Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

The study of frequency-scan photothermal reflectance technique for thermal diffusivity measurement

A frequency scan photothermal reflectance technique to measure thermal diffusivity of bulk samples is studied in this manuscript. Similar to general photothermal reflectance methods, an intensity-modulated heating laser and a constant intensity probe laser are used to determine the surface temperature response under sinusoidal heating. The approach involves fixing the distance between the heating and probe laser spots, recording the phase lag of reflected probe laser intensity with respect to the heating laser frequency modulation, and extracting thermal diffusivity using the phase lag – (frequency) 1/2 relation. The experimental validation is performed on three samples (SiO 2 , CaF 2 and Ge), which have a wide range of thermal diffusivities. The measured thermal diffusivity values agree closely with literature values. Lastly, compared to the commonly used spatial scan method, the experimental setup and operation of the frequency scan method are simplified, and the uncertainty level is equal to or smaller than that of the spatial scan method.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Unusual flat and extended morphology of intercalated Cu under MoS 2

We report a general method was developed to intercalate metals under layered materials through a controlled density of sputtered defects. The method has already been applied to study a range of metals intercalated under graphite, and different types of morphologies were realized. In the current work, we extend the method to the study of intercalation under MoS 2 , noting that work on this system is rather limited. We use Cu as the prototype metal for comparison with Cu intercalation under graphite. Although the growth conditions needed for intercalation under graphite and MoS 2 are similar, the type of intercalated phases is very different. Each Cu island that nucleates on top of MoS 2 during Cu deposition provides material that is transferred below MoS 2 through sputtered defects under the island base; this transfer results in a uniform intercalated Cu “carpet” morphology that extends over the mesoscale. On the contrary, Cu intercalation under graphite results in well separated, compact islands formed by monomer detachment from small Cu islands on top and transfer below through defects far from the islands. The structural techniques (scanning electron microscopy and atomic force microscopy) and spectroscopic techniques (x-ray photoelectron spectroscopy and energy-dispersive spectroscopy) are used for the characterization of the intercalated Cu layer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Friction estimation technique for Galileo scan platform control

A friction estimation technique has been developed for the scan platform control of the Galileo spacecraft. The purpose of the estimation is to reduce the impact of friction in the scan platform actuator on the pointing performance of the scan platform so that tight pointing requirements can be met. The estimator operates by comparing the actual behavior of the platform with the expected behavior and attributing the difference to the presence of friction. The estimator is coupled with a proportional-integral-derivative controller to generate a control torque for the scan platform actuator. Since the algorithm will be implemented on an onboard digital computer, a stability analysis of the estimator-controller in discrete time is presented. The performance of the design is demonstrated by a sample slew test case.

Chodas, J. L.↗

Virtual Ultrasound Guidance for Inexperienced Operators

Medical ultrasound or echocardiographic studies are highly operator-dependent and generally require lengthy training and internship to perfect. To obtain quality echocardiographic images in remote environments, such as on-orbit, remote guidance of studies has been employed. This technique involves minimal training for the user, coupled with remote guidance from an expert. When real-time communication or expert guidance is not available, a more autonomous system of guiding an inexperienced operator through an ultrasound study is needed. One example would be missions beyond low Earth orbit in which the time delay inherent with communication will make remote guidance impractical. The Virtual Ultrasound Guidance system is a combination of hardware and software. The hardware portion includes, but is not limited to, video glasses that allow hands-free, full-screen viewing. The glasses also allow the operator a substantial field of view below the glasses to view and operate the ultrasound system. The software is a comprehensive video program designed to guide an inexperienced operator through a detailed ultrasound or echocardiographic study without extensive training or guidance from the ground. The program contains a detailed description using video and audio to demonstrate equipment controls, ergonomics of scanning, study protocol, and scanning guidance, including recovery from sub-optimal images. The components used in the initial validation of the system include an Apple iPod Classic third-generation as the video source, and Myvue video glasses. Initially, the program prompts the operator to power-up the ultrasound and position the patient. The operator would put on the video glasses and attach them to the video source. After turning on both devices and the ultrasound system, the audio-video guidance would then instruct on patient positioning and scanning techniques. A detailed scanning protocol follows with descriptions and reference video of each view along with advice on technique. The program also instructs the operator regarding the types of images to store and how to overcome pitfalls in scanning. Images can be forwarded to the ground or other site when convenient. Following study completion, the video glasses, video source, and ultrasound system are powered down and stored. Virtually any equipment that can play back video can be used to play back the program. This includes a DVD player, personal computer, and some MP3 players.

