Electromagnetic and Hadron Calorimeters in the MIPP Experiment

The purpose of the MIPP experiment is to study the inclusive production of photons, pions, kaons, and nucleons in π, K, and p interactions on various targets using beams from the Main Injector at Fermilab. The function of the calorimeters is to measure the production of forward-going neutrons and photons. The electromagnetic calorimeter consists of 10 lead plates interspersed with proportional chambers. It was followed by the hadron calorimeter with 64 steel plates interspersed with scintillator. The data presented were collected with a variety of targets and beam momenta from 5 GeV/c to 120 GeV/c. The energy calibration of both calorimeters with electrons, pions, kaons, and protons is discussed. The resolution for electrons was found to be 0.27/sqrt(E), and for hadrons the resolution was 0.554/sqrt(E) with a constant term of 2.6%. The performance of the calorimeters was tested on a neutron sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic and hadron calorimeters in the MIPP experiment

The purpose of the MIPP experiment is to study the inclusive production of photons, pions, kaons, and nucleons in {pi}, K, and p interactions on various targets using beams from the Main Injector at Fermilab. The function of the calorimeters is to measure the production of forward-going neutrons and photons. The electromagnetic calorimeter consists of 10 lead plates interspersed with proportional chambers. It was followed by the hadron calorimeter with 64 steel plates interspersed with scintillator. The data presented were collected with a variety of targets and beam momenta from 5 to 120 GeV/c. The energy calibration of both calorimeters with electrons, pions, kaons, and protons is discussed. The resolution for electrons was found to be 0.27/{radical}E, and for hadrons the resolution was 0.554/{radical}E with a constant term of 2.6%. The performance of the calorimeters was tested on a neutron sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precipitation in a lead calcium tin anode

Samples from a hot rolled sheet of a tin and calcium bearing lead alloy were solution heat treated at 300 Degree-Sign C and cooled down to room temperature at different rates; these samples were left at room temperature to study natural precipitation of CaSn{sub 3} particles. The samples were aged for 45 days before analysing their microstructure, which was carried out in a scanning electron microscope using secondary and backscattered electron detectors. Selected X-ray spectra analyses were conducted to verify the nature of the precipitates. Images were taken at different magnifications in both modes of observation to locate the precipitates and record their position within the images and calculate the distance between them. Differential scanning calorimeter analyses were conducted on selected samples. It was found that the mechanical properties of the material correlate with the minimum average distance between precipitates, which is related to the average cooling rate from solution heat treatment. - Highlights: Black-Right-Pointing-Pointer The distance between precipitates in a lead alloy is recorded. Black-Right-Pointing-Pointer The relationship between the distance and the cooling rate is established. Black-Right-Pointing-Pointer It is found that the strengthening of the alloy depends on the distance between precipitates.

36 MATERIALS SCIENCE↗

X-ray transport and radiation response assessment (XTRRA) experiments at the National Ignition Facility

Our team has developed an experimental platform to evaluate the x-ray-generated stress and impulse in materials. Experimental activities include x-ray source development, design of the sample mounting hardware and sensors interfaced to the National Ignition Facility’s diagnostics insertion system, and system integration into the facility. This paper focuses on the X-ray Transport and Radiation Response Assessment (XTRRA) test cassettes built for these experiments. The test cassette is designed to position six samples at three predetermined distances from the source, each known to within ±1% accuracy. Built-in calorimeters give in situ measurements of the x-ray environment along the sample lines of sight. The measured accuracy of sample responses as well as planned modifications to the XTRRA cassette is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermodynamic analysis of binary Fe{sub 85}B{sub 15} to quinary Fe{sub 85}Si{sub 2}B{sub 8}P{sub 4}Cu{sub 1} alloys for primary crystallizations of α-Fe in nanocrystalline soft magnetic alloys

