Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample Handling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Reconstruction of Intensity From Covered Samples

The safe handling of activated samples requires containment and covering the sample to eliminate any potential for contamination. Subsequent characterization of the surface with x-rays ideally necessitates a thin film. While many films appear visually transparent, they are not necessarily x-ray transparent. Each film material has a unique beam attenuation and sometimes have amorphous peaks that can superimpose with those of the sample. To reconstruct the intensity of the underlying activated sample, the x-ray attenuation and signal due to the film needs to be removed from that of the sample. This requires the calculation of unique deconvolution parameters for the film. The development of a reconstruction procedure for a contained/covered sample is described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nonparametric Multiparticle Set Methods for Interpreting Environmental Samples

Collection and analysis of environmental samples is commonly used by a range of stakeholders in nuclear safeguards and security contexts. While the ubiquity of samples and their transport in the environment allow regular collection, developing and demonstrating methods for analyzing these samples is difficult. In this work, an environmental sample consists of a set of one or more individual particles. Recent advances in reactor simulation have allowed us to generate data that are more representative of real-world environmental samples, enabling statistically defensible method development and testing. The most notable of these advances is a drastic increase in the number of material depletion regions, which allows our simulations to capture the variation in isotopic composition seen at length scales consistent with environmental samples. Traditional approaches for handling multiparticle samples treat each particle in the sample individually, estimating the quantity of interest (e.g., core-average burnup) resulting from measurement and analysis of signatures (e.g., nuclide assays) from each individual particle. Individual estimates are then averaged to generate a single estimate of the quantity of interest over the entire sample. In this presentation, we introduce two novel approaches for interpreting environmental samples that comprise of multiple particles: (1) the Quantile-Quantile Comparator, which uses a multivariate generalization of quantile-quantile plots for comparing unknown statistical distributions, and (2) the Set Transformer, an attention-based neural network module designed to model interactions among elements (particles) in the input set (sample). Statistically representative sampling cannot be guaranteed as samples are passively collected and are beholden to what particles are available in the environment. These new analysis methods for set-input problems are expected to be more robust than traditional approaches to issues of sampling bias where particles are not uniformly distributed throughout regions of interest, as well as generally outperform traditional approaches by jointly considering all elements in the set. We will present results comparing the performance of traditional single particle approaches and the novel Quantile-Quantile Comparator and Set Transformer for interpretation of simulated environmental samples.

Phathanapirom, Birdy↗

2012-13 Blue Room Low Enriched Uranium Sample Irradiation, Associated Gas Handling System, and Subsequent Separation Chemistry

An irradiation experiment was designed for the production of 100 mCi of medical isotope Mo-99 from a Low Enriched Uranium (LEU) solution. 300 mL of 150 gU/L LEU sulfate solution (pH1) was prepared and irradiated at the LANSCE Blue Room facility. The apparatus designed for the irradiation included a gas handling system, in which safe operation could be controlled by monitoring change in gas pressure. The gas handling system also contained a hydrogen oxygen recombiner, to recombine the gases generated through radiolysis of water, and an iodine trap, primarily for I-131. Pressure transients were observed during irradiation, which could be controlled by increasing the flow rate of the circulating pump. After irradiation the LEU solution was transferred to a hot cell facility for subsequent Mo-99 recovery using a titania column separation process, with samples also subsequently shipped to a radiochemical laboratory for further analysis. Gamma spectroscopy analysis revealed that ca. 70 mCi of Mo-99 was present at end of beam, in good agreement with the predicted value when actual beam history was included into the calculation. There was 80-85 % recovery of Mo-99 through a titania column separation, excluding losses through radioactive decay. The % Mo-99 recovery was lower than observed previously for the 1 mCi Mo-99 production (Target 4) experiments undertaken at LANL using the same separation apparatus, with on this occasion evidence of lower oxidation state molybdenum remaining irreversibly bound to the titania column. Subsequent postmortem analysis of the Blue room apparatus revealed that there had been no leaks in the gas handling system, the hydrogen and oxygen recombination appeared to work efficiently, and recovery of irradiated uranium trapped in the system allowed for >99% uranium mass balance.