Caine, Timothy↗

Study of nonlinear optical properties of TiO{sub 2} – polystyrene nanocomposite films

We consider an ex-situ prepared TiO{sub 2} − polystyrene (TiO{sub 2} − PS) nanocomposite, with different concentration of TiO{sub 2} nanoparticles (NPs), deposited by the spin-coating method on quartz substrates. Nonlinear optical properties of the TiO{sub 2} − PS nanocomposite films are studied using the Z-scan technique. Structural properties of the films are investigated using scanning electron microscopy (SEM) and X-ray diffraction (XRD) measurements. The optical band gap energy of the TiO{sub 2} − PS films are determined from the optical absorption spectra. The relation between the optical nonlinearities and the bandgap energy, as a microscopic electronic property of the semiconductor nanocomposite, is established. It is shown that an increase in the content of TiO{sub 2} NPs in the nanocomposite films results in bandgap narrowing and concomitant enhancement of optical nonlinearities. It is proposed that bandgap narrowing and enhancement of optical nonlinearities can be ascribed to the introduction of mid-gap states as a result of the formation of surface defects in TiO{sub 2} NPs. The results of this work indicate that incorporation of TiO{sub 2} NPs in the PS polymeric matrix can be a new way for bandgap narrowing of TiO{sub 2} NPs toward the visible light region, which is of great interest for their application in this part of the spectrum. Furthermore, enhancement of the optical nonlinearities of the spin-coated TiO{sub 2} − PS films by increasing the TiO{sub 2} NP content can open up new avenues for their use as nonlinear optical films in photonics applications. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spaceborne laser radar.

Development of laser systems to acquire and track targets in applications such as the rendezvous and docking of two spacecraft. A scan technique is described whereby a narrow laser beam is simultaneously scanned with an equally narrow receiver field-of-view without the aid of mechanical gimbals. Equations are developed in order to examine the maximum acquisition and tracking rates, and the maximum target range for a scanning laser radar system. A recently built prototype of a small, lightweight, low-power-consuming scanning laser radar is described.

Flom, T.↗

Local Guided Wavefield Analysis for Characterization of Delaminations in Composites

Delaminations in composite laminates resulting from impact events may be accompanied by minimal indication of damage at the surface. As such, inspection techniques are required to ensure defects are within allowable limits. Conventional ultrasonic scanning techniques have been shown to effectively characterize the size and depth of delaminations but require physical contact with the structure. Alternatively, a noncontact scanning laser vibrometer may be used to measure guided wave propagation in the laminate structure. A local Fourier domain analysis method is presented for processing guided wavefield data to estimate spatially-dependent wavenumber values, which can be used to determine delamination depth. The technique is applied to simulated wavefields and results are analyzed to determine limitations of the technique with regards to determining defect size and depth. Finally, experimental wavefield data obtained in quasi-isotropic carbon fiber reinforced polymer (CFRP) laminates with impact damage is analyzed and wavenumber is measured to an accuracy of 8.5% in the region of shallow delaminations. Keywords: Ultrasonic wavefield imaging, Windowed Fourier transforms, Guided waves, Structural health monitoring, Nondestructive evaluation

Rogge, Matthew D.↗

Synthesis, growth, structure, mechanical and optical properties of a new semi-organic 2-methyl imidazolium dihydrogen phosphate single crystal