Fe-based Fe{sub 85}B{sub 15}, Fe{sub 84}B{sub 15}Cu{sub 1}, Fe{sub 82}Si{sub 2}B{sub 15}Cu{sub 1}, Fe{sub 85}Si{sub 2}B{sub 12}Cu{sub 1}, and Fe{sub 85}Si{sub 2}B{sub 8}P{sub 4}Cu{sub 1} (NANOMET{sup ®}) alloys were experimental and computational analyzed to clarify the features of NANOMET that exhibits high saturation magnetic flux density (B{sub s}) nearly 1.9 T and low core loss than conventional nanocrystalline soft magnetic alloys. The X-ray diffraction analysis for ribbon specimens produced experimentally by melt spinning from melts revealed that the samples were almost formed into an amorphous single phase. Then, the as-quenched samples were analyzed with differential scanning calorimeter (DSC) experimentally for exothermic enthalpies of the primary and secondary crystallizations (ΔH{sub x1} and ΔH{sub x2}) and their crystallization temperatures (T{sub x1} and T{sub x2}), respectively. The ratio ΔH{sub x1}/ΔH{sub x2} measured by DSC experimentally tended to be extremely high for the Fe{sub 85}Si{sub 2}B{sub 8}P{sub 4}Cu{sub 1} alloy, and this tendency was reproduced by the analysis with commercial software, Thermo-Calc, with database for Fe-based alloys, TCFE7 for Gibbs free energy (G) assessments. The calculations exhibit that a volume fraction (V{sub f}) of α-Fe tends to increase from 0.56 for the Fe{sub 85}B{sub 15} to 0.75 for the Fe{sub 85}Si{sub 2}B{sub 8}P{sub 4}Cu{sub 1} alloy. The computational analysis of the alloys for G of α-Fe and amorphous phases (G{sub α-Fe} and G{sub amor}) shows that a relationship G{sub α-Fe} ∼ G{sub amor} holds for the Fe{sub 85}Si{sub 2}B{sub 12}Cu{sub 1}, whereas G{sub α-Fe} < G{sub amor} for the Fe{sub 85}Si{sub 2}B{sub 8}P{sub 4}Cu{sub 1} alloy at T{sub x1} and that an extremely high V{sub f} = 0.75 was achieved for the Fe{sub 85}Si{sub 2}B{sub 8}P{sub 4}Cu{sub 1} alloy by including 2.8 at. % Si and 4.5 at. % P into α-Fe. These computational results indicate that the Fe{sub 85}Si{sub 2}B{sub 8}P{sub 4}Cu{sub 1} alloy barely forms amorphous phase, which, in turn, leads to high V{sub f} and resultant high B{sub s}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Summer Student Internship: Experimental and modeling experiences

My internship at the Los Alamos National Laboratory has been an information-filled summer. Loren Espada-Castillo brought me into her project and helped mentor and guide me through the summer. The project that I was brought into was the process of shooting materials with electrons. The electron beam we used conducts a series of shots in which electrons are generated and then fired towards a target, the sample holder. The sample holder holds either a single sample or three samples. The sample holder also consists of multiple calorimeters surrounding the sample/s. The goal is to shoot certain materials and then analyze how they react to the exposure of the electrons. We shot titanium, which was meant to serve as a containment vessel window.

36 MATERIALS SCIENCE↗

Progress and New Directions in Calorimetry: A 2014 Perspective

To assess progress in high‐temperature calorimetry over the past eighteen years, this feature article discusses both technical developments and new areas of application, with primary emphasis on high‐temperature oxide melt solution calorimetry. The Calvet calorimeter for such measurements is now commercially available, and an extensive table of enthalpies of drop solution (sample at room temperature dropped into molten oxide solvent in calorimeter and dissolved) is provided for the user community. New developments in methodology are described and applications to nanomaterials, to nitrides and other monoxide materials, and to lanthanides and actinides are given.