07 ISOTOPE AND RADIATION SOURCES↗

Factors influencing moisture analysis in the 3013 destructive examination surveillance program

Thermogravimetric analysis of a solid sample with mass spectrometry (TGA-MS) of the evolved gas is used in the destructive examination (DE) portion of the Integrated Surveillance Program to quantify the moisture content of the material stored in a 3013 container. As with any measurement determined from a small sample, the collection, storage, transportation, and handling of the sample can affect its ability to represent the properties of the bulk material. During the course of the DE program, questions have periodically arisen concerning the ability of the moisture sample to reflect reliably the actual moisture content of the entire material stored in the 3013 container. Most concerns are related to the ability to collect a representative sample and to preserve the moisture content of the sample between collection and analysis. Recent delays in analysis caused by maintenance issues with the TGA-MS instrument presented a unique opportunity to document and quantify the effects various factors have on the TGA-MS moisture measurement. This report will use recent data to document the effects that current sample collection and handling practices have on the TGA-MS moisture measurement. Some suggestions will be made which could improve the current sample collection and handling practices for the TGA-MS moisture measurement so that the analytical results more accurately reflect the moisture content of the material stored in the 3013 container.

3013↗

Colling Wipe Samples for VX Analysis

This standard operating procedure (SOP) provides uniform procedures for the collection of wipe samples of VX residues from surfaces. Personnel may use this procedure to collect and handle wipe samples in the field. Various surfaces, including building materials (wood, metal, tile, vinyl, etc.) and equipment, may be sampled based on this procedure. The purpose of such sampling is to determine whether or not the relevant surfaces are contaminated, to determine the extent of their contamination, to evaluate the effectiveness of decontamination procedures, and to determine the amount of contaminant that might present as a contact hazard.

54 ENVIRONMENTAL SCIENCES↗

Examination of core samples from the Mount Elbert Gas Hydrate Stratigraphic Test Well, Alaska North Slope: Effects of retrieval and preservation

Collecting and preserving undamaged core samples containing gas hydrates from depth is difficult because of the pressure and temperature changes encountered upon retrieval. Hydrate-bearing core samples were collected at the BPXA-DOE-USGS Mount Elbert Gas Hydrate Stratigraphic Test Well in February 2007. Coring was performed while using a custom oil-based drilling mud, and the cores were retrieved by a wireline. The samples were characterized and subsampled at the surface under ambient winter arctic conditions. Samples thought to be hydrate bearing were preserved either by immersion in liquid nitrogen (LN), or by storage under methane pressure at ambient arctic conditions, and later depressurized and immersed in LN. Eleven core samples from hydrate-bearing zones were scanned using x-ray computed tomography to examine core structure and homogeneity. Features observed include radial fractures, spalling-type fractures, and reduced density near the periphery. These features were induced during sample collection, handling, and preservation. Isotopic analysis of the methane from hydrate in an initially LN-preserved core and a pressure-preserved core indicate that secondary hydrate formation occurred throughout the pressurized core, whereas none occurred in the LN-preserved core, however no hydrate was found near the periphery of the LN-preserved core. To replicate some aspects of the preservation methods, natural and laboratory-made saturated porous media samples were frozen in a variety of ways, with radial fractures observed in some LN-frozen sands, and needle-like ice crystals forming in slowly frozen clay-rich sediments. Suggestions for hydrate-bearing core preservation are presented.