Highlights: • 2MIDP crystals were grown by slow evaporation solution growth technique. • Single crystal XRD revealed self-assembled supramolecular framework. • Z scan technique is employed for third order nonlinear optical susceptibility. • Structure-property correlation is established. - Abstract: A new semi-organic compound, 2-methyl imidazolium dihydrogen phosphate (2MIDP), was prepared and good quality single crystals of 2MIDP were grown by slow evaporation solution growth technique. Crystal structure elucidated using Single crystal XRD showed that 2MIDP crystallizes in monoclinic system with P2{sub 1}/c space group. FT-IR, UV-Vis-NIR, Fluorescence and FT-NMR spectra confirm the molecular structure of 2MIDP. The UV-Vis-NIR spectra established the suitability of the compound for NLO applications. TG-DSC showed that 2MIDP is thermally stable up to 200 °C. Mechanical characteristics like hardness number (H{sub v}), stiffness constant (C{sub 11}), yield strength (σ{sub v}), fracture toughness (K{sub c}) and brittleness index (B{sub i}) were assessed using Vicker’s microhardness tester. Third order nonlinear optical properties determined from Z-scan measurement using femto and picosecond lasers showed two photon reverse saturable absorption. The enhancement of nonlinear optical properties in femto second laser, revealed the suitability of 2MIDP for optical limiting applications.

36 MATERIALS SCIENCE↗

Investigation of optical limiting properties of Aluminium nanoparticles prepared by pulsed laser ablation in different carrier media

In this communication, we carried out the systematic investigation of nonlinear absorption and scattering properties of Aluminium nanoparticles (Al NPs) in various polar and non-polar solvents. Al NPs were synthesized with pulsed Nd:YAG laser operated at 1064 nm by ablating Al target in polar and non-polar liquid environment like chloroform, chlorobenzene, toluene, benzene, and carbon tetrachloride. Synthesized Al NPs colloids of various solvents differ in appearance and UV-Vis extinction spectra exhibit absorption in the UV region. The characterization of Al NPs performed by Transmission electron microscopy (TEM) studies reveal that NPs are made up of a well crystallized Al inner part (bright zone) embedded with an amorphous metal Al shell (dark region). Growth, aggregation, and precipitation mechanisms which influence the optical properties and stability of NPs are found to be related to the dipole moment of the surrounding liquid environment. The nonlinear absorption and scattering studies are performed by open aperture Z-scan technique with 532 nm under nanosecond pulse excitation. The Z-scan measurements are fitted theoretically to estimate both two-photon absorption (TPA) and nonlinear scattering (NLS) coefficients. In polar solvents like chlorobenzene, chloroform synthesized Al NPs exhibited higher TPA, NLS coefficient values, and lower optical limiting threshold values in comparison with partially polar solvent like toluene and non-polar solvents like benzene and carbontetrachloride. These results indicate the potential use of Al NPs as a versatile optical limiting material.

36 MATERIALS SCIENCE↗

Ultrasonic imaging of materials under unconventional circumstances

This paper reflects the contents of the plenary talk given by Nico Felicien Declercq. “Ultrasonic Imaging of materials” covers a wide technological area with main purpose to look at and to peek inside materials. In an ideal world one would manage to examine materials like a clairvoyant. Fortunately this is impossible hence nature has offered sufficient challenges to mankind to provoke curiosity and to develop science and technology. Here we focus on the appearance of certain undesired physical effects that prohibit direct imaging of materials in ultrasonic C-scans. Furthermore we try to make use of these effects to obtain indirect images of materials and therefore make a virtue of necessity. First we return to one of the oldest quests in the progress of mankind: how thick is ice? Our ancestors must have faced this question early on during migration to Northern Europe and to the America’s and Asia. If a physicist or engineer is not provided with helpful tools such as a drill or a device based on ultrasound, it is difficult to determine the ice thickness. Guided waves, similar to those used for nondestructive testing of thin plates in structural health monitoring can be used in combination with the human ear to determine the thickness of ice. To continue with plates, if an image of its interior is desired high frequency ultrasonic pulses can be applied. It is known by the physicist that the resolution depends on the wavelength and that high frequencies usually result in undesirably high damping effects inhibiting deep penetration into the material. To the more practical oriented engineer it is known that it is advantageous to polish surfaces before examination because scattering and diffraction of sound lowers the image resolution. Random scatterers cause some blurriness but cooperating scatters, causing coherent diffraction effects similar to the effects that cause DVD’s to show rainbow patterns under sunlight, can cause spooky images and erroneous measurements of material properties. However when properly understood, diffraction effects, for instance if one has no other options but to work with frequencies that are fortuitously very effectively diffracted by the surface structure of a material under investigation, can be used to obtain high contract images or to obtain information that would normally be hidden from standard C-scan techniques. Similar contrast enhancement is also obtained for oblique C-scans of composites.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Intensity-Modulated Proton Therapy Versus Helical Tomotherapy in Nasopharynx Cancer: Planning Comparison and NTCP Evaluation