Navrotsky, Alexandra↗

Dual frequency comb spectroscopy of solid fuel pyrolysis and combustion: Quantifying the influence of moisture content in Douglas fir

As the fire research community develops multi-scale models to predict the spread of wildland fires, there is a need for well-controlled, small-scale experiments which provide benchmark data and fundamental understanding of the effects of key parameters on the combustion of wildland fuels. Here, we implement a unique suite of non-intrusive, quantitative diagnostics that simultaneously measure mass loss, surface temperature, in situ gas temperature and water vapor concentration, including the first implementation of dual frequency comb spectroscopy for the study of solid fuels. As a demonstration, we examine the effect of fuel moisture content on the burning of Douglas fir wood samples that are ignited under constant radiative heat flux from a cone calorimeter to provide benchmark data for multi-scale models. Peak flame temperatures 3 mm above the sample surface measured with the dual frequency comb laser spectrometer are in excess of 1200 K. The flame temperature decreases by over 150 K as fuel moisture content increases from 0.7% to 40%. This work demonstrates a platform for simultaneous, quantitative measurements of well-controlled small-scale experiments which provide benchmark data for the development of advanced modeling and simulations capable of capturing the complex physics present in wildland fire systems.

54 ENVIRONMENTAL SCIENCES↗

AC losses of Roebel and CORC ® cables at higher AC magnetic fields and ramp rates

We have measured ReBCO coated conductor-based conductor on round core (CORC ® ) and Roebel cables at 77 K in a spinning magnet calorimeter, which subjected the tapes in the samples to a radial magnetic field of 566 mT (peak) at frequencies up to 120 Hz (272 T s -1 , cyclic average) with an approximately sinusoidal waveform. The samples were oriented such that the field applied to the tapes within the cables was entirely radial, simplifying subsequent analysis. An expression for loss which included hysteretic, flux creep and eddy current losses was fit to both the CORC ® and the Roebel cables. This expression allowed easy comparison of the relative influence of eddy currents and flux creep (or power-law behavior) effects. The loss of both the CORC ® and Roebel cables measured here were seen to be essentially the sum of the hysteretic loss, flux creep effects, and the normal metal eddy current losses of the individual tapes. The losses of these cables were measured at high B × d B /d t with no coupling current loss observed under the present preparation conditions. The influence of flux creep effects on loss were not negligible. The losses of the CORC ® cable per meter of tape were seen to be reduced from the case of a flat tape because of the helical geometry of the tapes.

Physics↗

Forward hadron calorimeter for measurements of projectile spectators in heavy-ion experiment

The construction and performance of a modular hadron calorimeter for NA61 experiment at CERN are described. The calorimeter consists of individual lead/scintillator sandwich modules with the sampling satisfying the compensating condition. The light from the individual scintillator tiles is captured and transported with the WLS-fibers embedded in the scintillator grooves. The light readout is done by avalanche micro-pixel photodiodes. The construction ensures a fine transverse granulation of the calorimeter and a longitudinal segmentation of each module in 10 independent sections. The results of beam tests of the calorimeter prototype are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A High-Throughput MEMS-Based Differential Scanning Calorimeter for Direct Thermal Characterization of Antibodies

Calorimeters, which can be used for rapid thermal characterization of biomolecules, are getting intense attention in drug development. This paper presents a novel MEMS-based differential scanning calorimeter (DSC) for direct thermal characterization of protein samples. The DSC consisted of a pair of temperature sensors made by vanadium oxide (VOx) film with a temperature coefficient of resistivity of –0.025/K at 300 K, a microfluidic device with high thermal insulation (2.8 K/mW), and a Peltier heater for linear temperature scanning. The DSC exhibited high sensitivity (6.1 µV/µW), low noise (0.4 µW), high scanning rate (45 K/min), and low sample consumption volume (0.63 µL). The MEMS DSC was verified by measuring the temperature-induced denaturation of lysozyme at different pH, and then used to study the thermal stability of a monoclonal antibody (mAb), an antigen-binding fragment (Fab), and a dual variable domain immunoglobulin (DVD-Ig) at pH = 6. The results showed that lysozyme is a stable protein in the pH range of 4.0–8.0. The protein stability study revealed that the transition temperatures of the intact Fab fragment, mAb, and DVD proteins were comparable with conformational stability results obtained using conventional commercial DSC. These studies demonstrated that the MEMS DSC is an effective tool for directly understanding the thermal stability of antibodies in a high-throughput and low-cost manner compared to conventional calorimeters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of MERCI decay heat measurement for PWR UO{sub 2} fuel rod

