat 30176 of G91 steel are presented in the report: (1) a test performed at 550°C with total strain amplitude of 0.25% and a hold time of 60 s applied at peak strains in both tension and compression, (2) a test performed at 400°C with total strain amplitude of 0.5% and a tension and compression hold time of 60 s, and (3) a test performed at 20°C with total strain amplitude of 0.5% and a tension and compression hold time of 60 s. Three different test temperatures were chosen for two primary reasons: to determine the transition temperature of creep-fatigue interaction from a plasticity-dominated process to a creep-dominated process; to develop unified creep-fatigue models applicable for a wide range of temperatures. With the detailed information obtained in the creep-fatigue experiments, we have further refined the Cyclic Softening Model and Stress Relaxation Model. The Cyclic Softening Model and Stress Relaxation Model were incorporated into the Bilinear Creep-Fatigue Damage Model, forming a powerful framework for the life prediction by an improved creep-fatigue evaluation methodology. The cyclic softening and consecutive stress relaxation responses in G91 steel can be considered for each cycle of the entire cyclic process in the model calculation. The creep-fatigue damage in G91 steel was evaluated using the improved Bilinear Creep-Fatigue Damage Model without any safety margins. It was found that due to the significant cyclic softening in G91 steel, the unit creep damage in each cycle decreased continuously with increasing number of cycles. This continuous change in creep damage with cycling has significant implication in the evaluation of the total creep-fatigue damage. The total creep damage can be one order of magnitude lower when the unit creep damage at half-life was used in the evaluation in comparison with the calculations using the unit creep damage at cycle 10. An important conclusion was that the accurate assessment of the creep-fatigue damage in G91 steel must consider the history of cycling. This analysis provides a more realistic assessment of creep-fatigue damage and identifies critical factors that must be considered in the development of future advanced models for high-strength ferritic/martensitic alloys. An accelerated creep-fatigue testing methodology is proposed for the design of model-oriented experiments to guide and validate model developments. Future work will focus on creep-fatigue experiments of both G91 and G92 steels, and development of creep-fatigue models applicable to advanced ferritic/martensitic alloys. The Cyclic Softening Model and Stress Relaxation Model will be improved by incorporating microstructural parameters of dislocation density, subgrain structure, and second-phase particles. Collaborative modeling of combined Cyclic Softening Model, Stress Relaxation Model, and Interactive Damage Rate Model will be pursued for life prediction under creep-fatigue loading with extended hold time. Accelerated, well-controlled creep-fatigue tests will be conducted to provide high-quality experimental data to refine key material parameters and validate models.

Li, Meimei↗