Purpose: To compare intensity-modulated proton therapy (IMPT) and helical tomotherapy (HT) treatment plans for nasopharynx cancer using a simultaneous integrated boost approach. Methods and Materials: The data from 6 patients who had previously been treated with HT were used. A three-beam IMPT technique was optimized in the Hyperion treatment planning system, simulating a 'beam scanning' technique. HT was planned using the tomotherapy treatment planning system. Both techniques were optimized to simultaneously deliver 66 Gy in 30 fractions to planning target volume (PTV1; GTV and enlarged nodes) and 54 Gy to PTV2 subclinical, electively treated nodes. Normal tissue complication probability calculation was performed for the parotids and larynx. Results: Very similar PTVs coverage and homogeneity of the target dose distribution for IMPT and HT were found. The conformity index was significantly lower for protons than for photons (1.19 vs. 1.42, respectively). The mean dose to the ipsilateral and contralateral parotid glands decreased by 6.4 Gy and 5.6 Gy, respectively, with IMPT. The volume of mucosa and esophagus receiving {>=}20 Gy and {>=}30 Gy with IMPT was significantly lower than with HT. The average volume of larynx receiving {>=}50 Gy was significantly lower with HT, while for thyroid, it was comparable. The volume receiving {>=}30, {>=}20, and {>=}10 Gy in total body volume decreased with IMPT by 14.5%, 19.4%, and 23.1%, respectively. The normal tissue complication probability for the parotid glands was significantly lower with IMPT for all sets of parameters; however, we also estimated an almost full recovery of the contralateral parotid with HT. The normal tissue complication probability for the larynx was not significantly different between the two irradiation techniques. Conclusion: Excellent target coverage, homogeneity within the PTVs, and sparing of the organs at risk were reached with both modalities. IMPT allows for better sparing of most organs at risk at medium-to-low doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temperature dependence of resistivity of carbon micro/nanostructures: Microscale spatial distribution with mixed metallic and semiconductive behaviors

The temperature coefficient of resistivity (θ T ) of carbon-based materials is a critical property that directly determines their electrical response upon thermal impulses. It could have metal- (positive) or semiconductor-like (negative) behavior, depending on the combined temperature dependence of electron density and electron scattering. Its distribution in space is very difficult to measure and is rarely studied. Here, for the first time, we report that carbon-based micro/nanoscale structures have a strong non-uniform spatial distribution of θ T . This distribution is probed by measuring the transient electro-thermal response of the material under extremely localized step laser heating and scanning, which magnifies the local θ T effect in the measured transient voltage evolution. For carbon microfibers (CMFs), after electrical current annealing, θ T varies from negative to positive from the sample end to the center with a magnitude change of >130% over <1 mm. This θ T sign change is confirmed by directly testing smaller segments from different regions of an annealed CMF. For micro-thick carbon nanotube bundles, θ T is found to have a relative change of >125% within a length of ~2 mm, uncovering strong metallic to semiconductive behavior change in space. In conclusion, our θ T scanning technique can be readily extended to nm-thick samples with μm scanning resolution to explore the distribution of θ T and provide a deep insight into the local electron conduction.

36 MATERIALS SCIENCE↗

Some failure modes and analysis techniques for terrestrial solar cell modules

Analysis data are presented on failed/defective silicon solar cell modules of various types and produced by different manufacturers. The failure mode (e.g., internal short and open circuits, output power degradation, isolation resistance degradation, etc.) are discussed in detail and in many cases related to the type of technology used in the manufacture of the modules; wherever applicable, appropriate corrective actions are recommended. Consideration is also given to some failure analysis techniques that are applicable to such modules, including X-ray radiography, capacitance measurement, cell shunt resistance measurement by the shadowing technique, steady-state illumination test station for module performance illumination, laser scanning techniques, and the SEM.