Decay heat measurements, called the MERCI experiment, were conducted at Commissariat a l'Energie Atomique (CEA)/Saclay to characterize accurately residual power at short cooling time and verify its prediction by decay code and nuclear data. The MOSAIC calorimeter, developed and patented by CEA/Grenoble (DTN/SE2T), enables measurement of the decay heat released by a pressurized water reactor (PWR) fuel rod sample between 200 and 4 W within a precision of 1%. The MERCI experiment included three phases. At first, a UO{sub 2} fuel rod sample was irradiated in the CEA/Saclay experimental reactor OSIRIS. The burnup achieved at the end of irradiation was similar to 3.5 GWd/tonne. The second phase was the transfer of the fuel rod sample from its irradiation location to a hot cell, to be inserted inside the MOSAIC calorimeter. It took 26 min to carry out the transfer. Finally, decay heat released by the PWR sample was measured from 27 min to 42 days after shutdown. Post irradiation examinations were performed to measure concentrations of some heavy nuclei (U, Pu) and fission products (Cs, Nd). The decay heat was predicted using a calculation scheme based on the PEPIN2 depletion code, the TRIPOLI-4 Monte Carlo code, and the JEFF3.1.1 nuclear data file. The MERCI experiment analysis shows that the discrepancy between the calculated and the experimental decay heat values is included between -10% at 27 min and +6% at 12 h, 30 min otter shutdown. From 4 up to 42 days of cooling time, the difference between calculation and measurement is about ± 1%, i.e., experimental uncertainty. The MERCI experiment represents a significant contribution for code validation; the time range above 10{sup 5} s has not been validated previously. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Measurements of forward jet production in polarized pp collisions at √s = 500 GeV

The A{sub N }DY project at RHIC was proposed to measure the analyzing power for Drell-Yan production. Test runs took place during polarized proton operations of RHIC in 2011 and 2012 with a model of the A {sub N }DY apparatus in place. In total, an integrated luminosity of 9 pb{sup −1} with beam polarization of 50% was sampled. The primary detector components were a hadron calorimeter (HCal) that spanned the pseudorapidity interval 2.4 < η < 4.0 and a small electromagnetic calorimeter (ECal). Basic goals for A {sub N }DY test running were to establish the impact of a third interaction region on RHIC performance and to demonstrate HCal calibration. Energy scale of HCal was established using neutral pion reconstruction and checked with hadronic response. In addition, data with a trigger based on HCal energy sum were taken to study jet events. First measurements of analyzing power in the forward jet production are reported.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the inclusive isolated prompt photon cross section in pp collisions at √s=7 TeV with the ATLAS detector

A measurement of the cross section for the inclusive production of isolated prompt photons in pp collisions at a center-of-mass energy √s=7 TeV is presented. The measurement covers the pseudorapidity ranges |η γ |<1.37 and 1.52≤|η γ |<1.81 in the transverse energy range 15≤E γ T <100 GeV. The results are based on an integrated luminosity of 880 nb -1 , collected with the ATLAS detector at the Large Hadron Collider. Photon candidates are identified by combining information from the calorimeters and from the inner tracker. Residual background in the selected sample is estimated from data based on the observed distribution of the transverse isolation energy in a narrow cone around the photon candidate. The results are compared to predictions from next-to-leading-order perturbative QCD calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accelerating accurate simulations of calorimeter showers with normalizing flows and probability density distillation