54 ENVIRONMENTAL SCIENCES↗

BioSAXS Sample Changer: a robotic sample changer for rapid and reliable high-throughput X-ray solution scattering experiments

A robotic sample changer for solution X-ray scattering experiments optimized for speed and to use the minimum amount of material has been developed. This system is now in routine use at three high-brilliance European synchrotron sites, each capable of several hundred measurements per day. Small-angle X-ray scattering (SAXS) of macromolecules in solution is in increasing demand by an ever more diverse research community, both academic and industrial. To better serve user needs, and to allow automated and high-throughput operation, a sample changer (BioSAXS Sample Changer) that is able to perform unattended measurements of up to several hundred samples per day has been developed. The Sample Changer is able to handle and expose sample volumes of down to 5 µl with a measurement/cleaning cycle of under 1 min. The samples are stored in standard 96-well plates and the data are collected in a vacuum-mounted capillary with automated positioning of the solution in the X-ray beam. Fast and efficient capillary cleaning avoids cross-contamination and ensures reproducibility of the measurements. Independent temperature control for the well storage and for the measurement capillary allows the samples to be kept cool while still collecting data at physiological temperatures. The Sample Changer has been installed at three major third-generation synchrotrons: on the BM29 beamline at the European Synchrotron Radiation Facility (ESRF), the P12 beamline at the PETRA-III synchrotron (EMBL@PETRA-III) and the I22/B21 beamlines at Diamond Light Source, with the latter being the first commercial unit supplied by Bruker ASC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sampling and Analysis Plan for Investigation of Undeclared Nuclear Activities - 20104

The nuclear-centered energy policy in South Korea is moving towards a nuclear-free era. It also facilitates an action or progress on the denuclearization of the Korean peninsula. The Nuclear Safety and Security Commission (NSSC) launched a new R and D project which attempts to verify nuclear activities via analyzing environmental samples. Environmental samples possibly contain significant radiological information relevant to past undeclared activities. In order to precisely verify them, it is essential to provide 1) the concrete information of target facilities, 2) appropriate methodologies and procedures, and 3) well-suited instrumentation and equipment corresponding to sample signatures. It is also important to provide scientific reliability or validity in any process such as sample collection, handling, transportation and laboratory analysis. Therefore, the information of nuclear facilities (fuel fabrication plant, graphite moderated reactor, reprocessing plant) in North Korea are reviewed in order to determine parameters for appropriate sampling methods representing a facility's characteristics. Secondly, a sampling procedure for radioactive elements is being developed based on international and domestic standards such as ASTM (American Society for Testing and Materials), KS (Korean industrial Standards), and International Atomic Energy Agency (IAEA) manuals. The procedure contains some specific information including sampling process, sampling tools, amount of sample, sample identification, and other related information. Developing the qualified national guidelines is most important since sampling and analyzing results can be used as evidences of nuclear activities. The guideline developed through this work will clearly define various methodologies such as document verification, sampling procedures, collection methods, sample storage criteria, chain of custody, and transportation conditions. The final objective of this work is to establish the infrastructure and regulatory framework for assessment of nuclear activities, and provide a national guideline for sampling and analysis. This will bring confidence in the results and play a critical role in complete denuclearization progress in South Korea. (authors)

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Improving public communication through environmental data transparency at Los Alamos National Laboratory - 15306