Shumka, A.↗

Optical techniques for shock visualization and detection

While the classical methods of shadowgraph and schlieren do yield a shadow in the neighborhood of a shock, they often suffer from low power densities and the need for relatively long distances. Scanning methods may help in solving these problems. The paper describes various scanning techniques, presents experimental data obtained by mechanical scanning, and identifies conditions at which the data were taken.

Adamovsky, G.↗

Emittance Measurements at FAST Facility

The FAST facility at Fermilab recently been commissioned has demonstrated the generation of electron beam within a wide range of parameter (energy, charge) suitable for accelerator-science and beam-physics experiments. This accelerator consists of a photo-electron gun, injector, ILC-type cryomodules, and multiple downstream beam-lines. It will mainly serve as injector for the upcoming Integrable Optical Test Accelerator (IOTA). At the same time we will also carry out a LINAC based intense gamma ray experiment based on the Inverse Compton scattering. It is essential to understand the beam emittance for both experiments. A number of techniques are used to characaterizing the beam emittance including slit based method and quad scan method. An on-line emittance measurement based on multi-slit method is developed so the emittance measured will be immediately available to support further beam optimization. In this report we will present the results from the emittance studies using this tool. We will also present the emittance measurement based on quads scan technique for the high energy beam line.

43 PARTICLE ACCELERATORS↗

Bimodal Visualization of Industrial X-Ray and Neutron Computed Tomography Data

Advanced manufacturing creates increasingly complex objects with material compositions that are often difficult to characterize by a single modality. Our collaborating domain scientists are going beyond traditional methods by employing both X-ray and neutron computed tomography to obtain complementary representations expected to better resolve material boundaries. However, the use of two modalities creates its own challenges for visualization, requiring either complex adjustments of bimodal transfer functions or the need for multiple views. Together with experts in nondestructive evaluation, we designed a novel interactive bimodal visualization approach to create a combined view of the co-registered X-ray and neutron acquisitions of industrial objects. Using an automatic topological segmentation of the bivariate histogram of X-ray and neutron values as a starting point, the system provides a simple yet effective interface to easily create, explore, and adjust a bimodal visualization. Here, we propose a widget with simple brushing interactions that enables the user to quickly correct the segmented histogram results. Our semiautomated system enables domain experts to intuitively explore large bimodal datasets without the need for either advanced segmentation algorithms or knowledge of visualization techniques. We demonstrate our approach using synthetic examples, industrial phantom objects created to stress bimodal scanning techniques, and real-world objects, and we discuss expert feedback.

image segmentation↗

Preliminary report on airline pilot scan patterns during simulated ILS approach

A series of ILS approaches using seven airline-rated Boeing 737 pilots in an FAA qualified simulator have been conducted. The test matrix included both manual and coupled approaches with and without atmospheric turbulence in Category II weather. A nonintrusive oculometer system was used to track the pilot's eye-point-of-regard throughout the approach. The results indicate that, in general, the pilots use a different scan technique for the manual and coupled conditions; however, the introduction of atmospheric turbulence does not greatly affect the scan behavior in either case. A comparison is made between the objective measures of the instrument scan (oculometer data) and the pilots' opinions of their instrument use. The data show a high degree of consistency among pilots for both the quantitative data and the qualitative data (pilots' opinions). However, there is a slightly lower agreement between the quantitative and qualitative measures.

Spady, A. A., Jr.↗

A magnetic field measurement technique using a miniature transducer

The development, fabrication, and application of a magnetometer are described. The magnetometer has a miniature transducer and is capable of automatic scanning. The magnetometer described here is capable of detecting static magnetic fields as low as 1.6 A/m and its transducer has an active area 0.64 mm by 0.76 mm. Thin and rugged, the transducer uses wire, 0.05 mm in diameter, which is plated with a magnetic film, enabling measurement of transverse magnetic fields as close as 0.08 mm from a surface. The magnetometer, which is simple to operate and has a fast response, uses an inexpensive clip-on milliammeter (commonly found in most laboratories) for driving and processing the electrical signals and readout. A specially designed transducer holding mechanism replaces the XY recorder ink pen; this mechanism provides the basis for an automatic scanning technique. The instrument has been applied to the measurements of magnetic fields arising from remanent magnetization in experimental plated-wire memory planes and regions of magnetic activity in geological rock specimens.

Fales, C. L., Jr.↗