Recently, we introduced caloflow, a high-fidelity generative model for GEANT4 calorimeter shower emulation based on normalizing flows. Here, we present caloflow v2, an improvement on our original framework that speeds up shower generation by a further factor of 500 relative to the original. The improvement is based on a technique called probability density distillation, originally developed for speech synthesis in the machine learning literature, and which we develop further by introducing a set of powerful new loss terms. We demonstrate that caloflow v2 preserves the same high fidelity as the original using qualitative (average images, histograms of high-level features) and quantitative (classifier metric between geant4 and generated samples) measures. The result is a generative model for calorimeter showers that matches the state of the art in speed (a factor of 10 4 faster than GEANT4) and greatly surpasses the previous state of the art in fidelity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spontaneous combustion prediction of coal by C80 and ARC techniques

Many coal fires were caused by spontaneous combustion in coal mines or coal storehouses, which resulted in a great loss and energy wastage. To identify and evaluate the hazardous degree of coal stockpile, a C80 microcalorimeter and accelerating rate calorimeter (ARC) were employed in this work. The coal samples undergo an exothermal process start at 80 {sup o}C with heat generation of -75.1 J g{sup -1} (mean value) detected by C80 experiment. The activation energies of the first exothermal process were calculated for the three experiments, and the mean value is 80.76 kJ mol{sup -1}, which is lower than that of obtained from the ARC result, 127.0 kJ mol{sup -1}. For a 300 tons coal stockpile, the self-heating oxidation temperatures (SHOT) were calculated as 164, 60, 90, and 68{sup o}C based on the ARC experiment and three C80 experiments, respectively. Further research on the mass effect on SHOT shows that if the coal mass is less than 12 tons, the danger of thermal spontaneous combustion is less. However, if the mass amount is more than 12000 tons, the danger of thermal spontaneous combustion is difficult to avoid even at ambient temperature if no special measures are taken. 38 refs., 9 figs.

01 COAL, LIGNITE, AND PEAT↗

Calibration of the BaBar CsI(Tl) Calorimeter

After nine years of operation, the BABAR experiment at the e{sup +}e{sup -} B factory PEP-II (Standford Linear Accelerator Center) stopped data taking in April 2008. An important part of the experiment is the electromagnetic calorimeter which consists of 6580 CsI crystals doped with thallium and read out by Si-PIN photodiodes. The light yield of the CsI crystals is changing in time due to radiation exposure. In addition to the changing light yield, passive material in front of and between the crystals as well as signal thresholds during the reconstruction influence the reconstructed energies. This requires a time-dependent calibration of the calorimeter. The calibration issues are reviewed and the calibration results obtained from various data samples are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical and experimental calibration of calorimetric sample cell dedicated to nuclear heating measurements

Online nuclear measurements inside experimental channels of MTRs are needed for experimental works (to design set-ups) and for numerical works (input data) in order to better understanding complex phenomena occurring during the accelerated ageing of materials and the irradiation of nuclear fuel. In this paper we focus only on one kind of measurements: nuclear heating performed by means of a radiometric calorimeter. The aims of numerical and experimental works are firstly to optimize the sensor response for new energy deposit ranges and then to miniaturize this sensor for JHR irradiation conditions A first calorimeter, developed previously by the CEA, is studied. It corresponds to a graphite differential calorimeter divided into two twin cells (a reference cell, and a sample one). It is used with a non adiabatic mode or heat flow mode. Experimental calibration of the sample cell is presented. In that case, energy deposit is simulated by Joule effect and the sample cell is inserted into a bath at a regulated temperature and controlled flow. The response of the sensor is shown versus electrical power imposed for two flow regimes (intensive or moderated forced convection). These experimental results are compared to numerical works and improvements are discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