The Los Alamos National Laboratory (LANL) environmental data span a wide range of media, including air, soil, sediment, water, foodstuff, and biota as well as over 1000 analytes and time periods extending over 4 decades, resulting in over 14 million records to manage and analyze. At a time of budget cuts and rapid social and technological change, the public, regulatory and compliance agencies, and stakeholders demand accelerated data delivery and efficiency, information sharing, and transparency in the dissemination and handling of samples collected in and around LANL. Meeting these requirements, while constraining the associated costs can be challenging; however, LANL has achieved this by adopting a cloud-based database called the Environmental Information Management (EIM) system and its public database counterpart, IntellusNM (Intellus) (www.intellusnm.com). To be consistent with federal initiatives to move government computing into cloud-based services, LANL chose to partner with an existing cloud-based vendor, Locus Technologies, to implement a software-as-a-service model. As an additional cost-saving measure, local regulatory and compliance agencies collaborated with LANL to incorporate their data into EIM and Intellus database. By adopting a single platform cloud-based solution to replace 12 different pre-existing environmental data systems, LANL has streamlined environmental data processes, resulting in over $15 million cost savings through 2015. EIM, LANL's internal cloud database, provides a cradle-to-grave process for data handling. EIM supports LANL's entire data process from detailed sample planning, mobile data collection using iOS mobile devices, to automated bottle labeling, generation of chain of custody, analytical lab electronic data deliverable upload, auto data validation, sample tracking, and custom regulatory and compliance reports. EIM has functionality to assess data in various ways such as the ability to design new formatted reports, a free-form structured query language tool of the entire database, exceedance reports, calculation engine, charting, trends, and statistics. EIM also has interactive geographic information system layers and analyte concentration color contour mapping capabilities. Additionally, and of greater importance to LANL, EIM supports the ability for third-party landowners to review data before release to the public, thus ensuring transparency and confidence in LANL's stewardship of human health and the environment. Intellus, the database counterpart of EIM, is the publicly available view of the entire LANL database and requires no data feeds or transformations. Intellus allows user-friendly access to LANL's environmental data as it is collected, providing the public, scientists, remediation teams, regulators, and stakeholders within hours of receipt. Full transparency in giving the public access to environmental data information provides LANL's overall solution to environmental data management for the public. By making the data easy to obtain, search, and query for interested stakeholders, the system enables confidence in LANL's stewardship of the environment. Working together identifies key topics of improvements, develop strategies and help support innovation and substantial advances within LANL's environmental data management system. (authors)

54 ENVIRONMENTAL SCIENCES↗

Solving Operational Challenges with INL's Integrated Waste Treatment Unit (IWTU) - 19003

In 2005, the THOR steam reforming fluidized-bed reactor technology was selected by the U.S. Department of Energy for treatment of sodium-bearing waste at the INL. The initial commissioning was typical, until June of 2012 when an over-pressurization event resulted in a significant release of solids. Recovery and subsequent testing systematically dealt with challenges associated with operation of three primary vessels: the denitration and mineralization reformer, the process gas filter, and the carbon reduction reformer. Additional challenges with the following ancillary systems surfaced during testing: the auger/grinder, sample system, and the approach to decontamination of the process vessels prior to outages. The major operational challenges covered fluidization issues, premature refractory failure, high-temperature gaseous filter element blinding, cementitious material formation in solids handling equipment, sampling reliability, and vessel decontamination. The purpose of this paper is to share the lessons learned during the extended commissioning of the Integrated Waste Treatment Unit. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design of a Biomass Scale Cubical Triaxial Tester

The bioenergy industry is dependent on predictable and reliable feedstock handling equipment. High profile failures in the industry demonstrate the need for better modeling tools for feedstock handling, specifically tools which can model the bulk flow of biomass feedstock materials in handling equipment such as hoppers or screw conveyors. Measurement of bulk material flow characteristics is a critical component to inform modeling tools. Following examples in the soils and pharmaceuticals industries, a Cubical Triaxial Tester (CTT) was selected as a critical component to study relationships between applied stress on a bulk sample and the resulting strain on the bulk material. In cooperation with The Pennsylvania State University, Forest Concepts designed a CTT specifically to measure bulk biomass flowability characteristics. Several mechanical design constraints were identified to ensure proper scaling and repeatability. Major design constraints included sample chamber size versus particle length, volumetric strain sensing accuracy, independent axial pressure control, and sample chamber handling. This report explains how major design constraints were determined.

09 BIOMASS FUELS↗

Small-Scale Testing of Plutonium(IV) Oxalate Precipitation and Calcination to Plutonium Oxide to Support the MOX Feed Mission

The H-Canyon facility will be used to dissolve Pu metal for subsequent purification and conversion to plutonium dioxide (PuO 2 ) using Phase II of HB-Line. To support the new mission, SRNL conducted a series of experiments to produce calcined plutonium (Pu) oxide and measure the physical properties and water adsorption of that material. This data will help define the process operating conditions and material handling steps for HB-Line. An anion exchange column experiment produced 1.4 L of a purified 52.6 g/L Pu solution. Over the next nine weeks, seven Pu(IV) oxalate precipitations were performed using the same stock Pu solution, with precipitator feed acidities ranging from 0.77 M to 3.0 M nitric acid and digestion times ranging from 5 to 30 minutes. Analysis of precipitator filtrate solutions showed Pu losses below 1% for all precipitations. The four larger precipitation batches matched the target oxalic acid addition time of 44 minutes within 4 minutes. The three smaller precipitation batches focused on evaluation of digestion time and the oxalic acid addition step ranged from 25-34 minutes because of pump limitations in the low flow range. Following the precipitations, 22 calcinations were performed in the range of 610 – 690 °C, with the largest number of samples calcined at either 650 or 635 °C. Characterization of the resulting PuO 2 batches showed specific surface areas in the range of 5-14 m 2 /g, with 16 of the 22 samples in the range of 5-10 m 2 /g. For samples analyzed with typical handling (exposed to ambient air for 15-45 minutes with relative humidities of 20-55%), the moisture content as measured by Mass Spectrometry ranged from 0.15 to 0.45 wt % and the total mass loss at 1000 °C, as measured by TGA, ranged from 0.21 to 0.58 wt %. For the samples calcined between 635 and 650 °C, the moisture content without extended exposure ranged from 0.20 to 0.38 wt %, and the TGA mass loss ranged from 0.26 to 0.46 wt %. Of these latter samples, the samples calcined at 650 °C generally had lower specific surface areas and lower moisture contents than the samples calcined at 635 °C, which matches expectations from the literature. Taken together, the TGA-MS results for samples handled at nominally 20-50% RH, without extended exposure, indicate that the Pu(IV) oxalate precipitation process followed by calcination at 635-650 °C appears capable of producing PuO 2 with moisture content < 0.5 wt % as required by the 3013 Standard. Exposures of PuO 2 samples to ambient air for 3 or more hours generally showed modest mass gains that were primarily gains in moisture content. These results point to the need for a better understanding of the moisture absorption of PuO 2 and serve as a warning that extended exposure times, particularly above the 50% RH level observed in this study will make the production of PuO 2 with less than 0.5 wt % moisture more challenging. Samples analyzed in this study generally contained approximately 2 monolayer equivalents of moisture. In this study, the bulk of the moisture released from samples below 300 °C, as did a significant portion of the CO 2 . Samples in this study consistently released a minor amount of NO in the 40-300 °C range, but no samples released CO or SO 2 . TGA-MS results also showed that MS moisture content accounted for 80±8% of the total mass loss at 1000 °C measured by the TGA. The PuO 2 samples produced had particles sizes that typically ranged from 0.2 – 88 μm, with the mean particle size ranging from 6.4 – 9.3 μm. The carbon content of ten different calcination batches ranged from 190-480 μg C/g Pu, with an average value of 290 μg C/g Pu.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of Fresh Nuclear Fuel using Time-Of-Flight Neutrons

Neutrons offer excellent characterization capabilities for nuclear fuels and can provide non-destructive insight on micro structure, chemistry and crystallographic phase. Measurements are possible at reactors or pulsed sources, but the inherent energy resolution implicit at pulsed sources offers unique opportunities. Recent advances in 2D neutron detection enabled new capabilities of material characterization using neutron imaging and tomography for nuclear materials. Moreover, time-of-flight (TOF) neutron measurements can enable isotope specific tomography by deriving isotope densities from transmission spectra exhibiting neutron resonances, which are recorded for each pixel. Tomographic algorithms allow 3D reconstructions of the spatial distribution of isotopes, density and features in typical fuel pellet samples. The ability to select radiographs for different energies allows characterizing samples which are opaque for thermal neutrons, such as enriched fuels or fuels containing plutonium, by selecting epi-thermal neutron energies and by knowledge of the total neutron cross sections of the constituents, isotopic enrichment levels can be determined. Nuclear cross sections are typically not calculated directly and databases such as the Evaluated Nuclear Data File (ENDF) database provide this information with cross sections determined by standardized experimental measurements, such as neutron transmission measurements for individual isotopes. Utilizing the information in the ENDF database, the 'inverse' problem can be solved by assuming cross section parameters to be known parameters and areal densities can be determined. This work presents recent advances at the Los Alamos Neutron Science Center (LANSCE) facility at Los Alamos National Laboratory (LANL), which provides the infrastructure to handle radioactive samples, in the development of fuel characterization with TOF neutrons. Examples include recent work on prototype accident tolerant nuclear fuels (ATF). The potential application of these techniques for nondestructive examination of irradiated fuel is under consideration. Non-destructive access to materials features for specimens embedded in containers, particularly for hazardous samples, such as a radioactive nuclear fuel, is indispensable to characterize and ultimately license new fuel forms. Energy-resolve neutron imaging is a new tool for this research field. The results reported here present a new imaging technique, setting a milestone in the capabilities of measuring non-destructively absolute quantities of physical properties. The enabling physics behind this new technique are nuclear resonances. We have demonstrated how absolute areal densities can be extracted from radiographs utilizing pulsed neutron sources. This technique provides information that is otherwise difficult and costly to obtain. In the case of nuclear fuels, the results from energy-dispersive neutron imaging may guide destructive examination of irradiated fuel. This summery does not describe recent analysis, which is ongoing. Particularly, the implementation of calibration standards has improved the determination of enrichment levels without additional calibration. The analysis of the samples was performed with full tomographic reconstructions for isotope specific data and presents a first approach in absolute isotope specific 3D reconstruction. This work was predominantly funded by and received substantial support from the Fuel Cycle R and D program at Los Alamos National Laboratory. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Intercomparison of the Radio-Chronometric Ages of Plutonium-Certified Reference Materials with Distinct Isotopic Compositions

In this article, an intercomparison of the radio-chronometric ages of four distinct plutonium-certified reference materials varying in chemical form, isotopic composition, and period of production are presented. The cross-comparison of the different 234 U/ 238 Pu, 235 U/ 239 Pu, 236 U/ 240 Pu, and 241 Am/ 241 Pu model purification ages obtained at four independent analytical facilities covering a range of laboratory environments from bulk sample processing to clean facilities dedicated to nuclear forensic investigation of environmental samples enables a true assessment of the state-of-practice in “age dating capabilities” for nuclear materials. The analytical techniques evaluated used modern mass spectrometer instrumentation including thermal ionization mass spectrometers and inductively coupled plasma mass spectrometers for isotopic abundance measurements. Both multicollector and single collector instruments were utilized to generate the data presented here. Consensus values established in this study make it possible to use these isotopic standards as quality control standards for radio-chronometry applications. Results highlight the need for plutonium isotopic standards that are certified for 234 U/ 238 Pu, 235 U/ 239 Pu, 236 U/ 240 Pu, and 241 Am/ 241 Pu model purification ages as well as other multigenerational radio-chronometers such as 237 Np/ 241 Pu. Due to the capabilities of modern analytical instrumentation, analytical laboratories that focus on trace level analyses can obtain model ages with marginally larger uncertainties than laboratories that handle bulk samples. Lastly, when isotope ratio measurement techniques like thermal ionization mass spectrometry and inductively coupled plasma mass spectrometry with comparable precision are utilized, model purification ages with similar uncertainties are obtained.

36 MATERIALS SCIENCE↗

System Integration for Remote Systems at DOE Hanford Nuclear Site - 18712

The deployment of remotely operated technology that functions in environments too hazardous for worker entry are often needed at the Hanford Site to perform functions like infrastructure inspection; decommissioning and decontamination; characterization; environmental sampling; and nuclear waste sampling, mobilization, and retrieval. The development and production of Hanford remote systems typically requires the integration of robotic components and sensor technologies that have been engineered or adapted to meet function and performance requirements. Pacific Northwest National Laboratory has led the engineering and integration of robotic and sensor/manipulator technology for several remote system deployments at Hanford and for national security sponsors. This paper describes the system integration process for ensuring that the mechanical, electrical, and software aspects of each component are successfully brought together to produce a remote system that meets function and performance requirements under extreme environments and limited-access operational demands. A brief summary of previous and current remote system projects is also provided. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advances in containment methods and plutonium recovery strategies that led to the structural characterization of plutonium(IV) tetrachloride tris-diphenylsulfoxide, PuCl 4 (OSPh 2 ) 3

In an attempt to further advance the understanding of plutonium coordination chemistry, we report a robust method for recycling and obtaining plutonium aqueous stock solutions that can be used as a convenient starting material in plutonium synthesis. This approach was used to prepare and characterize plutonium(IV) tetrachloride tris-diphenylsulfoxide, PuCl 4 (OSPh 2 ) 3 , by single crystal X-ray diffraction. The PuCl 4 (OSPh 2 ) 3 compound represents a rare example of a 7-coordinate plutonium(IV) complex. Structural characterization of PuCl 4 (OSPh 2 ) 3 by X-ray diffraction utilized a new containment method for radioactive crystals. The procedure makes use of epoxy, polyimide loops, and a polyester sheath to provide a robust method for safely containing and easily handling radioactive samples. Lastly, the described procedure is more user friendly than traditional containment methods that employ fragile quartz capillary tubes. Additionally, moving to polyester, instead of quartz, lowers the background scattering from the heavier silicon atoms.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Pushing the limits of high-resolution polymer microscopy using antioxidants

High-resolution transmission electron microscopy (HRTEM) has been transformative to the field of polymer science, enabling the direct imaging of molecular structures. Although some materials have remarkable stability under electron beams, most HRTEM studies are limited by the electron dose the sample can handle. Beam damage of conjugated polymers is not yet fully understood, but it has been suggested that the diffusion of secondary reacting species may play a role. As such, we examine the effect of the addition of antioxidants to a series of solution-processable conjugated polymers as an approach to mitigating beam damage. Characterizing the effects of beam damage by calculating critical dose D c values from the decay of electron diffraction peaks shows that beam damage of conjugated polymers in the TEM can be minimized by using antioxidants at room temperature, even if the antioxidant does not alter or incorporate into polymer crystals. As a consequence, the addition of antioxidants pushes the resolution limit of polymer microscopy, enabling imaging of a 3.6Å lattice spacing in poly[(5,6-difluoro-2,1,3-benzothiadiazol-4,7-diyl)-alt-(3,3"-di(2-octyldodecyl)-2,2';5',2";5",2"-quaterthiophene-5,5"-diyl)] (PffBT4T-2OD).

36 MATERIALS SCIENCE↗

Enclosed pillar arrays integrated on a fluidic platform for on-chip separations and analysis

Due to the difficulty of reliably producing sealed 3-D structures, few researchers have tackled the challenges of creating pillar beds suitable for miniaturized liquid phase separation systems. Herein, we describe an original processing sequence for the fabrication of enclosed pillar arrays integrated on a fluidic chip which, we believe, will further stimulate interest in this field. Our approach yields a mechanically robust enclosed pillar system that withstands mechanical impacts commonly incurred during processing, sealing and operation, resulting in a design particularly suitable for the research environment. A combination of a wafer-level fabrication sequence with chip-level elastomer bonding allows for chip reusability, an attractive and cost efficient advancement for research applications. The characteristic features in the implemented highly ordered pillar arrays are scalable to submicron dimensions. The proposed fluidic structures are suitable for handling picolitre sample volumes and offer prospects for substantial improvements in separation efficiency and permeability over traditional packed and monolithic columns. Our experimental observations indicate plate heights as low as 0.76 {mu}m for a 10 mm long pillar bed. Theoretical calculations confirm that ordered pillar arrays with submicron pore sizes combine superior analysis speed, picolitre sample volumes, high permeability and reasonably large plate numbers on a small footprint. In addition, we describe a fluidic interface that provides streamlined coupling of the fabricated structures with off-chip fluidic components.

36 MATERIALS SCIENCE↗